AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR

Similar documents
AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR

AD SP. Air Dryer User Manual. Innovation with Integrity. Version 001 NMR

LN2 Safety Refill Controller LN2 SRC V User Manual

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Replacing a Gun Thermostat

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Temperature Control Unit

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

INSTRUCTION MANUAL MODEL: 690E

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation and Operation Manual

Intelligent cascading kit

POLYMIX PX-IG 2000 Operating Instructions

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

UV Lamp and Quartz Sleeve Replacement/Maintenance

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

COOPER POWER SERIES. Reclosers MN280015EN

Installation & Operating Guide

Platen Heater Pad Replacement

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

CEILING SPEAKER SYSTEM

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

Owner's Manual TABLE OF CONTENTS

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Installation & Operating Guide

Owner's Manual TABLE OF CONTENTS

CONTENT. 11.Specification

Certified to CSA STD. C22.2 No.117

CEILING SPEAKER SYSTEM

SmartCooler BCU II. User Manual. Innovation with Integrity. Version 002 NMR

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

PRE INSTALLATION PROCEDURES

CEILING SPEAKER SYSTEMS F-2352CU2

MODEL T25225 ELECTRIC MEAT GRINDER INSTRUCTION MANUAL (For models manufactured since 11/12)

Operator's Manual. PCP October 2017

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Heater with Air Conditioning. E-Series Ford Aeromaster

VISUAL DISPLAY DISPENSER OWNERS MANUAL

HD Kompakt Service Manual

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Service package PDAD- -SP (en) Assembly instructions d [ ]

WSK300 Multifunction Wall Control

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

Refrigerant Recovery Machine. Model No Operating Manual

AC-12200E Portable Air Conditioner

STEAMPRO. Steam Generator Troubleshooting and Service Guide

MEG51. 5-in-1 Grinder And Strainer Assembly & Operating Instructions

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Audi-Larm Audible Alarm

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Installation Instructions

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

TECHNICAL INSTRUCTIONS

Four Post Boot & Glove Dryer

Mini-Rooter Operating Instructions

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

Installation & Operating Instructions

Instruction Sheet DANGER

CEILING SPEAKER SYSTEMS F-2352C

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

20 High velocity Air

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

Fig. 1 - Unit PHD4 and WPH4

Instruction Sheet DANGER

Instant Hot Water Dispenser Owner s Manual

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

Read All Instructions Thoroughly Before Installing or Using the Disposer.

Installation Manual. Breeder Control Installation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending

Installation Instruction Manual ILS-S

PAP Disinfecting Device User Guide. For all PAP Devices (Positive Airway Pressure) CPAP, APAP, Bi-PAP

Square D Clipsal Outdoor Light-Level Sensor

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

ZD-985 Desoldering Station

HI COD REACTOR and Test Tube Heater 2008 Series

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

MEGRIND55. Electric Meat Grinder Assembly & Operating Instructions

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

Refresh & Clean Carpet Washer

Portable Air Conditioner

WAILEA OWNER S MANUAL

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

OPERATOR'S MANUAL HD-400

Multi-Mode Electrode pro

Instruction Book for HD Punch Machines

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

Installation Instructions

INSTALLATION INSTRUCTIONS

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

, '0''/).''$ /*'( 1'%* 00) ',))% *)) $ 3:36;$ !"## $%& '()*+,,,( '()*

Installation Instructions

Transcription:

AD XT Air Dryer Service Manual Version 003 Innovation with Integrity NMR

Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means without the prior consent of the publisher. Product names used are trademarks or registered trademarks of their respective holders. This manual was written by Patrick Krencker September 12, 2014 Bruker Corporation P/N: W150933 DWG: WN150011_00 For further technical assistance for this product, please do not hesitate to contact your nearest BRUKER dealer or contact us directly at: Bruker Corporation 34 rue de l Industrie F 67166 Wissembourg Cedex France Phone: + 49 721 5161 0 FAX: + 33 388 736 820 E mail: nmr support@bruker.de Internet: www.bruker.com

Contents Contents 1 About... 5 1.1 This Manual... 5 1.2 Policy Statement... 5 1.3 Symbols and Conventions... 5 2 Introduction... 7 3 Maintenance Kit 12 Months: W117570... 9 3.1 Gas Filters Replacement... 9 4 Inlet Filter Replacement... 11 4.1 Outlet Filter Replacement... 11 4.2 Silencer Filter Replacement... 12 4.3 Reset Service Counter... 12 5 Maintenance Kit 24 Months: W117571... 13 6 Drying Agent Replacement... 15 6.1 Replacement of Valves Diaphragms... 16 W150933_1_003 3

Contents 4 W150933_1_003

About 1 About 1.1 This Manual This manual is intended to be a reference guide for operators and service technicians. It provides detailed information about the user level maintenance and service, as well as overall use of the Bruker device. Before starting any work, personnel must read the manual thoroughly and understand its contents. Compliance with all specified safety and operating instructions, as well as local accident prevention regulations, are vital to ensure safe operation. The figures shown in this manual are designed to be general and informative and may not represent the specific Bruker model, component or software/firmware version you are working with. Options and accessories may or may not be illustrated in each figure. 1.2 Policy Statement It is the policy of Bruker to improve products as new techniques and components become available. Bruker reserves the right to change specifications at any time. Every effort has been made to avoid errors in text and figure presentation in this publication. In order to produce useful and appropriate documentation, we welcome your comments on this publication. Support engineers are advised to regularly check with Bruker for updated information. Bruker is committed to providing customers with inventive, high quality products and services that are environmentally sound. 1.3 Symbols and Conventions Safety instructions in this manual are marked with symbols. The safety instructions are introduced using indicative words which express the extent of the hazard. W150933_1_003 5

About In order to avoid accidents, personal injury or damage to property, always observe safety instructions and proceed with care. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. This is the consequence of not following the warning. 1. This is the safety condition. u This is the safety instruction. WARNING WARNING indicates a hazardous situation, which, if not avoided, could result in death or serious injury. This is the consequence of not following the warning. 1. This is the safety condition. u This is the safety instruction. CAUTION CAUTION indicates a hazardous situation, which, if not avoided, may result in minor or moderate injury. This is the consequence of not following the warning. 1. This is the safety condition. u This is the safety instruction. NOTICE NOTICE indicates a property damage message. This is the consequence of not following the notice. 1. This is a safety condition. u This is a safety instruction. SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS are used for control flow and shutdowns in the event of an error or emergency. This is the consequence of not following the safety instructions. 1. This is a safety condition. u This is a safety instruction. This symbol highlights useful tips and recommendations as well as information designed to ensure efficient and smooth operation. 6 W150933_1_003

Introduction 2 Introduction This document provides information for the maintenance of the air dryer AD XT. It replaces maintenance information given in the previous product manual. ATTENTION: New part numbers for maintenance kits have been defined. The 12 months maintenance kit W117570 replaces previous part number 50467. The 24 months maintenance kit W117571 replaces previous part number 50468. W150933_1_003 7

Introduction 8 W150933_1_003

Maintenance Kit 12 Months: W117570 3 Maintenance Kit 12 Months: W117570 Bruker P/N W117570 is a 12 months maintenance kit for the air dryer AD XT (P/N W1213728 230V/50Hz or W1213729 115V/60 Hz). The kit contains the following items. Dryer gas inlet filter P/N :W1213724 Dryer gas outlet filter P/N :W1213725 Two large o ring seals A silencer filter LS 3 An electronic chip with a connector (called dongle in the document) The service of the dryer is required whenever the text SEr. blinks on the display of the dryer. This message appears after about 8000 hours of operation. After servicing you will have to use the dongle to reset the service counter. 3.1 Gas Filters Replacement Warning Make sure that the pressure is removed at the inlet of the dryer before any maintenance operation. Place the power switch in position 0 = OFF. W150933_1_003 9

Maintenance Kit 12 Months: W117570 10 W150933_1_003

Inlet Filter Replacement 4 Inlet Filter Replacement Figure 4.1: Gas Filter 1. Open the gas inlet filter housing with a tool (water pump pliers, for example) and unscrew the filter housing. 2. Remove the used filter (2) (unscrew the filter) and install the new inlet filter W1213724 with the O ring seal placed on top. 3. Replace the large housing O ring, located in the holder (1) base block, if it is damaged. 4. Reinstall the filter housing. 4.1 Outlet Filter Replacement 1. Open the outlet filter housing with a water pump pliers and unscrew the filter housing. 2. Remove the used filter (unscrew the filter) and install the new filter W1213725 with its O ring seal placed on top. 3. Replace the large holder O ring if it is damaged. 4. Reinstall the filter housing. W150933_1_003 11

Inlet Filter Replacement 4.2 Silencer Filter Replacement The silencer is located at the base of the dryer unit. Figure 4.2: Silencer Filter 1. Remove the transparent plastic cap of the silencer housing, by turning it to unlock the soft plastic clips and pulling it out. 2. Unscrew the filter and remove it. Install the new filter LS3 and reinstall the silencer housing cap. 4.3 Reset Service Counter Danger of injury from electrical shock! DANGER The electric feed cable remains live even then unit is switched Off. u DO NOT touch live parts! Live electric cables can cause electrical shocks and serious injuries. 1. Switch off the power of the dryer unit. Place the power switch in position 0 = OFF. 2. Open the cover of the MULTITRONICS controls box (4 screws to be removed), you will access to the electronic board inside. 3. Plug the dongle into the interface connector (ref: X9 PC on electronic board). 4. Press AND HOLD the reset button (ref: S3 RESET on electronic board) AND switch on the dryer unit (switch in position I = Fix). The display will show the following message briefly 0.SET, then a flashing OFF. This means that service time counter has been cleared. 5. Switch off the unit and unplug the dongle and close the housing cover of the electronics. Note: The dongle can only be used ONCE to reset the service counter. A used dongle will show briefly FAIL when installed. 12 W150933_1_003

Maintenance Kit 24 Months: W117571 5 Maintenance Kit 24 Months: W117571 The kit contains the same components as kit 12 months and a perforated plate, flat gaskets and the drying agent. The maintenance operations are the same as with the 12 months maintenance kit, but the replacement of the drying agent is added. After servicing you will have to use the dongle to reset the service counter. W150933_1_003 13

Maintenance Kit 24 Months: W117571 14 W150933_1_003

Drying Agent Replacement 6 Drying Agent Replacement Figure 6.1: Drying Agent and Filter Plate. WARNING Danger to health due to dust inhalation. During drying agent replacement dust can be produce. u Wear a dust mask and goggles. Instructions: 1. Power off the unit. Unit must not be under pressure. 2. Unscrew the 6 screws on top of unit and remove upper thick plate. 3. Remove gasket and filter plate. 4. Remove pressure springs of both columns 5. Remove the drying agent of both chambers with an industrial vacuum cleaner. 6. Fill both chambers with drying agent. Use a funnel and a rubber hammer (for example) to tap against vessel to compact the drying agent in the chambers. 7. Install plates and springs. 8. Install upper filter and new gasket. W150933_1_003 15

Drying Agent Replacement 9. Install upper plate and screws. Alternatively tighten screws of diagonal opposite corners. Tighten to 25 Nm with a torque wrench. 6.1 Replacement of Valves Diaphragms The replacement kit has the part number: 1801833. It contains a set for 4 valves. It is necessary to replace the valves diaphragms and pistons (items 2, 3, 4) when the valves continuously emit some noise or if the performance of the unit is diminished. Figure 6.2: Valve Diaphragm NOTICE Two types of solenoid valves are on the unit. There are two types of solenoid valves located on the bottom plate of the unit. The valves on the rear side Y1 and Y2 are normally OPEN (the piston DOESN T have a notch, on part 2). The front valves Y3 and Y4 on the front type are normally CLOSED and HAVE a notch, on part 2). Instructions: 1. Power off the unit. 2. Open spring holder 5 and disconnect the solenoid coil 1. Note the position and type of valve (with or without notch on part 2). 3. Open the 4 screws and remove part 3 and the diaphragm 4. 4. Install new diaphragm (please note that the diaphragm has a spur that corresponds to a hole in the base plate), install same type of valve, tighten the 4 screws. 5. Install solenoid coil and lock it with its spring holder. 16 W150933_1_003

W150933_1_003 17

Bruker Corporation info@bruker.com www.bruker.com Order No: W150933