Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Similar documents
Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Temperature controller type KTR96EX PTB 97 ATEX 1031 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

TYPE APPROVAL CERTIFICATE

IECEx Certificate of Conformity

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Technical Data. Dimensions

Inductive slot sensor

Exp, pressurized systems

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

IECEx Certificate of Conformity

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Manual for QX0201 Push Button

VERSAFLOW VORTEX Supplementary instructions

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Gas cylinder scale Model GCS-1

DICTATOR Hold-Open Systems for Hazardous Areas

Survey of electrical equipment installed in hazardous areas on tankers

Manual Power relay SR853

Annubar Flowmeter Series

Certificate of Compliance

Earth-Rite II PLUS Static Earthing System

Technical Data. Dimensions

Technical Data. Dimensions

Installation Instructions

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Translation of the assembly instructions with operating instructions and technical appendix

Electrical Installations Design, Selection, Erection and Inspection


SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

INSTRUCTION MANUAL (ATEX / IECEx)

IECEx Certificate of Conformity

Installation Instructions

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Easy installation Certified for zones 1 and 21 High IP degree of protection

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

OPTIBAR P 1010/2010 C Supplementary instructions

Operating Manual Distribution box

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Rosemount 4500 Hygienic Pressure Transmitter. Start

136"ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Instruction manual 640 Securiterre

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

IECEx Certificate of Conform ity

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Physikalisch-Technische Bundesanstalt

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Operating Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Integrated Solutions Low Voltage Systems

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Explanations of Applications in Hazardous Areas

Training, Assessment, Consultants for Hazardous & Industrial Areas

Installation Instructions

OilSET-1000 (12 VDC)

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Requirements for Electrical Installations

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Rosemount 752 Fieldbus Remote Indicator

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

OPTIBAR DP 7060 Supplementary Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

PROTECT SRB 200EXi-1A

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

INSTRUCTION MANUAL (ATEX / IECEx)

SITRANS T temperature transmitters A broad product family for every application. sitrans

IECEx Certificate of Conformity

Electrical Safety Requirements

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

4) Intrinsic Safety Certification

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SET-2000 Hi Level/Oil

Supplementary Installation and Operating Instructions. Category II2G

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Tank Gauging System Special Safety Instruction

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Transcription:

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX 3116 March 1999 thuba Ltd. CH-4015 Basle Telefon +41 061 307 80 00 Telefax +41 061 307 80 10 Headoffice@thuba.com www.thuba.com

Manual PTB 98 ATEX 3116 2 Junction boxes and control boxes Type Series THU 93.1 to THU 93.6 and THU 94.1 to THU 94.9 Target group: Experienced electricians as defined by ElexV and trained personnel. Contents: 1. Safety instructions 2. Conformity with standards 3. Technical data 4. Installation 5. Maintenance 1. Safety instructions Type THU 93.1 to 93.6 and THU 94.1 to 94.9 junction boxes and control boxes are not suitable for duty in Zone 0. Never leave this Instruction Manual or other objects in the enclosure while the equipment is in operation. Operate the junction boxes in undamaged and clean condition, only for their intended purpose, and only in conditions which the enclosure material is capable of withstanding. Incorrectly assembled boxes may no longer meet the requirements of protection type IP 54 as defined by EN 60 529: 1991. Do not make any modifications to the junction boxes that are not expressly mentioned in this Instruction Manual. Whenever work is done on the junction boxes, be sure to observe the national safety and accident prevention regulations and the safety instructions given in this Instruction Manual, which are stated in italics (like this paragraph)!

Manual PTB 98 ATEX 3116 3 2. Conformity with standards The explosionproof junction boxes meet the requirements of EN 50 014:1997, EN 50 018:1994, EN 50 019:1994, EN 50 020: 1994, and EN 50 028 1987. They were developed, manufactured and tested in accordance with state-of-the-art engineering practice and EN 29 001. 3. Technical data Type designation 0102 II 2 G Type code Junction boxes and control boxes Typ THU 9... Enclosure size (numbers 1 9) 0 Junction box (only terminals fitted) 1 Control box 3 Empty enclosure with Part Certificate PTB No. Ex-93.C.3103 U 4 Empty enclosure with Part Certificate PTB No. Ex-92.C.3106 U Type series

Manual PTB 98 ATEX 3116 4 Because of the specific differences between junction boxes and control boxes, they will be dealt with separately in the following. 3.1 Technical data of the junction boxes Explosion protection EEx e II T6 and/or EEx e [ia] IIC T6 and/or EEx ia IIC T6 EC Conformity Certificate PTB 98 ATEX 3116 Enclosure material Stainless steel 1.4301 and 1.4435 Rated voltage e.g. max. 750 V (see rating plate) Max. conductor cross-section e.g. 35 mm 2 (see rating plate) Enclosure protection IP 54 Admissible ambient temperature range 20 C to +40 C 3.2 Technical data of the control boxes Explosion protection EEx ed IIC T6 or EEx ed ia/ib IIC T6 or EEx ed [ia/ib] IIC T6 or EEx em IIC T6 or EEx em ia/ib IIC T6 or EEx em [ia/ib] IIC T6 EC Conformity Certificate PTB 98 ATEX 3116 Enclosure material Polyester Rated voltage e.g. max. 750 V (AC or DC) (see rating plate)

Manual PTB 98 ATEX 3116 5 Rated current e.g. max. 63 A (varies depending on the version) Nominal connection conductor cross-section: internal components max. 16 mm² terminal blocks and terminals max. 35 mm² Enclosure protection type IP 54 Admissible ambient temperature range 20 C to +40 C Maximum figures for internal components Rated Rated voltage current Control and selector switches/pushbuttons 690 V 20 A Temperature controller 250 V 16 A Potentiometers, indicator lights 500 V 10 A Switches and motor starters, contactors, flanged receptacles, fuses, measuring instruments, transformers 690 V 63 A 4. Installation For installation/operation, always observe the provisions of ElexV and the Equipment Safety Law, the rules of generally accepted engineering practice (EN 60079-14), and the instructions stated in this Manual. A terminal diagram is provided with each control box. The terminal diagram, which provides information on contact assignments and the pertinent type testing and conformity certificates, should be followed to the letter. The control boxes are equipped for the external connection of certain terminals and additional components such as control and indicating devices, instrumentation, potentiometers, control and selector switches, flanged receptacles, fuse elements, miniature breakers, contactors, motor protection switches,

Manual PTB 98 ATEX 3116 6 transformers and temperature controllers. In the case of junction boxes, observe points 4.1 and 4.2 of this Manual. 4.1 Terminals Taking the respective Data Sheet into account, use only terminals suitable for mounting on top-hat rails, G-profile rails, or PE busbars. Block terminals can also be used on the mounting plate. For circuits in "increased safety" protection, use only terminals with an EC Conformity Certificate issued by a recognized European testing laboratory in accordance with European standards EN 50 014:1997 and EN 50 019:1994. It is also permissible to use suitable terminals with a "B" or later generation Conformity Certificate issued by a recognized European testing laboratory, provided the manufacturer can document its quality assurance measures and provided that compliance with the relevant requirements of European standards EN 50 014:1997 and EN 50 019:1994 has been verified. The terminals for circuits in "increased safety" protection must be installed in such a way that the leakage paths and clearances called for by EN 50 019:1994 Table 1 as a function of the operating voltage are met. The terminals used for the intrinsically safe circuits do not require certification. But the terminals used must be properly marked, e.g. with light-blue paint. The terminals must be arranged in such a way that at least 50 mm clearance exists between the bare connection parts and between blank parts of the connected conductors of the intrinsically safe and non-intrinsically safe circuits. This clearance is achieved with partition plates or by using suitable end clamps for installation. The clearance between the connection parts of the intrinsically safe circuits and earthed metallic parts must be at least 3 mm, unless the connection parts are used for earthing. Finally, suitable terminals or partition plates must be used to ensure a clearance of at least 6 mm between the connection parts of different intrinsically safe circuits. In the case of mixed components (designation EEx e [ia] IIC T6), the terminals for the circuits in "increased safety" protection must be covered with guards of insulating material to prevent accidental contact. Only guards provided for this purpose by the

Manual PTB 98 ATEX 3116 7 terminal manufacturer are admissible. The guard must be provided with a permanent warning notice. These covers and warning notices may be omitted in the case of junction boxes whose rating plates state that the box should never be opened under voltage. The number of terminal positions provided for the earth conductors must at least equal the number of circuits. The maximum admissible cross-section of the individual earthing conductor terminals as a function of the maximum admissible cross-section of the associated phase and neutral conductor terminals must comply with the following table. Maximum admissible cross- Minimum admissible crosssection of the phase and section of the associated neutral conductor terminal earthing conductor terminal S [mm²] Sp [mm²] 16 S 16 to 35 16 over 35 0.5 For neat arrangement of the conductors and secure connection of the conductors to the terminal blocks, observe the table 2. In the case of parallel terminal blocks, clearances at least 1.5 times greater than those listed in table 2 must be maintained. For versions with a mounting plate, where the conductors cannot be brought in under the terminals, clearances at least 2 times greater than those listed in table 2 must be maintained. 4.2 Cable and conductor entries Install cable and conductor entries only in predrilled holes in which blind plugs are inserted. Install the cable and conductor entries in such a way that accidental loosening is prevented and permanent sealing of the entry points is ensured. Intrinsically safe circuits must be brought in and out through separate entries, which should be clearly identified (e.g. with light-blue paint). Only cable and conductor entries of plastic may be used. Wherever cable and conductor entries are not needed, the holes must be closed off with blind plugs. For junction boxes in "increased safety" protection and mixed components, use only cable and conductor entries with an EC Conformity Certificate issued by a recognized European testing

Manual PTB 98 ATEX 3116 8 laboratory in accordance with European standards EN 50 014:1997 and EN 50 019:1994. It is also permissible to use suitable terminals with a "B" or later generation Conformity Certificate issued by a recognized European testing laboratory, provided the manufacturer can document its quality assurance measures and provided that compliance with the relevant requirements of European standards EN 50 014:1997 and EN 50 019:1994 has been verified. 5. Maintenance The provisions of ElexV 9, ElexV 13 and EN 60079-17 pertaining to servicing, maintenance and testing must be complied with. During servicing, it is particularly important to check those components upon which the type of protection depends.

Manual PTB 98 ATEX 3116 9 Junction boxes and control boxes Data Sheet Size Length Width Height Type Nr./ N [mm] [mm] [mm] THU 93.1 1 150 150 80 THU 93.2 2 300 150 80 THU 93.3 3 200 200 80 THU 93.4 4 300 200 80 THU 93.5 5 400 200 120 THU 93.6 6 300 300 120 THU 94.1 7 200 300 155 THU 94.2 8 380 300 155 THU 94.3 9 380 380 210 THU 94.4 10 380 600 210 THU 94.5 11 600 600 210 THU 94.6 12 600 760 210 THU 94.7 13 760 760 300 THU 94.8 14 800 1000 300 THU 94.9 15 300 380 210 Table 1: Sizes Conductor cross section [mm²] Number of single- or multicore conductors brought in; minimum distance of terminal blocks from enclosure wall for 1 conductor 2 conductor 3 or more conductors or 2 side-by-side 1,5 20 mm 20 mm 20 mm 2,5 20 mm 20 mm 20 mm 4 20 mm 20 mm 25 mm 6 20 mm 25 mm 30 mm 10 25 mm 30 mm 40 mm 16 30 mm 40 mm 50 mm 25 40 mm 50 mm 60 mm 35 50 mm 60 mm 75 mm Table 2