ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

Similar documents
DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ComfortNet -Compatible

GKS9 40" 90% Gas Furnaces

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

TECHNICAL INFORMATION MANUAL

GMS9/GCS9 SERIES 93% AFUE

Technical Information

GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal

AVPTC. Air Handler 1½ to 5 Tons

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Air Handlers 1½ to 5 Tons

Operator: Save these instructions for future use!

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL SPECIFICATIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

TECHNICAL INFORMATION MANUAL

TECHNICAL SPECIFICATIONS

AVPTC Multi-Position, Internal Txv

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

AMVM97 (B) / ACVM97 (B)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

50A Integrated Furnace Control

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

50A Integrated Furnace Control

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

TECHNICAL SPECIFICATIONS

Wt. Lbs Model Number (BTUH) Hz

RG7D 1-Stage Heat Series

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

40 Residential Gas Furnace Operation

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

MERIT SERIES Downflow

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

Operator: Save these instructions for future use!

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

Ruud Achiever Plus Series Multi-position Gas Furnaces

Operator: Save these instructions for future use!

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Operator: Save these instructions for future use!

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Rheem Classic Series Multi-position Gas Furnaces

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Operator: Save these instructions for future use!

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

MBR. Multi-Position. Modular Blower

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Multi-Position Gas Furnaces

Operator: Save these instructions for future use!

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Upflow/Horizontal Condensing, Gas-Fired Furnace

TSTAT0201CW Recommended (sold separately)

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

MULTI POSITION GAS FURNACE

Transcription:

ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart Silicon Nitride igniter Quiet single-speed draft inducer Self-diagnostic control board with constant memory fault code Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Multi-speed blower motor Low continuous fan speed options offer quiet air circulation California Low NOx emissions standards models available Cabinet Features Installation: dedicated downflow Convenient left or right connection for gas and electrical service Cabinet air leakage (Q Leak ) 2% Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram... 7 Accessories... 8 * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty (good for as long as you own your home) and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec SS-ADSH8 www.amana-hac.com 3/15 Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supercede 12/13

Nomenclature A D S H 80 040 3 A X A A 1 2 3 4 5,6 7,8,9 10 11 12 13 14 Brand A- Amana Configuration M - Upflow/Horizontal Minor Revision C - Downflow/Horizontal A - Initial Release K - Dedicated Upflow B - 1st Revision D - Dedicated Downflow Major Revision Motor A - Initial Release V - Variable Speed/ComfortNet B - 1st Revision E - High Efficiency S - Single Speed NOx N - Natural Gas Gas Valuve X - Low NOx M - Modulating C - 2 Stage Cabinet Width H - Convertible 2 Stage A - 14" C - 21" S - Single Stage B - 17½" D - 24½" AFUE Maximum CFM 97-97% AFUE 3-1200 CFM 80-80% AFUE 4-1600 CFM 5-2000 CFM MBTU/h 040-40,000 BTU/h 060-60,000 BTU/h 140-140,000 BTU/h 2 www.amana-hac.com SS-ADSH8

Specifications 0403A*A 0603A*A 0804B*A 1005C*A Heating Capacity Input 1 40,000 60,000 80,000 100,000 Natural Gas Output 1 32,000 48,000 64,000 80,000 LP Gas Output 1 32,000 48,000 64,000 80,000 AFUE 2 80 80 80 80 Available AC @ 0.5 ESP 3 3 4 5 Temperature Rise Range ( F) 25-55 30-60 35-65 40-70 Circulator Blower Size (D x W) 10 x 6 10 x 6 10 x 8 10 x 10 Horsepower @1075 RPM ⅓ ⅓ ½ ¾ Speed 4 4 4 4 Vent Diameter 3 4" 4" 4" 4" No. of Burners 2 3 4 5 Disposable Filter (in²)* 580 580 770 960 Electrical Data Min. Circuit Ampacity 4 8.5 8.5 12.9 12.9 Max. Overcurrent Device (amps) 5 15 15 15 15 Ship Weight (lbs) 88 92 106 114 1 Natural Gas BTU/h; for altitudes above from 0 to 5,500 above sea level, reduce input rating 4% for each 1,000 above 5,500 altitude. Low-fire rate is 75% of high-fire rate. 2 DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. * Permanent air filter size is based on 600 FPM velocity. Check with filter manufacturer for specific details Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-ADSH8 www.amana-hac.com 3

Dimensions Alt. Alt. Gas Inlet 1¾ 1-3/4 A B 1-7/16 1⁷ ₁₆ 27-7/8 27⅞ 33-3/8 33⅜ Alt. Gas Inlet High High-Voltage Inlet 20 23-5/16 23⁵ ₁₆ Alt. High Voltage Low-Voltage Voltage Inlet 13-1/4 13¼ Alt. LowVoltage 23 23¾ 3/4 28 Model A B Non-Combustible Floor Base 0403A*A 14 12½ SBT14 0603A*A 14 12½ SBT14 0804B*A 17½ 16 SBT17 1005C*A 21 19½ SBT21 Notes Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. Minimum Clearances to Combustible Materials Sides Rear Front¹ SW Vent² 1 0 3 6 1 1 ¹ 24 clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Note: approved for line contact in the horizontal position. Refer to the appropriate USA and Canadian codes: In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 B Top 4 www.amana-hac.com SS-ADSH8

Airflow Data (CFM & Temperature Rise vs. External Static Pressure) Model 0403A*A 0603A*A 0804B*A 1005C*A ¹ @ 0.5 ESP Motor Speed Tons AC¹ External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,353 --- 1,290 --- 1,246 --- 1,199 25 1,149 26 1,116 1,116 1,099 Med 2.5 1,183 25 1,113 27 1,098 27 1,052 28 1,039 29 1,006 1,012 969 Med-Lo 2 980 30 946 31 920 32 900 33 896 33 885 855 804 Low 1.5 778 38 762 39 738 40 746 40 738 40 717 696 678 High 3 1,290 34 1,236 36 1,194 37 1,166 38 1,176 38 1,166 1,108 1,029 Med 2.5 1,139 39 1,090 41 1,035 43 1,063 42 1,063 42 1020 962 895 Med-Lo 2 962 46 927 48 925 48 941 47 909 49 877 834 779 Low 1.5 787 56 776 57 763 58 744 60 723 --- 690 641 581 High 4 2,128 --- 2,063 --- 2,001 --- 1,927 --- 1,824 --- 1,726 1,628 1,529 Med 3.5 1,840 --- 1,788 --- 1,745 --- 1,689 35 1,625 36 1,550 1,470 1,364 Med-Lo 3 1,602 37 1,558 38 1,543 38 1,493 40 1,455 41 1,402 1,328 1,239 Low 2.5 1,277 46 1,252 47 1,244 48 1,229 48 1,214 49 1,179 1141 1079 High 3 2,405 --- 2,361 --- 2,250 --- 2,161 --- 2,037 36 1,937 1,808 1,689 Med 2.5 1,880 39 1,838 40 1,794 41 1,734 43 1,677 44 1,568 1,510 1,401 Med-Lo 2 1659 45 1,630 45 1,587 47 1,537 48 1,492 50 1,445 1,368 1,287 Low 1.5 1,472 50 1,454 51 1,404 53 1,366 54 1,326 56 1300 1228 1139 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, 400 CFM per ton for cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The dashed (----) areas indicate a temperature rise not recommended for this model. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. SS-ADSH8 www.amana-hac.com 5

Temperature Rise Range Chart 100 90 80 70 60 50 40 30 20 10 BTU/h Output Vs. Temperature Rise Chart 600 CFM 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM Formulas FORMULAS BTU OUTT = CFM x 1.08 x RISE BTU/h Output = CFM x 1.08 x Rise BTU OUTT RISE = BTU/H Output CFM Rise = 1.08 CFM x 1.08 30 40 50 60 70 80 90 100 110 120 130 140 150 Output BTU/h x 1,000 Temperature Rise 6 www.amana-hac.com SS-ADSH8

Wiring Diagram WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. XFMR (6) HUMIDIFIER GND INTEGRATED CONTROL MODULE 0 1 2 3 4 5 6 7 8 C HOT SURFACE IGNITER GR 0140F00662 REV. A STEADY ON = NORMAL OPERATION OFF 1 FLASH = = CONTROL FAILURE 4 FLASHES = OPEN HIGH LIMIT 24V 115V XFMR PRIMARY LIMIT ROLLOUT LIMITS (SINGLE CONTROL ON SOME MODELS) RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND FLAME SENSOR SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 2 FLASHES = PRESSURE SWITCH STUCK CLOSED 3 FLASHES = PRESSURE SWITCH STUCK OPEN 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE 7 FLASHES = LOW FLAME SIGNAL COLOR CODES: YELLOW OR ORANGE RPLE GR GREEN BLACK 10 7 8 4 1 LINE NEUTRAL 24 VAC HUMIDIFIER 11 5 2 C G R W Y 12 9 6 3 2 1 PK PINK OWN ITE BL BLUE GY GRAY RED DOOR SWITCH SWITCH LOCATED IN BLOWER COMPARTMENT ON SOME MODELS AUTO 1 STG 150 SEC XFMR-H LINE-H FUSE SEE NOTE 6 INTEGRATED CONTROL MODULE FS EAC-H PM C H I 1 3 2 2 STAGE GAS VALVE (HONEY WELL) 5 MIN 2 STG 100 SEC 2ND STG DLY MODE HT OFF DLY BL DIAGNOSTIC LED LO HEAT-H PARK 8 FLASHES = CHECK IGNITER OR IMPROPER GROUND BL OR BL HI HEAT-H COOL-H OR BL AUXILIARY LIMITS CICULATOR BLOWER (HI) BL (MED) OR(MED LOW) (LOW) (N) CAP 15 PIN PLUG ON SOME MODELS INDUCED DRAFT BLOWER COMPARTMENT BURNER COMPARTMENT NO BLOWER 24 VAC HUMIDIFIER C PRESSURE SWITCH 24V THERMOSTAT CONNECTIONS INTEGRATED CONTROL MODULE C G Y W R TO MICRO XFMR (3) XFMR-H FP LINE-H DOOR SWITCH INTERNAL TO INTEGRATED CONTROL IGN IND GND (8) MVC (9) MVH (12) MVL (2) PS (10) PSO (4) HLI (7) HLO (1) RO2 (11) RO1 (5) COOL-H HI HEAT-H WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. L JUNCTION BOX LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL PLUG CONNECTION AUXILIARY LIMIT CONTROLS 115 VAC FLAME SENSOR HOT SURFACE IGNITER ID BLWR CIRCULATOR BLWR C C2 HI M1 GAS VALVE ID BLOWER PRESSURE SWITCH NO MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON SOME MODELS) 24 VAC 40 VA TRANSFORMER JUNCTION BOX NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED EN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS ILE IN STANDBY(NO THERMOSTAT INTS). EAC-H GND CIR-N XFMR-N LINE-N OVERCURRENT PROTECTION DEVICE LINE-N GND LINE H LO HEAT-H TO 115 VAC/ 1/60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE ELECTRONIC AIR CLEANER N IGN-N IND-N EAC-N FIELD SPLICE SWITCH (TEMP.) SWITCH (PRESS.) AUTO RESET PRIMARY LIMIT CONTROL DISCONNECT EQUIPMENT GND FIELD GND IGNITER OVERCURRENT PROT. DEVICE INTEGRATED CONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. SS-ADSH8 www.amana-hac.com 7

Accessories Model Description ADSH8 0403A*A ADSH8 0603A*A ADSH8 0804B*A LPM-06 LP Conversion Kit (Springs & Orifice)¹ HANG21 High-Altitude Natural Gas Kit (5500+ ft) FTK04 Twinning Kit AFE18-60A Fossil Fuel Kit SBT 14/17/21 Downflow Sub-base ¹ Honeywell or White-Rodgers valves ADSH8 1005C*A Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2015 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 8 www.amana-hac.com SS-ADSH8