SiteSentinel itouch Console

Similar documents
Electronic Fuel Management Systems

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System

TLS-300 UST Monitoring and Leak Detection System

TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation

Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Veeder-Root TLS2 Console Gilbarco EMC2 Console

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement

Model 144H. Product Data Sheet , Rev DB February Content

Fuel Management System Operator s Guide

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

Air & Water Heat Pump R832

Tank Sentinel Operator s Guide

ClampOn DSP Pig Detector

AUTOMATIC TANK GAUGES

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

M1500 SiteSentinel itouch Tank-Gauge Monitoring System Installation Guide. Part Number: M1500, Rev. 5

ClampOn DSP Corrosion- Erosion Monitor

Siemens Building Technologies Landis & Staefa Division. for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Installation Manual INTEGRATED MONITORING SYSTEM.

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Specification for On-Line UPS Battery Monitoring and Data Management System

Advanced FireAlarm Panel 1-4Loop

Section PERIMETER SECURITY SYSTEMS

Model 144H. Product Data Sheet , Rev DB February Content

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Medical Refrigerators

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Omniguard 4: Features

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

EVO 200 EVO 400 EVO 550 EVO 5000

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and

When reliability is vital. Alemite Carbon Shield TM Systems deliver

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Refrigerated Incubator Model and Operating Instructions

PowerRouter application guideline

Trident User s Manual

Process Gas Chromatograph

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Leak Detection & Pipeline Management Solutions

PURPOSE AND SPECIFICATIONS

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks..2 Section Waste Management and Disposal.

LORAIN CSP DC Power System

Intelligent addressable fire alarm control panel

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Dräger Polytron 7000 Fixed gas detector

XSD Dry Cabinet

APPLICATION DATA SHEET

AS950 PORTABLE SAMPLERS

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Patriot Systems Limited

Advanced Test Equipment Rentals ATEC (2832)

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

MICROPOINT to MICROPOINT II UPGRADE

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

YOUR PARTNER IN FIRE & GAS DETECTION

3500/61E & 3500/67E Temperature Monitor

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Fuel Management Systems

Bench Top Cooling Tower H893

Module Features are-configurable, no module jumpers to set

Dräger Polytron 8000 Stationary gas detector (EC)

XSD Dry Cabinet

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Dew point set DS 400

Industrial Grade Gas Detection Detecting The Difference

Terminal Automation Solutions SmartRadar FlexLine Global Experience. Locally Applied.

UNC100 Integra Manual

Frequently asked questions: Intelligent Transmitter Series

LORAIN CIP 4890/48120 DC Power System

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Dual-point heat-tracing control system

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Cardax System Comparison

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Sunrise the beginning of a brand new day

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

SiteSentinel Integra 100 /500 Automatic Tank Gauge System Installation Manual

Terminal Automation Solutions

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Intelligent alarm management

Fuel Management System Setup Guide

AK-CS On Board Guide

STRIKE GUARD DELIVERS:

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Transcription:

SITESENTINEL ITOUCH CONSOLE SiteSentinel itouch Console OPW s SiteSentinel itouch is a multifunction, high-quality tank-monitoring system that provides real-time, accurate inventory information for up to 16 underground storage tanks. The enhanced performance of the SiteSentinel itouch improves data processing, allows for future system expansion and can be customized to meet each user s needs. itouch Console Components family of products Applications Provides real-time, accurate inventory information Displays gross- or net-corrected tank volume, product level, water level, and temperature for individual tanks Available output module provides multi-purpose relays, which can be used for outputs such as on-demand leak detection meets and/or exceeds U.S. Environmental Protection Agency regulatory requirements System Features Compliance meets or exceeds U.S. EPA regulatory requirements, protecting the environment in and around storage tanks. Easy-to-Use The graphic display gives one-touch access to real-time inventory data, delivery status, alarm conditions and leak-detection information. Automated Programmable Automatic Leak Detection (ALD) can be set to perform routine required leak tests. The system can automatically e-mail alarms and events. Connectivity Monitors up to 16 probes or sensors that can be connected in any combination. Reports can be printed on the external printer or from SiteConnect on the PC printer. Graphic touchscreen display uses international user-friendly icons Monitors up to 16 probes and/or sensors that can be connected in any combination Touchscreen provides one-touch access to real-time inventory data, delivery status, alarm conditions and leak detection information SiteConnect software, a Windows - Compatible with SmartTalk software for enhanced business management and compliance reporting Automatic Leak Detection (ALD) can be programmed to perform daily, weekly, monthly and annually required leak tests. Once programmed, the itouch system will automatically look for the appropriate quiet time over the course of the day to conduct a static leak test without operator intervention. System provides over 400 programmable correction factors guaranteeing the most accurate tank chart Listings and Certifications 318

itouch Additional System Features Meets weights and measures standards System Alarms in countries where required. Low-Low Product (shutdown) Supports international time, date and Low Product (reorder) decimal formats High Product (alarm) Software is downloadable (Flash RAM) for easy updates High Water (warning) High-High Water (alarm) System interfaces with most POS Sensor devices, supporting standard industry Leak Detection protocols Reports meet the needs and requirements of System uses international icons to the user. create Inventory, Delivery, System Alarm, and Leak Test reports Provides 3 dedicated RS-232 serial communication ports Reports in Metric or English units of measurement System provides 1 output and 1 input Reports can be printed on the external alarms and line leak detectors printer or from SiteConnect on the PC printer Internal power supply automatically switches between 120- and 240-volt Probes and Sensors power systems All probes and sensors are third party Output module (up to 2 modules max.) adds 4 output relays per module to Environmental Protection Agency control external devices regulatory requirements Density measurement ensures that you Management Reports receive the expected fuel quality with Inventory, Delivery, Alarm and Leak each delivery Reports are available at a touch System can automatically e-mail alarms and events via TCP/IP localized settings (date/time formats Fax-out capability with external modem and Metric/English units) TCP/IP interface allows easy Specifications communications using your local Operating Temperature Range: network 14º F to 122º F (-10º C to 50º C) Increased memory size allows for Printer Operating Temperature Range: future system expansion 32º F to 104º F (0º C to 40º C) Normal Cabinet Dimensions: 9.3" H x 12.3" W x 5.2" D (23.5 cm H x 31.1 cm W x 13.3 cm D) Power Requirements Input Power: 100-250 VAC, 50/60 Hz, 0.5 A Input Contact: 12 VDC, 40 ma max. Output Contact: 30 V-AC/DC, 2A Output Module Contact: 2A @ 120/240 AC, 2A @ 24VDC PC Software: SiteConnect on CD-ROM is included Minimum PC Requirements: Pentium processor, 32 MB RAM, 20 MB available hard disk space, recommended PC screen resolution (800 x 600), Windows 98, Windows NT (version SP4 and above), Windows 2000, Windows XP, Windows Vista Printer: System-powered, graphics 40-column thermal printer includes wallmounted bracket and a 6 ft (1.8 m) cable. Intrinsically Safe Barrier is ATEX approved. SiteConnect Software site from your PC quality of your fuel deliveries (density measurement sensor is required) Refresh feature allows you to stay current with product inventory levels at a glance. Inventory changes in your tanks are dynamically updated. View and print inventory, delivery, alarm, leak test, set-up and system diagnostic reports directly from your PC Address book keeps emergency e-mail and fax numbers organized POS protocols selectable through pull-down menus Available in different languages. Pull-down menu allows you to easily select languages. Provides the ability to manage fuel inventory locally or remotely from Multiple password levels provide security for data access SITESENTINEL ITOUCH CONSOLE 319

T H E R E S T H E O L D WA Y... O R T H E R E S T H E NEW T H E S I T E S E N T I N E L i T O U C H C O N S O L E Leading the way in Automatic Tank Gauging Systems OPW s SiteSentinel itouch is a multi-function, high-quality tank monitoring system that provides real-time, accurate inventory information for up to 16 underground storage tanks. The enhanced performance of the SiteSentinel itouch improves data processing, allows for future system expansion and can be customized to meet each user s needs. Applications Provides real-time, accurate inventory information Displays gross- or net-corrected tank volume, product level, water level, ullage, and temperature for individual tanks Available output module provides multi-purpose relays, which can be used for outputs such as overfill or sensor alarms Third Party Certified automatic or on-demand leak detection meets and/or exceeds U.S. Environmental Protection Agency regulatory requirements family of products C O M P L I A N C E E A S Y- TO-USE AU TO M AT E D C O N N E C T I V I T Y The certified leak detection meets or exceeds U.S. EPA regulatory requirements, protecting the environment in and around storage tanks. The graphic display gives one-touch access to real-time inventory data, delivery status, alarm conditions and leak detection information. Programmable Automatic Leak Detection (ALD) can be set to perform routine required leak tests. The system can automatically fax or e-mail alarms and events. Monitors up to 16 probes or sensors that can be connected in any combination. Reports can be printed on the external printer or from SiteConnect on the PC printer. L E A D I N G T H E W A Y I N T A N K G A U G E I N N O V A T I O N

SiteSentinel itouch Monitor Your Tanks with Just a Touch System Features Graphic touch-screen display uses international user-friendly icons Monitors up to 16 probes and/or sensors that can be connected in any combination Touch-screen provides one-touch access to real-time inventory data, delivery status, alarm conditions, and leak detection information SiteConnect software, a Windows -based configuration utility, makes site configuration easy Compatible with SmartTalk software for enhanced business management and compliance reporting Automatic Leak Detection (ALD) can be programmed to perform daily, weekly, monthly, and annually required leak tests. Once programmed, the itouch system will automatically look for the appropriate quiet time over the course of the day to conduct a static leak test without operator intervention. System provides over 450 programmable correction factors guaranteeing the most accurate tank chart Meets Weights and Measures standards in countries where required. Supports international time, date and decimal formats Software is downloadable (Flash RAM) for easy updates System interfaces with most POS devices, supporting standard industry protocols PV4 POS protocol can be modified to meet the needs and requirements of the user. Provides three dedicated RS-232 serial communication ports System provides one output and one input to connect external devices like overfill alarms and line leak detectors Internal power supply automatically switches between120 and 240-volt power systems Output Module (up to 2 modules max.) adds 4 output relays per module to control external devices Density measurement ensures that you receive the expected fuel quality with each delivery. System can automatically e-mail alarms and events via TCP/IP Fax-out capability with external modem TCP/IP interface allows easy communications using your local network Increased memory size allows for future system expansion System Alarms Low-Low Product (shutdown) Low Product (reorder) High Product (alarm) High-High Product (overfill) High Water (warning) High-High Water (alarm) Sensor Leak Detection External Output Module Relays Leak Test Required Density Out of Range C L I IST ED US Reports System uses international icons to create Inventory, Delivery, System Alarm, and Leak Test reports Reports in Metric or English units of measurement Reports can be printed on the external printer or from SiteConnect on the PC printer Probes and Sensors All probes and sensors are third party certified to meet and/or exceed US Environmental Protection Agency regulatory requirements Specifications Operating Temperature Range: -10º C to 50º C (14º F to 122º F) Printer Operating Temperature Range: 0º C to 40º C (32º F to 104º F) Normal Cabinet Dimensions: 23.5 cm H x 31.1 cm W x 13.3 cm D (9.3" H x 12.3" W x 5.2" D) Power Requirements Input Power: Input Contact: Output Contact: 100-250 VAC, 50/60 Hz, 0.5 A 12VDC, 40 ma max. 30V AC/DC, 2A Output Module Contact: 2A @120/240 AC, 2A@ 24VDC PC Software (SiteConnect on CD-ROM is included) Minimum PC Requirements: Pentium processor, 32 MB RAM, 20 MB available hard disk space, recommended PC screen resolution (800 x 600), Windows 98, Windows NT (version SP4 and above), Windows 2000, Windows XP, Windows Vista Printer: System-powered, graphics 40-column thermal printer includes wall-mounted bracket and a 1.8 m (6 ft) cable Intrinsically Safe Barrier is ATEX approved Management Reports Inventory Delivery, Alarm and Leak Reports are available at a touch Reports can be configured to meet localized settings (Date/Time formats and Metric/English units) SiteConnect Software Easy to set-up and configure your entire site from your PC Configure your system to monitor the quality of your fuel deliveries (density measurement sensor is required) Refresh feature allows you to stay current with product inventory levels at a glance. Inventory changes in your tanks are dynamically updated. View and print inventory, delivery, alarm, leak test, set-up and system diagnostic reports directly from your PC Address book keeps emergency e-mail and fax numbers organized POS protocols selectable through pull down menus Available in different languages. Pull down menu allows you to easily select languages. Provides the ability to manage fuel inventory business locally or remotely from a centralized office Multiple password levels provide security for data access NOTE: All information subject to engineering and/or other changes. All trade names are copyrighted. Patents Pending. 2008 OPW Fuel Management Systems 2008 Delaware Capital Formation, Inc. All Rights Reserved. DOVER and the DOVER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation itouchd 4/08 0M

924B Magnetostrictive Probe Trouble-free accuracy with proven magnetostrictive probe technology. Highly accurate, easy-to-use performance for inventory management and in-tank leak detection. Unlike competitive probes that have to be upgraded to handle different liquids, the 924B Probe comes standard in stainless steel and can be used with most petroleum products. The probe also measures water level, providing information to ensure product quality. family of products System Features Accurate Five-point temperature sensing element provides exact temperature compensation for product volume contraction and expansion, allowing for accurate inventory management and in-tank leak detection. All stainless steel construction Welded construction eliminates potential leak points Level 1 probe - 1 probe for all applications Easy-to-Use Automatically transmits probe profile to SiteSentinel isite on start-up, eliminating programming errors. Installation Adjustable probe head centering disks provide a tight fit inside risers with diameters ranging from 2" (5.1 cm) to 4" (10.2 cm). Easy Installation: Can daisy-chain up to 4 probes on one IS channel (SiteSentinel isite only) which makes installation easier and less time consuming Optional Density Float provides a measure of even the slightest changes in product quality within the specified API density range. Compliance Supports programmable ALD (Automatic Leak Detection) to perform daily, weekly, monthly and annually required leak tests as well as 24-hour continuous monthly leak tests (for SiteSentinel isite only). Listings and Certifications 1180 320

Compliance The system is certified to meet or exceed U.S. Environmental Protection Agency s performance standards for 0.1 gph (0.38 lph) volumetric tank tightness testing and 0.2 gph (0.76 lph) monthly monitoring Supports ALD with SiteSentinel ATG family Magnetostrictive Probe Data Measures product level changes to a resolution of 0.0005" (0.0127 mm) Measures product temperature changes to a resolution of 0.001º F (0.0005º C) Measures water level changes to a resolution of 0.01" (0.254 mm) Linearity over the entire probe length is ± 0.04" (1 mm) Leak Test Performance Third-party certified to meet U.S. EPA leak detection requirements (static) in tanks up to 20,000 gallons (76,000 liters) 0.2 gph (0.76 lph) Static Leak Test: 98.18% Pd, 1.82% Pfa 0.1 gph (0.38 lph) Static Leak Test: 96.5% Pd, 3.5% Pfa 0.2 gph (0.76 lph) Automatic Leak Detection (ALD) 0.1 gph (0.38 lph) Automatic Leak Detection (ALD) Probe Length 30-B053 53" (135 cm) 30-B069 69" (175 cm) 30-B077 77" (196 cm) 30-B089 89" (226 cm) 30-B101 101" (257 cm) 30-B105 105" (267 cm) 30-B113 113" (287 cm) 30-B125 125" (317 cm) 30-B137 137" (350 cm) 30-B149 149" (376 cm) Probe Float Kits 30-1509-02 2" (5.1 cm) Gas/Water Nitrophyl Float Kit 30-1509-01 2" (5.1 cm) Diesel/Water Nitrophyl Float Kit 30-3232 2" (5.1 cm) Density Measurement Kit 30-1508-02 4" (10.2 cm) Gas/Water Nitrophyl Float Kit 30-1508-01 4" (10.2 cm) Diesel/Water Nitrophyl Float Kit Stainless steel floats available upon request Note: No leak testing available with stainless steel floats Probe Specifications Type: Magnetostrictive/float Material: Stainless steel body, aluminum cap Location: Hazardous, Class 1, Division 1, Group D Temperature: 5 RTDs Temperature Range: -40º F to 140º F (-40º C to 60º C) Data Cable: 1,000' (300 m) Belden 88760 500' (150 m) max. Belden 88761 GROUND LEVEL GROUND LEVEL 6 in. (15 cm) minimum 13 in. (33 cm) 20 in. (50 cm) Standard Riser 4 in. (10 cm) inside diameter 6 in. (15 cm) minimum 13 in. (33 cm) 20 in. (50 cm) Standard Riser 4 in. (10 cm) inside diameter MANHOLE HEIGHT TANK DIAMETER PROBE LENGTH TANK DIAMETER PROBE LENGTH TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH * (Top of Tank to Top of Manhole Cover) TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH * (Top of Tank to Top of Manhole Cover) 321

T H E R E S T H E O L D WA Y... O R T H E R E S T H E 9 2 4 B M A G N E T O S T R I C T I V E P R O B E Trouble-free accuracy with proven magnetostrictive probe technology Highly accurate, trouble-free performance for inventory management and in-tank leak detection. Unlike competitive probes that have to be upgraded to handle different liquids, the 924B probe comes standard in stainless steel and can be used with most petroleum products. The probe also measures water level, providing information to ensure product quality. All stainless steel construction Welded construction eliminates potential leak points Level 1 probe - one probe for all applications Easy Installation: Can daisy-chain up to 4 probes on one IS channel (SiteSentinel isite only) which makes installation easier and less time consuming Optional Density Float provides a measure of even the slightest changes in product quality within the specified API density range. family of products A C C U R AT E Five-point temperature sensing element provides exact temperature compensation for product volume contraction and expansion, allowing for accurate inventory management and in-tank leak detection. L E A D I N G E A S Y- TO-USE Automatically transmits probe profile to SiteSentinel isite on start-up, eliminating programming errors. I N S TA L L AT I O N Adjustable probe head centering disks provide a tight fit inside risers with diameters ranging from 2" (5.1 cm) to 4" (10.2 cm). C O M P L I A N C E Supports programmable ALD (Automatic Leak Detection) to perform daily, weekly, monthly, and annually required leak tests as well as Segmented Leak Detection (SLD) for 24-hour continuous monthly leak tests (for SiteSentinel isite only). T H E W A Y I N T A N K G A U G E I N N O V A T I O N

Compliance The system is certified to meet and exceed U.S. Environmental Protection Agency s performance standards for 0.1 gph (0.38 lph) volumetric tank tightness testing and 0.2 gph (0.76 lph) monthly monitoring Supports ALD with SiteSentinel ATG family and supports SLD with SiteSentinel isite Magnetostrictive Probe Data Measures product level changes to a resolution of 0.0005" (0.0127 mm) Measures product temperature changes to a resolution of 0.001º F (0.0005º C) Measures water level changes to a resolution of 0.01" (0.254 mm) Linearity over the entire probe length is ± 0.04" (1 mm) Leak Test Performance 3rd party certified to meet US EPA Leak Detection requirements (Static and SLD) in tanks up to 20,000 gallons (76,000 liters) 0.2 gph (0.76 lph) Static Leak Test: 98.18% Pd, 1.82% Pfa 0.1 gph (0.38 lph) Static Leak Test: 96.5% Pd, 3.5% Pfa 0.2 gph (0.76 lph) Automatic Leak Detection (ALD) 0.1 gph (0.38 lph) Automatic Leak Detection (ALD) 3rd party certified to meet US EPA Leak Detection requirements (SLD) in tanks up to 35,000 gallons (132,475 liters) 0.2 gph (0.76 lph) Continuous Leak Test (SLD), 99.1% Pd, 0.9% Pfa Certified Probe 35,000 Gallon Tank (132,475 liters) Certifications 1180 Probe Specifications Type: Magnetostrictive/Float Material: Stainless Steel Body, Aluminum Cap Location: Hazardous, Class 1, Division 1, Group D Temperature: 5 RTDs Temperature Range: -40º to 140º F (-40º to 60º C) Data Cable: 1000' (300 m) Belden 88760 500' (150 m) max. Belden 88761 Probe Length Part No. Description 30-B053 53" (135 cm) 30-B069 69" (175 cm) 30-B077 77" (196 cm) 30-B089 89" (226 cm) 30-B101 101" (257 cm) 30-B105 105" (267 cm) 30-B113 113" (287 cm) 30-B125 125" (317 cm) 30-B137 137" (350 cm) 30-B149 149" (376 cm) Probe Float Kits Part No. Description 30-1509-02 2" (5.1 cm) Gas/Water Nitrophyl Float Kit 30-1509-01 2" (5.1 cm) Diesel/Water Nitrophyl Float Kit 30-3232 2" (5.1 cm) Density Measurement Kit 30-1508-02 4" (10.2 cm) Gas/Water Nitrophyl Float Kit 30-1508-01 4" (10.2 cm) Diesel/Water Nitrophyl Float Kit 4" Float Kit required for SLD feature Stainless steel floats available upon request Note: No leak testing available with stainless steel floats GROUND LEVEL GROUND LEVEL 6 in. (15 cm) minimum 13 in. (33 cm) 20 in. (50 cm) Standard Riser 4 in. (10 cm) inside diameter 6 in. (15 cm) minimum 13 in. (33 cm) 20 in. (50 cm) Standard Riser 4 in. (10 cm) inside diameter MANHOLE HEIGHT TANK DIAMETER PROBE LENGTH TANK DIAMETER PROBE LENGTH TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH * (Top of Tank to Top of Manhole Cover) TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH * (Top of Tank to Top of Manhole Cover) NOTE: All information subject to engineering and/or other changes. All trade names are copyrighted. Patents Pending. 2008 OPW Fuel Management Systems 2008 Delaware Capital Formation, Inc. All Rights Reserved. DOVER and the DOVER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation 924B Data 6/08-1.5M