Mounting and Operating Instructions EB 2231 EN

Similar documents
Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Series 1140 and 1141 Temperature Regulators

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

13-1. Temperature Regulator

Frost Protection Thermostat

Installation S

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

MINIATURE THERMOSTATIC VALVE

Installation S

INSTALLTION FOR THERMOSTATIC VALVES

Installation S

Blue Ribbon Corporation

Installation S

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

INSTALLATION FOR THERMOSTATIC VALVES

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Installation Guide COMBI. Before installing read this guide first

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Powers TM Controls TH 188 Unit Mounted Thermostat

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

TEMPERATURE CONTROLLERS

TK-1001, 1101, 1201, 1301, 1601

Thermometers Installation, Operation and Maintenance WINTERS INSTRUMENTS. MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

BioMaster 250/350/600 BioMaster Thermo 250/350/600

Temperature Sensor TRG Original Installation Instructions English

Grohtherm Grohtherm 1000

Gas expansion thermometer

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

INSTANT HOT WATER DISPENSER

TA-MATIC

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

Getting Started Quick Reference Guide

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Thermostatic valves with radiator connection systems

TK-1801, TK-1811 TK-1801, TKR-1811

DEVIATING VALVES ART K063

STAND ALONE DRYER BASE. Parts Manual

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

SERVICE MANUAL WASHING. Washer-dryers HEC-RIM HEC-ARCHED. Structural characteristics, electrical components, accessibility

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Instructions for Installation, Operation, Care and Maintenance

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Installation S

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

CORALAIS BODYSPA BATH AND SHOWER FAUCET

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

INSTALLATION INSTRUCTION

Vent Supplement Ultra-80, -105, -155, -230 & -310

1592P01. for liquids in piping DN

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Installation guide. Before installing read this guide first

Brawa-Mix Thermostatic mixing valves

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

CEILING FAN OWNER'S MANUAL

FSW300 Series Flow Switch

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

A19, A28 Series Thermostats for Agricultural Buildings

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Install Guide 8046 ENGLISH. Customer Support: or: visit our website Printed in China ON.

Mechanical seals external, single or double, to DIN EN 12756

Installation guide COMBI. Before installing read this guide first

INCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL

T834C Heating-Cooling Thermostat

Installation Instructions

Astro Express 2 - Hot Water Delivery System

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Problem-solvers The Radiator Solution Range

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Level Electrode NRG NRG Original Installation Instructions English

SECTION METERS AND GAGES FOR HVAC PIPING

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /06.12

Thermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers

Thermotech underfloor heating

Transcription:

Self-operated Regulators Thermostats Type 223 and Type 2232 Bulb Sensors Type 2233, Type 2234, and Type 2235 Air Sensors Type 223 with bulb sensor Type 2232 with bulb sensor (separate) Type 2233 with air sensor Type 2233 with perforated cover Type 2234 with bulb sensor (separate) and clamp (on the set point adjuster) Type 2234 with air sensor and clamp Type 2235 with freely installable air sensor and clamp (on the set point adjuster) Mounting and Operating Instructions EB 223 EN Edition May 206

Note on these mounting and operating instructions These mounting and operating instructions assist you in mounting and operating the device safely. The instructions are binding for handling SAMSON devices. For the safe and proper use of these instructions, read them carefully and keep them for later reference. If you have any questions about these instructions, contact SAMSON s After-sales Service Department (aftersalesservice@samson.de). The mounting and operating instructions for the devices are included in the scope of delivery. The latest documentation is available on our website (www.samson.de) > Product documentation. You can enter the document number or type number in the [Find:] field to look for a document. Definition of signal words! DANGER Hazardous situations which, if not avoided, will result in death or serious injury! WARNING Hazardous situations which, if not avoided, could result in death or serious injury! NOTICE Property damage message or malfunction Note Additional information Tip Recommended action 2 EB 223 EN

Contents Design and principle of operation...3 2 Installation...4 2. Types 223 and 2232 (bulb sensor)...4 2.2 Types 2233, 2234, and 2235 (air sensor)...6 2.3 Capillary tube...6 2.4 Operating element...7 3 Operation...7 3. Adjusting the set point...7 3.2 Correcting the set point dial...7 Design and principle of operation The thermostat is used in combination with a control valve to regulate the temperature. The thermostat can be fastened directly to the control valve or using a double adapter. A double adapter with or without locking facility allows a further thermostat to be connected to achieve additional temperature regulation or limitation. The thermostat comprises the temperature sensor, set point adjuster, capillary tube, and operating element. Depending on the field of application, the versions shown on the front cover can be selected. The thermostats operate according to the liquid expansion principle. When, for example, the temperature at the temperature sensor (9) increases, the liquid contained in the sensor expands, causing the pin (9) of the operating element to be pushed upward by the bellows (0). This travel motion acts on EB 223 EN 3

Installation the plug stem of the connected valve and moves the valve plug until the temperature reaches the adjusted set point. The temperature set point can be adjusted using a key (2). By turning the key, a spindle moves the piston (8) up or down, causing the volume of the liquid contained in the sensor (9) to change. As a result, the valve plug moves within its operating travel according to the adjusted set point within a higher or lower temperature range measured by the sensor. Typetesting The Types 223 to 2235 Control Thermostats have been tested together with control valves by the German Technical Inspectorate (TÜV) in accordance with DIN EN 3440. The register number is available on request. EAC compliance The thermostats bear the EAC mark of conformity. 2 Installation 2. Types 223 and 2232 (bulb sensor) Bulb sensors are used to measure the temperature of liquids. They are designed for installation in pipelines, heat exchangers, boilers, baths, tanks, etc. Installation recommendations Select the place of installation ensuring that the sensor is installed as close as possible to the heat source, but avoid exposing it to overheating. When mounted in a boiler, we recommend installing the sensor in the top third of the boiler. When mounted in a counterflow heat exchanger, we recommend installing the sensor in a pipe elbow, directly behind the pipe end socket piece. In plants with only temporary heat consumption, a circulation pipe must be provided when the regulator is mounted on a counterflow heat exchanger to ensure that the sensor can respond to temperature changes in the counterflow heat exchanger even when no water is tapped. Installation Weld on a pipe socket with female thread (socket-weld design) of approx. 40 mm in length at the place of installation (this also applies when a thermowell is used). Remove the double nipple (7) or thermowell (if used) from the sensor (9) and seal it into the welded socket. Adjust the highest possible set point on the set point dial (3) using the key (2). Insert the sensor with seal into the double nipple or thermowell. Secure it with the coupling nut (6). The entire length of the temperature sensor (9) or thermowell must be immersed in the process medium. 4 EB 223 EN

Installation 2 3 Control valve, double adapter or reversing device 7 8 9 0 5 6 7 9 8 4 7 Coupling nut 8 Operating element 9 Pin of operating element 0 Operating bellows Capillary tube 2 Key 3 Set point dial 4 Spindle 5 Excess temperature protection 6 Coupling nut 7 Double nipple 8 Piston 9 Temperature sensor Fig. : Sectional drawing Type 2 Configuration ID 3 Date SAMSON 2 3 Gr. 6 DN 7 8 x bar C 4 bar C 5 Made in Germany 4 Limit 5 TÜV or DIN number 6 Size 7 Valve size 8 Pressure or temperature range Fig. 2: Nameplate EB 223 EN 5

Installation Thermowell: When a thermowell is used, we recommend filling the free space between sensor and thermowell with oil or, when installed horizontally, with grease or any other heat transfer medium to avoid delays during heat transmission. Observe the thermal expansion of the filling medium. Do not fill the entire free space or slightly loosen sensor nut for pressure compensation.! NOTICE Galvanic corrosion due to incorrectly selected materials of the mounting parts. On installing the sensor or thermowell, only combine the same kind of materials (e.g. stainless steel with stainless steel or copper together with other copper materials). 2.2 Types 2233, 2234, and 2235 (air sensor) Types 2233 and 2234 are designed for installation in air heaters, air ducts, drying cabinets, etc. Install the sensor from the outside into the room and secure it with a special clamp (accessories). The entire length of the sensor must be immersed in the air flow to be regulated. For Type 2234, install the set point adjustment in an easily accessible location. Avoid locations with considerable ambient temperature fluctuations. Type 2233 with perforated cover is generally used for installation in manufacturing facilities, living spaces, baths, etc. Installation recommendations Mount the sensor protected by a perforated cover to a suitable location, if possible in the middle of the wall. Type 2234 with clamps (or perforated cover) is suitable for installation in drying chambers, dryers, air heaters, incubators, etc. In case of forced air circulation, install the sensor near the supply air inlet. Mount the set point adjustment outside the room to be controlled in an easily accessible location. The set point adjustment must be exposed to a temperature that is as constant as possible. Type 2235 is equipped with a temperature sensor to be calibrated on site. This allows the measurement of almost all temperature layers. Make sure the set point adjustment for this sensor is installed outside the room to be controlled in an easily accessible location. Avoid locations with considerable ambient temperature fluctuations. When regulating the temperature in greenhouses, make sure that the thermostat and set point adjuster are not exposed to direct sunlight. When the temperature regulating system is shut down during the summer, adjust a high set point to protect the thermostat. 2.3 Capillary tube Carefully run the capillary tube () without bending or twisting it and do not expose to any temperature fluctuations, if possible. 6 EB 223 EN

Operation! NOTICE Risk of malfunction due to capillary tube damage. Do not damage or shorten the capillary tube. Roll up excess tube to form a ring (smallest bending radius = 50 mm). 2.4 Operating element Attach the operating element (8) to the valve body or double adapter using the coupling nut (7). 3 Operation 3. Adjusting the set point Only use the key (2) to adjust the required temperature set point at the set point dial (3). Slowly turn the key clockwise to increase the temperature and counterclockwise to reduce it. Read off the temperature at the reference thermometer of the plant and readjust with key, if necessary. 3.2 Correcting the set point dial Due to special conditions on site, the temperature adjusted at the set point dial might not be the same as the reading at the reference thermometer. If this is the case, proceed as follows: Undo the screw labeled "Korrektur" on the back of the dial housing. Turn the entire dial housing until the dial shows the same temperature as the reference thermometer. Turn clockwise to increase the set point and counterclockwise to reduce it (viewed from the front with the dial housing on top). A 360 turn corresponds to a set point change of approx..5 C. Note Higher set point temperatures can be adjusted in increments as required. However, to lower the set point temperature, proceed in steps of 0 to 20 C. When doing so, wait for the process medium to cool down before continuing (watch the thermometer). EB 223 EN 7

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 6034 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-507 samson@samson.de www.samson.de EB 223 EN 208-03-28 English