Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Similar documents
Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

360º Surface Mount Ceiling PIR Light Controller

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

60W Multi PIR Bulkhead

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

5W LED Energy Saver PIR Bulkhead

360 Surface Mount Ceiling PIR Light Controller

360 Ceiling PIR Light Controller

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

18W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

"Options" Sensor Module

High Frequency Sensor

Programmable Security Light Switch

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

Emergency Assist Alarm Kit Single Zone

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

Security Light Transmitter

Digital Room Thermostat with Night Set-back

Installation & Operating Instructions

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Cat. No TPT44. Installation & Operating Instructions

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

Compact Movement Activated Sensor Installation Instructions

Electronic Frost Thermostat

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

Electronic Room Thermostat Cat. No. TRT030

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Professional, Rewireable, Linkable LED Lighting

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

Motion Sensor. Specifications

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

Safety! Seasonal INSIDE THIS ISSUE. Small and Powerful LED lighting Energy Saving without compromise.

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

LED Lighting. Solutions

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Heated Display. Instruction manual. Model: CW147 / CW148

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

, ,

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

LED Lighting. Solutions

LPC3BSP65 & LPC3BDP65

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

PMCSF6 OCCUPANCY SENSOR

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

LED Lighting Solutions

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Spiral Dough Mixer. Instruction manual. Model: CP821

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

LPCMPIRM65 & LPCMPIRDSI65

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Integrated PIR detectors

Ceiling PIR HS presence detector. Product Guide. Overview. Features

OWNERS INSTRUCTION MANUAL

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

µdim Microwave Sensors User Manual

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

SHORT WAVE INFRARED PANEL DRYER

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Super. Bright. Lumens! Super. Slim!

1. Basic safety information 3 2. Proper use 3

INSTALLATION & USER INSTRUCTIONS

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Blender. Instruction manual. Model Modèle Modell Modello Modelo Malli: CR836/DR825

USER GUIDE LOGIC HEAT H

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

Safety and Instruction Manual

600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual

LED Sensor Floodlight AZPOSE XL-S

Heat Shade. Instruction manual. Model Modèle Modell Modello Modelo Malli: DR573/DR574/DR575/DR576/DR577/DR578/DR579/ DL492/DL493/GC882/GC883

HW3 Handwash Installation and Operating Instructions

Transcription:

Surface Mount Wall PIR Light Controller Model: PDWM1500 Installation & Operating Instructions

1. Introduction The PDWM1500 utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the attached lighting load will illuminate for a user-determined time period. An integral daylight sensor ensures all day or night-only operation. A 1m B 1 More sensitive Less sensitive 0~5m Presence Primary zone zone 5 ~10m 5~10m Secondary Motion zone zone

C Lux Dusk/Dawn setting Lux Dusk/Dawn Time On setting Time On D 2 E Mains Mains Supply IN Wall box L N L1 Switched Switched Load Load OUT OUT Connect Earth wire to wall to wall box box Earth Earth terminal terminal The Lux and Time controls should be at the bottom when installed.

2. Parts Included PIR Sensor unit. Instruction manual. Please keep safe for future reference. Accessory Pack. Includes 2x screws. 3. Tools & Parts Needed Terminal or Electricians screwdriver. Small philips screwdriver. Wire cutters. Suitable mains interconnect cable. This product is suitable for indoor use only. 3 4. Selecting a Location Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction. Mounting height should be between 1m and 1.8m. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area (extractor fans, tumble dryer exhausts etc.) including opposite any other light sources such as other security lights. Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions. During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will resume normal operation.

5. Installation IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. All fittings should be installed by competent person in accordance with IEE Wiring Regulations (BS7671) Do not attempt to install if you are suffering from nausea or dizzy spells or on medication with similar side effects. If in any doubt, consult a qualified electrician. 4 After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1.5 sq. mm gauge is used. An isolating switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes. This product can be fitted to standard 16mm UK back boxes. Make sure the Lux and Time Controls are at the bottom of the product when installed.

5 6. Connection Switch off the main power supply or wall switch. Connect the mains supply cable Live core (brown) to L and Neutral core (Blue) to N terminal. Connect the lighting cable Neutral core (blue) to the same N terminal and Lighting Live core (brown) to the L1 terminal on the unit (see diagram D):- NEUTRAL (Blue) N LIVE (Brown) L1 Load LIVE (Brown) L Connect the Earth wire (Green/yellow) to the Earth terminal on wall box. When wiring is complete, set the two adjustment controls on the side of the unit (diagram C) to the following positions: TIME Fully anti-clockwise (Test Mode). DUSK Fully clockwise. Fit the sensor unit to wall box and secure it with two fixing screws provided. (Diagram E)

6 7. Setting up Walk Test Procedure TIME Fully anti-clockwise (Test Mode) DUSK Fully clockwise The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 5 seconds each time. This allows testing to be carried out to establish whether the sensor is covering the required area. The lamp will immediately illuminate as the unit goes through its warm-up period. After approximately 1 minute the lamp will extinguish. Try to remain outside the detection area during the warm-up period. Walk around the sensor to establish the detection area. The sensor will detect within an approximately 9 metre diameter circle from the centre of the sensor location with a 3m ceiling. As you cross a detection zone the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5 seconds). Start moving again after 2 seconds. As you cross each zone the lamp will illuminate. Repeat the above, walking at various distances and angles to the unit. This will help you to confirm the detection pattern. Setting Up for Automatic Operation When walk tests are complete, the unit can be adjusted for automatic operation : The TIME setting controls how long the unit remains illuminated following activation & after all motion ceases. The Time control knob at fully anti-clockwise is Test Mode, slightly adjust to above the T is minimum time approx. 1 min, whilst the maximum time (fully clockwise) is approx. 30 minutes. Set the control to the desired setting between these limits.

7 The DUSK control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the DUSK control knob fully anti-clockwise. The unit will now start operating at dusk. If you require the light to activate earlier, wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative, SLOWLY(a small step at a time) rotate the control in a clockwise direction until a point is reached where the lamp illuminates in response to a hand moving below the unit. Leave the control set at this point. At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite bright), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. dusk), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. Once the unit is set up as desired, ease the unit back into position under spring pressure.

8. Troubleshooting Guide Problem Lamp stays ON all the time at night. Solution Cover PIR lens with a thick cloth. If the light turns out, check detection area for heat or refl ective source. If the light stays on, check wiring. See Connection. 8 PIR keeps activating for no reason (at random). PIR sensor will not operate at all. The PIR sensor will not operate at night. Unit activates during the daytime Turn off at the isolation switch. Turn back on again after 30 seconds. Leave for approximately 15 minutes. If light activates, check area for false activation from heat, wind or refl ective source. Check that the power is switched ON at the power supply or isolation switch. Turn OFF the power to the unit and check the wiring connections. Check the lamp. If the lamp has failed, replace. Ensure that the lamp is seated correctly in the lampholder. Please note that the unit will not detect through glass. (e.g. in a glazed porch). The level of ambient light in the area may be too bright to allow operation at the current DUSK setting. During the hours of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates. Refer to previous section for more details. Adjust the DUSK Control setting anti-clockwise to lower the level of ambient light required for activation.

9. Technical Specifications Primary Detection Range: Up to 5 meters forward at mounting height of 1m 9 Secondary Detection Range: Detection Angle: Power Supply: Maximum Switchable Load: Time On Adjustment: Dusk Level Adjustment: Environmental Protection: Up to 10 meters forward at mounting height of 1m 120º 230 V AC ~ 50Hz 1500W Halogen or Fluorescent/low energy lighting. Not suitable for discharge lighting. 250W fan load 1 minute 30 minutes Day & night or night only operation IP55

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free e of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. 10

HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com Designed in the U.K. 67-058-427 (iss 2) Zerofour November 2011