Fiber Optical Multiplexer

Similar documents
RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

T3/E3 Fiber Optic Line Drivers

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

4-Channel Contact Closure Fiber Link Card System

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

ACCURATE ELECTRONICS INC

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

Four channel video link For low cost video transmission

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

4 Channel Contact Closure SFP DIN Fiber Link System

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Product Specification

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Set-Up Procedures. Before You Start

4120 Fire Alarm Network Reference

IR Intelligent Positioning System Installation Manual

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

UNC100 Integra Manual

IR Intelligent Speed Dome Installation Manual

/9308 External Battery Chargers Installation Instructions

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

MT-RJ Optical Fiber System Field Testing

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Greentrol Automation, Inc.

FCD-wire Contents. List of Figures

EOTec 2C32 Installation Guide

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Addressable IDNet Isolator Installation Instructions

TM-76, MD-76 MODEM OPERATING MANUAL. IOA76-1F May 2009 LANEX S.A., 8 Ceramiczna Street, Lublin Service: phone POLAND

Connecting and Routing the Cables

Fiber Optics and Liquid Level Sensors Line Guide

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Analog Room Pressure Monitor RPC Series

DESCRIPTION INSTALLATION

4009 Fiber Optic Link Option Installation Instructions

Intelligent Speed Dome Installation Manual. Version 1.0.0

600 Range Dialer Installation Manual. Version 1.0

RTD TEMPERATURE SENSING SYSTEM

Public Safety DAS Annunciator Panel

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

EXTINGUISHING AGENT RELEASE MODULE

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

IR Intelligent Speed Dome Installation Manual

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Product Specification

Features

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

Rack Mount Series Installation Guide

OPERATION / INSTALLATION

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

OVEN INDUSTRIES, INC.

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

Multi-Graphic MCPB & Series 115B, 2223R, & 2233R

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Praetorian Fibre Optic Sensing

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Network Speed Dome Installation Manual

5000 INSTALLATION GUIDE

Fiber Optic Products Catalog

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FiberSensor Fiber Optic Intrusion Detection System (IDS)

Quick Alert Remote (QA216R)

INSTALLATION INSTRUCTIONS

SC-F3G User Manual 1.0

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Sensor Interface Module Installation/Operation Instructions

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

VPS3 Installation Manual

21-light Remote Annunciator. Owner s Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

LHCb Rich Detectors Control and High Voltage Systems

Fiber Optic Cable Fence Disturbance Sensor

PONA 3000 Series High Power EDFA User s Guide

8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

Sirius Control Box 6130 LRIT

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

TOTAL PERIMETER SOLUTION

Installation Guide for inbiox60 Series Access Control Panel

High Speed Positioning System Installation Manual

P2267 NETWORK INTERFACE

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

Attention Items: I. Brief Introduction

Transcription:

Fiber Optical Multiplexer 8x E1, 1x Fast Ethernet, Hotline, 1x Fiber optic XL-FMUX4E1 User s Manual

Thank you for using XtendLan s products. This manual will show you how to install and use this product. Please read it carefully before installation and operation. You can refer to it if any difficulty on operation. 1 Product Description 1.1 Function Description XtendLan fiber optical multiplexers product family provides ideal solutions for building fiber base E1 or T1 networks. They have a range from 4x E1 up 16x E1. XL-FMUX4E1 can multiplex to 4 E1 signals for transmission over an optical fiber, resulting in reaching a longer distance without a repeaters and superior performance compared to copper media. XL-FMUX4E1 is the 4E1 point-to-point optical transport equipment that uses the FPGA chips and it is easy to upgrade. It is single board structure and the largest transmission capacity is 4E1. The outer design use the standard 19 inches rack, so the volume is little, weight is light and operation is convenient and credit. 4 E1 fiber optical mulitplexer uses the PDH fiber transmission technologies. The 2M (E1) interfaces can connect with the exchanger, light loop device and multi-diplexer directly to form the micro, midi or the special network. Complete alarm function for FMUX4E1, it is stable and easy to maintenance, install and small in size. It has one digital service telephone. 1.2 Features Below lists the features for XL-FMUX4E1: Offer 4x 2Mb/s digital interfaces Up to 4 E1 links on one fiber Management through Console port The supervisory control interface implements centralized monitoring and export the monitor and control information of this port and opposite port. One link to service telephone for duty contract 90-260VAC & -48VDC power options and the positive and negative of DC-48V can be optional because there is the self-test circuit for the polarity inside th1e device

Standard 19 inches rack, little volume, light weight, steady capacity and convenient setup Digital clock recovery circuit and digital smooth DPLL adopted for 2.048Mb/s port LED indicators 1.3 Application XTENDLAN XL-FMUX4E1 can be used a high-speed baseband modem for point to point that connects two DTE over a lease Line. From Router CSU/DSU XL-FMUX4E1 Fiber optical XL-FMUX4E1 CSU/DSU DTE as illustrated in the Following Diagram.

1.4 Specification E1 line Interface Number of E1 4 E1 s Interface Standard ITU-T G.703 Line Rate 2.048Mbps±50ppm E1 Impedance 120 ohm (balanced) Line Code HDB3 HDB3 Connector Type RJ-45 Jitter tolerance Fine than G.742,G.823 Optical Fiber Interface Wavelength 1310nm Connector Type SC Light Source MLM Laser Detector PIN Photodiode System Gain 26 db (Min.) Input Sensitivity -38dBm (Ber<10e-10) Line Code Scrambled NRZ Output power -6dBm Physical/Electrical Dimension Mounting Power Source Power consumption Temperature Range Dimension Height 44 mm / 1.7 in (1U), Width 485 mm /19 In Depth 160 mm / 6.3 in Stand-alone,19 and 9.5 inch rack mount, wall mount also available 100 240 VAC ( 50H/60Hz) or /+ 48 Vdc ( -36 to 72Vdc) < 5 W 0 C - 50 C (32 to 122 F) Timing Timing derived from incoming E1 Diagnostics Test Loop-back testing for 4 x E1 (Local and remote) Loop-back testing for fiber optical (Local and Remote) Indicators Local optical signal indications for all E1s. Remote optical signal receive indication, working and loss. Loop-back indication. Alarm indication, on or off. Power on indication.

Front panel From left to right phone push button, phone line port RJ-11, DIP switch panel, LED indicators. Rear panel From left to right power supply port 230V and DC 48V, fiber optics port SC duplex connector, 4x RJ-45 E1 ports.

2 INSTALLATION 2.1 Site Selection This is a guideline for XL-FMUX4E1 installation. The following list indicates a site selection guideline. User needs to follow this guideline for the select a proper installation site. For the XL-FMUX4E1 unit, the location should be part of the Central Office (CO) equipment layout design. The entrance cable routing should be considered. The installation should provide a proper room for the adequate ventilation and cable routing at site. At least 0.5 m should be reserve at the rear of the unit for the human access, cable, and airflow. The site should provide a stable environment. The Ops Area (Operating Area) should be free from extremes temperature, humidity, shock and vibration. Do not expose the unit under the rain because XL-FMUX4E1 is not a waterproof unit. Relative humidity should stay between 0 and 95%. Survey the site (power supply) before install the unit.

2.2 Mechanical Installation XL-FMUX4E1 is a desktop and rack mount unit, which offers two kinds of power supply AC or DC. 2.2.1 Double-row indicator light Name Color Status Describe 1 LOS1 Red Active E1 port 1 loss 2 LOS2 Red Active E1 port 2 loss 3 LOS3 Red Active E1 port 3 loss 4 LOS4 Red Active E1 port 4 loss 5 OPLOS Red Active Optical signal Lost 6 OPLOF Red Active Optical SYNC loss 7 PWR Green Active Power on 8 E-3 Red Active Optical BER 10-3 Local Remote Remark:Equipment have two rows indicator light indicate local device status indicate remote device status The equipment has perfect alarm and display. The 14 LED at front panel display different alarms, voice alarms is also offered. The alarms are described as following: Power supply indicator (PWR): this light on when power is on. Local terminal alarm indicator (LOCAL): Remote terminal alarm indicator (REMOTE): Not receiving optical signal alarm indicator (OPLOS): this light on when optical detector not detect input optical signal. Sync loss alarm indicator(oplof): this light on when Optical sync loss. 1-4 branch E1 signal loss alarm indicator (LOS1-4): the light on when corresponding E1 signal loss. The light E-3 on when Local terminal optical BER>=10-3

2.2.2 Front panel DIP definition: Bit 1-4 ( RLOOP1-4 ): 1-4 E1 remote loop. RLOOP1-4 as 1 to 4 port s E1 it is to indicate loop back. If the RLOOP1 is ON, this means that at the far end the is doing a E1 loop-back For example: when RLOOP1 is on, E1 port of remote equipment loops. Bit 5: MUTE is for close alarm voice, ON is close. Bit 6: OLOOP is for optical route loop, ON is loop. OLOOP is the fiber optical Loop-back function. To set the loop-back function, push it to ON and it will perform a local loop back on the optical.

All 8 DIP Switch Description: DIP SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Function and implication ON means remote loop Port 1 remote loop control switch OFF means disable remote loop ON means remote loop Port 2 remote loop control switch OFF means disable remote loop ON means remote loop Port 3 remote loop control switch OFF means disable remote loop ON means remote loop Port 4 remote loop control switch OFF means disable remote loop ON alarm voice close Close alarm voice OFF is alarm voice Open ON is optical fiber loop OLOOP (optical loop function) OFF means Disable fiber loop Reserved Reserved 2.2.3 Hotline phone Hot line phone not occupy 2M channel transmission. On the front panel there is a PUSH button, press on the PUSH button on the remote site it will sound. To answer it the remote site just need to press the PUSH button on the remote unit, the alarm will cut off and just plug in the phone both side able to do the communication. Phone does not occupy the 2M circuits!

2.2.4 Power supply XL-FMUX4E1 fiber optical mux support 3 type powers: AC220V, -48V and +24V. If the power of DC-48V is used, the positive and negative terminal can be optional because there is the self-test circuit for the polarity inside the fiber optical mux. 3. Operation 3.1 Equipment installation After unpacking and before installation, make sure checking the following: Make sure the package is well. If the package is damaged, contact service office of XTENDLAN quickly for solution. Check the package according to the product list, if find equipment severe damaged or lack of some components, please contact installation worker or service office of XTENDLAN. Check whether the equipment type is meet with the type you ordered. Check whether the component is integrity. Check the power supply type. 3.1.2 Quick installation Fasten the Equipment in 19 inch. rack with the screws in the equipment package. Use reliable ground connection at GND point of the equipment Use power tab to connect power according to the manual, don t exchang the polarities. Create user equipment connectting wire according to your demand (2M, V.35 and 10 Base-T), then connectted, don t exchange receive and transfer wires. Connect receive and transfer optical with optical receive and transfer port of the equipment. Don t exchange receive and transfer wires, make sure the optical fiber head is clean, insert optical jumper, make sure connection well. (fiber bending radius 50 mm) Use multimeter to test power polarity and voltage, make sure it match with equipment requirement.

After complete installation and make sure it s ok, power on the switch. Check indicator light meet with practice situation (see related part of manual). A clean, steady environment and firm installation should provided for independent or wall hanging equipment. 3.1.3 Cautions about installation Avoid severe libration and mechanical damage during the process of transfer and installation. Arrange fiber appropriately, fiber bending radius 50 mm. Check voltage and polarity meet with back panel, or it will cause permanent damage to the equipment. Fiber connector can t contaminate, wipe optical fiber head slightly using alcohol, or it will affect transmission. If the fiber connector not butt joint well, it may be cause power decline, adjust fiber connector according to practical situation. The installation position should convenience for personal pass and equipment movement. The environment should dry, clean and ventilation well. Essential static-protective is needed during the installation and maintenance, ground the chassis to increase anti-interference capability and prevent lightning strike. Before use the equipment, independence work ground and protect ground should provided, make sure it ground well. 3.2 Power on the equipment Check indicators and alarms according to manual after power on. If both local and remote work well, fiber interface connect ok, the alarm light OPLOS and OPLOF off, POWER indicator light is green. Light LOSX (X=1-4) is red and voice alarm is on because of not connecting E1 signal. After connect E1 signal, light LOSX (X=1-4) will off, voice alarm will off until all light LOSX is off. Branch shield: shield no using branch alarm, no red light is on when all alarm is off. Hot line phone: after fiber optical mux works normally, insert microphone to hot line phone port, press button PHONE to call remote user, then can communication after the remote user press button PHONE and hold up the microphone. Buzzer rings when remote terminal call local terminal, press button PHONE and hold up microphone, then communicate with remote terminal. Back the button PHONE to norm after communication is completed.

Branch loop: when system work normally and no branch alarm happen, loop test is available with SW. put the SW switch to ON in local terminal, can control remote corresponding 2 Mb/s branch to loop, then can test corresponding output signal at local 2 Mb/s output port. Use this function you can realize loop of all the branches, and it s easy for detect. Use bit error instrument to analyzing performance of 2M branch, and record it. Close voice alarm: voice alarm on when following situation happened: A. Optical disconnected cause OPLOS alarm. B. Signal not steady cause OPLOF alarm. C. Some branches not use and not shielded. Push down SW5 at local terminal, can control closing voice alarm. Note: after failure is removed, set the button to norm, validate the alarm function 3.3 Troubleshooting Best status is configured to this equipment before out of factory, all the functional interfaces are at the front and back panel, don t open the chassis yourself. If have failure, you can determine the range of failure using single loop, and contact our corporation. The following table list common failure and alarm, the reason may cause these alarm and solution to this alarm for you to reference. Equipment alarm and corresponding solutions: Alarm Possible reason Solution 1 POWER off not power on Power connect not well, polarity exchanged 2 OPLOS on 3 OPLOF on Not receive optical signal Not receive normal frame signal Optical disconnected; remote having no optical output Receive signal not steady,check fiber line and equipment 4 E1 alarm Not receive 2M signal Check wire; receive and transfer are exchanged 5 Voice alarm Local alarm happened Shield when process failure

NOTE: XL-FMUX4E1 is a sensitive electronic item, please do handle with extra care on delivery, shifting and humidity. Whenever there is a problem regarding the quality issue within the warranty period, XTENDLAN will take the responsibility to repair with free. After the warranty period, we will charge accordingly depending on the fault or damage. Whenever there is a fault, you can contact our technical support after you identify the problem and the alarm.