"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

Similar documents
"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

WHHR Midi & Midi Lite

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

G Installation manual Solitude - dmev unit

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Installation manual Mori HR

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra SELV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

CENTRIFUGAL FANS user's manual. model VENTS VK.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

User and maintenance manual

USER S MANUAL. VKP Series INLINE FAN

Lo-Carbon Quadra Centrifugal Fan

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

HEAT RECOVERY VENTILATOR

AXIAL FANS USER S MANUAL

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Silhouette Installation and Wiring Instructions

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Local air conditioner

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Calm. Service Instructions

Instructions for use

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Installation & Operating Instructions

Xcell 270 Longlife DC wholehouse heat recovery unit

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

INTELLIGENT AXIAL FAN user's manual

Turbo. Service Instructions

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

Lo-Carbon SELV Tempra

Aero. Service Instructions

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Wind. Service instruction

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

Installation and Wiring Instructions

Mobile Air Conditioner Instruction Manual Model TC-N9KM

HOTLINE:

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

OWNERS INSTRUCTION MANUAL

ISCG90SS _03 ISCG90SS

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Box60/ 70/ 90. Box60_70_90 v8

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Drying Cabinet Installation and Operating Manual

GB User and maintenance manual

Instructions for use

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Instruction Manual JLCHDD601/JLCHDD901 60cm/90cm Cooker hood

USER'S MANUAL PGE Single Package Rooftop

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

HR200WK Through the wall Heat Recovery Ventilator

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Fig.2. Fig.3. Fig.4 L N L N

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

Simply Silent Contour 4 (100mm) Axial Extraction Fan

CENTRIFUGAL CEILING EXTRACT FAN

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9

Purge Ventilation Unit. Product Manual. ventilation systems TP625

INSTALLATION INSTRUCTIONS USER GUIDE

CENTRIFUGAL CEILING EXTRACT FAN

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Axial intelligent fan USER S MANUAL

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Heated Display Cabinet Installation & Operating Instructions

Whole Room Dryer WRD, WRD/110

Transcription:

"Microbox" Continuous Mechanical Extract Ventilation Units Installation, Operating and Maintenance Instructions 5 models rectangular and/or round spigots domestic and commercial use

Page 2 "MICROBOX" - CONTINUOUS MECHANICAL EXTRACT UNITS INSTALLATION AND OPERATING INSTRUCTIONS PLEASE READ THE FOLLOWING INSTRUCTIONS VERY CAREFULLY BEFORE USING THE PRODUCT. THE MANUFACTURER WILL NOT BE HELD RESPONSIBLE AND DECLINES ANY AND ALL LIABILITY FOR DAMAGE CAUSED TO PERSONS OR PROPERTY DUE TO IMPROPER USE WITH REFERENCE TO THE PRECAUTIONS OUTLINED IN THIS MANUAL. THIS MANUAL MUST ALWAYS BE READILY AVAILABLE. THE RANGE MBOX204/2: MBOX100/2: MBOX125/2: MBOX125/2Plus: MBOX150/2: 204mm x 60mm spigot, for dwellings up to 66m 2, max capacity 191m 3 /hr 4"/100mm spigot, for dwellings up to 66m 2, max capacity 172m 3 /hr 5"/120mm spigot, for dwellings up to 66m 2, max capacity 208m 3 /hr 5"/120mm spigot, for dwellings up to 100m 2, max capacity 310m 3 /hr 6"/150mm spigot, for dwellings up to 140m 2, max capacity 420m 3 /hr ATTENTION : This symbol indicates that care must be taken in installing this product in order to avoid (potentially lethal) injury both to installer and user. This instruction MUST be followed for installation. 1. Do not use this product for any purpose other than that for which it was designed and as shown in this leaflet. 2. Remove all packaging and check that your fan has not been damaged in transit. If in doubt, con tact your supplier. 3. Do not leave packaging within the reach of children or unskilled people. Dispose of hazardous waste (polystyrene, plastic, polypropylene, etc.) responsibly. 4. If the product is dropped or badly knocked, contact your supplier, dealer or manufacturer to ensure that it is operating properly. 5. Using any electrical equipment requires compliance with basic safety rules: - the product must not come into contact with liquid of any sort - the product must not be operated by children or other unskilled people. 6. The product should only be connected to the mains electricity supply or electrical outlet if: - your electrical voltage and frequency correspond to those shown on the rating label. - the capacity of your electricity supply is sufficiently powerful to operate the product at its maximum power. If this is not the case, contact professionally qualified personnel. 7. Before carrying out any maintenance or cleaning operation, the product must be switched off and disconnected from the main power supply.. 8. If a fault, malfunction or anomaly of any type occurs, the product should be made inoperative (by turning off the switch and by disconnecting it from the mains electricity supply) and qualified personnel contacted immediately. Always request original spare parts to carry out any repairs. 9. If the product needs to be removed, turn off the main network circuit-breaker and then disconnect the appliance from that network. 10. The unit should be installed in a safe location as far away as possible from children and/or unskilled people. 11. The electricity system to which the product is connected must comply with the current standards. WARNING : This symbol indicates that care must be taken to avoid damaging your product when following these instructions 1. This product is professionally manufactured and complies with the current standards regarding electrical equipment 2. This product conforms with the EEC directive EMC 89/336 concerning the suppression of radio interference and electromagnetic compatibility.

Page 3 3. This product must not be used in an ambient temperature greater than 40 C (104 F). 4. Do not leave the product exposed to the weather (rain, sun, snow, etc.). 5. Possible product applications are indicated in this leaflet. 6. Do not place the unit or any part of it in water or liquids, except as indicated in the cleaning and maintenance section. 7. When cleaning or performing routine maintenance, check the condition of the appliance. 8. To avoid the risk of fire, do not use the product in the presence of inflammable substances or vapours such as alcohol, insecticides, gasoline, etc. 9. The air or fumes being extracted must be clean and free from greasy particles, soot, chemicals and corrosive agents, inflammable or explosive mixes (if these substances are treated, conctact an authorised dealer for information on a specific range of explosion-proof products). 10. The device must be installed by professionally qualified personnel. 11. The product must be connected to the electricity supply by means of a double-pole switch with a minimum contact opening distance greater than 3 mm. 12. To ensure optimum operation, do not block the air intake and exit vents. 13. The room where the device is located must be adequately ventilated to ensure correct operation (UNI CIG 7129). 14. If the fan is sited in a room containing a fuel burning appliance, the installer must ensure that air replacement is adequate both for the fan and the fuel burning appliance. 15. The unit should not be used as an activator for water heaters, stoves, etc. 16. Any ducting used must be free from blockages 17. Your fan must not be exhausted into a duct which is already used for any other purpose (see Approved Document F1 2006 for guidance) 18. THIS APPLIANCE IS PROVIDED WITH THERMAL OVERLOAD PROTECTION. IF THIS IS ACTI- VATED, THE FAN MUST BE DISCONNECTED FROM THE MAINS ELECTRICITY SUPPLY. THIS WILL ALLOW THE OVERLOAD DEVICE TO RE-SET. AFTER A BRIEF PERIOD, THE FAN CAN BE RE-STARTED. IF THE FAULT PERSISTS, CONSULT VECTAIRE FOR FURTHER ADVICE. OPERATION 1. The Microbox is suitable for ceiling or wall installation (Fig. A) 2. If one of the spigots is not connected to ducting a safety grille MUST be fitted to that spigot, so that it is impossible for any moving part to be touched. 3. These fans run continuously at a preset trickle speed and have an independently switched boost speed. There is a choice of four trickle speeds, selectable during the installation by adjusting the dial on the top of the casing (Fig 9B). 4. The boost speed can be triggered by: - PIR (passive infra red) - DRH (dynamic remote humidistat) - AQS (remote air quality sensor) - THM (thermostat) - remote switch (which can be a light switch) 5. All the fans have an integral, over-run timer which is adjustable on installation from 0 to 25 minutes (Fig 9A). This controls the length of time that the fan will continue to operate at its boost speed once this has been triggered, and after: - if using a PIR, there ceases to be anyone within the scope of the PIR - if using a DRH, after the relative humidity has dropped to the pre-set level of the humidistat - if using an AQS, when the air quality has returned to an acceptable level - if using a THM, when the temperature has dropped to an acceptable level - if using a remote switch, when it is switched off.

Page 4 CLEANING AND MAINTENANCE 1. Before carrying out any maintenance or cleaning operations the mains electrical supply MUST be disconnected. 2. CLEANING AND MAINTENANCE SHOULD BE CARRIED OUT BY A QUALIFIED PERSON 3. Disconnect the terminal block (Fig. 11) before attempting to remove the motor impeller assembly. 4. Loosen the screws (Fig.12) without taking them off. 5. Rotate slightly and remove the motor-impeller assembly (Fig. 13). 6. Clean the motor-impeller assembly either with a dry brush or a dry cloth. 7. Electrical parts cannot be cleaned. 8. Reassembly in the reverse order to above. TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE HOW TO SOLVE THE PROBLEM The product is not working No power check to see that the electrical connection has been properly made and that there is an electricity supply coming to the fan. The fan blade is not turning Blade obstructed check to see there is nothing blocking it DIMENSIONS Model A(mm) B(mm) C(mm) ød(mm) E(mm) F(mm) Weight Kg MBOX 204/2 384 448 241 204x60 122 134 5.8 MBOX 100/2 384 448 241 96 122 134 5.8 MBOX 125/2 384 448 241 120 122 134 5.8 MBOX125/2Plus 436 510 307 125 167 183.5 7.0 MBOX150/2 436 510 307 150 187 201.5 7.5 INSTALLATION

Page 5 1 2 3 4 5 6 7 9 8 11

Page 6 12 13 WIRING DIAGRAMS MBOX/18/05/10 Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH Tel: +44 (0)1494 522333. Fax: +44 (0)1494 522337. Email: sales@vectaire.co.uk