Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Similar documents
Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Rotameter series 250 metal tube variable area flowmeter

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Technical Data. General specifications. Rated operating distance s n 5 mm

Inductive slot sensor

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

PEPPERL+FUCHS GmbH

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Beck. The differential pressure transmitter for air

Gas cylinder scale Model GCS-1

Technical Data. Dimensions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Technical Data. Dimensions

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Level gauges Series LS Level indicator, switch and transmitter for liquids

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Level Measurement Continuous level measurement Ultrasonic transmitters

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

Technical Data. Dimensions

VERSAFLOW VORTEX Supplementary instructions

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Ar-Mite TM Low Flow Armored Flowmeter

Ultrasonic Level Measurement nivopuls FDU 10 S

Dissolved Oxygen Analyzers

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Instrumentation Products and Applications

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Inductive Conductivity

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Fire & Security Products. Siemens Building Technologies Group

Model 144H. Product Data Sheet , Rev DB February Content

OPTIBAR P 1010/2010 C Supplementary instructions

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Mounting and Operating Instructions EB 2231 EN

Differential pressure sensors

Technology for life. Unit heater LH

Differential pressure gauge with electrical contact type Model: P650 series

UV Flame Supervision System

Flow Measurement SITRANS F C

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

SENSOR O2 O2-A

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Model 144H. Product Data Sheet , Rev DB February Content

Continuous Gas Analyzers, extractive

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

DICTATOR Hold-Open Systems for Hazardous Areas

InductIve SenSorS 2018

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Druck DPI 705/DPI 705 IS Series

OPTIBAR DP 7060 Supplementary Instructions

FSW300 Series Flow Switch

Process Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Temperature Measurement Transmitters for field mounting

WIO200 Water In Oil measuring instrument

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Gas expansion thermometer

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

DP86 Constant Voltage with Fitting

02/11/2015

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Brooks MT3750 Low Flow Armored Flowmeter

FAHM Co. Temperature Transmitter PTT74 Series

Level Electrode NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

89BSD Digital Output

The A-series Eletta Flow Monitor with local indication and analog output

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

System components for sample gas conditioning Sample gas cooler, gas feed unit, converter, accessories

CO warning instruments and gas spillage detectors

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Instruction Manual September 2010 SITRANS LVL200S

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SITRANS Pressure transmitter SITRANS LH300 (7MF1575..) Transmitter for hydrostatic level Compact Operating Instructions

industrial electronics electronic level measurement system

Transcription:

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids Differential pressure ranges from 0...4 40...3600 mbar Static pressures up to 40 bar Optionally with limit switch with two inductive alarm contacts. Optional measurements: Liquid level in pressure tanks, especially for cryogenic, liquefied gases Differential pressure between flow and return pipe Pressure drop across valves and filters Flow rate acc. to the differential pressure method Special features Suitable for liquids, gases and steam Limit switch can be easily retrofitted Overloadable on one side up to the perm. static pressure Suitable for field (degree of protection IP 54) and panel mounting Zero adjustment on the front Adjustment of measuring span 1:2 Housing of indicating unit with burst protection Directly connectable valve block (flange mounting) with test connection to check the pressure in the tank Connection for pressure switch Fig. 1 Media 5, Indicator 160 with attached valve block and operating pressure gauge Versions (Figs. 1 and 2) Media 5 consisting of: Indicator NG 160 with pointer mechanism Differential pressure cell (brass) PN 40 1) Version free of oil and grease for oxygen Measuring ranges from 4 3600 mbar ECO measuring diaphragm Zero adjustment on the front Process medium connection G 3/8 A Optionally equippable with: Scales Scale from 100% linear or squared; Scale according to DIN 19204; Detachable scales for different media; Special scales Inductive limit switch with up to three alarm contacts A1/A2/A3 (proximity switches) Version for hazardous locations Valve block directly flange mounted onto Media 5 devices Pressure gauge Screw joints Special versions available on request 1 2 Fig. 2 Media 5, Indicator 160 with limit switches and attached valve block with operating pressure gauge 1 Zero adjustment 2 Alarm contacts A1/A2 3 Valve block with pressure gauge and shut-off valves 4 Screw joints 3 4 1) Nominal pressure PN 50 available on request Associated Information Sheet T 9500 EN Edition September 1999 Data Sheet T 9519 EN

Principle of operation (Fig. 3) The differential pressure cell operates according to the deflection method and contains a ECO measuring diaphragm (1.5) which is designed to handle measuring spans from 4 3600 mbar. The diaphragm rod (1.7) is connected to a lever (1.8) and is supported and guided by the measuring springs. The lever leads the deflection of the measuring system out of the pressure chamber. The pressure chamber is sealed by means of a flexible disk (1.9). The measuring springs, which are connected to the housing, and the diaphragm ensure that the position of the lever is independent of the static pressure. The differential pressure cell can be overloaded from one side, because the measuring diaphragm flexes against the housing wall whenever the measured values are out of range. The differential pressure p = p 1 p 2 produces a force on the diaphragm (1.5) which is balanced by the measuring springs (1.4). The deflection of the measuring diaphragm and the lever (1.8) is proportional to the differential pressure measured and is converted to pointer (2.4) position with the adjustable transmission element (2.1) and the pointer mechanism (2.2) having jewelled bearings. The measuring springs (1.4) installed in the differential pressure cell determine the lower and upper limit of the respective measuring span (measuring range limit) of the device (see Table 2 "Technical data"). The span can be continuously adjusted within these limits of application according to the ratio 1:2 at the transmission element. This adjustment changes the transmission ratio between the lever (1.8) and the pointer mechanism (2.2). The measuring unit shaft (3.1) carries the metal tags (3.2) and moves them according to the operating direction into the limit switch unit with the two alarm contacts (proximity switches) A1 and A2 (3.3). If a metal tag enters the inductive field of the associated proximity switch, the switch becomes highly resistive (contact open). If the tag leaves the inductive field, the proximity switch becomes low resistive (contact closed). This function corresponds to that of a mechanical-type switching contact. The proximity switches are adjustable independent of one another and according to any user requirement. They provide a signal when the differential pressure either increases or decreases and the metal tags enter or leave the inductive field of the switch. The proximity switches have a LED indicator, allowing the limit values to be adjusted on site without any problems. Switching amplifiers (transistor relays) must be connected in the output circuit of the inductive alarm contacts A1/A2 in such a way that they meet the operational requirements of any connected control and signalling devices. 1.4 1.3 1.1 A1 p 2 ( ) (+) p 1 p 2 p 1 Fig. 3 Functional diagram of the indicator with 2 alarm contacts 1 Differential pressure cell 1.1 Housing of dp-cell 1.2 High pressure chamber 1.3 Low pressure chamber 1.4 Measuring springs (6 per measuring range) 1.5 Measuring diaphragm 1.6 Diaphragm plates 1.7 Diaphragm rod 1.8 Lever 1.9 Flexible disk A2 2.3 2.4 2.2 2.1 3.1 3.2 3.3 1.8 1.9 1.2 1.6 1.7 1.5 4.1 2 Indicating unit 2.1 Transmission element 2.2 Pointer mechanism 2.3 Scale 2.4 Pointer 3 Limit switch 3.1 Measuring unit shaft 3.2 Metal tags 3.3 Alarm contacts A1/A2 4 Valve block 4.1 Valve block with pressure gauge, shut-off valves, screw joints and test connection 2 T 9519 EN

Limit switch (alarm contacts A1, A2, A3) Proximity switches (NC, normally closed) Metal tag outside inductive field Switching signal "ON" (L-signal of the proximity switch) - Function: contact closed or output activated - Low resistive (undamped), power consumption 3 ma Adjustment range 1.1 Alarm contact A1 Adjustment range 1.2 1.2 1.1 2.1 2.2 Adj. range 2.1 Alarm contact A3 Adj. range 2.2 Alarm contact A2 Metal tag inside inductive field Switching signal "OFF" (0-signal of the proximity switch) - Function: contact open or output disabled - Highly resistive (damped), power consumption 1 ma A1 = 1st min. contact A2 = 2nd min. contact A3 = max. contact Fig. 4 Limit switch with 3 alarm contacts in the indicating unit Table 1 Functions of the alarm contacts A1 and A2 Overview of functions Proximity switch for... Tapping of gas (min. contact) Adjustment ranges Filling of tank (max. contact) Alarm contacts A1 A2 A1 A2 Metal tag inside field 1.2 2.1 1.1 2.2 Metal tag outside field 1.1 2.2 1.2 2.1 Limit switch with 2 alarm contacts - Terminal assignment - LED1 LED2 41 42 51 52 Table 2 Functions of the alarm contacts A1, A2, A3 Overview of functions Proximity switch for... Adjustment ranges Tapping of gas (2 min. contacts) Filling of tank (1 max. contact) Alarm contacts A1 A2 A3 Activation when metal tag inside field 1.2 2.1 2.2 Switching points Min. contacts when indication decreases Max. contacts when indication increases + + A1 A2 Fig. 5 Terminal assignment of A1 and A2 Limit switch with 3 alarm contacts - Terminal assignment - LED1 LED2 LED3 Table 3 Technical data for limit switch in type of protection EEx ia IIc T6 Maximum values for connection to certified intrinsically safe circuits U 0 16 V I K 52 ma P 169 mw Max. values at terminals 41/42; 45/46; 51/52 Effective internal inductance L i 250 µh Effective internal capacitance C i 50 nf Temperature class T6 T5 T4 Perm. ambient temperature 60 C 75 C 80 C 41 42 51 52 45 46 + + + A1 A2 A3 Fig. 6 Terminal assignment of A1, A2, A3 3 T 9519 EN

Table 2 Technical data All pressures in bar or mbar (gauge) Differential pressure meter Measuring range mbar 60 100 160 250 400 600 1000 1600 2500 3600 1) Measuring span min. 5 8 125 to 20 30 50 80 125 200 4 60 max. 100 160 250 400 600 1000 1600 2500 3600 Nominal pressure PN 40 1), overloadable on one side up to 40 bar Indicator 160 Performance Indicator linear to differential pressure Terminal-based non-conformity < ± 2.5 % < æ1.6 % (including hysteresis) Sensitivity < 0.5 % < 0.25 % Effect of static pressure < 0.03 % / 1 bar Limit switch unit Max. 3 alarm contacts A1/A2/A3 with proximity switches and LC display (acc. to Namur and DIN 19234) Control circuit Rating according to the connected transistor relay 2) Proximity switch 3) Type SJ 3.5N-LED 4) Switching accuracy < ±2 % Range of inversion, approx. < 0.6% Perm. ambient temperature range for oxygen 4 +80 C 4 +60 C Perm. storage temperature range 4 +100 C Degree of protection acc. to DIN 40 050 IP 54 Weight Without valve block With valve block Approx. 3.0 kg Approx. 5.0 kg 1) Oxygen version for nominal pressure of up to PN 50 available on request. 2) For example WE77/Ex 2 or from the K system KFA6-SR2-Ex2.W. 3) Proximity switches can be used in hazardous areas, corresponding to the Certificate of Conformity PTB No. Ex-95.D.2195X. 4) Other limit switches available on request. Note: All errors and deviations are given in % of the adjusted measuring span. For flow measurement, see Data Sheet T 9550 EN. The technical data related to the special version are the same as for the standard version. Table 3 Materials (WN = Material Number according to DIN) Version Standard version Special version Housing of differential pressure cell Cu Zn 40 Pb CrNi-steel Measuring diaphragm and seals ECO Measuring springs Diaphragm plates and function parts CrNi-steel Lever Housing of indicating unit Polycarbonate 4 T 9519 EN

Installation (see Fig. 6) Tube mounting - With mounting device and clamp for attaching to a vertical or horizontal 2" tube. Wall/panel mounting Through two M 8 tapped holes located in the valve block or on the rear cover of the dp-cell. Panel mounting With either cheese head screws M 4 and thread M 4 in the panel or hexagon head screws with M 4 nuts (see Fig. 7/panel mounting). Process medium connection: Tapped hole ISO 228 G 3 8. Installation and dimensions in mm Tube mounting 156 92 Mounting device Vertical tube Horizontal tube Clamp 200 55 147 297.5 31 Press. gauge NG 100, AB-Wesel Dimensions in mm Safety version a b S1 EN 837-2 55 97 S3 EN 837-2 60 92 SW17 b a Wall mounting Panel mounting Panel cut-out Ø 180 +0,2-0,3 Center line of the indicating unit 30 30 30 158.5 43.5 Holes 8.5 for fastening screws M 8 Ø 165 +5 Cut-out 52 Six tapped holes M 4 or holes with 4.5, for hexagon head screws with nuts M 4 Option of using either 3 x 120 or 4 x 90. Fig. 7 Dimensions 5 T 9519 EN

Ordering text Differential Pressure Meter/Flow Meter Media 5 Nomenclature for ordering: - Complete the order number according to the instrument version chosen - Instrument version Order No. 5 0 0 5 A - Media 5, dp cell CuZn40Pb2 0 Media 5, dp cell WN 1.4571 1) 1 Standard version 0 Version free of oil and grease for oxygen 2) acc. to standard 1.34-2, Page 1 1 Measuring range Measuring span Min. Max. 0... 60 mbar 40 mbar 60 mbar 0 2 0... 100 mbar 50 mbar 100 mbar 0 3 0... 160 mbar 80 mbar 160 mbar 0 4 0... 250 mbar 125 mbar 250 mbar 0 5 0... 400 mbar 200 mbar 400 mbar 0 6 0... 600 mbar 300 mbar 600 mbar 0 7 0... 1000 mbar 500 mbar 1000 mbar 2 0 0... 1600 mbar 800 mbar 1600 mbar 2 1 0... 2500 mbar 1250 mbar 2500 mbar 2 2 0... 3600 mbar 2000 mbar 3600 mbar 2 3 Zero adjustment screw with zero point correcting screw (standard version) 0 with covered zero point correcting screw 1 Limit switch unit 3) without limit contacts 0 with 2 inductive limit contacts, Type SJ 3.5N-LED with 3 inductive limit contacts, Type SJ 3.5N-LED 2 3 Additionally required order specifications Measured value adjustment 4) Unit adjusted to:... mbar Additionally required order specifications Alarm contacts Contact A1 Contact A2 Contact A3 Min. contacts = measured value decreases Metal tag is inside outside inside outside inside outside Max. contacts = measured value increases For measured value 1) Special version available on request. 2) Version for oxygen up to nominal pressure PN 50 on request. 3) For limit switch unit from factory. Standard: without adjustment. 4) For measured value adjustment from factory. Standard: 0... max. measured value. For switching value...mbar... mbar... mbar Scale version required (see T 9545 EN), Accessories: valve block, pressure gauge, screw joints (see T 9555 EN) Specifications subject to change without notice. 1fNORMAL.STY@ADRESSE = SAMSON AG MESS- UND REGELTECHNIKWeismüllerstraße 3 D-60314 Frankfurt am MainTelefon (0 69) 4 00 90 T 9519 EN