Engine Order Telegraph System (EOT) A067

Similar documents
operating device LOD , 144x72mm designed for retrofit

sm electrics LIGHT SIGNAL ALARM SYSTEM for ER with high signalling Light Signal Devices LED & triac technology available safety on board

Electronic Emergency Telegraph. TG-1 and TG-1A

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

M2500 Engine Controller Installation Manual

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Technical Manual. Level Alarm Unit CARLA & WIDS

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Technical Data Sheet BNWAS. Bridge Navigational Watch Alarm System. Technical Data Sheet. General Features

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

The SMART Choice of Control & Automation. always on top of the situation

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Engineering Guideline. pac- Carriers Type Universal

Insulation fault evaluator EDS460-DG

Process Alarm Solutions

E-16 Main Engine Remote Control System

Remote alarm indicator and test combination MK2430

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

SUPREMATouch Modular Fire & Gas Detection System

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

TM800. Remote alarm indicator and operator panels

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Fully redundant and customizable alarm, monitoring & Control system

MSM - Expansion modules

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

On the job around the clock 24/7: Fire detection systems

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

designed for rail 5000 Series

M1000 Alarm Annunciator

Touchpoint Pro Flexible Gas Control System

TM LANDING CRAFT, UTILITY (LCU) BASIC CRAFT UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL MAINTENANCE INSTRUCTIONS

WELCOME. The human touch in technology. marine

Multiview Monitor / Controller

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Model 4880 Status Output Display Module Manual

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

IMO GUIDELINES ON THE LAYOUT AND ERGONOMIC DESIGN OF SAFETY CENTRES ON PASSENGER SHIPS. Submitted by the Cruise Lines International Association (CLIA)

TYPE APPROVAL CERTIFICATE

YOUR PARTNER IN FIRE & GAS DETECTION

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Dräger REGARD -1 Control System

Fire control panels FC726 FC726-XA

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

ClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a

Parameterisable compact fault annunciator with permanent display

Technical Manual. Electropneumatic Level Measuring System TYPE TN3801

Imtech Marine Free Technics. Type-approved, user-centered yacht automation

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Multi-Gas-Controller MGC2

For Complete Fire and Gas Solutions

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Danfoss gas detection Controller unit

LifeAlarm Fire Alarm Control Panels

FIRElux Emergency Lighting

TYPE APPROVAL CERTIFICATE

Intelligent Security & Fire Ltd

Design. Innovations in Integrated Control Systems

Panel Mounted Fault Annunciator Series

Intelligent Security & Fire Ltd

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Operating Instructions

ALTOR16BV ALARM PANEL

SHAKING WATER BATHS ENGLISH

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Engine room fire caused by failed fuel pipe

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

The Next Generation Machine Protection System

ME 3011C / Alarm Indication / Quick Reference Guide

NGC-40 Advanced Heat-Tracing Control System

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

System 9000TS Sequence of Events Recorder

Fire control panel for modernization

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

MODEL 9010/9020 LCD CONTROL UNIT

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Danfoss gas detection units

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

SACE PR021/K SIGNALLING UNIT

Dräger REGARD -1 Control System

Part 4 Systems and components Chapter 5 Control and Monitoring Systems

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Product Data Sheet Refrigeration Dryer DFX

Product Data Sheet Adsorption Dryer DPS (A)

A Design Method Based on Inherent Testability of Remote Control and Monitoring System for Marine Main Engine

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

PTE0705 Electric Fence Monitor

Modular Fire Panel 5000 Series Just as flexible as your plans

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Transcription:

intuitive operation reliable and economic mtbus-system easy to install highly integrated and modular structure clear system diagnosis via central LCDisplay various interface technologies to your propulsion RC system serial VDR interface type approved by all major classification societies

typical EOT system composition Wing PS A067.1252-000-0111 Wheelhouse EOT A067.2313-431-0111 Wing SB A067.1222-000-0111 INTERFACE to Propulsion RCS system supply: 24VDC nominal Engine Control Room EOT A067.2130-431-0110 mtbus controller A067.74 INTERFACE to: - Propulsion RCS - ER Call - VDR - Alarm System ECR / ER CHANGE-OVER SWITCH Engine Room - local station A067.5032-100-0141

EOT system A067 The main purpose of sm electrics Engine Order Telegraph system is to generate the desired RPM or pitch value for the connected propulsion remote control system by a sustained and reliable lever known as well as human machine interface (HMI). In case the connected propulsion remote control system is disturbed the engine order telegraph system is in use to transfer manoeuvre commands to the engine control room or, if required, directly to the engine room s ME local station. The given manoevre command activates an audible alarm as long as the command has been accepted by corresponding operation at the connected participants. The modular system structure allows to extend the system by wing control units. All telegraphs located on the bridge e.g. bridge FWD, bridge AFT, wing SB, wing PS are connected to each other by a virtual mechanical shaft to make them work synchronously. That virtual shaft is called Electrical Shaft and oprerates as a remote control of the main bridge FWD telegraph which is providing the main interface to the connected propulsion remote control system. The centralized A067 mt-bus controller, mostly located inside the engine control room console, controls and monitors all network participants and provides further interface signals for ER call, VDR and connected IAMC systems. Your benefits intuitive operation reliable and economic mtbus-system easy to install - no on-site adjustments required highly integrated and modular system structure two handle types and two EOT sizes available twin EOT for twin main engine control available clear system diagnosis via central LCDisplay various interface technologies to your propulsion RC system serial VDR interface type approved by GL, BV, LR, RMRS, RRR

A067 mtbus controller sm electrics A067 mtbus controller is designed to manage and monitor permanently all connected network units. Simply to be mounted on a terminal rail (TS35) the controller provides useful system information to the commissioning, service and maintenance staff indicated clearly on a 4 lines 20 characters LC display. Following interface signals are provided: Wrong-way contacts, working with a correponding set of propulsion system contacts generating an alarm in case the given manoeuvre command and the current propulsion direction (propeller shaft or propeller pitch) do not correspond. EOT Call contact, causing the audible and/or visual alarm means to be activated in case the two connected EOT parties manoevre command do not correspond. Failure contact, causing an alarm to be transferred to the connected IAMC system or Bridge Alert Management system in case the mtbus controller detects an abnormal system situation. Serial VDR interface, RS 485, 2-wire / 3-wire uni-directional connection to VDR/S-VDR system acc. to IEC 61162-2. well established and sustained RS485 bi-directional mtbus technology power consumption: 2-3W to be installed on TS35 terminal rail LC display with 20 characters in 4 lines for system diagnosis VDR connection baud rate selectable 4.800 to 38.400bit/s Wrong-way contacts (dry relay contacts) EOT Call alarm (dry n/o relay contact) Failure contact (dry n/c relay contact)

A067 Bridge and ECR EOT sm electrics Engine Order Telegraph units are based on stainless steel material as well as on massive seawater resistant aluminium/magnesium alloy resulting in a long-term physical life. The EOT units can be down-graded to simple level drives providing only the desired RPM or pitch value to the connected propulsion remote control system. double engine order telegraph standard size, spade handle engine order telegraph standard size, ball handle The EOT units can be up-graded by an electrical shaft operation that synchronises all connected participants located on bridge wings and/or other bridge areas. In such operation mode the main EOT unit, mostly located on bridge centre, is providing the interface signals to the connected propulsion remote control system only. base material: Al Mg3 two handle types and two unit sizes available twin types for twin engine vessels available dimmable night vision operation various interface technologies to propulsion RCS synchronous operation of all bridge area units (electric shaft) protection rating: IP56 A067 Wing lever Engine Order Telegraph units located on the bridge wings are mostly provided without the typical EOT feature to transfer and receive the manoevre commands between bridge and engine control area. The simplified EOT is called lever and is part of the electrical shaft opeartion to remote control the main EOT unit on the centre bridge by synchronising all connected participants on the bridge area. Such follow-up technology gives full and reliable control to the OOW during bridge wing operation manoevres. wing lever small size, ball handle base material: Al Mg3 two handle types and two unit sizes available twin types for twin engine vessels available dimmable night vision operation synchronous operation of all bridge area units (electric shaft) protection rating: IP56

A067 full operation EOT repeater sm electrics Engine Order Telegraph unit installed at the main engine local station operates during EOT operation mode in correspondance with the main EOT on centre bridge. The manoevre commands from bridge are indicated visually incl. audible alarm and have to be acknowledged accordingly. The acknowledgement will be transferred to the bridge as a responding action. A simplified push button repeater version is available as well as an analogue indication and respond by round turning scale operation. telegraph repeater push button operation, In wall box with bell base material: Al Mg3 or powder coated sheet-steel push button control or round turning scale operation various interface technologies to propulsion RCS (e.g. redundant current transmitters 4-20mA) protection rating: IP44/IP56 telegraph repeater round turning scale operation, In wall box with bell round tourning scale operation to be flush mounted TECHNICAL SYSTEM DATA system power supply: 24VDC nominal A067 mtbus RS485 control two handle types and two unit sizes available double EOT for twin main engine control available VDR interface acc. to IEC 61162-2 various interface technologies to propulsion RCS all environmental tests min. acc. IEC 60945 full operation EOT repeater for ME local station protection rating: IP44/IP56 type approved by: GL, BV, LR, RMRS, RRR sm electrics GmbH Am Wulfsbarg 17 24217 Stakendorf Germany +49 (0) 4344 819 23-10 * info@sm-electrics.de EOT-bs-20170219