YO3 - YO4 / YL4 - YO5 / YL5

Similar documents
OPERATING AND INSTALLATION

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

4) Intrinsic Safety Certification

DB5 Intrinsically Safe Sounder Type DB-5

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

E2S Datasheet v10a

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL (ATEX / IECEx)

Explosion Proof Combination Signal db (A) / 5 Joule

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

INSTRUCTION & SERVICE MANUAL

Product Manual Standard Asserta Sounder Range

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

DICTATOR Hold-Open Systems for Hazardous Areas

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

DB1 Range - HORNS - Up to 103 db(a)

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

TX6831 Data Sheet. Features. Benefits

Technical Manual for the Horn - DB1PUL DB1HP UL

Fire Signalling. Signalling Solutions

Technical Manual for the Horn DB1P UL DB1HP UL

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

INSTRUCTION MANUAL (ATEX / IECEx)

Fire Signalling. Signalling Solutions

ATEX. IECEx. culs GOST-R. VdS

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

standards: standards:

X10 Mini, Midi & Maxi

CONTENTS NBM-06 Bell (6") Page 1

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range

14300 MAINS SEPARATOR ALARM MANUAL

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

INSTRUCTION MANUAL (ATEX / IECEx)

Fire Signalling. Signalling Solutions

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Web: LGM Products Ltd.

Technical Data. Dimensions

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

Excel-EN Conventional Fire Control Panel

RT FLOW RATE TOTALISER

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

XP95 Sounder VAD Base

AP200 SERIES INTELLIGENT ALARM DEVICES

Technical Data. Dimensions

Flameproof Manual Call Points

Conventional Fire Detection

Annubar Flowmeter Series

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Segnalatori acustici AW-ETH12MD AW-ETH12MD audible warning

Segnalatori acustici AW-ETH20MD Audible warning devices

MANUAL Overflow sensor NVF-104/34-PF

Emerald 3000 MK3 GJD010 Lighting Controller

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

EN54-23 Beacons & Sounder Beacons

Technical Data. General specifications. Rated operating distance s n 5 mm

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Power Supply Display Module PSDM. Installation and Operation Manual

Snifter ATEX22 VERSION. User Manual. Distributor

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Flameproof Manual Call Points Series MCP

AP200 SERIES INTELLIGENT ALARM DEVICES

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Tank Gauging System Special Safety Instruction

Analogue addressable devices

Intellia Sounder Bases and Sounder Beacon Bases

RE-PR3-E-27 3-Phase Panel Mount 27kW

Crowcon Gasmaster. 1 to 4 channel gas detection control panel. Installation, Operation and Maintenance Manual

INSTRUCTION MANUAL A131 High Level Audible Warning System

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

WARNING FIRE DOOR CLOSING

Fire & Security Products. Siemens Building Technologies Group

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

1510 Side Mounted Level Switch

Industrial Signalling

Universal Tank Alarm Type Installation, Operation & Maintenance

Emergi-Lite Orbis detectors

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

SOUNDER CONTROL MODULE SCM-AS4

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Transcription:

C l i f f o r d & S n e l l YO3IS YO4IS DIMENSIONS mm 81(3.2 ) 90(3.5 ) YO3 - YO4 / YL4 - YO5 / YL5 Intrinsically Safe Audible and Visual Alarms ATEX YO5IS YL4IS YL5IS 90(3.5 ) 81(3.2 ) MAIN FEATURES BASEEFA approved 2 stage alarm Rugged construction 32 selectable tones meeting international regulations Meets PFEER sound signals recommended by UKOOA Enclosure made from ABS flame retardant plastic Monitoring facility High sound output Stainless steel fixings Continuously rated Sound selection via DIL switch C Mounting: Via internal fixing holes E D 180(7.1 ) Model YO4 Models Y03 and YO5 Dim. For YO3 For YO5 Dim A 118 (4.7 ) 169 (6.7 ) Dim B 102 (4.0 ) 153 (6.0 ) Dim C 89 (3.5 ) 134 (5.3 ) Dim D 85 (3.4 ) 128 (5.0 ) Dim E 18 (0.7 ) 23 (0.9 ) Dim F 6 (0.2 ) 8 (0.3 ) CONFIGURATOR Unit Type Sounder YO3 A B C All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement. Sounder YO4 Sounder YO5 Combination Unit - YL4 European Approved Barriers (See application notes) Opto-coupled Temp Classification 57.5(2.3 ) Combination Unit - YL5 276(10.9 ) Model YL4IS 88(3.5 ) 88(3.5 ) 9(0.4 ) Model YL5 (dimensions not shown same as for YO5) Mounting: Via external lugs 2 x Ø F fixing holes M20 Cable mounting hole at Dim E TECHNICAL SPECIFICATION Relative humidity 95% @ 40 deg C Weight: YO3is 0.40Kg YO4is 0.49Kg YO5is 0.85Kg For use in zones 0,1,2 IP55 rated YO3, YO4 and YL4 IP56 rated YO5 and YL5 Volume control fitted on T4 class only Operating voltage 12Vdc, 18Vdc or 24Vdc via barriers Sound output YO3/4 100dB(A) @ 1 mtr Max YO5 105dB(A) @ 1 mtr Max European models ISC & ISD Operating temp 25deg C to 40deg C II 1G Ex.ia IIC, T4 or T6 YO3,YO4 and YO5 II 1G Ex.ia IIC, T4 YL4 and YL5 Voltage upper limit controlled by barrier D7277 Operating & Installation Instructions YO3,YO4 and YO5 D7441 Operating & Installation Instructions I.S. Beacons The PFEER sound signals recommended by UKOOA are: General Alarm Sound Signal 15 Interrupted tone 1000 Hz PAPA Sound Signal 31 Reverse Sweep 1200-500 Hz Toxic Gas Sound signal 11 Continuous Tone 1000 Hz APPROVAL SPECIFICATION European Standards Baseefa Certificate No. BAS02ATEX1190X YO3, YO4 and YO5 Baseefa certificate No. Baseefa08ATEX0194X YL4 and YL5 EN60079-0:2006 EN60079-11:2007 Lens Colour Red Flame Base Colour Red Normal (YL4 only) White (YL4 only) T4 Only YL4 YO3/4 YL5 YO5 YL4 YL5 YO3 YO4 YO5 YO5/YL5 YO3/YO4/YL4 Clifford & Snell - Member of the R.STAHL Technology Group Page 1 D8137-01

THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE CARRYING OUT ANY WORK ON THESE INTRINSICALLY SAFE ALARMS AN ATEX APPROVED APPROPRIATE BARRIER MUST BE USED BEFORE CONNECT- ING THESE UNITS TO ANY POWER SUPPLY THESE ALARMS SHOULD ONLY BE INSTALLED BY COMPETENT PERSONNEL These alarms are ATEX approved. Certification No: Baseefa08ATEX0194X CE0158 EX II 1 G - EEx ia IIC T4 No alteration to the unit i.e. PCB or pressure unit is allowed. In case if the unit becomes faulty, It must be returned to the factory. This equipment is designed and manufactured to protect against other hazards as defined in paragraph 1.2.7 of Annex II of the ATEX Directive 94/9/EC. SPECIAL CONDITION FOR SAFE USE: The apparatus has plastic enclosures which constitute a potential electrostatic hazard. The enclosures must be cleaned only with a damp cloth. Location: A suitable location must be selected with regard to the area to be covered by the sound signal and the beacon. The surface should be flat in the area of the fixings and the material suitable to carry the weight of the alarm. The case of the sounder shouldn t be put under any stress. Installation: The sounder and beacon must be independently wired with an individual ATEX approved appropriate barrier. Sounder Setup Sound Signal Selection: Sound signal selection is made by the setting of a PCB mounted DIL switch, located between the input and output terminals, as shown in diagram below: SOUND SELECTION SWITCH OPEN=0, CLOSE=1 VOLUME CONTROL Volume Control: A volume control giving approximately 15dB(A) adjustment is located besides the DIL switch on alarms with a T4 temperature classification. Page 2 D8137-01

SOUND SIGNALS, SOUND OUTPUT AND SUPPLY CURRENT First Sound Frequency Rept. Rate 2nd Stage Sound Output Input Stage Description Hz Signal Switches db(a) Current Signal 1 2 3 4 5 ma 1 alt. two tone 800-1000 0.5 3 1 1 1 1 1 100 26 2 2500-3100 0.5 4 0 1 1 1 1 102 34 3 800-1000 0.25 7 1 0 1 1 1 100 25 4 2500-3100 0.25 8 0 0 1 1 1 103 34 5 440-554 0.4/0.1 14 1 1 0 1 1 98 24 6 430-470 1.0 14 0 1 0 1 1 98 24 7 800-1000 0.13 12 1 0 0 1 1 100 25 8 2500-3200 0.07 13 0 0 0 1 1 102 34 9 440-554 2.0 10 1 1 1 0 1 98 24 10 Cont.tone 700-1 0 1 1 0 1 99 25 11 1000-31 1 0 1 0 1 98 24 12 1000-7 0 0 1 0 1 101 25 13 2300-2 1 1 0 1 1 101 30 14 440-9 0 1 0 0 1 98 24 15 In. tone 1000 2.0 31 1 0 0 0 1 97 24 16 420 1.25 30 0 0 0 0 1 97 24 17 1000 0.5 1 1 1 1 1 0 98 24 18 2500 0.25 4 0 1 1 1 0 101 30 19 2500 0.5 2 1 0 1 1 0 101 29 20 700 6/12 10 0 0 1 1 0 100 24 21 1000 1.0 32 1 1 0 1 0 99 24 22 700 4.0 10 0 1 0 1 0 99 24 23 700 0.25 10 1 0 0 1 0 97 23 24 720 0.7/0.3 10 0 0 0 1 0 99 24 25 Int.fast,rising 1400 0.25 26 1 1 1 0 0 101 28 26 fast siren 250-1200 0.085 11 0 1 1 0 0 99 24 27 rising cons 1000 10/40/10 17 1 0 1 0 0 100 25 28 iso 8201 evac 800-1000 as std 11 0 0 1 0 0 97 23 29 fast whoop 500-1000 0.15 32 1 1 0 0 0 99 25 30 slow whoop 500-1200 4.5 12 0 1 0 0 0 100 25 31 reverse sweep 1200-500 1.0 11 1 0 0 0 0 98 24 32 siren 500-1200 3.0 26 0 0 0 0 0 98 24 NOTES: The above sound output levels, switching rate and current consumption values relate to a typical YL5 sounder connected to 24Vdc supply via a suitable ATEX approved 28 Volts 300 Ohm d.c shunt diode For other Intrinsically Safe models i.e. YL4 the sound output is typically reduced by 2dB(A). For the same sounder connected to an 18 Volts or 12 Volts d.c supply via a 22 Volts 150 Ohm barrier respectively, the sound output level and current consumption figures will be reduced by 1-2.5dB(A), 1.5-5.0mA for 18Volts and 4.5-6.5dB(A), 9.0-14.0mA for 12 Volts supplies. Connection of two sounders in parallel to a single 24 volts d.c supply will reduce the sound output level by approximatly 3dB(A) and an input voltage tolerance to 10%. The recommended PFEER sound signals by UKOOA are as follows: General Alarm 1000Hz at 1.0 second intervals Signal number 15 PAPA Reverse sweep 1200-500Hz Signal number 31 Toxic Gas 1000Hz Continuous Note Signal number 12. Page 3 D8137-01

Sounder Connection Details and Line Monitoring An End Of Line (E.O.L) Resistor is required for Line Monitoring and it should be wire wound or metal film type with a resistance value of not less than 750 ohms, and power rating not less than 2 Watts, or not less than 4700 ohms, with power rating of not less than 0.4 Watts. The line monitoring facility allows the integrity of the line to the sounder to be monitored through the barrier to the control system fault detection and indication circuits. Two same type sounders can be connected in parallel. 1. Monitoring via Reverse Polarity Single Stage Alarm: 2nd Stage Alarm with a third wire: 2. Monitoring via Threshold (applied voltage <1V) 1st Stage: 2nd Stage: Page 4 D8137-01

Beacon Connection Details and Line Monitoring For a 24 Volts source, connect the unit via a suitable ATEX approved 28 Volts 300 Ohm dc shunt diode For an 18 Volts source, connect the unit via a suitable ATEX approved 22 Volts 150 Ohm dc shunt diode For a 12 Volt s source, connect the unit via a suitable ATEX approved 15 Volts 100 Ohm dc shunt diode Note: - Connection of two or more beacons in parallel to a single supply (via a suitable barrier) will slightly reduce the light output. Line Monitoring. An End Of Line Resistor (EOLR) is required for Line Monitoring. This should be of the wire wound or metal film type with a resistance value of not less than 750 Ohms and a power rating not less than 2 Watts or not less than 4700 Ohms with a power rating not less than 0.4 Watts. The Line Monitoring facility allows the integrity of the line to the beacon to be monitored through the barrier to the control system fault detection and indication circuits. Two or more, same type, beacons can be connected in parallel. FIRST UNIT SECOND UNIT FINAL UNIT 0V Ve EOLR ATEX approved BARRIER INTERMEDATE UNITS A GROUP OF R. STAHL, WALDENBURG, GERMANY R. STAHL (P) LTD., 2/397, MOOKAMBIKA NAGAR KATTUPAKKAM, CHENNAI 600 056, INDIA TEL: 91-44-24766674 / 24765713 FAX: 91-44-24767835 web: www.stahl.de Page 5 D8137-01