WIRING DIAGRAM AND INSTRUCTIONS

Similar documents
DOLKPL1KB DOLKPS1KB DOLKSF1KB

DOLKPS1KB Programming & Installation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

AXS Strikemaster Engineering Manual

For more information, please visit or call toll free at

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

HAA2866 HAA2866 ERRATUM

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD AND CARD READER

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

SPLIT-DECODED CONTROLLER

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Secure WANDERING INSTALLATION AND USAGE GUIDE

RFID Card Access Control Unit. Operating Instructions

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

C2 Compact Range Installation & Programming Manual

Operating instructions 2-channel code lock. Item No

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

Touchpad Exit Controller User Guide

Operating Instructions Transponder code lock - Part 2 (split decoder)

NDC-F16. Access Control Panel. Installation Manual

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Installation Guide & User Manual

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Door Release Power Supply

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

AXI LED USER MANUAL (REV. 1.0)

General Purpose IO Technical Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

DIGITAL ALARM UNIT Model ALU-AP

Transponder reader TECHNICAL SHEET (White) (Magnesium)

Touchpad Exit Controller Administration Guide

Installation Instructions

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Independent Zone Control (I.Z.C.)

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Watchguard WGAP864 User Manual

G34 AU1B (External Ultrasonic Sensor) Version 3

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

CORNELL Emergency Response Systems

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

BURGLAR ALARM PANEL BS-468

SOLO Installation manual STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

Installation & User Manual V2.03

Ethernet General Purpose

IDS816 User Manual H Issued January 2009

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Vehicle Security System VSS3 - Vehicle original remote. Setting Guide - English

SPLIT DECODED SECURITY KEYPAD

For silent arm / disarm use BUTTON 2.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Version 1.03 January-2002 USER S MANUAL

Strikemaster ES Engineering Manual

KIT 53. CODEPAD/ALARM USING 68HC705P9

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

EVO192 v3.0 Fire and Burglary What s New

Contents. Glossary

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

3 User s settings. 3.3 Internal clock setting

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Solution 880 Operators Manual. Issue 1.00

QUICK CONSUMER REFERENCE GUIDE

Series. Access Power Controllers. Installation Guide

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Product Manual SZ1145

ZSC100 Gas Detection and Alarm System Controller

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

L900 series USER MANUAL

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

REPEATER FS5200R INSTRUCTION MANUAL

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Premier Hazard STC Instructions

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Ref.1067/032 Ref.1067/042

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

GSM RFID VOICE Alarm System

ELT-KLED EliteSuite LED Keypad Installation Manual

Addendum for STI-6406 with Dual Access Control

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Insight Operating Manual

Auto Dialer. Manual E-921APQ E-921GPQ

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

DYGIZONE GJD910 Lighting Controller & Enunciator

IDM4 CARAVAN ALARM. Operating instructions

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Transcription:

DGPROX PIN Code and/or Badge STAND-ALONE PROXIMITY SYSTEM Wiring diagram PCB front view 8 WIRING DIAGRAM AND INSTRUCTIONS ST2 1 3 1 3 Warning Do not use a switching power supply because of the interference radiation that may disturb the reading of the badges N/C contact RL1 (magnet) N/O contact RL1 (strike) 230V~ Input voltage 12V ~ or = B Request-to-exit PB1 E Alarm Input M Common PB1, E and 4 O Relay 1 contact C Common R Relay 2 N/C contact I1 Anti-tamper switch V1 Varistor ST1 Jumper for reset ST2 Jumper for relay 1 RL1 Door relay RL2 Alarm relay strike V1 This device comes with a varistor. 12 Power supply V Power supply 1 Data 2 Buzzer 3 Green LED 4 Common M 5 Red LED 2 1 E M B 3 5 R C O 12 V For more information, please visit www.devancocanada.com or call toll free at 855-931-3334 ST1 3 2 1 The varistor must be connected on the strike terminal (electromagnet ) operated by the device. If this product operates more than one strikes, each of them should have a varistor. The varistor controls the overload produced by the strike coil back emf. I1 RL2 PB1 ST2 1 3 RL1 Auxiliary reader (terminal connections) 12 V 1 4 5 3 2 See wiring diagram auxiliary reader If you are using a «Shear Lock» electromagnetic lock, it is recommended to use a separate power supply than the one connected to the DGPROX.

Technical features Input voltage 12 VAC/DC Output 1 relay, N/O & N/C contact and 1 relay N/O contact 3A /125V Anti-triggering contact 500 ma 50 V ~ or = Badge entry 500 programmable badges PIN Code 500 programmable codes, 5-digit PIN code Master code 5-digit programmable code Input 1 request-to-exit Keyboard 12-digit keypad with built-in buzzer (audible signal) Distance between the minimum 24 inches (60 cm) second reader and the maximum 45 yards (50 meters) DGPROX unit (cable minimum 7 x 0.6 mm 2 ) Warning: Do not use a switching power supply because of radiation interference, which may disturb the reading of the badges.. Default values Master code: 12345 Door release time : 1 second Key-in keypad: 10 seconds Alarm: Off Audible Signals 1 beep (long) Validation of data in programming mode: master code, proximity badge or time. Or access code validated 2 beeps Accessing the programming mode (short) 4 beeps (short) or exiting from the programming mode incorrect mode, user number and time outputs entered Visual Signals LED color Normal mode Programming mode Green Door relay activated Code/Badge position empty Red Alarm relay activated Code/Badge position busy Orange Programming mode Orange flashing Stand-by Data computing error Request-to-exit The request-to-exit push button PB1 operates relay RL1. The LED turns green when the relay is activated. 9

Setting a New Master Code Enter the master code twice (for the first use, the master code default is 12345). 2 beeps will sound and the orange LED illuminates to confirm that you are in programming mode. Enter *3 then 5-digit for the new master code. The LED goes out for 1 second and an audible beep indicates that the new master code is accepted. Press # to exit from the programming mode. 2 beeps confirm that the reader is in standby mode. 4 beeps indicate a data computing error. Setting the Mode and Time Outputs Enter the master code twice (for the first use, the master code default is 12345). 2 audible beeps, and the orange LED illuminates to confirm entry into programming mode. Operating mode Door relay Alarm Relay Enter 0 then the 2-digit mode number: 00: PIN code and proximity badge, up to 500 users (500 PIN + 500 badges) 01: Proximity badges only up to 500 users. 02: PIN codes or proximity badges, up to 500 users. The LED goes out for 1 second and an audible beep indicates the time has been accepted. Enter 1, then the door release time in seconds: 01 equal 1 second up to 99 for 99 seconds. 00 sets a latched output (toggle on/toggle off) The LED goes out for 1 second and an audible beep indicates the time has been accepted. Enter 2, then the time delay in seconds: 01 equal 10 seconds up to 99 for 990 seconds. 00 for alarm off The LED goes out for 1 second and an audible beep indicates the time delay has been accepted. Press # to exit from the programming mode. 2 beeps confirm that the reader is in standby mode. 4 beeps indicate a data computing error. Setting New PIN Codes and Badges Enter the master code twice (for the first use, the master code default is 12345). 2 audible beeps, and the orange LED illuminates to confirm entry into programming mode. Enter the user number (000 to 499). If the LED is green, the user number is available, therefore present a badge in front of the main reader. Once the audible beep will sound and the green LED will change to orange Press * to validate the badge, without entering a PIN code, and then enter the next user number to program another badge. or To program also a PIN code with the badge, enter a 5-digit code a long beep will sound to confirm that the badge and PIN code have been stored. 10

If the LED is red the user number is unavailable, therefore press the * key twice to cancel the old badge/code. Or enter the next available user number Press # to exit from the programming mode. 2 beeps confirm that you have returned to standby mode. Deleting or Replacing Badges and PIN Codes Enter the master code twice (for the first use the master code default value is 12345). 2 beeps and the orange LED light on to confirm that you have entered into the programming mode. Enter the user number (000 to 499). The LED lights off during 1 second and an audible beep is emitted. The red LED lights on indicating that the user number is unavailable. Press the * key twice (**) to delete the badge and PIN code. The LED lights off during 1second and an audible beep is emitted. The green LED lights on indicating that the PIN code and/or badge have been deleted, the user number (location number) is now empty. Present the new badge in front of the main reader. Press * to validate the badge, without the PIN code, and then enter the next user number to program another badge. or To program also a PIN code with the badge, enter a 5-digit code a long beep will sound to confirm that the badge and PIN code have been stored. To exit from the programming mode at any time press the # key. 2 beeps confirm that you have returned to the standby mode. Reset the Master Code and the PIN codes/badges Put the jumper ST1 to position 2-3. The green LED blinks during 5 seconds. An audible beep confirms that the master code has been reset to the default value 12345. The red LED blinks. Take off the jumper from position 2-3 to go back to a normal mode. OR Keep the jumper on position 2-3 to reset all the proximity badges. The red LED blinks during 5 seconds then stays on during the reset. When the reset is completed the red LED lights off. Take off the jumper from position 2-3 to go back to a normal mode. Operating Instructions Mode 00: Present the badge in front of the DGPROX one audible beep will sound to confirm that the badge is valid, then enter the PIN code. Mode 01: Present the badge in front of the DGPROX reader or of the second reader. Mode 02: Present the badge in front of the DGPROX reader, the second reader or enter the PIN code. After 3 incorrect badge and/or PIN code are entered, the DGPROX reader and the second proximity reader are locked out during 30 seconds and the alarm relay is activated. 2 audible beeps sound when the badge/pin code are not valid. Alarm Function The tamper switch activates the relay of the alarm when the front panel is removed. If the alarm time delay is different to 00, the door monitoring (door ajar or door forced open) is enabled: When the door is opened, without being activated by the request-to-exit button or a badge, the alarm relay is activated after 1 second and the red LED lights on (forced open door). When the badge or the request-to-exit button are used to open a door, if the door stays open, the open contact will trigger the alarm relay according to the door relay output. 11

Momentary output the alarm time delay begins at the end of the door release time. If the door is maintained open after the alarm time delay, the alarm relay is activated and the red LED lights on. Closing back the door will deactivate the alarm relay and the LED lights off. Latched output the alarm time delay begins only when the door stays open after ordering the closing by presenting back the badge or pressing on the request-to-exit button, the alarm relay is activated and the red LED lights on. Closing back the door will deactivate the alarm relay and the LED lights off. 12

User badges list (Make other copies if needed) : User number Name User number Name User Number Name User number Name Time outputs Function n Values Keypad key-in Time * 0 10 = 10 sec, 99 = 99 sec Door release time * 1 01 = 1 sec, 99 = 99 sec «opened door» before * 2 00 = without alarm 01 = 10 sec, 99 = 990 alarm sec Master code * 3 5-digit code Programmed values Supervisor : Building : N : Street : City : Other information : Date : 13

Wiring diagram auxiliary reader DGPROX Reader ST1 3 2 1 I1 RL2 ST2 1 3 RL1 Power 12 supply Power V supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED 2 1 E M B 3 5 R C O 12 V It is recommended to use a separate power supply for the auxiliary reader Distance : minimum 60cm maximum 50 m Auxiliary reader (terminal connections) 12 V 1 4 5 3 2 Input voltage 12V ~ or = 230V~ 14

HOW TO ORDER REPAIR PARTS DEVANCO CANADA 19192 HAY ROAD, UNIT Q SUMMERSTOWN, ON K0C 2E0 TOLL FREE: 855-931-3334 www.devancocanada.com WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: 3 PART NUMBER 3 DESCRIPTION 3 MODEL NUMBER