Owner s Manual. Spa Blower ONGA. Installation & operation instructions

Similar documents
OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

BathPumps. Distributor Catalogue

FLOTEC PRODUCT CATALOGUE, AUSTRALIA PENTAIR FLOW & FILTRATION SOLUTIONS

VADA - Rain2Main Automatic Rainwater Controller

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

HIGH PERFORMANCE POOL & SPA PUMPS

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HIGH PERFORMANCE PUMP

SAFETY AND OPERATING MANUAL

V80-H Multistage Pump Instruction Manual

USER MANUAL ARHS60X ARHS60X-L 600 // SLIDEOUT HOOD

PRO-230 PRO-350 PRO-400 PRO-500 PRO-500DS ECO-PRO

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

ECOFLO V3 POOL & SPA PUMP

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS

SAFETY AND OPERATING MANUAL. All-in-One blower/ vac/mulcher WG502E

Get Cleaning... User Guide Vax Service line AU: NZ: Bagless Cylinder. VPPST1600/ VPPAT1600/ VPP1600P

Owner s Manual. Pool Pump. For the Installation, Operation and Service of

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

OPERATING INSTRUCTIONS

Express Kettle Instruction Booklet

Installation and Operating Instructions

Let s get started VX27. vax.com.au vax.co.nz

Convection Panel Heater

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Cordless 2-in-1 Stick Vacuum Cleaner

Classic Heater Spa Pool Controller

VULCAN HOSPITAL FOOD SERVICE TROLLEY MODEL HFT

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

QUICK GROOM 2 YEAR WARRANTY BHT6450AU USE & CARE MANUAL. To register your product go to remington-products.com.au remington.co.nz

SALT WATER CHLORINE GENERATOR. Model: SMC20TA & SMC30TA SMC INSTRUCTION MANUAL

Installation and Operating Instructions. Models: T4-13DM-SLI-1 T4-14DM-LOW-1 T4-15DM-CUR-1 T4-18GBOX

IMPORTANT SAFETY INFORMATION:

KERATIN & ARGAN OIL NOURISH

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Classic Heater Pool Controller

CLEAN WATER SUBMERSIBLE PUMP

SUBMERSIBLE WATER PUMP

2 IN 1 SUBMERSIBLE PUMP

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final 120v 60Hz. Copyright 2017 Page of 20

DIRTY WATER SUBMERSIBLE PUMP

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Domestic Spa Control Panel

FOOD SLICER. Instruction Booklet ES9600. Please read these instructions carefully and retain for future reference

IMPORTANT SAFETY INFORMATION:

DIRTY WATER SUBMERSIBLE PUMP

User Guide Vax Careline: AU: NZ:

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

VXCB-01 Commercial Advance Backpack. User Guide VXCB-01. vax.com.au/vax.co.nz

DIRTY WATER SUBMERSIBLE PUMP KIT

Platinum Series Electronic Panel Heaters

SPA-QUIP LTD 3 BUTTON ELECTRONIC STANDARD SPA POOL CONTROLLER DEALER STAMP: DATE INSTALLED SERIAL NUMBER SOLD BY INSTALLED BY STARTUP TESTING

Operating Instructions

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Carveasy. Electric Knife. Instruction Booklet

20L Electronic Dehumidifier

Next Generation Corona Discharge Installation & Operation Manual

Inspect bath carefully and report any damage or faults before installation. No claims can be entered in to after installation.

USER MANUAL. Adventure Kings 50L Refrigerator

Polished Dome Kettle. 1.7 litre cordless kettle with water gauge. Instruction Booklet KE7380

Belle-Aqua. 1 litre stainless steel kettle. Instruction Booklet KE7110. Please read these instructions carefully and retain for future reference.

Flomate Mains Boost Pump Installation & Maintenance Instructions

USER MANUAL CANOPY RANGE HOODS - SLIM LINE ACS60AX-L, ACS90AX-L, ACT60AX-L & ACT90AX-L

compact ceramic heater

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

2000W Ceramic Wall Heater with LED Display

1500W CERAMIC HEATER. Instruction Manual

Express Stainless. 1.7 litre cordless kettle in brushed stainless steel. Instruction Booklet KE7305

Owner s Manual. MAX-E-PRO TM Centrifugal Pool Pumps. current protection device must be fitted to

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

SPECIFICATIONS MODEL NO. OZDE1015WA

INSTALLATION MANUAL TBA Evaporative Cooler

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

PZ1, PZ3 & PZ6 Installation Guide

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

DIGIHEAT IN LINE HEATERS

Outdoor Tabletop Heater TTH20 Series

High Pressure Washer 130

Air Purification System. Instruction Book CLI-AP20

8 LITRE URN. Instruction Booklet. Please read these instructions carefully and retain for future reference

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Compact Pressure Washer 100

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

User Guide Vax Careline: AU: NZ:

Instruction Booklet Please read these instructions carefully and retain for future reference

Split Portable Air Conditioner

OPERATING INSTRUCTIONS

instyle collection 2 YEAR WARRANTY D3016AU

Upright Fan Heater Instruction Booklet

ProMaster VSD ECO-SERIES

Convection Panel Heater

General Care and Safety Guide

Ceramic Wall Heater With Remote

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Drying Cabinet With Timer

Transcription:

Owner s Manual ONGA Spa Blower Installation & operation instructions Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of this product.

ONGA These instructions act as a guide only and do not cover every contingency. People not familiar with pool filtration and pumping equipment should seek advice from an authorised Onga stockist. 1. Run 50mm PVC pipe line from the spa pool manifold outlet to spa blower position (maximum operating distance 12 metres), ensuring that the 50mm pipe line has a minimum fall of 1:10 back to the spa, this will allow the pipe line to have minimum water lying in the pipe (refer diagram 1). Diagram 1 SPA BLOWER INSTALLATION AND OPERATION INSTRUCTIONS 2. Run your vertical 50mm pvc pipe a minimum of 600mm above the spa pools maximum water level. Allow 24 hours for glue vapours to dissipate from the pipe work before mounting spa blower onto pipe (failure to do so may cause damage to the spa blower, pipe work and void warranty). Place the blower on the pipe and tighten the stain-less steel mounting screw located on the check-valve (refer diagram 1). DO NOT GLUE THE SPA BLOWER TO THE 50MM PIPE. 3. If the spa blower is to be mounted below water level, extend the air loop 600mm above the maximum water level and return back to the spa blower, drill a bleed hole after loop to remove any condensation (refer diagram 2). DO NOT create a water trap in the blower supply pipe (refer diagram 3), as the water lying in the pipe will create additional back pressure on the spa blower. Mount the spa blower as instructed above (2). Diagram 2 Diagram 3 Page 2

4. If the spa blower is to be used for additional spa jet venturi, connect the supply line into the air supply line of the spa jet using a tee, then follow the instructions of 1 & 2 and refer to (diagram 4) 5. Spa blower MUST be mounted in a vertical position only, with the discharge downwards (refer diagram 1, 2, & 4). 6. If a air switch or three speed option is being fitted a roll of air tube is supplied, enclose the air line in conduit for mechanical protection, place one end of the tube onto the nipple of the air button fitted on the spa pool, place the other end of the air line onto the spa blower, the air nipple is located on the under side of the spa blower. 7. Place the spa blower 10 amp lead into a 240 volt 50Hz designated power point. 8. Minimal Air Hole Specifications 36 x 6 mm Diameter Holes 18 x 8 mm Diameter Holes (refer diagram 5) IMPORTANT INSTALLER PLEASE NOTE The diameter and quantity of air holes listed above are based on a spa pool air manifold maximum water submergence depth of: (1) 600mm (seat/recliner manifold) (2) 800mm (footwell manifold) If the spa depth/manifold dimensions vary from above please contact the Pentair Water office in your state for advice and verification, failure to comply may damage the equipment and void the product warranty. OPERATION OF YOUR SPA BLOWER 1. Switch power on, your spa blower will start. (a) If your spa blower has been plugged into another controller it may not start until the air button or some other form of switching has been pressed. (Check with your installer). (b) Air Switch Blower Operation Simply press the air button located on the spa and your spa blower will start on high speed, press your button again and this will turn the spa blower off. WARNING This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. No part of this appliance is to be located above the spa pool and must be inaccessible to a person in the spa pool. All parts must be fixed so they cannot fall into the spa pool. The appliance should be supplied through a residual current device (RCD) having a rated current not exceeding 30mA. Children should be supervised to ensure they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Page 3

TROUBLE SHOOTING GUIDE Spa blower will not start. SYMPTOM REMEDY Check power point is switched on and sp a blower is plugged in. Check Fuses. Check that air line is connected from the air button to the spa blower. Check that the air line is not kinked. If kinks are visible, remove them otherwise this will stop the pulse of air that operates the micro switch inside the spa blower. Check micro switch operation. Push air button and a faint click should be heard at the spa blower, if no click is heard check all connections if they are all OK and spa blower still doesn't start, remove spa blower and take it to the nearest Pentair Water service agent. Spa blower is making a grinding noise when operating. Spa blower makes a noise when stopping. Bearings/brushes may need replacing. This is only the check-valve operating correctly. Spa blower operates the overload), n stops (cutting out on thermal Could be caused by blockage or insufficient air holes, check installation of the spa blower pipe work, ensure that it has been installed to the specifications, if incorrect call installer. If all plumbing is correct remove the spa blower and take it to your nearest Pentair Water service agent. Spa Blower 1 Cover 1100508 2 Motor (1200 Watt) 707431 3 EMC Filter 707425 4 Micro Switch N/A 5 Air Switch Holder N/A Air Sensor Assembly (Includes Items 4&5) 302470 6 Motor Housing N/A 7 Checkvalve (40mm-50mm) N/A Motor Housing and Check -Valve Assembly 707435 (Includes Items 6&7) 8 Cowl 707497 Plug & Cord (Air-Switch Model) 707492 Plug & Cord (Non Air-Switch Model) 707494 Page 4

Notes: Page 5

Notes: Page 6

Notes: Page 7

IMPORTANT Please attach your sales invoice/docket here as proof of purchase should warranty service be required. Please do not return Warranty Form to Pentair Australia - please retain for your records. Purchased From... Purchase Date... Serial No... Model No... Head Office Pentair AU/NZ: Australia 1-21 Monash Drive, Dandenong South, Vic 3175 National Customer Service: Phone: 1300 137 344 Fax: 1800 006 688 National Dealer Locator: Phone: 1800 664 266 Ema il: We b: New Zealand au.sales@pentair.com www.pentair.com.au National Customer Service: Phone: 0800 654 112 Fax: 0800 806 642 National Dealer Locator: Phone: 0800 664 269 Ema il: Web: nz.sales@pentair.com www.pentair.co.nz International Australia/New Zealand Phone: +61 3 9709 5800 Fax: +61 3 9709 5888 Information contained here-in remains the property of Pentair Water Pty Ltd. Any reproduction, display, publication, modif ication or distribution is strictly prohibited without the prior written permission of Pentair Water Pty Ltd. Disclaimer: Every endeavour has been made to publish the correct details in this data sheet. No responsibility will be taken for errors, omissions or changes in product specif ications. Pentair Water reserves the right to change specif ications L300220 A0513