Installation And commissioning manual. Series S Double Beam 1/16

Similar documents
SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

DUAL OPTIC. Installation manual

English. Series. Installation and Use Manual

CONFIGURATION OF THE OPTICALS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INDEX. Installation recommendation

INDICE. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INDEX. Installation recommendation

INDEX. Installation recommendation

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

PARVIS Safe and tranquil thanks to Parvis

FSLIMPRO

Perimeter protection

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Long-Range Barrier Sensors

Active Infrared Multi Beam Sensors

Active Infrared Multi Beam Sensors. R Series

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

D-Tect 2 GJD300 Quad PIR Movement Detector

ACTIVE INFRARED BARRIER

Safety Light Curtains Area Access Control

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

INFRARED MODULATED BARRIERS

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Description. Optex Incorporated

BARRIERE & SENSORI BARRIERS & SENSORS

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Twin Photobeam Detectors Manual

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

BARRIERS & SENSORS Catalogue 2017

D-TECT Dual Tech. GJD360 Triple Technology External Detector

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

CAUTIONS ON INSTALLATION

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Safety Photo Beam UL MONITORED DEVICE

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

Quadruple-beam photoelectric detector

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Intrusion Outdoor Protection Perimeter

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Table of Contents. Intrusion Detectors... I-1. Intrusion Panels... II-1. Type Index... III-1

Photoelectric Beam Detector

Optical Beam Smoke Detector RK90R - RK90RS

SAFETY DEVICE 3 WITH VISIBLE LASER EMISSION MSD

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

2 General Application Photoelectric Sensors

Intrusion. Outdoor protection perimeter

/ / 2018

LiteFENCE Lite with SV Lite Sensor

4 Channel Contact Closure SFP DIN Fiber Link System

Movement Detector GJD 300

2 General Application Photoelectric Sensors

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Snifter ATEX22 VERSION. User Manual. Distributor

WM3000 WIRELESS MODULES

"Pegaso" wireless alarm system

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

2 General Application Photoelectric Sensors

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

English. Italiano. Português. Françias. Español

Automatic Self-Adjusting General Purpose Sensor

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

SECURITY SENSORS PHOTOELECTRIC BEAMS PASSIVE INFRARED SENSORS FLAME SENSORS GLASS BREAK SENSORS DOOR SENSORS ATTENTION SENSORS

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

2 General Application Photoelectric Sensors

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

DI601AM Outdoor PIR/AM Detector Installation Sheet

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

D-TECT 2 IP. GJD230 IP Motion Detector

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Solar Powered Wireless Photobeam Sensors

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

PHOTOELECTRIC DETECTOR

HX-80NRAM. High Mount Outdoor Detector

Laser Distance Sensor Type M Analog-Output

Motion Detectors. Whatever the application, there s a Paradox motion detector that will suit your needs and surpass your expectations.

Guardall BG-9 BG-9. High Security Seismic Detector

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

Transcription:

Installation And commissioning manual Series S Double Beam 1/16

2/16

Index Main components list Pag. 4 Installation reccomendations Pag. 5 Mounting the bracket Pag. 6 Installation example Pag. 7 Positioning the beam with respect to others in the perimetr Pag. 8 Cabling and terminal connections Pag. 9 Transmitters main P.C.B. Pag. 9 Receivers main P.C.B. Pag. 10 Alignment Pag. 11 Vertical alignment of the mirror Pag. 11 Horizontal alignment of the mirror Pag. 11 Set-up using the test points Pag. 12 Setting and programming Pag. 14 Operational characteristics and link setting Pag. 14 Technical specifications Pag. 15 3/16

Main component list N Parte Q.ty Description 1 1 Mounting plate 2 1 Front cover 3 2 4 2 Front cover top/end caps Trasmitter / receiver optic 5 1 Flat cable 4/16 6 1 Receiver / trasmitter Main P.C.B. 7 4 Bracket

Installation reccomendations Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the end of the installation. Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the cable glands supplied. Avoid any type of obstruction between the transmitter and receiver. Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers beams, can enter directly into optics especially at sunset and sunrise Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is always better place either transmitter or receivers back to back. Do not use switched power supplies which can induce noise on the power supply voltage which can in turn be amplified by the optical sync electronics creating unwanted problems. 5/16

Mounting the bracket Insert the bracket back to mounting plate Pole mounting Diameter 50 mm Wall mounting 6/16

Installation example Pole mounting Wall mounting Wall mounting With interposed brakets 7/16

Positioning beam with respect to others in the perimeter Tx Rx Rx Tx 8/16

Cabling and terminal connections TRANSMITTERS MAIN P.C.B. 9/16

RECEIVERS MAIN P.C.B. 10/16

Alignment Initial alignment Once beam columns have been correctly installed point the transmitter optics towards its corresponding receiver and vice versa, repeat for all the beam pairs. This is achieved by manually positioning the lens holder horizontally and vertically using one of the two screws (which ever is more convenient) to be found above the lens. Horizontal alignment Vertical alignment 11/16

Set-up using the test point It is necessary to put the transmitter PBC A into the test mode in order to complete the alignment. Phase 1 Phase 2 Phase 3 Phase 4 Phase 5 Insert into ON position the TEST P SET Link on the main transmitter PCB Move in OFF the dip switch corresponding to the beam to be aligned. Connect the Voltmeter, using the cable supplied, to the corresponding receiver test point, move the transmitter optics slightly in both axes (horizontal and vertical) until the maximum voltage is obtained. Repeat with receiver optics. Once the alignement is obtained replace the dip switch in ON Repeat the above procedure for all beam pairs after which reinsert, into OFF position the TEST P SET Link Transmitters Phase 1 and 4 12/16

Phase 3 Verifing on the tester at the Test Point RX Use the cable supplied Reading without Signal 0,20V 0,40V Reading with signal From 3 to 4V From 6 to 7V Receivers In alignement always obtain the maximum value 13/16

Setting and programming OPERATIONAL CHARACTERISTICS AND LINK SETTING AND In the ON position at least two beams must be interrupted in order than an alarm condition is created. This feature can also be enabled remotely via the appropriate command on terminal block (AND with + 12 V dc) N.A. N.C. The Link chance the relay output from normally Open (NO) to normally Close (NC). TAMPER Connector for tamper switch. LED ALM Alarm confirmation LED. Normally OFF indicates and alarm when lit. 14/16

Technical specifications MODELS DUAL QUAD ESA Maximum range 850 m Max useable range internal 240 m Max useable range external 80 m Minimum range 4 m 8 m Tower height 35 cm 1 m 1,5 m 2,0 m Synchronization Optical Total number of beams 4 crossed 16 crossed 36 crossed Power requirements 12Vdc Power consumption for tower Tx / Rx 40 ma Tx / Rx 60 ma Tx / Rx 80 ma heater 12W 24Vac 20W 24Vac termostatically controlled 30W 24Vac termostatically controlled OPERATING TEMPERATURE 25 / +65 (Available KIT heaters for lower temperature operation up to -50 ) VERTICAL ALIGNMENT ANGLE 20 HORIZONTAL ALIGNMENT ANGLE 180 AND/OR DETECTION OPTION REMOTE AND CONTROL AUTOMATIC ANTI-BLANKING SYSTEM (SHUTNTABLE) ADJUSTABLE DETECTION SPEED 50/500 ms ALARM OUTPUT RELAY NO/NC SELECTABLE NC TAMPER OUTPUT SHUNTABLE LED S INDICATING: ON-BLANKED-ALARM-HEATING PULSED INFRA-RED SIGNAL WAVELENGHT 950 mm PROTECTION RATING IP 54 WALL MOUNTING POLE MOUNT ADAPTER 2 YEAR GUARANTEE 15/16

POLITEC s.r.l. POLITEC s.r.l. Via Adda 66/68 20882 Bellusco (MB) Italy Tel. + 39.(0)39.6883019 r.a. fax + 39.(0)39.6200471 www.politecsrl.it 16/16 R 2.0