Detector switch - Dual Tech SCS

Similar documents
Detector switch - Dual Tech

SCS motion sensors Surface/wall mounting - PIR

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Green Switch HD/HC/HS L/N/NT4658N - AM5658. Technical sheets - Automation MY HOME 1. Front view 8

Controller - 4 x 1-10 V outputs - BUS/KNX

Configuration tool with screen

Passive infrared ceiling sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

UP 258E11 OPTISENS OFFICE

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

EWP2WIRELESS MOTION DETECTOR

Installation Guide. Ceiling PIR Detector (311) Features and Connections

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Tebis application software

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

11,1 30. Ordering data

Sensors and Detectors

Tri-level Control Sensor

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Product and Applications Description

PIR Occupancy & Motion Sensor

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

lighting management standalone sensors

, ,

Detailed operating instructions

Data sheet. Function description. Benefits

Product and functional description

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Detailed operating instructions

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Lighting Management Solutions

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

LPC3BSP65 & LPC3BDP65

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

FR-A180 FR-A360. Occupancy detector. Use

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Technical Application Guide

µdim Microwave Sensors User Manual

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

DALI MSensor 02 Multi-sensor for DALI system

Sensors SR Programming manual

DALI MSensor 02 Multi-sensor for DALI system

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

2. Safety. 4. Function

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

LS800S Intruder Alarm System. Engineering Manual

Presence detector Komfort attachment Installation Instructions

EBDSPIR-PRM-LV Product Guide

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

LPCMPIRM65 & LPCMPIRDSI65

Secure WANDERING INSTALLATION AND USAGE GUIDE

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

MWS3 Ceiling Mount Microwave Occupancy Detector

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

HSD-200Z Z-Wave Motion Sensor

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

OPERATING INSTRUCTIONS

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Flash 3 times per 3 seconds: Under voltage indication, please

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Integrated PIR detectors

Installation Instructions

EasyAir office sensor advanced grouping SNS200

Ceiling Microwave presence/absence detector 12-24V AC/DC

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Operating instructions

1126 Series Ceiling Mount PIR Motion Detector

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Original operating instructions Safety switch with guard locking AC901S AC902S

HDCVI PIR Camera User s Manual

MWS3A-PRM Product Guide

Movement-based energy control

CONTENTS. (User s Manual)

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

1125 PIR Motion Detector

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

D-TECT 3 IP. GJD260 IP Motion Detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Transcription:

0 672 26 0 784 86 5 740 48 5 740 98 Page 1. Use...1 2. Technical characteristics....1 3. Dimensions....1 4. Connection...1 5. Installation...2 6. Operation...2 7. Settings...2 8. Configuration....3 9. Performance....4 10. Care...5 11. Standards and approvals...5 12. Troubleshooting...5 1. Use 3. Dimensions This device allows a light source to be controlled automatically through the detection of any presence in the surveillance zone using local controls. Presence sensor with 180 detection angle. Detection type: infrared PIR) and ultrasound US) Assembly type: wall flush mounted 45 45 51 2. Technical features Voltage: 27 V= No-load power consumption: 20 ma Connection between the sensor and controller: BUS/ cable Wiring: 2 x 0.35 mm 2 Flush-mounting box: 40 mm min. Weight: 60 g Impact resistance: IK04 Penetration by solid and liquid matter: IP20 Usage temperature: - 5 C to + 45 C Storage temperature: - 20 C to + 70 C Type of terminals: screw 4. Connection 35 Light level cell PIR Detector / LED detection LEARN button LED BUS/ Pressing the auxiliary control allows the load to be switched on or off manually. If the control is not pressed, the sensor will cut off the load at the end of the time delay or when the light level threshold has been reached. US Detector / US Detector / ON - OFF button 1/5

5. INSTALLATION 5.1 positioning PIR US 5.2 Recommended light exposure 1 m 2.5 m 2.5 m 7. Settings 7.1 Detection parameters parameters Time delay Modes Detection system Alarm Modes: Auto on/auto off Walk-through mode Manual on/auto off Partial on/ Group off Default value 15 mins PIR very high) Active Time delay: Length of time the load is on after detection. : Detection range setting. Modifiable parameters 3, 5, 10, 15, 20 min 30s - 255 h 59 min 59s Low, medium, high, very high Configuration tools 0 882 30 0 882 35 Initial PIR Not modifiable Maintain PIR Not modifiable Restart PIR PIR, Auto on/auto off mode: Comes on automatically: - At the detection of a presence if there is an insufficient natural level of light. Turns off automatically: - If no presence is detected and at the end of the time delay set. - Or if the natural light level is sufficient regulation activated) Another detection causes automatic switch-on if there is insufficient light. 5.3 Positioning * ) 2 * ) Walk-through mode: - If no presence is detected in the 20 seconds following an initial detection, the product will cut off the load after 3 minutes. - If another presence is detected in the 3 minutes following initial detection, the device will cut off the load at the end of the set time delay. * ) Not supplied 6. OPERATION 1 6.1 More than one sensor and more than one load Manual ON/Automatic OFF mode Pressing the auxiliary control allows the load to be switched on or off manually. If the control is not pressed, the sensor will cut off the load at the end of the time delay or when the light level threshold has been reached. Auto ON/OFF mode: The load will be switched on and off automatically. Option: It is possible to control the sensor by infrared remote control using: Cat. Nos. 0 882 00/01/20/31/32/33. Manual on/auto off mode: Comes on via a manual switch, automatic switch off: - Where no presence is detected and at the end of the time delay set. After switch-off, any new detection within a 30 second period triggers an automatic switch-on. The Restart function must be activated. After 30 seconds the device is switched on via a manual switch. Partial on/group off mode: Possibility of controlling one or more lighting points individually. In this mode it is essential for a lighting group to be created: - either by manual teach phase. - or from the advanced configuration tool Cat. No. 882 30 using the function "PnL capteur" PnL sensor). The sensor switches on the loads that are linked to it via the actuator. Where there is no detection and at the end of the time delay it switches off all loads in the group to which it belongs. 2/5

7. Settings continued) 7.1 Detection parameters continued) Detection system: Initial detection: The load is switched on as soon as the first detection occurs if the natural light level is below the light level threshold. Maintain: The load remains active if another presence is detected. Restart: In manual mode. After switch-off, any new detection within a 30 second period triggers an automatic switch-on. After 30 seconds the device must be switched on manually. 7. Settings continued) 7.3 Modifying the parameters using the configuration tools Alarm: an audible signal is emitted before switch-off. 1 minute before, then 30 seconds, then 10 seconds). 7.2 Light parameters parameter Light level threshold Advanced mode Default value 500 lux Modifiable parameters light level threshold: Value at which the load comes on if the natural light level is less than the setting. Caution: The device becomes a motion detector at 1275 lux. Configuration tools 0 882 30 0 882 35 20, 100, 300, 500, 1000 lux 0-1275 lux Calibration 0-99995 lux Regulation Light contribution Auto Auto - 1275 lux Advanced mode: calibration: The surrounding light level measured with a luxmeter must then be transmitted to the sensor see data sheet Cat. No. 0 882 30). regulation: Automatic switch-off of the load 10 minutes after the light level threshold is exceeded with an additional safety threshold to avoid lights switching off at the wrong moment). Light contribution: Quantity of additional lux provided by the load being switched on. When the light contribution parameter is set to "Auto" value 0) on the configuration tool Cat. No. 0 882 30 the sensor automatically calculates the light contribution. 0 882 35: Simplified configuration tool 0 882 30: Advanced configuration tool When the sensor receives an IR command using the configuration tool it emits a beep acknowledging the modification. For more information about setting parameters, refer to the data sheet for the configuration tool Cat. No. 0 882 30. Range: 1 m. - restore to factory settings: 1 st press: Short press on LEARN: the LED flashes slowly. 2 nd press: Press and hold down LEARN for 10 seconds until the LED flashes quickly. 8. Configuration 8.1 Physical configuration BUS sensor Physical Configuration The physical configuration only authorises point-to-point addressing: one single actuator can be controlled via the sensor. A: Area 0 A) PL: Light point 0 F) M: Mode 0 4) S: of the motion detector 0 3) T: Time delay 0 9) D: Light level threshold or daylight set point 0 5) The A and PL configurator: addressing The A and PL configurators provide the address of the actuator to be controlled. NB: - If the product does not have the A and PL configurators positioned then it is not configured. - The configuration A=0 and PL=0 does not exist The M configurator: the modes The M configurator allows the user to choose the product's modes of operation: M configurator Mode No configurator Automatic On/Off mode & without setting range & with presence detection 1 Automatic On/Off mode & light level measure & without presence detection 2 Supervision mode 3 Automatic On/Off mode & setting range & with detection 4 Automatic On/Off mode & setting range & without detection 3/5

8. Configuration continued) 8.1 Physical configuration continued) The S configurator: the sensor's sensitivity The sensor's sensitivity can be adjusted using the S configurator: If the sensor is a Dual-Tech then the sensitivity selected is applied to all technologies. S configurator of the sensor No configurator Low 1 Medium 2 High 3 Very High The T configurator: time delay Time that the load is switched ON: T configurator Time Delay in min) No configurator 15 1 0.5 2 1 3 2 4 5 5 10 6 15 7 20 8 30 9 40 The D configurator: light level threshold The value of the light level threshold in lux or set point) is set via the D configurator: D configurator Lux Surface mounted wall installation: 300 No configurator False ceiling: 500 1 20 2 100 3 300 4 500 5 1000 8.2 Virtual configuration The sensor is programmed via the Virtual configurator software which can be used to modify / programme all of the sensor parameters. 8.3 Lighting Management Configuration - Plug n Go sensor connected to an inlet in a suspended ceiling controller) - Push n Learn 9. Performance Height 1.2 m m: 4 5 6 8 6 m PIR/ US) 3 m PIR/ US) 90 60 30 5 m PIR/US) Ø m) Low 25%) 7 Medium 50%) 8 High 75%) 10 Very high 100%) 12 m Low 25%) 1 Medium 50%) 1 High 75%) 2 Very high 100%) 5 8 m PIR/US) 9.1 PIR detection Walk-through) 9.2 US detection Walk-through) 0 m) 30 m) 60 m) 90 m) Low 25%) Medium 50%) 6 6 6 2 High 75%) 7 7 6 2 Very high 100%) 8 8 7 3 9.3 PIR + US detection Presence) Side test: Diagonal then side output test: 0 m Low 25%) 3 Medium 50%) 4 High 75%) 5 Very high 100%) 6 4/5

10. Care Keep the lens clean. Clean the surface with a cloth. Do not use acetone, tar-removing cleaning agents or trichloroethylene. Resistant to the following products: - Hexane EN 60669-1) - Methylated spirit - Soapy water - Diluted ammonia - Bleach diluted to 10% - Window-cleaning products. Caution: Always test before using other special cleaning products. 11. Standards Directive: CE Installation standards: NFC 15-100 Product standards: IEC 60669-2-1 Environmental standards: - European Directive 2002/96/EC: WEEE Waste Electrical and Electronic Equipment). - European Directive 2002/95/EC: RoHS Restriction of Hazardous Substances). - Decrees and/or regulations: ERP public buildings) ERT workplace buildings) IGH high-rise buildings) 12. Troubleshooting Problem Causes Solutions Lighting stays on when there is no-one present Lighting does not switch off during the day when there is an adequate level of natural light Lighting switches off when there are people present and the natural light level is not adequate darkness) Sources of interference can cause false tripping, such as: air current, vibrations, radiators Regulation function not active Light level threshold set too high Light contribution is too high Time delay too short Detection sensitivity too low Light level threshold too low 1- Reduce the sensitivity level 2- If the interference continues: using the configuration tool, go into the Detection system parameters, select Maintain and then choose PIR and US 3- If the interference still continues, move the sensor away from sources of interference Activate the regulation function Reduce the light level threshold Check that the sensor is positioned correctly in relation to the window Decrease the power of the luminaires Increase the time delay 10 to 1 minutes is recommended for work areas Increase the sensitivity Move the sensor closer to the work area Increase the threshold 5/5