HEALTHY CLIMATE PureAir Air Purification System

Similar documents
DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

PureAir Air Purification System PCO-12C/20C

The PureAir system improves air quality throughout your home.

The PureAir system improves air quality throughout your home.

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

healthy comfort Indoor Air Quality Solutions

EAC ELITE ELECTRONIC AIR CLEANER INDOOR AIR QUALITY ENGINEERING DATA FEATURES

healthy comfort Indoor Air Quality Solutions

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

AirPurification System

HEALTHY HOME AIR PURIFICATION SYSTEM

AIR PURIFICATION SYSTEM

IAQ-1 DESCRIPTION QUALITY ASSURANCE GENERAL CONSTRUCTION Cabinet UVGI Device Ultraviolet Lamps Ballasts

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Healthy, clean air for your home

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

RS4 Whole House IAQ System

Home air-improvement options to suit your needs

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Owner s Manual. Airgle Personal Air Purifier ( Model: AG25 )

ELECTRONIC AIR CLEANER SAFETY AND INSTALLATION MANUAL MODEL 5000 TABLE OF CONTENTS

Performance and Reliability. CB*, C* and TA* Models

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

MERIT SERIES Downflow

Owners Manual Model: XXL

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Lennox MERIT SERIES. Innovative Solutions for a Comfortable Home Environment

13 GEP A L P - 1 A

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

RGE 13 A T - 1 A

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

Performance Series Indoor Air Quality Systems for Fan Coil Application

MISCELLANEOUS ENGINEERING DATA EXPANSION VALVE CROSS-REFERENCE DATA PRODUCT SPECIFICATIONS

PM2.5. Summary of MEDAIR 4 Models. Air Treatment Unit Indoor Air Quality solution specialist

Multi-Tech S1000 / S1000-Ultra Air Purifier

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

Perfect Solutions for Cleaner, Fresher Indoor Air

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

14 NANO INDUCT. Product Sheet By Air Oasis. Air Oasis, LLP 3401 Airway Blvd Amarillo Tx 79118

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

INDOOR AIR QUALITY PRODUCTS

Classic i series Intelligent air purifier

High Efficiency Air Cleaners

ELITE SERIES Downflow - High Efficiency Blower Motor

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

Refresh. Whole House Germicidal UV Air Treatment. Treats airborne germs, allergens and mold for a healthier, fresher indoor environment

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

MERIT SERIES Up Flow / Horizontal

ELECTRONIC AIR CLEANERS

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Perfect Air Purifiers

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

Residential Duct Mount Builder s Box Media Air Cleaner

2 shp 13 lc 1 36 t - 1 a

HEPA Air Purifier with Ion Flow Technology

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

HEPASilent Air Purification Systems. Clean air is a human right

PCO/UV N-Duct Model. Owner s Guide

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

PROOF. our story. insert pictures of things or people that tell the story. about your company

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Introducing the most technically advanced indoor air treatment system

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

CBX32MV (HFC-410A) SERIES UNITS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Get all of the Field Controls Reference Guides online at fieldcontrols.com or contact us at or

INDOOR AIR QUALITY PRODUCT LINE CARD 10.18

Installation, Start -Up, and Operating Instructions

Welcome to the IQAir revolution.

Clean Air Solutions. A Complete Family of Indoor Air Quality Products, for the Protection of your Home and your Family.

AO BP2400. Product Sheet By Air Oasis. Air Oasis, LLP 3401 Airway Blvd Amarillo Tx 79118

Air Purity Solutions Whole-Home Air Purifiers

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT

WHYNTER Eco Pure Air Purifier

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

Owner s Manual. Air Cleaner with Photo-Catalytic Oxidation Device & Negative Ionizer Model AC-7013 SUNPENTOWN INTERNATIONAL INC.

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Transcription:

PRO SPECIFICATIONS INDOOR AIR QUALITY HEALTHY CLIMATE PureAir Air Purification System Bulletin No. 210730 June 2018 Supersedes April 2015 MODEL NUMBER IDENTIFICATION PCO 3-14 - 16 Unit Type PCO = Photocatalytic Oxidation System MERV Filter Rating 16 = MERV 16 Generation 3 = 3rd Generation Nominal Airflow Capacity 14 = 1400 cfm 16 = 1600 cfm 20 = 2000 cfm FEATURES CONTENTS Air Resistance... 4 Cabinet Match-Ups - With Furnace / Air Handler.6 Dimensions... 5 Features... 1 Minimum Filter Efficiency... 4 Model Number Identification... 1 Optional Accessories... 4 Specifications... 4 APPROVALS ETL safety listing report 3061144A. Conforms to UL STD 1598. Certified to CSA STD C22.2 no. 250.0. WARRANTY All covered components have a limited warranty for five years in residential applications, one year in nonresidential applications. The UVA Lamp / PureAir Cartridge, and pleated MERV 16 Carbon Clean 16 media filters are routine maintenance items and are not covered under the warranty. Refer to the Limited Warranty certificate included with the unit for additional details. OPERATION Return air first passes through the MERV 16 Carbon Clean 16 media filter. The filter removes more than 95% of the particles and bioaerosols (dander, pollen, bacteria, molds, spores, etc.) as they flow through the. The filtered air then passes through the UVA Lamp / PureAir Cartridge. The UVA lamp activates the catalyst on the cartridge that captures and destroys odors and chemical vapors as they flow through the system. The adsorbed pollutants UV Lamp (accumulated gases, liquids, or solids) on the surface of the catalyst are oxidized to carbon dioxide and water. Rather than just absorbing gaseous pollutants (as in carbon systems), the provides a reduction of absolute toxicity. Contaminants are destroyed rather than transferred. The PureAir Cartridge is self-cleaning with respect to the organic material adsorbed on the catalyst surface. No toxic chemicals are used in the. UV Light

FEATURES E B D C F APPLICATIONS The PureAir Air Purification System combines multiple air purification technologies into a single, stateof-the-art, air purifier. The system s primary function is to improve the indoor air quality by: Filtration - The MERV 16 Carbon Clean 16 media filter captures more than 95% of particles 0.3 microns and larger and more than 90% of particles 0.01 microns and larger. Photocatalytic Oxidation - The UVA lamp activates the photocatalyst on the PureAir Cartridge that captures and destroys odors and chemical vapors as they flow through the. The system reduces the toxicity of the treated air stream. The is a multi-position unit that can be installed in the return air side of all types of HVAC whole-house systems. The unit easily adapts to upflow, downflow or horizontal unit applications. No ozone is produced by the ; in fact, ozone is reduced by the. Only requires annual maintenance. INSTALLATION CONSIDERATIONS The must be installed in the return air duct upstream of the supply air blower. Allow a 30 in. service clearance in front of the access door. The control box, pleated filter and the PureAir UVA Lamp Cartridge must be removable. The should be installed in a horizontal position with the access panel facing to the front or rear. The must be connected to either a 120V or 230V power receptacle. If 230V power supply is used, an optional 230V power cord must be ordered separately. See Optional Accessories table. Unit must be powered continuously (the lamp is always on) for destruction of contaminants adsorbed on the catalyst surface and for extended lamp life. It is recommended that the air handler be set to run continuously, except during periods of high humidity (more than 50%). If used in conjunction with an optional UV germicidal light, the following guidelines must be followed: When a germicidal light is used with the in direct line of sight, maintain a minimum distance of 6 ft. from the. If duct system has a 90 bend or turn in the duct between the and germicidal light, a minimum distance of 3 ft. from the PCO should be maintained. Please refer to the Installation Instructions for additional information. Air Purification System / Page 2

FEATURES B COMPONENTS MERV 16 Carbon Clean 16 Media Air Filter (1) Disposable pleated MERV 16 filter (Minimum Efficiency Reporting Value based on ASHRAE 52.2). MERV (Minimum Efficiency Reporting Value) is a rating by ASHRAE that measures the removal of airborne contaminants. The MERV rating of a filter describes the size of the holes in the filter that allow air to pass through. The higher the MERV rating, the smaller the holes in the filter providing enhanced filtration. The dirtier the filter, the better the filtration, however, the filters need to be replaced annually to prevent excess pressure drop and for maximum efficiency. More frequent filter changes may be required in situations with high dust or dirt loads. Particles and bioaerosols are captured on the filter. Recommended annual replacement. UVA Lamp / PureAir Cartridge UVA Lamp (1) C D 55 watt florescent, low power consumption, UVA output. Recommended annual replacement. Lamp is packaged separately for field installation. Thumbscrews on lampholder allow quick and easy access for servicing. PureAir Cartridge Titanium dioxide coated. Cartridge is packaged separately. Recommended annual replacement. E F Control Box Assembly Contains electrical power receptacle, electronic ballast with internal surge protector for UVA lamp. Control box is hinged to allow easy access to the ballast and UVA Lamp / PureAir Cartridge for servicing. CABINET Pre-painted steel cabinet. Multi-position. -14-16 cabinet is sized for most Lennox air handler applications. -16-16 and -20-16 cabinets are sized for most Lennox gas furnace applications. See dimension drawing. Front panel is removable for service access. Air flow direction may be reversed by rotating the unit top for bottom. View port on front panel for verifying UVA lamp operation. Three-prong, detachable 6-foot power cord for plug-in to 120V electrical connection. Optional power cord for 230V operation is available and must be ordered extra. SAFETY FEATURES Power cord must be completely removed from the front of the unit before the cover can be removed for servicing. MAINTENANCE SUPPLIES - ORDER SEPARATELY Annual Maintenance Kit A maintenance kit is available for the -14-16, -16-16 and -20-16. Each kit consists of: Carbon Clean 16 (MERV 16) Media Air Filter (1) Replacement UVA Lamp (1) Replacement PureAir Cartridge(1) MERV 16 Carbon Clean 16 Media Air Filter Recommended annual replacement of the filter. OPTIONAL ACCESSORIES - ORDER SEPARATELY Power Cord For 230 Volt Operation Six foot power cord with NEMA 620P male plug on one end and IEC 320 receptacle on other end allows 230 volt operation without any additional modifications. Air Purification System / Page 3

SPECIFICATIONS Model No. -14-16 -16-16 -20-16 Nominal airflow capacity - cfm 1400 1600 2000 Pressure drop (new unit) - in. w.g. 0.25 0.31 0.31 Pressure drop (end of recommended life) - in. w.g. 0.42 0.42 0.42 Ethanol destruction rate - mg/min. (single pass rated flow destruction rate @ 500 µg/m 3 ethanol) 2.5 3.0 4.0 Number of lamps 1 1 1 Filter size - H x D x W - in. Nominal 20 x 21 x 5 16 x 26 x 5 20 x 26 x 5 Actual 20 x 20-5/8 x 4-3/8 16-3/8 x 25-1/2 x 4-3/8 20 x 25-1/2 x 4-3/8 Filter life Up to 12 months Up to 12 months Up to 12 months Shipping Weight - lbs. 27 25 27 Electrical Data 120V or 1 230V - 1 phase - 60 hz (less than 1 amp) Power Consumption 120 Volt 58 58 58 MAINTENANCE SUPPLIES - ORDER SEPARATELY Annual Maintenance Kit (includes 1 of each per kit) MERV 16 Carbon Clean 16 Pleated Filter 1 230 Volt 58 58 58 Catalog Number (1-pack) Y6616 Y6612 Y6608 Catalog Number (4-pack) Y6618 Y6614 Y6610 Size - H x D x W - in. 20 x 21 x 5 16 x 26 x 5 20 x 26 x 5 UVA Lamp Number of lamps 1 1 1 PureAir Cartridge Size - H x D x W - in. 1-7/8 x 20 x 1 1-7/8 x 20 x 1 1-7/8 x 20 x 1 MERV 16 Carbon Clean 16 Pleated Filter Catalog Number Y6606 Y6605 Y6604 PureAir Cartridge Catalog Number Y6621 Y6607 Y6607 OPTIONAL ACCESSORIES - ORDER SEPARATELY Power Cord for 230V Operation 91X44 91X44 91X44 1 Optional 230V power cord is required and must be ordered extra. AIR RESISTANCE Air Volume cfm -14-16 in. w.g. -16-16 in. w.g. -20-16 in. w.g. 400 0.05 0.04 0.03 600 0.07 0.07 0.06 800 0.11 0.11 0.08 1000 0.15 0.15 0.11 1200 0.20 0.20 0.15 1400 0.25 0.25 0.18 1600 - - - 0.31 0.22 1800 - - - - - - 0.27 2000 - - - - - - 0.31 MINIMUM FILTER EFFICIENCY MERV Rating E1 (0.3 to 1.0 microns) 1 Filter Efficiency (percentage) E2 (1.0 to 3.0 microns) E3 (3.0 to 10.0 microns) MERV 16 95% 99% 99% 1 Values are based on lab tests conducted with conditions included in ASHRAE Standard 52.2. Air Purification System / Page 4

DIMENSIONS - INCHES (MM) 8-3/4 (222) 11/16 (17) 1-3/4 (33) A B C 1-5/16 (33) 1-3/4 (33) UVA Lamp Sight Glass E D Power Connection INLET AND OUTLET OPENING SAME SIZE 1-5/16 (33) 1 AIR FLOW 1 NOTE - Air flow may be reversed by rotating the unit top for bottom. Model No. A B C D E inches mm inches mm inches mm inches mm inches mm -14-16 23-3/4 603 23 584 20-1/4 514 21-1/8 537 18-1/2 470-16-16 26-1/2 673 25-3/4 654 23 584 17-1/2 445 14-5/8 371-20-16 26-1/2 673 25-3/4 654 23 584 21-1/8 537 18-1/2 470 Air Purification System / Page 5

CABINET MATCH-UPS - WITH FURNACE / AIR HANDLER ALSO SEE ILLUSTRATIONS ON NEXT PAGE FOR ADDITIONAL DETAILS Furnaces Air Purification System / Page 6 Filter Cabinet -14-16-16-16-20-16 Comment A Width Furnace with Side Return Air A Width Furnace with Bottom Return Air 28-1/2 x 3 side seal strip or duct transition needed. B Width Furnace with Side Return Air B Width Furnace with Bottom Return Air C Width Furnace with Side Return Air (up to 4 ton) C Width Furnace with Side Return Air (5 ton) No duct transition required, for high system static application use -20-16. Option 1 - No duct transition required, use Return Air Base (98M58). Option 2 - Overcut top edge of side return opening by 1 in. to make opening 15 in. x 23 in. (H x W). C Width Furnace with Bottom Return Air D Width Furnace with Side Return Air Option 1 - No duct transition required, use Return Air Base (98M59). Option 2 - Overcut top edge of side return opening by 1 in. to make opening 15 in. x 23 in. (H x W). D Width Furnace with Bottom Return Air 26-1/2 x 3 1/2 side seal strip or duct transition needed. Air Handlers -14-16-16-16-20-16 Comment Air Handler (W x D) - 15 x 22 in. CBX25UH(V)-018 Air Handler (W x D) - 18-1/2 x 22 in. CBX25UH(V)-024-030 Air Handler (W x D) - 21-7/8 x 22 in. CBX25UH(V)-036 Air Handler (W x D) - 21-7/8 x 26 in. CBX25UH(V)-042-048-060 Air Handler (W x D) - 16-1/4 x 20-5/8 CBX32M-018/024 Air Handler (W x D) - 21-1/4 x 20-5/8 CBA27UH-018 CBA27UH-024 CBA38MV-018/024 CBX32M-030 Air Handler (W x D) - 21-1/4 x 22-5/8 CBA27UH-030 CBA27UH-036 CBA38MV-030-036 CBX32M-036-042 Air Handler (W x D) - 21-1/4 x 24-5/8 CBA27UH-042 CBA27UH-048 CBA27UH-060 CBA38MV-042-048-060 CBX32M-048-060 Duct transition required. 22 x 2 in. side seal strip or duct transition needed. Duct transition required. 21 x 3 side seal strip or duct transition needed. Hot Water Air Handlers -14-16-16-16-20-16 Comment B Width CBWMV with Side Return Air B Width CBWMV with Bottom Return Air C Width CBWMV with Side Return Air (up to 4 ton) C Width CBWMV with Side Return Air (5 ton) No duct transition required, for high system static application use -20-16. Option 1 - No duct transition required, use Return Air Base (98M58). Option 2 - Overcut top edge of side return opening by 1 in. to make opening 15 in. x 23 in. (H x W). C Width CBWMV with Bottom Return Air

CABINET MATCH-UPS - WITH FURNACE / AIR HANDLER UPFLOW FURNACE/AIR HANDLER (Bottom Return Air) UPFLOW FURNACE (Side Return Air up to 4 ton) SUPPLY FURNACE OR AIR HANDLER RETURN SUPPLY FURNACE RETURN DOWNFLOW FURNACE/AIR HANDLER UPFLOW FURNACE (Option 1 Side Return Air 5 ton) (With Optional RAB Return Air Base) RETURN SUPPLY RETURN FURNACE FURNACE OR AIR HANDLER SUPPLY OPTIONAL RAB RETURN AIR BASE HORIZONTAL FURNACE/AIR HANDLER UPFLOW FURNACE (Option 2 Side Return Air 5 ton) (Modified Return Air Opening) SUPPLY TRANSIITON (Field Furnished) RETURN FURNACE OR AIR HANDLER OVERCUT TOP EDGE BY 1 in. 23 in. 15 in. Air Purification System / Page 7

REVISIONS Sections Cabinet Furnace Match-Ups Description of Change Updated to include latest Air Handler models. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2018 Lennox Industries, Inc.