User Manual X8s Access Control System

Similar documents
Installation Guide & User Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

DOLKPL1KB DOLKPS1KB DOLKSF1KB

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

SCR100 User Manual. Version:1.1 Date:Dec 2009

DOLKPS1KB Programming & Installation Manual

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

GSM RFID VOICE Alarm System

D3D Wi-Fi GSM Smart Alarm System -User Manual

RFID Card Access Control Unit. Operating Instructions

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Addendum for STI-6406 with Dual Access Control

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Exit Stopper. STI-6400 Series

1. Introduction. 2. Product overview

SF100 User Manual Version 1.0

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

MOBILE CALL GSM Alarm System User s Manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Touchpad Exit Controller Administration Guide

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Exit Stopper. STI-6400 Series

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Contents. Contents

Operating instructions 2-channel code lock. Item No

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

status AW1 Plus WiFi Alarm System User Manual

Intelligent Wireless GSM Alarm System

Security GSM Alarm System

Security System. User Guide for the LED Command Center

PROGRAMMING PROCEDURES (Table 3)

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

User Manual Keep this manual safe for future reference

User Manual (LS-GSM-006)

User Manual YDR2108. Keep this manual safe for future reference

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

User Manual YDM The functions and design of this product can be changed without notice for quality improvement. Chinese manual is from 33 page.

Wireless Keypads LKP(E)S8M Series

Operating Instructions Transponder code lock - Part 2 (split decoder)

Installation Instructions

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM WS-500X CONTENTS REV: 0.2 ERP P/N: ERP 机型 :SS21W2R-AU-EDP09940A-V1

SPLIT-DECODED CONTROLLER

WIRING DIAGRAM AND INSTRUCTIONS

IM20-ZWAVE Magnetic Contact User Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

S3 Sim Secual Alarm system with GSM transmitter

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Integration Test Plan

IQ PANEL USER GUIDE SMARTHOME.

G34 AU1B (External Ultrasonic Sensor) Version 3

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

General Purpose IO Technical Manual

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Fingerprint door lock S210. Zhejiang SFG Technology Co., Ltd.

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Shed Alarm Kit. User Manual

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

EasyLoader. End User Manual

Ethernet General Purpose

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

C2 Compact Range Installation & Programming Manual

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Wireless Alarm system s manual

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

EM8710 GSM Alarm System Starter Kit

Sentry 4 Zone Alarm Panel User Manual

External Wireless Sounder

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

U-Prox IP550. Wireless access control panel. Instruction manual. W i r e l e s s a c c e s s c o n t r o l p a n e l w i t h b u i l t i n r e a d e r

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

EVO192 v3.0 Fire and Burglary What s New

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

Wireless Keypad GKP-S8M

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

2000 Series. Program Entry Guide. Control Panels

PERMACONN PM1030 Includes DI300. Installation Manual

JA-63 Profi User manual

InBio X60 Series Access Control Panel User Manual

Contents. Glossary

TPMS USER MANUAL. Table of Contents. Impaqed Products BV.

Transcription:

User Manual X8s Access Control System Version: 1.0

I 1. Equipment Installation (1) Remove the screw from the bottom of the device. (2) Remove the back cover of the device. (3) Fix the back cover on the wall. (Drill the wiring hole and fixing holes according to the back cover) (4) Fix the device on the back cover using screws. Tamper Alarm Button 2. Structure and Function Lock Door Sensor Exit Button Bell Alarm Access Control System Function: (1) When a registered user's identity is verified, the Access Control device will send out signal to unlock the door. (2) The door sensor will detect the status of the lock. If the door is unexpectedly opened or improperly closed, an alarm will be triggered. (3) It supports the exit button for opening the door from inside. (4) It supports door bell. (5) If the Access Control device is dismantled, the alarm will be triggered.

II 3. Lock Connection Warning: No operation when power on! (1) The system supports NO LOCK and NC LOCK. The NO LOCK (normally open at power ON) is connected with NO terminal, and the NC LOCK is connected with NC terminal. (2) To prevent the generation of selfinductance EMF which would affect the system, when the electrical lock is linked to the Access Control System, it is required to connect one FR107 diode (equipped in the package, do not reverse the polarities) in parallel in order to release the selfinductance EMF. (1) Device shares power with the lock (2) Does not share power with the lock The device shares power with the lock, when U LOCK=12V and II LOCK >1A and the lock is near to the device. DC12V NC Lock 12V BUT SEN NO1 COM1 NC1 AL BELL I: device current output, U LOCK: lock voltage, I LOCK: lock current. DC12V DC12V (3) Professional Access Control Power Supply Connection The device does not share power with the lock: A. When U LOCK =12V II LOCK 1A; B. When U LOCK 12V; C. When the lock is far apart from the device. NC Lock 12V BUT SEN NO1 COM1 NC1 AL BELL 12V 12V AL BELL AL BELL BUT NC NO SEN PUSH NO1 Exit Button COM1 NC Lock NC1 Professional Access Control Power Supply AL AL BELL BELL Access Control Device

III 4. Connection with Other Devices Only devices with an alarm consuming <=12V DC can be connected. 5. Connection with Power Input 12V DC, 500mA (50mA in idle status). Positive is connected with 12V, negative is connected with (do not reverse the polarities).

1 Instructions Step 1: Power ON after the device is completely installed on the wall. Step 2: Authenticate administrator password and change it immediately. Adjust access control parameters including password change for door opening, setting unlocking duration, authentication mode, concealed mode, door sensor mode, etc. Step 3: You can register and authenticate user accounts, cards or passwords. Operation Instructions 1. User Management 1.1 Administrator Operation To ensure data security of the device, users can operate the device only after the administrator password Administrator Authentication 1. Press [*] (The indicator is off and makes a long beep.) 2. Press[#]. (Enter step of password authentication.) 3. Enter the administrator password. (The default password is 1234.) 5. Exit. (Press [*] or do not operate the device within 20 seconds, The indicator turns red and makes a long beep, then automatically exit.) 4. Authentication succeeds..) Note: The default administrator password is 1234. You are advised to change the initial password at the beginning. Changing Administrator Password 1. The administrator password 2. Press [8]. 3. Enter a new administrator password. Fail (The indicator turns red and makes three beeps.) Succeed 6. Exit. (The indicator turns red 5. Password is successfully changed. (The indicator turns green 4. Enter the new administrator password again for authentication. Note: Fourdigit passwords are automatically verified. If the password length is less than four digits, then press [#] to confirm the password.

2 Opening Door by Entering Administrator Password 2. Press [0] or [#]. 3. Press [0] or [#]. and 5.Exit. 4. The door is opened and Note: This function can be used to open the door. Forgot Administrator Password If the administrator password is lost, you can reset the password to default by using tamper switch. Operation: 1. Dismantle the device and wait for 30 seconds until a short beep is heard. 2. Press the Tamper Switch thrice to reset to the initial administrator password. Note: This operation must be done within 30 seconds; the default administrator password is 1234. 1.2 Adding Users Register the fingerprint or card of a user or register cards in batches. Adding a User 1. The administrator is authenticated. 2. Press [1]. 4. Register fingerprint or card. (Press fingers three times or swipe the card once.) 3. Input user ID twice (The indicator turns green and makes a long beep.) 4. Register fingerprint or card. (Press fingers three times or swipe the card once.) 6. Exit. (Press [*], the indicator turns red and makes a long beep. ) 5. Registration succeeds. Note: 1. Fivedigit user ID is automatically verified, if the user ID is less than five digits, press [#] to confirm the user ID. 2. If the user ID is not available, the device automatically increases the ID number and

3 continues to register a new user once the user is successfully registered. 3. If the user ID, fingerprint or the card has been registered already, the indicator turns red and generates three short beeps indicating that the registration fails. You can start registering the user again when the indicator turns green. Note: If you fail to register the card, then press fingerprint or enter user ID thrice to set the device in idle state. Registering Cards in Batches 2. Press [6]. (Register cards in batches) 3. Swipe the first card once. 6. Exit. makes a long beep, then automatically exit.) 5. Cards are successfully registered in batches. Fail (The indicator turns red and makes three beeps.) Succeed 4. Enter the total number of cards. Note: 1. While registering the card number, threedigit card numbers are automatically verified. For card number less than or greater than three digits, press [#] to confirm and then press [*] to register the card number. 2. You must clear all the registered users before registering the cards in batches. IDs of the toberegistered cards must be in consecutive numbers. 1.3 Registering Access Passwords This device supports 8 passwords, each password has a Group ID ranged from 1 ~ 8. The default password value is 0 for all groups, which means those passwords are disabled. 2. Press [3]. (The indicator turns green and makes a long beep.) 3. Enter the group ID of password.(group IDs: 1 ~ 8.) 7. Exit. (Press [*], the indicator turns red and makes a long beep, then automatically exit) 6. Registration succeeds. 4. Enter the password twice. (The password is consists of four digits.)

4 Note: 1. When a password is changed to 0, 00, 000, or 0000, the password is disabled. 2. When a password is successfully changed, you can immediately change the next password by entering another group ID. 1.4 User Authentication Card / Fingerprint / Password Authentication When the device is powered ON, it enters user authentication state. 1. The device is in user authentication state. 2. Swipe user card, or enter password followed by "#". Succeed 3. User authentication succeeds. (The indicator turns green and makes a long beep.) Fail (The indicator turns red and makes two beeps.) Note: Press [#] after entering the password for authentication. The door opens only if the entered password matches with one of the 8 passwords. The initial eight passwords for opening the door is set to 0. 1.5 User Deletion Delete one, multiple or all registered user(s). Deleting One User is authenticated. 2. Press [2]. 3. Enter a user ID, press the fingerprint, or swipe the card. Fail (The indicator turns red and makes three beeps.) Succeed 6. Exit. (Press [*] or do not operate the device within 20 seconds, the indicator turns red and makes a long beep.) 5. User deletion succeeds. 4. Determine whether the user is authentic. (The indicator turns green and makes a long beep.) Note: 1. You can either swipe the card, press fingerprint or input user ID to delete a user.

5 Fivedigit user ID will be automatically verified. If user ID is less than five digits, press [#] to confirm. 2. After successful deletion, the device will automatically enter the process of deleting next user. Press [*] to exit. Deleting All Users 2. Press [9]. 3. Press [9]. and 5.Exit. makes a long beep, then automatically exit.) 4. Deletion of all users succeeds. and Note: In step 3, press [9] for automatic confirmation. Other numbers are considered invalid. If an invalid number is entered, the device indicator turns red and makes three short beeps, then makes a long beep and exits the process. 2. Access Control Management 2.1 Unlocking Duration Configuration 2. Press [4]. 3. Enter the unlocking duration. (range: 1s to 10s) 5.Exit. makes a long beep again.) 4. Modification of the unlocking duration succeeds. and Note: Press [10] for automatic confirmation. For values with less than 10, press [#] to confirm. Values greater than 10 will be considered invalid.

6 2.2 Authentication Mode Configuration 2. Press [5]. 3. Enter authentication mode. 5.Exit. 4. Configuration succeeds. and Note: Details of authentication modes are as follows: Authentication Mode Value Description PW 1 Only password verification RF 2 Only RF Card verification FP 3 Only fingerprint verification FP/PW/RF 4 fingerprint or password or RF Card verification RF&PW 5 FP&PW 6 RF Card and password verification (swipe card before entering password) fingerprint and password verification (fingerprinting before entering password) 2.3 Concealed Mode Configuration In standby mode, when the Concealed Mode is ON, the indicator will be turned OFF. 2. Press [0]. 3.Press [3]. and 6.Exit. 5. Configuration succeeds. 4.Configure the concealed mode (0: enable; 1: disable). Note: When user is authenticating the card or fingerprints or password in Concealed Mode, the indicator will still blink correspondingly to denote process status.

7 2.4 Door Sensor Mode Configuration The door sensor has three modes: NONE: The door sensor is disabled. NO (Normally Open): The door sensor will send an alarm signal if it detects the door is closed. NC (Normally Closed): The door sensor will send an alarm signal if it detects the door is open. 2. Press [0]. 3.Press [5]. and 6.Exit. makes a long beep again) 5. Conflagration succeeds. 4.Configure the door sensor mode (0: NO;1: NC; 2: None). 2.5 Alarm Configuration Note: If an alarm is triggered, it will be terminated only after the user Configuring Alarm Switch Failed Authentication Alarm and Door Sensor Alarm will be effective only if the alarm switch is set to ON status. Note: The default status of the alarm switch is ON. 2. Press [0]. 3.Press [1]. and 6.Exit. makes a long beep again.) 5. The configuration is successful. 4.Configure the alarm setting. (0: enable; 1: disable). Note: The Tamper Alarm will be effective even if the alarm switch is set to OFF. Configuring Failed Authentication Alarm If the administrator fails in authentication in 3 attempts, Failed Authentication Alarm will be triggered. No authentication can be made within 20 seconds.

8 2. Press [0]. 3. Press [2]. and 6.Exit. makes a long beep again.) 5. Configuration succeeds.. Failed Authentication Alarm Switch. (0: enable; 1: disable). Configuring Tamper Alarm If this function is enabled, alarms will be raised when the device is dismantled from the wall. 2. Press [7]. 3. Configure Tamper Alarm Switch. (0: enable; 1: disable). 5. Exit. 4. Configuration succeeds. and Configuring Door Sensor Delay When the door is not closed well after the set time period, the Door Sensor Alarm will generate an alarm signal to alert the users. 2. Press [0]. 3.Press [4]. and 6.Exit. 5. Configuration succeeds. 4.Configure the Door Sensor Delay. (range: 1s to 254s). Note: 1. Threedigit values will be automatically verified. For values with less than three digits, press [#] to confirm. Values greater than 254 are considered invalid. 2. When an alarm is triggered, the device interior alarm will be triggered first. After 30 seconds, the device exterior alarm will be triggered.