EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

Similar documents
LISA Tallinna Vesi AS akrediteerimistunnistusele nr L065 ANNEX to the accreditation certificate No L065 of Tallinn Water Ltd

EESTI AKREDITEERIMISKESKUS

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

GUIDELINES FOR DESCRIBING THE ACCREDITATION SCOPES OF TESTING LABORATORIES

Team grup. Risk management during the production of mineral water. Presentation at the 3 rd SAFOODNET seminar. Urban Wiik.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

Understanding the Balance

CERTIFICATE OF ACCREDITATION

Nutrient Management And Nutrient Cycling Raymond C. Ward, President Ward Laboratories, Inc Kearney, NE

Soils and Fertilizers. Leo Espinoza Soils Specialist

EAK AKREDITEERITAVAD TAVAD VASTAVUSHINDAMISMENETLUSED EAK INF1 2016

INTERNATIONAL STANDARD

CEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.

Anorganic Fertilizer. Lenny Sri Nopriani, SP.MP

A STATE OF THE ART INTEGRATED CHEMICAL BIOLOGICAL & RADIATION WATER MONITORING SYSTEM

DENITRIFICATION EFFECT OF BACTERIA THIOBACILLUS DENITRIFICANS DENITRIFIKACE ČINNOSTÍ BAKTERIÍ THIOBACILLUS DENITRIFICANS

DISINFECTING 99.9% KILLS. 1.7 OZ (47 g) Wet Floor Cloth WET MOPPING CLOTHS. Tuscan Lavender & Jasmine KEEP OUT OF REACH OF CHILDREN CAUTION:

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

Soil. Acidic soils... 1/19/2014

Sunlight. Chlorophyll

Learning Objectives. C. Owen Plank

This document is a preview generated by EVS

This document is a preview generated by EVS

Fertilizers and nutrient management for hops. Diane Brown, Michigan State University Extension

This document is a preview generated by EVS

EESTI AKREDITEERIMISKESKUS

ULTRA-VIOLET STERILIZATION

How clean is your dishcloth?

This document is a preview generated by EVS

Specialist Cleaning System & Long Lasting Residual Disinfection Solution

This document is a preview generated by EVS

Developing and Implementing a Fertilizer Program. Marc van Iersel. mixed with substrate components before planting

This document is a preview generated by EVS

HPL and solid grade (Compact) through-colour laminate

This document is a preview generated by EVS

5. Drain excess liquid and allow to air dry. KEEP OUT OF REACH OF CHILDREN DANGER

STS Directory Accreditation number: STS 0021

Turfgrass Fertility. Soil Test Reports. Why Soil Sample? Interpretation & Understanding

Crop Management Practices. By Simon Bedasie

Greenhouse Plant Nutrition

Soils and Fertilizers Chapter 2. Sherry Kern Virginia Beach Master Gardener Tree Steward

DOMESTIC WATER RECORDS

Prof. Dr. Mieke Uyttendaele, Dr. Liesbeth Jacxsens, Imca Sampers Ghent University Faculty of Bioscience Engineering

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

This document is a preview generated by EVS

Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2000 to June 30, 2001

GEOL 408/508 INTRODUCTORY SOILS

LaMotte. Soil Test Kit Garden Guide.

Specification of Soils for Biotreatment or Bioretention Facilities

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

ATTACHMENT L. Provision C.3.c.i.(1)(b)(vi) Specification of soils for Biotreatment or Bioretention Facilities

10 Second Machine. 10 Seconds to Better Health Ozone Faucet Systems by Cashido Corporation

SteroklorPlus. Cleaner Sanitizer 3IN1Disinfectant KEEP OUT OF REACH OF CHILDREN DANGER. Mold & Mildew Killer and Stain Remover

Refrigeration air dryer

B. Land capability subclass - DELETED Determine Land Capability Subclass according to the following rules. Mark all subclasses that apply.

Instructions for Easygel Method

Understanding Soil Microbiology and Biochemistry

How your rose bush makes food

This document is a preview generated by EVS

PERFORMANCE EVALUATION OF DIFFERENT GREEN ROOF DESIGNS CHENGDU, CHINA

Effect of Storage Duration in the Quality of Vermicompost

Sampling protocol for crops (taken at harvest and at point of sale to consumer) for laboratory analysis by CARIRI

Soil Health and Fertilizer. Pam Brown, Extension Agent Emeritus, Gardening Coach

HPL and solid grade (Compact) through-colour laminate

A comparative study of different hand drying methods: paper towel, warm air dryer, jet air dryer.

This document is a preview generated by EVS

Monitoring Nutrition for Crops

Multiple-event study of bioretention for treatment of urban storm water runoff

Checklist for EASYZON Chlorine dioxide system

Unit D: ph of Soil. Lesson : Identifying the ph Changes in Soil

SANITIZER Applicable for SFS16, SFS17, SFS18, CP1617, CP1603, CP1605

Chi-hsu Hsieh*, and Allen P. Davis**,

This document is a preview generated by EVS

Vernier Adapter DATA HARVEST. ( Product No )

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Just Add Water. KEEP OUT OF REACH OF CHILDREN See Back Panel for Additional WARNING:Precautionary Statements

Terminology & Soil Science. Andy Spetch

Just Add Water. KEEP OUT OF REACH OF CHILDREN See Back Panel for Additional WARNING:Precautionary Statements

Know Your Soil Getting the Dirt on Your Dirt FWAA. Dr. Steve Petrie Director of Agronomic Services

GROW & GROWTH. Products BROCHURE. Keeping together is Progress Working together is Success EVERGROW FOR SPECIALITY FERTILIZERS

Komjatická 73, Nové Zámky. Principle / Type. ph potentiometric method ŠPP No. 001-D, ŠPP No. 001-F SL, ČL, Ph. Eur.

AC39 Manual Water Softener Operation and Recharging

Class 3: Soil Sampling and Testing. Chris Thoreau

AC40 & AC40BAutomatic Water Softener Operation and Recharging

This document is a preview generated by EVS

Cleaning & Sanitising Food processing industry. Replacing synthetic cleaners & sanitisers by natural alternatives

Ministerial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

SOILS. Sam Angima. OSU Extension Agent Lincoln County, Oregon

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

This document is a preview generated by EVS

This document is a preview generated by EVS

Transcription:

1/6 EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE LISA 9 OÜ Eesti Keskkonnauuringute Keskuse akrediteerimistunnistusele nr L008 ANNEX 9 to the accreditation certificate No. L008 of Estonian Environmental Research Centre LLC 1. Akrediteerimisulatus on: Accreditation scope is: Keskkonnaanalüüsid Environmental analyses Nr Määratavad näitajad 9.1 Ammooniumioon (NH4 + ) Ammonium ion 9.2 Nitritioon (NO3 - ) ja nitraatioon (NO2 - ) ning nende summa (pidevvooluanalüsaatoriga) Nitrite ion and nitrate ion and the sum of both by flow analysis 9.3 Üldlämmastik (Nüld) (oksüdeerimine peroksodisulfaadiga) Total nitrogen (Ntot) ( digestion with peroxodisulfate) 9.4 Sulfaatioon (SO4 2- ) Sulfate ion Fotomeetria Photometry Joogi-, põhja-, basseini-, pinna-, mere-, heitja reovesi waste Joogi-, põhja-, basseini-, pinna-, mere-, heitja reovesi waste Põhja-, pinna- ja merevesi Ground, surface and sea SFS 3032 0,01 mg/l EVS-EN ISO 13395 0,003 mg/l (NO2 - ) EVS-EN ISO 11905-1 AOAC973.57 0,04 mg/l (NO3 - ) 0,02 mg/l 0,5 mg/l

2/6 Nr Määratavad näitajad 9.5 Ortofosfaatioon (PO4 3- ) Ortophosphate ion 9.6 Üldfosfor (Püld) Total phosphorus (Ptot) 9.7 Üldraud (Fe) ja kahevalentne raud (Fe 2+ ) Total iron and iron (II) 9.8 Lahustunud silikaadid Dissolved silicate 9.9 Hägusus Turbidity 9.10 Klorofüll-a Chlorophyll-a 9.11 Hõljuvaine Suspended solids Põhja-, pinna-, mere-, heit- ja reovesi Joogi-, põhja-, pinna-, heit- ja reovesi Drinking, ground, surface and waste Joogi-, põhja-, basseini-, pinna- ja merevesi waste Pinna-ja merevesi Surface and sea Gravimeetria Gravimetric determination EVS-EN ISO 6878 Sec. 4 EVS-EN ISO 6878 Sec. 7 SFS 3028 STJnrV28 Methods of Sea Analysis, Grassoff,1999 EVS-EN ISO 7027 ISO 10260 EVS-EN 872 0,015 mg/l 0,005 mg/l 0,01 mg/l 0,01 mgsi/l 0,5 NHÜ 0,5 μg/l 9.12 Kuivjääk Joogi-, põhja-, pinna-, heit- ja reovesi SFS 3008 2 mg/l Dry residue Drinking, ground, surface and waste 9.13 Naftasaadused ja rasvad Põhja-, pinna-, heit- ja reovesi EPA Method 1664 2 mg/l Oil products and fats Ground, surface and waste Tiitrimeetria Titrimetric determination 9.14 Kaltsium (Ca 2+ ) Joogi-, põhja- ja pinna-, heit- ja reovesi ISO 6058 1 mg/l Calcium Drinking, ground, surface and waste 9.15 Üldkaredus Joogi-, põhja-, pinna-, heit- ja reovesi ISO 6059 0,1 mg-ekv/l 2 mg/l

3/6 Nr Määratavad näitajad Total hardness Drinking, ground, surface and waste 9.16 Leelisus Alkalinity 9.17 Kloriid (Cl - ) (Mohr i meetod) Chloride (Mohr method) 9.18 Keemiline (permanganaatne) hapnikutarve e. oksüdeeritavus (KHTMn) Chemical oxygen demand (CODMn) 9.19 Keemilise (dikromaatne) hapnikutarve (KHTCr) Chemical oxygen demand (CODCr) 9.20 Üldlämmastik (Nüld) (modifitseeritud Kjeldahl meetod) Total nitrogen (Ntot) ( modified Kjeldahl method) 9.21 Vaba kloor ja summaarne kloor Free chlorine and total chlorine Joogi-, põhja-, pinna-, heit- ja reovesi Põhja-, pinna-, joogi-, mere- ja basseinivesi Ground, surface, drinking, sea and pool Põhja-, pinna-, mere-, heit- ja reovesi Ground, surface, sea and waste Heit- ja reovesi Waste Pinna-, joogi- ja basseinivesi Surface, drinking and pool- EVS-EN ISO 9963-1 SM 4500-Cl D APHA 2005 SFS 3036 ISO 6060 SFS 5505 EVS-EN ISO 7393-1 0,04 mg-ekv/l 0,75 mg/l 1 mgo/l 30 mgo2/l 1 mg/l 0,05mg/l 9.22 Elektrijuhtivus Electrical conductivity Elektrokeemilised määramised Electrochemical determinations Joogi-, põhja-, basseini-, pinna-, mere-, heit- EVS-EN 27888 ja reovesi waste 1,0 µs/cm 9.23 ph ph Joogi-, põhja-, basseini-, pinna-, mere-, heitja reovesi ISO 10523 (1,0 13,0) ph ühikut

4/6 Nr Määratavad näitajad 9.24 Biokeemiline hapnikutarve (BHTn) Biochemical oxygen demand (BODn) 9.25 Fluoriidioon (F - ) Fluoride ion 9.26 Lõhnaläve ja maitseläve indeks Threshold odour number and threshold flavour number 9.27 Värvus Colour 9.28 Proovivõtt Sampling waste Põhja- ja pinna-, joogi-, merevesi EVS-EN 1899-2 Ground, surface, drinking and sea ISO 5815-2 Heit- ja reovesi EVS-EN 1899-1 Waste ISO 5815-1 ISO 10359-1 Füüsikalis-keemilised katsed Physical Chemical tests Joogivesi EVS-EN 1622 Drinking Põhja-, pinna-, joogi-, mere- ja basseinivesi Ground, surface, drinking, sea and pool Proovivõtt Sampling Vesi, reoveesetted, setted Water, sewage sludge, sediments EVS-EN ISO 7887 sec D 0,5 mgo2/l 3 mgo2/l 0,1 mg/l 5 (5 mg/l Pt) ISO 5667 (1;3;4;5;6; 9;10;11;12;13;15;19) STJnrP7 Elektrokeemilised määramised mõõtmised proovivõtul Electrochemical determinations- in-situ measurements 9.29 ph ph 9.30 Elektrijuhtivus Electrical conductivity 9.31 Lahustunud hapnik Dissolved oxygen Vesi Water Vesi Water Vesi Water ISO 10523 EVS - EN 27888 EVS-EN ISO 5814 (1,0 13,0) ph ühikut 1,5 µs/cm (0,1 20) mg/l

5/6 Mikrobioloogia Microbiology Nr. Määratavad näitajad 9.32 Escherichia coli ja coli-laadsed bakterid Escherichia coli and coliform bacteria 9.33 Enterokokid Enterococci Mikrobioloogilised katsed Microbiological examinations Joogi-, põhja-, basseini-, pinna-, mere- ja heitvesi Joogi-, põhja-, basseini-, pinna-, mere- ja heitvesi 9.34 Pseudomonas aeruginosa Joogi-, põhja-, basseini-, pinna-, mere- ja heitvesi 9.35 Kultiveeritavate mikroorganismide kolooniate arv Culturable microorganisms colony count Joogi-, põhja-, basseini-, pinna-, mere- ja heitvesi 9.36 Staphylococcus aureus Joogi-, põhja-, basseini-, pinna-, mere- ja heitvesi 9.37 Enterobacteriaceae 9.38 Mikroorganismide arv 30 0 C juures. Total Plate Count at 30 degrees C 9.39 β-glükuronidaas-positiivne Escherichia coli beta-glucuronidase-positive Escherichia coli 9.40 Salmonella spp 9.41 Coli-laadsed bakterid Coliform bacteria EVS-EN ISO 9308-1 EVS-EN ISO 7899-2 EVS-EN ISO 16266 EVS-EN ISO 6222 EVS-EN ISO 6888-1 EVS-EN ISO 6888-1 ISO 21528-2 EVS-EN ISO 4833-1 ISO 16649-2 ISO 6579 ISO 4832

6/6 Nr. Määratavad näitajad 9.42 Listeria monocytogenes 9.43 Listeria monocytogenes 9.44 Pärmid ja hallitused Yeasts and moulds EVS-EN ISO 11290-1 EVS-EN ISO 11290-2 EVS ISO 21527-2 2. Katsetamist teostav struktuuriüksus: Pärnu osakond Part of legal entity that provides testing: Pärnu Department Aadressid: Roheline 64, Pärnu Addresses: 3. Labor on akrediteeritud standardi EVS-EN ISO/IEC 17025:2006 nõuete suhtes Laboratory is accredited against the requirements of standard EVS-EN ISO/IEC 17025:2006 Märkus: käesolev lisa asendab 06.07.2016 välja antud lisa seoses akrediteerimisulatuse kitsendamisega. Note: this annex replaces annex issued on 06.07.2016 due to reduction in the accreditation scope. Kristiina Saarniit Maia Valm EAK juhataja Peaassessor Director of EAK Lead Assessor Tallinnas, 16.06.2017