AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

Similar documents
WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MANUAL RESET ALARM RELEASE

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

MANUAL RESET ALARM RELEASE BOX

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

Hand Chain (Model FCF) &

MANUAL RESET ALARM RELEASE

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

OWNER S MANUAL. Extended Performance Release Device. Models: Firefly III Plus, Firefly III Plus with Voiceboard

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor

SP-1000X. Panic Device Power Controller Installation Guide. Rev

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Installation Guide for models:

Remote Alarm Panels Features

INSTALLATIONN GUIDE & OPERATION MANUAL

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Installation Guide for models:

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

FDF Foam Pump Controllers Features

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

INSTALLATION INSTRUCTIONS TALKBACK MODULE

SECAP Conveyor TC72 / Dryer TD72

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Series. Access Power Controllers. Installation Guide

ESRB and ESRN Installation & Safety Instructions

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Pump-Up Controller MODEL 4062

Model 17A00 Expansion Enclosure

DIESEL Engine Fire Pump Controllers Features

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Pump-Down Controller MODEL 4052

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Conventional Releasing Control Panel

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

TOTALPAC2 Integrated Fire Protection System

SP40S-D. Kingfisher Company, inc. Features: Description:

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

SECTION AUTOMATIC TRANSFER SWITCHES

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

TS93 EMF SERIES. INSPK NO Rev.03/10

SECTION AUTOMATIC TRANSFER SWITCHES

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

Wiring Instructions (01-09)

Operator: Save these instructions for future use!

FM-200 In-Cabinet Series

Multiple Input and Output Modules

Instructions for Installation, Operation, Care and Maintenance

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

DIESEL Engine Fire Pump Controllers Features

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Public Safety DAS Annunciator Panel

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Operation & Maintenance Manual

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.)

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Instructions

Power Supply Display Module PSDM. Installation and Operation Manual

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

50A Integrated Furnace Control

Transcription:

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AR C Rev.06

WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device systems, maximum fire protection is provided when installed in accordance with factory specifications and used with fuse link systems. 2. DO NOT install this unit without fuse links. 3. Installation and testing to factory specifications shall be performed by factory authorized personnel for proper operation in accordance with all of the latest National fire Protection Association (NFPA), Underwriters Laboratories (UL), National electrical Code (NEC), local, state, county, district and/or other applicable building and fire standards, guidelines, regulations and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). 4. To be performed by factory authorized personnel only. 5. Clear fire door opening and prohibit all traffic through door opening during testing of system! Installation Tip: Test this unit before installing onto a fire door system. Test and learn the release mechanism before connecting to a fire door. INTRODUCTION The releasing device is a failsafe constantly energized solenoid mechanism. It is designed for use on rolling doors, single-slide and center-parting level and inclined track doors. Inside the mechanism, contact relays receive the alarm signal from the fire alarm control panel. When the unit receives the signal, the power to the solenoid is cut, releasing the fire door mechanism and hence close the fire door. The alarm signal is Form C dry contact. Any interruption of power will release the solenoid mechanism. The release has a 5~10 second delay on alarm and automatic reset. When power and alarm are restored, the unit will reset itself automatically. 1

SPECIFICATION Input Power: 115VAC, 0.12A; 230VAC, 0.06A Alarm Dry Contact Rating: 24VDC, 0.4A, 2.64 ohms max line impedance Frequency: 50Hz or 60Hz Release Pull: 12.8 lbs ( 5.8 kgs) Fuses: F1: 3A@250V, Slo-Blo Type F2: 2A@250V, Slo-Blo Type Must install with UL approved fusible links. 18-gauge wire recommended. For Indoor Dry location use only. The releasing device should only be used with Lawrence hand chain and crank units, FGRL and FGH operators (Not applicable for larger than 2hp). Per NFPA72, 2007 edition paragraph 6.16.6.4 Magnetic door holders that allow doors to close upon loss of operating power shall not be required to have a secondary power source. This alarm release does NOT require battery back up. INSTALLATION WARNING Disconnect power supply before servicing. - For Indoor Dry location use only. All wiring must satisfy the most current version of NFPA72 National Fire Alarm Code and the National Electric Code. - 18-gauge wire is recommended 2

INSTRUCTION & DRAWING For Model FHC and FHK: Replace fusible link release with alarm release box. Loosen screws and legs. Use the included screws, legs and brackets to mount the alarm release. See drawing below for reference. 3

Warnings and Operation. Wire connections. Pull cable to close fire door. Fusible Link Connection Consult NFPA-80 and the authority having jurisdiction for location(s) and method. Must remove cotter pin after fusible link connection and installation. 4

For Model FHCM and FHKM: Replace fusible link release with alarm release box. Loosen screws and remove plunger. Use the included screws and brackets to mount the alarm release. See drawing below for reference. 5

Warnings and Operation. Wire connections. Fusible Link Connection Consult NFPA-80 and the authority having jurisdiction for location(s) and method. Pull cable to close fire door. Must remove cotter pin after fusible link connection and installation. 6

For Model FGH: Use the included screws, legs and brackets to mount the alarm release. See drawing below for reference. AR-C Must remove cotter pin after fusible link connection and installation. Fusible Link Connection Consult NFPA-80 and the authority having jurisdiction for location(s) and method. 7

For Model FGRL: Use the included screws, legs and brackets to mount the alarm release. See drawing below for reference. AR-C Must remove cotter pin after fusible link connection and installation. Fusible Link Connection Consult NFPA-80 and the authority having jurisdiction for location(s) and method. 8

WARNING Disconnect power supply before servicing. 1. ELECTRICAL CONNECTIONS All models Installation of all wiring and connections shall be performed in accordance with, but not limited to, the latest NFPA, U.L. and N.E.C. standards. In addition, all installations subject to Canadian standards shall be performed in accordance with the Canadian Electrical Code, Part I, with respect to wiring material, wiring gauge related to power capacity requirements and circuit length and wiring methods. 2. Verify voltage rating of release device to power source being utilized. 3. Connect fusible link and fire door system to release box. 4. Connect power and alarm connection to the unit. TESTING 1. Simulate an alarm condition and see if the solenoid disengages and releases the fire door. 2. Simulate a power failure and see if the solenoid disengages and releases the fire door. RESETING 1. Make sure power and alarm connection is normal. 2. Verify the solenoid is holding. 3. Connect fusible links to the fire door system. Note: If the power or the alarm is not normal, solenoid will not hold. Hence the release rod will not stay in the slot. Warning: Must perform drop-test after installation. 9

WIRING WARNING Disconnect power supply before servicing. WIRE ROUTING F2 F1 2 1 MOV2 MOV1 TERMINAL CONNECTIONS WARNING Disconnect power supply before servicing. TB1 L N Input power 115VAC or 230VAC TB3 1 2 Alarm Dry Contact 10

WIRING DIAGRAM 11

12

SCHEMATIC μ μ μ μ 13

MAINTENANCE INSTRUCTIONS WARNING Disconnect power supply before servicing. Check the following items at the intervals listed: CHECK LIST DESCRIPTION EVERY 3 MONTHS EVERY 6 MONTHS EVERY 12 MONTHS Fasteners Check & tighten as required Drop-test Inspect door, drop-test for proper operation and full closure per NFPA-80 Inspect and service whenever a malfunction either door or release device is observed or suspected. Before servicing, always disconnect power supply to the release device. Replace fuses only with those of the same type and rating. All replacement parts must be obtained from the door manufacturer per NFPA-80. Testing of the AR release device is independent of, and shall in no way be interpreted as an alternative method of, testing of the fire alarm system, and/or any other system component employed on the fire door or counter fire door installation. TESTING SHALL BE PERFORMED AND WITHNESSED FOR PROPER OPERATION. 14