59-64-0 INSTALLATI INSTRUCTIS WIRELESS OUTDOOR DETECTOR FTN-RRHW/FTN-RRIX FTN-RRG/FTN-RRDS FTN-RRHW Honeywell 5800 Series Compatible FTN-RRIX Interlogix 39.5MHz Compatible FEATURES Narrow Angle Detection Detection Range Adjustability (m / 5m) Intelligent AND logic Horizontal Adjustability Tamper Output FTN-RRG FTN-RRDS Product is not produced by, endorsed by, nor is officially associated with Honeywell, Interlogix, GIG or DSC. FCC NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following two conditions: () This device may not cause harmful interference. () This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user s authority to operate this equipment. IC NOTICE This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: () This device may not cause interference, and () This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux cnr d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes: () L appareil ne doit pas produire de brouillage, et () L utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. Honeywell, GIG, Interlogix, DSC are trademarks owned by Honeywell International, Inc, rtek Security & Control LLC, United Technologies Corporation, and Tyco Safety Products Canada LTD, respectively. OPTEX Inc. products will function with one of either Honeywell, GIG, Interlogix, or DSC systems. However, no OPTEX Inc. product is produced by, endorsed by, nor is officially associated with Honeywell, GIG, Interlogix, DSC. OPTEX Inc. recommends verifying proper enrollment and operation, per control panel installation instructions, at installation. CTENTS GIG Compatible DSC 433MHz Compatible INTRODUCTI - BEFORE INSTALLATI... - ZE CFIGURATI... 3-3 PARTS IDENTIFICATI... 3-4 DETECTI AREA... 4 INSTALLATI - WIRING DIAGRAM... 4 - ENROLLING TO PANEL... 5-3 MOUNTING... 9 3 WALK TEST 3- WALK TEST... 4 DIP SWITCH SETTING 4- WALK TEST MODE... 4- BATTERY SAVING TIMER... 3 4-3 ALARM & TROUBLE OUTPUT... 3 4-4 LED... 3 4-5 PIR SENSITIVITY... 3 5 OTHERS 5- LED LIGHT PATTERN... 4 6 BATTERY 6- HOW TO REPLACE BATTERY... 5 6- BATTERY LIFE... 5 7 SPECIFICATIS 7- SPECIFICATIS... 6 7- DIMENSIS... 6 - -
INTRODUCTI - BEFORE INSTALLATI Failure to follow the instructions provided with this indication and improper Warning handling may cause death or serious injury. Caution Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage. The check mark indicates recommendation. The nix sign indicates prohibition. Warning Do not remove the PCB. Caution Do not touch the PCB except for the DIP switch. Mounting height. Keep the detector parallel to the ground. Consider the direction a person is approaching from, as well as the detection area. 0.8. m ('7" 3'") Parallel Tilt Install the detector in a place where it is free from false alarm factors. For example: Direct Sunlight and reflection Heat source Objects moving in the wind - -
- ZE CFIGURATI SUGGESTIS Set up FITLINK according to location as desired. Below are zone configurations for typical location types. Location Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed; Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas Alarm Output Report to CMS Panel Chime Disarm Away Stay Event Alarm Trouble Instant Alarm Entry delay Instant Alarm Entry delay Toggle On or Off On during disarm On during disarm Toggle On or Off -3 PARTS IDENTIFICATI Mounting base Accessories>> Screw cap Bracket Screw kit For wall mounting Screw (3 0 mm) Transmitter compartment Main unit Main unit cover Lens te>> FCC ID FTN-RRHW: U5X-RE0X FTN-RRG: U5X-RE0X FTN-RRIX: U5X-RE0X FTN-RRDS: U5X-RE30 Screw Fixture IC ID FTN-RRHW: 830A-RE0 FTN-RRG: 830A-RE0 FTN-RRIX: 830A-RE0 FTN-RRDS: 830A-RE30 Screw - 3 -
-4 DETECTI AREA Top view 5 4 3 0 3 4 5 Adjustable range: 95 (by 5 pitch) Adjustable range: 95 (by 5 pitch) 0 3 4 5 Side view 5 m detection length 0 0.8.0. 0 3 4 5 m detection length 0 0.8.0. 0 3 4 5 INSTALLATI - WIRING DIAGRAM - Overall wiring diagram Transmitter Bracket Red Black White Yellow Red: Power input (+) Black: Power input (-) White: Alarm Yellow: Alarm Green Blue Green: Tamper Blue: Tamper A GND B Main unit te>> The battery in the transmitter is shared with the detector. Connection for TROUBLE is used when monitoring for Tamper. - 4 -
- ENROLLING TO CTROL PANEL Enrolling to Honeywell LYNX Touch L50/L7000 Series. Place the panel into wireless enrollment mode and then trip the tamper three times.. Set Loop Number to. 3. Set Device type to Other. 4. Set Response Type and Alarm Report according to following table. 5. Set Chime to your preferred type. 6. Set Supervision to Supervised. Location Response Type Alarm Report Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas Silent Burglary Perimeter Entry Exit Silent Burglary Enrolling to Honeywell Residential Vista Panels. While in program mode, press *56 to enter Zone Programming Menu Mode.. Select 0 or to determine if you will confirm the sensor after learning it. 3. Enter the zone number that you wish to program (or 00 to exit zone programming). Press [*] to continue. 4. A summary display appears, press [*] to continue. 5. Enter Zone Type according to table. 6. Enter Partition. 7. Enter Report codes according to table. 8. Enter Input Type to 3 = RF (supervised RF transmitter). 9. Learn or input transmitters serial number. (To learn FITLINK, trip the tamper three times.) 0. Change Loop Number to. Location Zone Type Report Codes Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas Type 4 Silent Burglary Type 03 Perimeter Burglary Type 0 Entry Exit Type 4 Silent Burglary 00 Other than 00 Other than 00 00-5 -
- ENROLLING TO CTROL PANEL Enrolling to GIG GC/GC3. Select RF Sensor # (0 to 48).. Select Sensor Type according the following table. 3. Select Sensor Equipment Code as [0000] Other or [0609] Existing Motion Detector. 4. Select Sensor Other Equip code as [0] (this menu only appears if [0000] Other was selected in the previous menu. 5. At the Sensor Serial Number menu, press shift, then press Learn, and then trip detector tamper switch. 6. Select Equipment Age as New. 7. Select Loop Number as Loop. 8. Select Dialer Delay as Enabled. 9. Edit Voice Descriptor according to location. 0. Select Sensor Reports according to following table.. Select Sensor Supervised to Enabled.. Select the desired chime. Location Sensor Type Sensor Reports Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas (3) Response Type (03) Perimeter (0) Exit/Entry (3) Response Type - 6 -
- ENROLLING TO CTROL PANEL Enrolling to DSC PowerSeries. Put control panel into learn sensor mode.. Push tamper switch to enroll FITLINK. 3. Press [*] key to confirm ID. 4. Enter [zone #]. 5. Enter [zone type] according to the following table. 6. Press the tamper again to Activate the Device for Test. 7. Set Zone Attributes according to following table. Location Zone Types Zone Attributes Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas 4-hour n-alarm Instant Delay 4-Hour n-alarm Set Chime or OFF Keep as defaults Keep as defaults Set Chime or OFF - 7 -
- ENROLLING TO CTROL PANEL Enrolling to Interlogix Simon XTi. Put control panel in learn sensor mode.. Push tamper switch to enroll FITLINK. 3. Enter Sensor Number 4. Select Sensor group according to following table. 5. Change Sensor Name of Item to the correct name from the list. 6. Press save to save the changes. Location Sensor Type Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas 5: Local special chime 3: Instant perimeter 0: Entry/exit delay 5: Local special chime Enrolling to Interlogix Concord 4/Concord Express. Put control panel in learn sensor mode.. Select partition. 3. Enter the sensor group according to following table. 4. Push tamper switch to enroll FITLINK. 5. Exit learn sensor mode Enrolling to Interlogix AdvisorOne. From the Sensors screen, press LEARN RF.. Select the sensor group according to following table. 3. Push tamper switch to enroll FITLINK. 4. Press CLOSE. 5. Press EDIT to edit the options. 6. Select Chime Mode as desired. 7. Press SAVE and CLOSE. Location Sensor Type Front Porch; Backyard Carport; Gate Entrance; Deck Crawl Space; Basement; Storage Shed Garage or Sliding Glass Door; Screened in Porch; Sunroom Driveway; Sidewalk; Public Areas 5: Local special chime 3: Instant perimeter : Supplementary Extended Delay 5: Local special chime - 8 -
-3 MOUNTING Remove the mounting base. Open the knockout. Mounting base Joint screw knockout Joint screw knockout 3 Mount the mounting base on the wall. Screw (3 0 mm) Mounting height: 0.8. m 00 mm Screw (3 0 mm) Use this knockout screw hole to mount the base, when making the wall tamper switch effective. If the main unit is peeled off from a wall, this plastic part will be cracked and remain on a wall, activating the tamper switch. te>> Transmitter needs to be enrolled to reciever before installing the detector. 4 Attach the bracket and main section. 5 Open the main unit cover te>> Be sure to set the screw cap after installing the mounting base. - 9 -
6 Determine the horizontal detection angle and attach the fixture. te>> To make adjustments, remove the fixture. tes>> Align the detection area parallel to the wall to reduce interference with the wall. 3 te>> Check that the fixture and bracket engage correctly. When the unit is mounted on the corner to look ahead along the wall, choose the guide-mark located on the opposite side ofthe wall. When the unit is mounted on the wall to look transversely, choose the guide-mark engraved. - 0 -
8 Determine the detection length. ( m or 5 m) If m is required, rotate the lower lens 80 degrees. te>> Do not remove the upper lens. 5 m detection length (Factory default) Side view m detection length Side view 0 0.8.0. 0 3 4 5 0 0.8.0. 0 3 4 5 9 Attach the fixture. 0 Attach the main unit cover. Fixture te>> To prepare for walk test, check that DIPswitch (WALKTEST MODE) is set to (TEST) before attaching main unit cover. Perform walk test. For details, refer to 3-. After walk test is complete, set DIP switch (WALK TEST MODE) from to OFF. te>> The battery life will be shortened unless the DIP switch is set to OFF. - -
3 WALK TEST 3- WALK TEST Set the DIP switch (WALK TEST MODE) to (TEST). Check that LED lights for seconds when the intended object is detected. DIP switch Detected t detected 3 4 5 6 te>> The switch is set to (TEST) by factory default. 3 Set the DIP switch (WALK TEST MODE) to OFF (NORM). DIP switch 3 4 5 6 tes>> The battery life will be shortened unless the DIP switch is set to OFF. To use the LED in normal operating condition, set the DIP switch 4 to. 4 DIP SWITCH SETTING Do not touch the PCB except for the DIP switch. 3 4 5 6 : Factorydefault DIP switch WALK TEST MODE BATTERY SAVING TIMER 3 ALARM & TROUBLE OUTPUT 4 LED 5 PIR SENSITIVITY 6 N/A 4- WALK TEST MODE DIP switch 3 4 5 6 TEST NORM Position TEST (Factory default) Function The LED lights irrespective of the DIP switch 4 (LED) setting. The DIP switch (BATTERY SAVING TIMER) setting is inactive. NORM The LED lights depending on the DIP switch 4 (LED) setting. The DIP switch (BATTERY SAVING TIMER) setting is active. - -
4- BATTERY SAVING TIMER DIP switch 5S Position Function 3 4 5 6 0S te>> The detector will not generate alarms at intervals shorter than the specified time. 5S 0S (Factory default) 5 sec. 0 sec. 4-3 ALARM & TROUBLE OUTPUT DIP switch 3 N.O. Position N.O. N.O. output Function 3 4 5 6 N.C. N.C. (Factory default) N.C. output 4-4 LED DIP switch 4 3 4 5 6 OFF Position OFF (Factory default) LED Function LED OFF te>> If the LED lights, check the DIP switch (WALKTEST MODE) setting. 4-5 PIR SENSITIVITY DIP switch 5 STD Position Function 3 4 5 6 LOW STD (Factory default) rmal sensitivity LOW Low sensitivity - 3 -
5 OTHERS 5- LED LIGHT PATTERN The following explains the LED light pattern. LED Blink Light OFF Detector condition Warm-up te>> The LED blinks even if the DIP switch 4 (LED) is set to OFF. LED indicator Blinks for approx. 0 seconds. Alarm Lights for seconds. - 4 -
6 BATTERY The detector shares the battery with the transmitter. 6- HOW TO REPLACE BATTERY Remove the bracket and main section. Replace the battery. Install a new battery. 3 Attach the bracket and main section. 6- BATTERY LIFE The values indicated are only for reference on each condition. CR3A (3 V, 300 mah) Alarm trigger per day 50 500 Battery Life Approx. 5 years Approx. years - 5 -
7 SPECIFICATIS 7- SPECIFICATIS Model FTN-RRHW FTN-RRIX FTN-RRG FTN-RRDS Detection method Passive infrared PIR coverage 5 m (6'5" 3'3") Detection length limit m, 5 m (6'7", 6'5") Detection width 3'3" wide at 6'5" / 4" wide at 6'7" Detectable speed Sensitivity Power source 0.3.5 m/s (' 4'"/s).0 C (at 0.6 m/s) (3.6 F (at '/s)) CR3A Lithium battery Current draw.μa standby / 3mA max. at 3 V DC Alarm period Warm-up period.0 ±.0 sec. Approx. 0 sec. (LED blinks) Alarm output N.C./N.O. Selectable-Solid State Switch 0 V DC 0.0 A (max.) Trouble output N.C./N.O. Selectable-Solid State Switch 0 V DC 0.0 A (max.) Enable: During DIP switch (WALK TEST MODE) or DIP switch 4 (LED) LED indicator Disable: During normal operation Light/Blink: Warm-up, alarm, masking detection (FTN-RAM-PT only) RF Interference Operation temperature Environment humidity Weatherproof Mounting Mounting height Weight alarm 0 V/m -0 +60 C (-4 +40 F) 95% max. IP55 Wall (Outdoor, Indoor) 0.8. m ('7" 3'") 80 g (6.4 oz.) without wireless transmitter and battery Accessories screw (3 0 mm) *Specifications and design are subject to change without prior notice. 7- DEMENSIS Unit: mm NOTE These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. 76.4 For technical / sales support: 800-966-7839 support@optexamerica.com www.optexamerica.com 5.6 67.5 OPTEX INC. (U.S.) URL: http://www.optexamerica.com OPTEX DO BRASIL LTDA. (Brazil) URL: http://www.optex.net/br/es/sec OPTEX (EUROPE) LTD. / EMEA HQ (U.K.) URL: http://www.optex-europe.com OPTEX TECHNOLOGIES B.V. (The Netherlands) URL: http://www.optex.eu OPTEX SECURITY SAS (France) URL: http://www.optex-security.com OPTEX SECURITY Sp.z o.o. (Poland) URL: http://www.optex.com.pl OPTEX PINNACLE INDIA, PVT., LTD. (India) URL: http://www.optex.net/in/en/sec - 6 - OPTEX KOREA CO.,LTD. (Korea) URL: http://www.optexkorea.com OPTEX (DGGUAN) CO.,LTD. SHANGHAI OFFICE (China) URL: http://www.optexchina.com OPTEX (Thailand) CO., LTD. (Thailand) URL: http://www.optex.net/th/th Copyright (C) 07 OPTEX CO.,LTD.