TECHNICAL. Series 18. Pump Packages

Similar documents
B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SECTION PLUMBING EQUIPMENT

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

University of Delaware

BuildingName The Description of the Project P DOCUMENTS

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

SECTION PACKAGED HEAT TRANSFER SYSTEM

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS

SECTION PLUMBING EQUIPMENT

Water Piping and Pumps

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

UNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

A. This Section includes the following domestic water piping specialties:

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

dualarm Vertical In-Line Pumps

MARLOW PUMPS RECIRCULATION

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

SECTION HYDRONIC PIPING AND SPECIALTIES

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION HEATING BOILERS

Silhouette. Feedwater Heater. Boiler Feedwater

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

Hoffman Specialty Pump Products

PROJECT NAME: DPW Idaho State University Liberal Arts Building Chiller Replacement

.2 Section Waste Management and Disposal.

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

SECTION CHILLERS

Product Chillers A P P L I C AT I O N S

Hard-hitting Contenders In HVAC Fluid Handling Solutions

Wilo IL Vertical Split-Coupled Inline Pumps

SECTION HYDRONIC PIPING SYSTEMS. 1. Pipe and pipe fittings are specified in the following sections:

CLOSED COUPLED CENTRIFUGAL PUMPS

References are in agreement with UMRL dated April 2018 **************************************************************************

SECTION HEATING AND AIR CONDITIONING PIPING SYSTEMS. A. Provisions of Division 01 apply to this section. 1. Chilled Water System.

POULTRY MARKET CATALOG

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

PACKAGED AIR COOLED Product Data Catalog

GLOBAL FLOW PRODUCTS

SECTION METERS AND GAGES FOR HVAC PIPING

5. CONDENSATE PUMPS/UNITS

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

4. Provide brass valve tags marked for the service. See pertinent service specification for valve type.

Peerless Pump Company

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

FEATURES. Other Fed-Flush Arrangements

KEENER GRINDER PUMPS

Deaerator. Specifications

In-Line Air Separators

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

Mission Critical. Fuel Supply Systems

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

SECTION METERS AND GAGES FOR PLUMBING PIPING

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

Polymer Dilution Blend and Feed Specifications For General Use

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

SECTION HYDRONIC PIPING

SECTION SECTION DESIGN REQUIREMENTS

SECTION STEAM CONDENSATE PUMPS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX

Custom Design TYPE CS

Condensate Boiler Feed Water Make-Up

Transcription:

TECHNICAL S Y S T E M S Series 18 Pump Packages

Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump Pump selector switch on dual pump packages only Mounted and wired paddle-type flow switch Isolation valve on suction side of pump (ball-type valve through 2 1/2" pipe size, butterfly-type valve 3" pipe size and up) Strainer installed on suction side of pump (wye strainer through 3", basket strainer 4" and up) Vertical scale Fahrenheit thermometers Dial-type differential pressure gauge with shutoff valves across the pump Dielectric unions at each dissimilar metal connection 1/2" closed cell insulation on all piping and components Structural steel base rail configuration Corrosion resistant epoxy coating NEMA 3R hinged door control panel with UL 508 label Automatic switchover to standby pump based on flow or overload failure (dual pump packages only) NOMENCLATURE Model 18PPS-20 Series S = Single D = Dual T = Triple M= Multiple Maximum GPM TECHNICAL S Y S T E M S DIVISION RAE CORPORATION 2

Optional Features Weatherproof cabinet with removable access or hinged access panels for outdoor installation with vestibule lights Base mounted pumps, in-line pumps, turbine pumps PVC piping Tangential or in-line air separators mounted Expansion tanks: diaphragm or compression type mounted and precharged Triple duty tanks: providing mass, air separation, and expansion for system Mass storage tanks: vented to atmosphere or pressurized, ASME stamped or non-code Variable frequency drives for pumps, mounted and wired Non-fused or fused disconnects Alarm circuits for pump failure Pressure regulating valves Glycol feed tanks with or without feeder pumps Chemical injection feeder pump systems Jacketed pipe insulation 3

Series 18 Pump Packages TECHNICAL S Y S T E M S DIVISION RAE CORPORATION Technical systems has manufactured pumping systems that have been packaged on our chillers systems for over 20 years. We apply our technical and manufacturing expertise to our stand-alone pump systems as well. Whether the application is for chilled water systems, hot water systems, condenser loops, ground water systems, or process flow, Technical Systems will build a pump skid to meet your specifications. Maintaining Excellence in Engineering Integrating the mechanical refrigeration and pumping systems requires excellent engineering supervision. Where most manufacturers of pumping systems fail to look beyond their equipment, Technical Systems works to make sure the equipment built for the customer can be easily integrated with the system. One of the biggest problems in a chilled water pump system is the issue of system volume. Insufficient system volume will result in poor control of chilled water set point and inefficient operation of equipment. As a solution, Technical Systems will package mass storage tanks, either open or pressurized, to provide sufficient volume. These tanks can serve as a buffer, or serve as an intermediate blending tank when dealing with water temperatures higher than the normal ranges of chillers in process applications. Meeting Your Needs Being a manufacturer of customized equipment, Technical Systems must be flexible to meet customer needs. Although we use certain manufacturers of pumps and hydronic accessories in standard packages, we will consider any application that requires a specific component or system to meet your needs. Along with our standard features, the optional capabilities allow you to customize the pump package to meet the project scope. Whether it requires a weatherproof cabinet for outdoor installation, variable frequency drives for primary/secondary systems, expansion tanks for boiler systems or chilled water systems, or mass tanks to provide for a more efficient system, Technical Systems has a pump package that will fit your needs. Technical Systems Builds Equipment to One Set of Specs Yours! 4

STANDARD PUMP PACKAGE VERTICAL SCALE TERMOMETER PI PRESSURE GAGE DIELECTRIC UNION SHUT-OFF VALVE FLOW SWITCH DIELECTRIC UNION TRIPLE-DUTY VALVE (Isolation, check & balance) PUMP #1 STRAINER PI PRESSURE GAGE DIELECTRIC UNION SHUT-OFF VALVE Used in Dual Pump Arrangements TRIPLE-DUTY VALVE (Isolation, check & balance) PUMP #2 STRAINER 5

Series 18 Single Pump Package Model Number PPS-20 PPS-45 PPS-80 PPS-130 PPS-200 PPS-350 PPS-600 PPS-800 1 Discharge water lines are sized for velocities between 8 feet/sec. and 12 feet/sec. 2 Dimensions are for indoor installations. Outdoor weather proof cabinet may increase unit dimensions. Consult factory. 3 Dimensions and connections are for basic pump package only. Addition of expansion tank, air separator, mass tanks, or some other component will affect unit foot print and/or connection type. 4 Total head includes a 15' internal drop for pump package. 6

Double Pump Package Model Number PPD-20 PPD-45 PPD-80 PPD-130 PPD-200 PPD-350 PPD-600 PPD-800 1 Discharge water lines are sized for velocities between 8 feet/sec. and 12 feet/sec. 2 Dimensions are for indoor installations. Outdoor weather proof cabinet may increase unit dimensions. Consult factory. 3 Dimensions and connections are for basic pump package only. Addition of expansion tank, air separator, mass tanks, or some other component will affect unit foot print and/or connection type. 4 Total head includes a 15' internal drop for pump package. 5 Pumps are designed for 100% redundant, primary/standby operation. Pumps will not operate simultaneously. 7

Series 18 Pump Package Specification GENERAL REQUIREMENTS Balance: Rotating parts, statically dynamically. Construction: To permit servicing without breaking piping or motor connections. Pump Motors: Operate at 3500 RPM unless specified otherwise. Pump Connections: Flanged Furnish and install pumps with capacities as specified herein. Pumps shall be end suction type, single-stage, close coupled for installation in horizontal position, and capable of being serviced without distributing piping connections. Pump volute shall be Class 30 cast iron with integrally cast pedestal support. The impeller shall be cast bronze, enclosed type, dynamically balanced, keyed to the shaft and secured by a locking cap screw. The liquid cavity shall be sealed off at the motor shaft by an internally-flushed mechanical seal with ceramic seal seat of at least 98 percent alumna oxide content and carbon seal ring, suitable for continuous operation at 225 F. A replaceable bronze shaft sleeve shall completely cover the wetted area under the seal. Pumps shall be rated for minimum of 175 PSI working pressure. Casing shall have gauge ports at nozzles and vent and drain ports at top and bottom of casing. Pump bearing housing assembly shall have heavy-duty re-greasable ball bearings, replaceable without disturbing piping connections and have foot support at coupling end. The motor shall meet NEMA specifications and shall be the size, voltage, and enclosure called for on the plans. Pump and motor shall be factory aligned. Provide access space around pumps for service. Provide no less than minimum as recommended by pump manufacturer. Ensure pumps operate at specified system fluid temperatures without vapor binding and cavitation, are non-overloading in parallel or individual operation. Pumps shall be manufactured by ITT Bell and Gossett, Scot, MEPCO, or approved equal. TRIPLE DUTY VALVE Furnish and install as specified, a valve designed to performs the functions of a non-slam check valve, throttling valve, shut-off valve, and calibrated balancing valve. The valve shall be of heavy-duty cast iron construction with NPT connections per ANSI B1.20.1-83 suitable for 175 psi working pressure for operating temperatures up to 250 F. The valve shall be fitted with a bronze seat, replaceable bronze disc with EPDM seat insert, brass stem, and chatter preventing stainless steel spring. The valve design shall permit repacking under full system pressure. Each valve shall be equipped with brass readout valves (with integral check valve) to facilitate taking differential pressure readings across the orifice for accurate system balance. The valve manufacturer shall be ITT Bell and Gossett. HYDRAULIC TRIM On the suction side of the pump, install a wye strainer, and a ball valve for shut-off. The wye strainer and ball valve manufacturer shall be ITT Bell Gossett, Armstrong, Watts, Josam, or Owner approved equal. AIR SEPARATOR Horizontal tangential type air separator designed to effectively separate free air in hydronic cooling system. The air separator shall be heavy duty cast iron designed to function satisfactorily at working pressures up to 125 psi and liquid temperatures up to 350 F. The air separator shall have an integral weir designed to decelerate system flow to maximize air separation. The air separator shall be ASME stamped. The in-line air separator shall also assist in eliminating free air from the system by directing the air to an ancillary air vent attached to the air separator while reduced oxygenated water is circulated to the system. Manufacturer of the air separator shall be ITT Bell and Gossett. AIR VENT Non-modulating, high capacity, automatic type designed to purge free air from the system and provide positive shut-off at pressures up to 150 psig at a maximum temperature of 250 F. Vent shall be constructed of cast iron body and bonnet with stainless steel, brass, EPDM, and silicon rubber internal components. EXPANSION TANK Size tank to be suitable for the total water volume of the entire system using normal engineering standards and practices. Tank shall be either diaphragm or bladder design type. Tank shall be constructed of carbon steel shell with a heavy duty butyl rubber diaphragm. The air charging connection shall be to the diaphragm. Tank shall be suitable for outdoor installations. Tank shall be ASME stamped. Maximum operating pressure of the tank shall be 125 psi and the maximum operating temperature shall be 240 F. Acceptable Manufacturers of the expansion tank include ITT Bell & Gossett, Ventrite, or approved equal. CUSTOMER A S S U R A N C E www.rae-corp.com TECHNICAL S Y S T E M S DIVISION RAE CORPORATION P.O. Box 1206, Pryor, OK 74362 Phone 918-825-7222 Fax 800-COIL FAX T-18PP-202