TM Series. Induced Draft, Counter Flow Optional Accessories

Similar documents
Paragon. Induced Draft, Counter Flow Optional Accessories

SECTION COOLING TOWERS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

SECTION COOLING TOWERS

AccuBrine automated brine maker Technical Specifications

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Indirect Gas-Fired Make-Up Air

Call us today! (800)

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

T-Series Air Conditioner T15 Model

Modular Supply Make-Up Air Unit

MAC N-407 Air-Cooled Chiller

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Water-Cooled Dual Compressor Screw Chiller

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

SYSTEM DESIGN REQUIREMENTS

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-Series Air Conditioner T53 Model

Aquatower STEEL COOLING TOWER. engineering data and specifications

Delta Cooling Towers, Inc.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Series 1500 Cooling Tower Specification

Call us today! (800)

Direct Gas-Fired Make-Up Air

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SECTION STEAM CONDENSATE PUMPS

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

JCseries EVAPORATIVE CONDENSER. engineering data

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

T-Series Air Conditioner T20 Model

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Technical Specifications & Pricing

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

MACH N-407 Heat Pump Air-Cooled Chiller

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

FDJ SERIES Jockey Pump Controllers Features

Temptek Auxiliary Equipment

MIST MAX MODEL MM800. Important: Installation and Operation Manual

SIMPLEX WEATHERPROOF CONTROL PANELS

CL64T INDUSTRIAL TOTE WASHER

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Condensate Boiler Feed Water Make-Up

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

ENGINEERING DATA AND SPECIFICATIONS. MH Fluid Cooler

E-4 Series. Cooling Towers USER GUIDE UGH

SECTION ROTARY-SCREW WATER CHILLERS

SECTION HEATING BOILER FEEDWATER EQUIPMENT

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Efficient, Long Lasting Evaporative Condensers

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Modular Heating & Ventilating Unit Model IGX-HV

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Call us today! (800)

Gate Operator. Modfications

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Installation & Operation

ULTRA-SAFE Explosion-proof Duct Heaters

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Liebert CSU3000 Chiller

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SECTION STEAM CONDENSATE PUMPS

Our Purifier systems

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

MIST MAX MODEL MM2400. Important: Installation and Operation Manual

Fluid Cooler Fan and Pump control panel

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

Hydra Negative Pressure, Closed-Loop Mold Temperature Controllers INSTRUCTION MANUAL

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

SECTION AIR COOLED WATER CHILLERS

XLP2 Evaporative Condensers

VENTLESS DOOR-TYPE DISHWASHER

Cooling Towers E1 Series

C44A/C44AW DISHWASHER

Transcription:

ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation. The option is provided when draining the system during periods of prolonged shutdown is not feasible, such as during weekends, or when a separate gravity feed indoor storage tank is not part of the re-circulation system. This package includes the following components: Immersion Heater: 6000 watt ~ 2.5 threaded connection ~ NEMA 4 enclosure For each two fan cell (450 gallon sump capacity) Thermostat Assembly: Thermostat is to be set in field. Recommended setting is approximately 38 F. NEMA 4 enclosure with SPDT switch ~ 30-130 F temperature range ~ 15A, 125-250- 460 VAC with ¾ Sch 80 bulkhead fitting and a ¾ x 1/3 Sch 40 reducer. Liquid Level Switch Assembly: NEMA 7 and 9 enclosures are standard on this SPDT level switch. This insures that the heating element is submerged prior to energizing to prevent immersion heater burn cause of low water level. Heater Contactor: NEMA 1 enclosure is standard. Open style for control panel mounting is available. This contactor is mounted in the control panel when the panel is purchased from Delta. PVC bulkhead fittings, for local installation, are included in component prices. Protection of external piping by heat tracing and insulation is recommended but not included. ANTIFREEZE PACKAGE / SOLENOID DRAIN VALVE This option is utilized when freezing of standing water in the cooling tower sump could occur due to system shutdown during winter operation. An electrically actuated valve will open when the pumps are not operating and the temperatures approach freezing. The valve can be installed in the sump drain fitting of the tower (at the factory) or remotely at the piping low point (by others in the field). Components provided are: A) Solenoid actuated to open, spring to close, 2-way valve, 1 line size, with NEMA 4 enclosure. B) 1 PVC tee C) 1 PVC plug D) Temperature switch with bulkhead fitting When power is removed the valve automatically reverts to the close position. BOTTOM OUTLET The Bottom Outlet is a convenient option when gravity draining a cooling tower. This minimizes the amount of standing water in the sump of the cooling tower. The sump of the TM Series cooling towers slopes toward the outlet and drain fittings to maximize drainage. The bottom outlet is placed at the low point in the sloped sump basin. A 125lb. flanged fitting is provided. Indoor storage tanks and other fittings can be provided by Delta.

CONTROL PANEL A control panel is required any time there are electrical devices involved in a system. The standard features of a Delta supplied control panel are: A) NEMA 3R water tight enclosure B) Single speed motor starter C) 110V transformer with fuses D) Blower operating lights E) Blower selector switches F) Terminal strips G) 208V or 230V or 460V or 575V / 3Ph / 60Hz Optional items available: Disconnect switch: either fused, unfused or magnetic circuit breaker type. Motor starter fuses or circuit breakers. Additional motor starters, selector switches and lights to interface with existing systems, remote pumps, etc. Any other NEMA enclosure manufactured. Pre-mounting of control panel and pre-wiring of skid mounted options with Liquid-Tite conduit or EMT. (Consult factory for add pricing) Delta also can provide programmable controllers, computer interfacing, telemetry, and any other type of control system required. Pre-mounting and pre-wiring of the control panel for a system installation are available. This minimizes the labor required for field installation. EQUALIZER FITTINGS This option is desirable for multiple 2 fan cell installations to provide equal liquid levels in the sumps of the individual 2 fan cells and allows for the installation of only one water make-up line. Delta provides the fittings installed in the cooling towers to provide for gravity flow from one tower sump to another. The equalizer connection is not for full flow transfer (ex: pumping from one unit to another). The connecting piping should be field installed and is the responsibility of others. FAN ASSEMBLY COATING The standard fan coating provided for the cooling tower fan ring and guards is a cross linked epoxyphenolic with an alkaline curing agent and formulated to withstand a wide range of chemicals and for ease of handling. This coating provides excellent chemical resistance to a wide range of acids, alkalies, solvent and water solutions. When dry, the coating can withstand up to 400 F temperature. The fan ring and guard steel surfaces are sand blasted and a primer is applied prior to the final application. HIGH SUMP LEVEL SWITCH The hump sump level switch option is utilized when a potential overflow must be avoided. Switch elevation is set below the point when the water in the sump will overflow onto the ground. The switch can be used to illuminate a light, shut off the influent feed pump or initiate some other device or alarm. This package consists of a NEMA 7 and 9 liquid level switch mounted in a PVC bulkhead fitting assembly with a 2 x 1 reducer bushing.

INSTALLATION The TM Series cooling towers can be set on a flat concrete pad or elevated on a pair of I-beams situated in the I-beam pockets molded into each two fan cell of the TM Series sump. The I-beams should be appropriately supported for the operating weight of the cooling tower plus, snow loads if applicable, and personnel responsible for maintenance. The TM Series cooling towers ship in 2 pieces: Main housing and the sump. The Main Housing is placed on the sump posts that fit up into the molded pockets in the housing. (Refer to the TM Installation, Operation and Maintenance manual) LADDER The ladder assembly facilitates access to the upper section of the cooling tower for inspection and maintenance of the water distribution system and fan assembly as required. The assembly is fabricated of aluminum for lightweight installation and has skid resistant rungs and landing platform. The landing platform is specifically placed to maximize accessibility to the man-way located in the conical section of the tower for easy access and servicing of components. The ladder conforms to all OSHA requirements. In some cases the cage assembly may be required. The unit is attached to the tower via (4) bolted connections and two base mounting bolts. Ladder extensions are available for elevated installation platforms. MOTOR SPACE HEATER Fan Motor Space Heaters are recommended for installations where temperature variations can cause excessive condensation within the motor. The Space Heater controls can be incorporated in our Control Panel and would be designed for automatic and manual operation. While the motor is operating, the heater remains off. When the motor shuts down, the heater is automatically energized during the off cycle. The Control Panel would be designed with manual on/off control for intermittent cycles of operation. Heaters are available for 115, 230, 460, or 550 volts, 3 phase, 60-cycle operation. OUTLET STRAINER BASKET This option is desirable to prevent debris that may have entered the cooling tower sump from getting into the pump, or the rest of the cooling water system. This option is recommended to minimize particle size that could foul chillers, heat exchangers, compressors or the cooling tower distribution laterals. A vortex breaker pipe, which is provided as standard on pump suction applications, is included to maximize the inlet area and prevent cavitation. The strainer is made from a vortex breaker pipe surrounded by 3/16 #2 PVC coated mesh screen. Finer mesh screens can be overlaid to minimize particle size. Consult Delta for add prices and availability. PUMP The pump package is offered to allow for single source responsibility of cooling tower equipment. The size of the pump is determined by two factors: A) Flow rate B) Total dynamic head The customer is responsible for supplying this information. The pumps come complete closed-coupled with mechanical seals and ODP, 208/230/460V, 3 phase motor. TEFC motors are available.

SAFETY CAGE Complementary to the ladder option. Extends above the ladder-landing platform for extra protection while accessing the top of the cooling tower. The safety cage is assembled to the ladder at the factory for ease of installation. This assembly is attached directly to the cooling tower shell during installation. The safety cage may or may not be required depending on OSHA specifications. The cage assembly is manufactured of the same type of aluminum as the ladder. THERMOSTATS Single Stage and Two-Stage The fan thermostat is important to minimize operating costs. The thermostat senses water temperature and controls fan operation during cold weather service. When cold-water temperature drops below design, the fan will shut off saving motor hp operating costs. A single stage thermostat controls the fan on/off and is provided with a standard single speed motors. A two-stage thermostat is required for two speed motor operation and controls the fan from on to half speed and then to off. At half speed operation the motor operates at only ¼ full load BHP. Two stage thermostats must be wired to Delta specifications. As the cold-water temperature rises and approaches the design temperature, the thermostat signals the fan to start in order to maintain the cold water design temperature. The thermostat has a 5 F differential in its operating range of 30 F to 130 F. The contacts are SPDT and have a 15 Amp UL rating. They are complete with NEMA 4 enclosures suitable for outdoor mounting. The thermostat can be provided loose, or installed in the cooling tower sump, or an indoor storage tank. When the thermostat is supplied with a cooling tower or storage tank provided by Delta, the package includes installation with a ¾ Schedule 80 PVC bulkhead fitting and a ¾ x ½ Schedule 40 PVC reducer bushing. Thermostat operating range must be set in the field. Recommended setting is approximately 70 F to 72 F, but will vary depending on the application and the installation location. TWO-SPEED FAN MOTOR Two speed fan motors provide cold-water temperature control by means of airflow modulation, allowing for design cold-water temperature at minimum operating cost. When provided with a two-stage thermostat, the motor can be reduced to half speed when cold water sump temperature approaches design. The motor will shut off when the cold-water temperature falls below design. Two-speed TEAO motors are provided for single voltage 3-phase operation only. Single-phase dual voltage motors are not available. NOTE: a ½ reduction in motor speed corresponds to ½ reduction airflow. At half speed operation, only 1/8 BHP is consumed. UPPER SAFETY HANDRAIL SYSTEM An optional safety handrail system is available to provide protection while on top of the cooling tower inspecting or working on the mechanical equipment. This option is shipped pre-fabricated for assembly in the field.

VIBRATION CUTOUT SWITCH The vibration cutout switch option is utilized to shut down the rotating mechanical fans in the event of excessive vibration. This device helps prevent further potential damage by shutting the motor off. It is wired in series with the motor starter coil and has dry contact rating of 10-ampere capacity at 120 VAC. Delta provides the vibration cutout switch installed on the blower when ordered as a component of a new cooling tower or on a replacement blower assembly.