Manual No: Revision: C. Overfill Alarm. Installation Guide

Similar documents
Manual No: Revision: D. Sump Sensor. Installation Guide

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Manual No: Revision: G. Sensor Products. Application Guide

Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM #

Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps

Manual No: Revision: J. Groundwater Sensor. Installation Guide

Interstitial Liquid Sensor - Fiberglass Tanks

Installation Instructions Manual No: Revision F

Manual No: Revision: H. MicroSensor. Installation Guide

2 To 1 Sensor Input Box

Installation, Operation & Service Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Installation Instructions. Remanufactured Veeder-Root Position Sensitive Sump Sensor. PMP # Replaces Veeder-Root #

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors

Radiant Thermostat 519

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

3820, 3820i, 4820, 4820i

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

SAFETY INFORMATION AND WARNINGS

INSTALLATION ADJUSTMENT SERVICE

Model GIT 4 Gutter Snow and Ice Melting Control

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

CVS Model Inline Multi-Port Ventilators

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

ISIMET Series Shop Controller

Installation and Operation Manual

SeedVac TM REF 90091

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Instruction Manual. Bucket Oil Pump

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

20 High velocity Air

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Heliport Perimeter Light Type MIJ

Multiple Boilers Electro TS Series Application EB-C-STG5

Computer Room Guard Model VM Manual and Installation Instructions

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Static Pressure Alarm For Hazardous Location Fume Hoods

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Advanced Test Equipment Rentals ATEC (2832) Installation Note

Environmental Monitoring SmartSlot Card

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

A10. Installation & Operation Manual. Flow Switch. For the latest version of this manual, visit kteksolidslevel.com.

Patent Pending invent for New Construction

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

Figure 1. Figure 2. See notes 1 and 2 below.

CT2 Retro Box Installation Instruction Manual

PAT LOAD MOMENT INDICATOR DS 150 / 0038

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

Owner s Manual & Safety Instructions

INSTALLER S & OWNER S MANUAL

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

ion Genesis Pump Controller

Environmental Monitoring Card

AeroVent 1 Product Manual

MaxLite LED High Bay Fixtures

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Inline Heater for Solvent or Gas. Installation and Operation Manual

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

MicrOTDR. Optical Fault Locator. User Manual

AeroVent 3X Product Manual

Instruction Manual. Nacho Cheese Dispenser and Warmer

GENERATION 2 QUADRATHERM Heater

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

ELECTRONIC BELL (A80301)

Model 405 AIRGARD Fume Hood Monitor

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

MN908 No. 282C Replaces 282B LB7013

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Wax Base Heater & Dispenser

Interrupted Ignition Series Oil Primary Control

Transcription:

Manual No: 576013-589 Revision: C Overfill Alarm Installation Guide

Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication. Veeder-Root reserves the right to change system options or features, or the information contained in this publication. This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root. For complete warranty, technical support, and additional product information, refer to your console s Operator Manual. DAMAGE CLAIMS 1. Thoroughly examine all components and units as soon as they are received. If damaged, write a complete and detailed description of the damage on the face of the freight bill. The carrier's agent must verify the inspection and sign the description. 2. Immediately notify the delivering carrier of damage or loss. This notification may be given either in person or by telephone. Written confirmation must be mailed within 48 hours. Railroads and motor carriers are reluctant to make adjustments for damaged merchandise unless inspected and reported promptly. 3. Risk of loss, or damage to merchandise remains with the buyer. It is the buyer's responsibility to file a claim with the carrier involved. Immediately advise your Veeder-Root representative, distributor, or the factory so that we may assist you. RETURN SHIPPING For the parts return procedure, please follow the instruction in the Veeder-Root Warranty and Dispatch Program pages in the Policies, Literature, and Contact Section of the Veeder-Root Consoles - North America Price List. Veeder-Root 2002. All rights reserved.

Table of Contents Introduction Compatible Consoles...1 Related Manuals...1 Contractor Certification Requirements...1 Safety Symbols...2 Safety Warnings...2 Mounting Instructions Overfill Alarm and Acknowledgement Switch Dimensions...3 Mounting Instructions...4 Overfill Alarm...4 Acknowledgement Switch...4 Wiring Instructions Wiring Overfill Alarm with Acknowledgement Switch...5 Wiring Overfill Alarm without Acknowledgement Switch...6 Setup and Test Setting Overfill Alarm Horn Delay Time...7 Testing the Overfill Alarm with the Acknowledgement Switch...7 Setting the Overfill Alarm Horn s Volume Level...7 Testing the Overfill Alarm with the Console...7 Overfill Alarm W/O Acknowledgement Switch...7 Overfill Alarm with Acknowledgement Switch...7 Figures Figure 1. Overflow Alarm mounting dimensions...3 Figure 2. Acknowledgement Switch mounting dimensions 4... Figure 3. Overfill Alarm/Acknowledgement Switch wiring connections...5 Figure 4. Overfill Alarm only wiring connections...6 i

ii Table of Contents

Introduction Compatible Consoles Related Manuals Contractor Certification Requirements

Safety Symbols OFF Safety Warnings

Mounting Instructions Overfill Alarm and Acknowledgement Switch Dimensions Figure 1 shows the Overflow Alarm mounting dimensions and Figure 2 shows the Acknowledgement Switch mounting dimensions. 0.313'' (8 mm) dia. 4 holes 6'' (152.4 mm) Red Flashing Light Hinge side 10.3 '' (261.9 mm) Horn volume adjustment screw (1/16'' Hex Hd) 6'' (152.4 mm) 8'' (203 mm) 4 '' (101 mm) 1.6 '' (40.6 mm) consoles\ovrflwalm.eps 1/2 '' conduit connector 2 '' (50.8 mm) Figure 1. Overflow Alarm mounting dimensions 3

Overfill Alarm/Ack Switch Installation Guide Mounting Instructions 3'' (76.2 mm) 0.313'' (8 mm) dia. 4 holes 2'' (50.8 mm) TEST button (on side) ACKNOWLEDGE Hinge side 1/2 '' conduit connector RESET 6.75" (171.5 mm) 1.4 '' (35.6 mm) 1'' (25.4 mm) 2'' (50.8 mm) consoles\acksw.eps 4.3'' (109.5 mm) Figure 2. Acknowledgement Switch mounting dimensions Mounting Instructions OVERFILL ALARM 1. Select a mounting location where the Overfill Alarm can be seen and heard clearly from the area where the fuel tanks are filled. In addition, consider the ease of routing interconnection conduit. 2. Locate and mark mounting holes using the hole pattern in Figure 1. 3. Mount the Overfill Alarm using the four mounting tabs on the housing. ACKNOWLEDGEMENT SWITCH 1. Select a mounting location where the Acknowledgement Switch can be easily activated by the tank truck driver. In addition, consider the ease of routing interconnection conduit. 2. Locate and mark mounting holes using the hole pattern in Figure 2. 3. Mount the Acknowledgement Switch using the four mounting tabs on the housing. 4. Install conduit between the Acknowledgement Switch, Overfill Alarm, and TLS Console. 4

Wiring Instructions IMPORTANT! Wire used for this installation must have a temperature rating of at least 90 C. be either 14 or 16 AWG, and be color coded. Splicing alarm power with TLS Console power will cause improper operation of the monitor. Wiring Overfill Alarm with Acknowledgement Switch 1. Pull two wires from the switch to the Overfill Alarm. 2. Pull two wires for line and neutral from the switch to the power panel. 3. Pull one wire from the switch to the TLS Console for connection to the alarm relay. 4. Pull one wire for line from the alarm relay in the TLS Console to the power panel. OFF 5. Turn power Off and connect wiring according to the wiring diagram in Figure 3 and Table 1. 1 2 3 Overfill Alarm (cover open) Horn Time Delay Relay Ack Switch (cover open) To Console Relay - See Console Connection Table in this manual 1 2 3 4 5 6 console\ovakwir.eps Customer supplied junction box N L To power panel Figure 3. Overfill Alarm/Acknowledgement Switch wiring connections 5

Wiring Overfill Alarm without Acknowledgement Switch OFF 1 2 3 Overfill Alarm (cover open) Horn Time Delay Relay To Console Relay - See Console Connection Table in this manual Customer supplied junction box console\ovwir.eps N L To power panel

Setup and Test Setting Overfill Alarm Horn Delay Time 1. Loosen the four screws that secure the Overfill Alarm cover clamps to the case. Slide the clamps away from the retaining lip on the door. Open the door. 2. Locate the Horn Time Delay Relay (see Figure 3). 3. Adjust the time the horn remains On from 0 to 60 seconds by turning the knob on the relay to the desired setting. 4. Close the door and tighten the four cover screws. Testing the Overfill Alarm with the Acknowledgement Switch Turn On power to the Overfill Alarm and Acknowledgement Switch. Depress and hold in the TEST Button on the right side of the switch. The Overfill Alarm horn will sound immediately, and the Overfill Alarm s red light will start flashing. The horn will turn Off at the preset delay time you set above (0-60 seconds). The red light will continue to flash until the TEST button is released. Setting the Overfill Alarm Horn s Volume Level 1. Locate the adjustment set screw (1/16 Hex wrench) on the exterior of the Overfill Alarm s horn cover (see Figure 1 on page 3). 2. Turn the adjustment screw counterclockwise to increase the db level of the horn or clockwise to decrease its db level. Testing the Overfill Alarm with the Console 1. With the Overfill Alarm and Acknowledgement Switch (if installed) connected to the console, consult the Setup manual for your console and perform the Output Relay setup procedure to recognize the Overfill Alarm. OFF 2. Turn power Off to the console and the Overfill Alarm. Put a jumper between the two Overfill Alarm relay connections in the console. OVERFILL ALARM W/O ACKNOWLEDGEMENT SWITCH 1. Reapply power. If the Overfill Alarm is wired properly, the alarm horn should sound immediately followed by the red alarm light flashing. OFF 2. Turn Off power to the console and to the Overfill Alarm. Remove the jumper between the Output Relay connections. OVERFILL ALARM WITH ACKNOWLEDGEMENT SWITCH 1. Stand by the Acknowledgement Switch and have someone reapply power to the console and Overfill Alarm. If the Overfill Alarm is wired properly, the alarm horn should sound immediately followed by the red alarm light flashing. 7

Overfill Alarm/Ack Switch Installation Guide Testing the Overfill Alarm with the Console 2. Press the RESET button on the front of the switch. The alarm horn and red flashing light should shut off. The ACKNOWLEDGED light on the front of the switch should be On. (Pressing the RESET button shuts Off the alarms but does not clear the alarm. The cause of the alarm must be removed before the ACKNOWLEDGED light will turn Off.) OFF 3. Turn Off power to the console and to the Overfill Alarm. Remove the jumper between the console s Output Relay connections. 4. Reapply power to the console and to the Overfill Alarm. The ACKNOWLEDGED light should now be Off because the cause of the alarm (in this case, the shorting jumper) has been removed. 8

Veeder-Root has sales offices around the world to serve you. Headquarters 125 Powder Forest Drive Simsbury, CT 06070-7684 Tel: (860) 651-2700 Fax: (860) 651-2719 Email: marketing@veeder.com