Heating and Air-Conditioning Testing II. Climatic Test Bench

Similar documents
Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay

HEATER, AIR CONDITIONING AND VENTILATION

Climate Control System

Refrigerant Mass and Oil Migration During Start-up Transient

Heat pump supplemental heating system for motor vehicles

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

HEATING AND AIR CONDITIONING

HEATER, AIR CONDITIONER AND VENTILATION

1 - High-velocity gas burners

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

Homework Chapter2. Homework Chapter3

STR-600 Impact Dryer

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

R07. Answer any FIVE Questions All Questions carry equal marks *****

Mobile climate solutions

container glass table ware glass decoration speciality glass float glass pattern glass Float- and Display Glass Annealing Lehr

HEATING AND VENTILATION

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

EVANS TEMPCON DASH HEATER A/C All Electric Control Systems

May 26, 2006, /2, Supersedes Technical Bulletin Group 87 number 03-01, dated May 13, 2003 due to updated treatment procedures.

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

TEMPERATURE SHOCK TEST CHAMBERS

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

Liquid Ring Vacuum Pumps, Compressors and Systems

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

SONAPHONE. Performance test of steam traps Supplement to the operating manual

Appendix 13. Categories of Cooling and Heating systems

BC BRONCOS AIR CONDITIONING UNIT

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

Boreas DV DV AB / WB

Mobile climate solutions

COOPERATIVE PATENT CLASSIFICATION

DOCUMENT TABLE OF CONTENTS

CLIMATE EBERSPÄCHER DIESEL HEATERS MOBILE LIVING MADE EASY.

HEATING AND AIR CONDITIONING

HEATING. Additional heating

HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS. Reduce costs for compressed air generation

1998 Expedition/Navigator Workshop Manual

NTC Thermistor Temperature Sensors. Product Information and Application Notes

SCHNEIDER-KESSEL BERLIN

Air Conditioning Systems

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Cooling water/oil heat exchanger with water thermostatic mixer

Heating and Cooling Systems

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Since 1983 Nuova COTERM has developed a wide range of water heaters.

A660 Air Conditioning Laboratory Unit

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Innovative Air Conditioning for Hybrid and Electric Vehicles

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

4-2. Ventilator control. & Rear ventilators (if equipped) & Side ventilators. & Center ventilators

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

Industrial cooling systems LT

WHITE PAPER: Thermal Management Solutions

AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC

Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger


Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

PROCESS AND CLIMATE COOLING

Innovative Components for Additional Heating Systems

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

Environmental Systems

2013 ASHRAE. Standards & Guidelines CD. Contents

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Troubleshooting the Indoor AHU as a Standard Product

Munters DesiCool removes excess heat in server room

State of the Art. Exceptional Reliability

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

Plant growth chambers

V-Line. Nozzle-mix line burner

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Heat pump and energy recovery systems

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heated tools. Semiconductor equipment

IAV Primero. Fault Simulation for Lambda Probes

Heat recovery systems. For hot air and hot water applications.

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger

Heat-Engineering Trainer. (Refrigeration, Air Conditioning, Boiler, Geothermal)

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

DIGI-VAV APPLICATIONS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

1. General Description

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Transcription:

Heating and Air-Conditioning Testing II Climatic Test Bench

Heating and Air-Conditioning Testing II Climatic Test Bench Content IAV's Climatic Test Benches 4 Mobile Coolant Circuit 6 Evaporator Air Treatment System 8 Condenser Chamber 10 Contact Tanja Vogel +49 5371 805-1303 2 3

IAV's Climatic Test Benches The percentage of new vehicles equipped with an air-conditioning system has risen dramatically in recent years. Additional demands, e.g. for fuel-efficient engines and weightoptimized components with unchanged cooling performance, have given rise to a constant growth in development input for air-conditioning systems. In response to this situation, IAV has installed a climatic test bench for developing and designing air-conditioning systems. In addition to designing and determining the performance of individual air-conditioning components, the test bench in particular provides the means for conducting measurements on the: u overall system with OEM lines and components u front-end section with radiator/fan package u heating/air-conditioner u overall vehicle at idle. 4 5

Condenser chamber Collector I Collector II Evaporator air treatment system Expansion valve External vehicle condenser (test component) Internal condenser Internal evaporator External vehicle evaporator (test component) Oil separator Vehicle air-conditioner compressor

Mobile Coolant Circuit Technical Specifications u Features 1 Internal evaporator 12 kw max. 1 Internal condenser 20 kw max. 1 Electrical compressor drive u Control Variables 1 Compressor speed 500 to 9000 rpm 1 Evaporation pressure 2.5 to 5 bar 1 Overheating 0 to 20 K 1 Undercooling 0 to 20 K 1 Hot gas temperature control 60 to 150 C Configuration Capabilities u Connection of vehicle evaporators and/or vehicle condensers u Integration of different air-conditioner compressors Scope of Testing u Performance measurement on vehicle air-conditioner compressors u Torque measurement u Determination of performance characteristic of vehicle air-conditioner compressors u Measurement Variables 1 Torque 1 Coolant mass flow 1 Temperature and pressure recording 1 Throughout the mobile coolant circuit u Power Output for Compressor 1 0 to 30 V; 0 to 10 A Cooling capacity Ps1 Ps2 u Safety Features 1 Low-pressure shut-off < 2 bar 1 High-pressure shut-off > 35 bar 1 Hot gas temperature shut-off > 150 C Speed [rpm] Mobile Coolant Circuit Compressor speed Condensation pressure control Evaporation pressure control Overheating, controllable between Undercooling, controllable between 500 to 9000 rpm 5 to 30 bar 2.5 to 5 bar 0 and 20 K 0 and 20 K Hot gas temperature control 60 to 150 C Capacity of internal evaporator Capacity of internal condenser Torque measurement Mass flow measurement Pressure and temperature measurement 12 kw 20 kw at the drive motor on Coriolis measurement system upstream and down stream of each component in the cooling circuit 6 7

Dehumidifying Cooling Heating Lateral air discharge into shop Steam humidifier Orifice plate flowmeters Air discharge at front; Connection for air conditioner or frame Shop air intake Lateral air discharge into condenser chamber

Evaporator Air Treatment Systems Technical Specifications u Temperature and Humidity 1 Temperature range: -20 to 60 C 1 Rate of change: 1 K/min 1 Relative humidity: 10 to 95 % u Air Flow 1 Air volume flow: 80 to 800 m 3 /h 1 Small-diameter orifice plate flowmeter: 80 to 200 m 3 /h 1 Large-diameter orifice plate flowmeter: 100 to 800 m 3 /h 1 Air discharge cross section 600 x 400 mm 1 Air discharge cross section 150 mm Ø 1 Air volume flow is adjustable by regulating volume flow or differential pressure u Sensors 1 45 thermocouples 1 1 humidity sensor 1 1 differential pressure sensor 1 1 pressure capsule for ambient pressure u Power Supply Unit Output (e.g. for air-conditioning system) 1 0 to 35 V; 0 to 40 A u Other Features 1 Discharge flange into condenser chamber and at side into shop, with connection for insulated hose Configuration Capabilities u Heating/air-conditioning system on a test rack u Evaporator in a test frame u Vehicle or empty body in the condenser chamber or next to evaporator air treatment system u Measurement of two evaporator systems Scope of Testing u Performance measurements at the evaporator coolant and air side u Air-side pressure loss measurements at the evaporator u Absence-of-water measurements at the air-conditioner u Measurements at the expansion valve u Blower characteristic u Control curve u Heating performance Evaporator Air Treatment System Temperature range -20 to +60 C Rate of temperature change 1 K/min Relative air humidity 10 to 95% Air volume flow 80 to 800 m 3 /h Outlet size at front approx. 300 x 400 mm Lateral air outlet 2 x 150 mm Ø 8 9

Volume flow measurement Air recirculation system for chamber temperature control Condenser air outlet

Condenser Chamber Technical Specifications u Air Recirculation System 1 Temperature range: -20-60 C 1 Rate of change: 1 K/min u Condenser Air Duct 1 Air volume flow: 200 to 8000 m 3 /h 1 Discharge outlet size approx. 700 x 900 mm u Compressor Drive 1 Speed: 500 to 9000 rpm u Sensors 1 52 thermocouples 1 5 pressure sensors 1 2 humidity sensors 1 1 pressure pick-up (air side) 1 1 differential-pressure capsule u Power Supply Unit Output (e.g. for Radiator Fan) 1 0 35 V; 0 100 A u Other Features 1 Exhaust gas extraction/fresh-air intake 1 Discharge flange for evaporator air treatment system Configuration Capabilities u Vehicle, front vehicle or front end with air flowing through condenser air duct u Complete vehicle coolant circuit in test rack u Radiator/fan package u Condenser in test frame in the condenser air duct Scope of Testing u Performance measurements on condensers, coolant and air side u Pressure loss measurements on condensers, coolant and air side u Tests on the entire coolant circuit or entire vehicle u Filling quantity optimization u Cooling behavior in passenger compartment Condenser Chamber Temperature range -20 to +60 C Rate of temperature change 1 K/min Air volume flow 200 to 8000 m 3 /h Size of air-circulation duct outlet approx. 700 x 900 mm Speed range of compressor drive motor 500 to 9000 rpm Connection to evaporator air treatment system 150 mm Ø 10 11

IAV GmbH Carnotstrasse 1 10587 BERLIN GERMANY Tel. +49 30 39978-0 Fax +49 30 39978-9790 www.iav.com Excellence in Automotive Research & Development