CAFIL. Heat recovery accessories. Heat recovery unit Accessories. Mounting accessories

Similar documents
CADB/T-D DP25 F7 Series CADB/T-DI DP25 F7 CADB/T-DC DP25 F7. Heat recovery units CADB/T-D

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

Process glycol chillers

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

FMC(Z) cartridge filter

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

TopMaster Air Handling unit. Technical data

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Air Handling Units. T F E.

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Fan heater SWT Ceiling mounted fan heater with water heat

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

Outside Air Requirements... SOLVED!

The Sentinel Kinetic Horizontal Range

Halton Rex 600 Basic R6B - Active chilled beam

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Halton CHB Active chilled beam with boost function for bulkhead installation

DOMEKT. Residential ventilation units

CITY OPEN - CITY BOX from 25 to 35 kw

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Halton Rex for Vario R6O - Variable air volume chilled beam

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

QZHW Fan Coil Unit. Key features. Specifications

Units for suspended ceilings

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Frost Units for air temperature monitoring

CAST IRON ATMOSPHERIC BOILERS

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

GREEN REFRIGERANT R-410A

WOLF VENTILATION SYSTEM PRICE LIST

TECHNICAL SPECIFICATION

DATATECH. Precision air conditioners for technological environments 6 220

Fire dampers. For diverse applications

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Air heater/cooler in combination with ground source heat pump

ENERGY TOP. Condensing boiler solutions

VORT NRG RANGE COMMERCIAL VENTILATION NEW

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

KOMFORT EC DB Suspended heat recovery air handling units

LOW NOx MODULATING GAS BURNERS

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Küba SG commercial

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

E U R O V E N T CERTIFIED PERFORMANCE

UNITES TERMINALES ET MINI CTA FIDJI

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Electric Coils. Blower Coils. Product Information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

v SELECTION GUIDELINES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE Dehumidifiers for radiant cooling systems with heat recovery

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

The computer for optimum climate in every pig house

HYDRONIC RESIDENTIAL

Aegean Range. A new range of fan coils for heating and cooling commercial applications

BRISE. Heating and cooling from a single radiator

The Sabiana. of Fan Coil

Application guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

The ultimate in air handling units: directly and indirectly fired

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

BATHROOM EXTRACT FANS SILENT-100 Series

BARKELL AIR HANDLING UNITS

Installation, Operation & Maintenance Instructions Document Ref:

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

TopVent Design Handbook

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Specification data. Rotovex SR IAQ. Air handling units Airflow m 3 /h.

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

HERZ Differential Pressure Control Valve 4002

Technology for life. Unit heater LH

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

YFCN Fan Coil Unit centrifugal fan

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

The Straight Way K Sileo Series

Transcription:

Heat recovery accessories Mounting accessories CFIL Filtering boxes without a built-in filter and made from galvanised steel. To assemble FR-D/DI/DC-G4, FR-D/DI/DC- o FR-D/ DI/DC- filters. They incorporate round flanges with a tight seal and an easy-opening cover for easy filter replacement. They include a perimetrical frame for filter support. Dimensions L H Ø CFIL-2 4 2 27 2 7 CFIL-2 42 32 2 1 CFIL-315 6 6 315 19 CFIL-355 6 64 57 355 25 CFIL-4 9 575 57 4 29 CFIL-63 61 69 56 35 CFIL-71 13 71 44 Filtering boxes Filter models model G4 F7 CFIL-2 FR-D/DI/DC 5 G4 FR-D/DI/DC 5 F7 FR-D/DI/DC 5 CFIL-2 FR-D/DI/DC 8 G4 FR-D/DI/DC 8 F7 FR-D/DI/DC 8 CFIL-315 FR-D/DI/DC 18 G4 FR-D/DI/DC 18 F7 FR-D/DI/DC 18 CFIL-355 FR-D/DI/DC 3 G4 FR-D/DI/DC 3 F7 FR-D/DI/DC 3 CFIL-4 FR-D/DI/DC 45/56 G4 (2 units) FR-D/DI/DC 45/56 F7 (2 units) FR-D/DI/DC 45/56 (2 units) CFIL-63 FR-T/TI/TC 8 G4 (2 units) FR-T/TI/TC 8 F7 (2 units) FR-T/TI/TC 8 (2 units) CFIL-71 FR-T/TI/TC 12 G4 (2 units) FR-T/TI/TC 12 F7 (2 units) FR-T/TI/TC 12 (2 units) Pressure loss in the filters CFIL-2 8 6 4 2 2 3 4 m 3 /h 9 8 7 6 4 3 2 1 2 3 4 6 7 8 m 3 /h 12 8 6 4 2 CFIL-2 CFIL-355 1 2 2 3 m 3 /h 7 6 4 3 2 1 2 1 CFIL-315 2 4 6 8 12 14 16 m 3 /h CFIL-4 2 3 4 6 m 3 /h

Mounting accessories CFIL Pressure loss in the filters Ä P 2 2 CFIL-63 P 175 1 125 CFIL-71 1 75 25 2 3 4 6 7 8 m 3 /h 2 4 6 8 m 3/h SIFÓN RECUPERDORES Heat recovery unit water drain siphon. 21 92 76 32 26 161 Electrical accessories 3WV CD/T-DC ed 3-way ball valve. Stainless steel ball and axle. Proportional servo motor C/DC 24 V. Servo motor: Voltage: 24 V. r: 2 Nm. Motor running time: 9 s. Control signal: -1 V. [m 3 /h] 2 8 6 4 3 2 1 8 6 5 4 3 2.1 1.8.6.5.4.3.2.1 1.2 2.3.4.5.6.8.1 3 4 56 Valve Dimensioning Diagram 8 1.2 p v [bar] 3 WV CDT-TC 12 3 WV CDT-DC 45/56 3 WV CDT-TC 45 3 WV CD-DC 5/3 3 WV CD-DC 8/18 2.3.4.5.6.8 DN k vs 1 3 4 6 8 p v [k] 2 2 For silent running operation p V : Differential with valve fully opened 3 4 56 pmax 8 1 3 4 6 8 56 28 22 17 14 11 8.3 5.6 2.8 2.2 1.7 1.4 1.1.83.56.28.22.17.14.11.8.6.3 [l/s] Valve Connection Diagram M DN TERÍ Coil water DE GU DN (") Kvs 3 WV CD-DC 5/3 15 1/2 2,5 3 WV CD-DC 8/18 15 1/2 1,6 3 WV CDT-DC 45/56 2 3/4 6,3 3 WV CDT-TC 45 2 3/4 4 3 WV CDT-TC 12 32 11/4 16 V : Nominal flow at p V

Electrical accessories RQ3 utomatic speed regulator, depending on CO 2 concentration. Works in conjunction with a CO 2 probe (environment: SCO2-1/1V and SCO2-D or conduit: SCO2-G). TRNSFORMER CD/T-DC 2V/24V C Transformer to power the valves. SCO2- /1V / SCO2-D SCO2- /1V mbient CO 2 and temperature sensor. Enables control of the ventilation in sections of conduit according to the temperature and relative humidity of the air circulating through it or to the temperature. SCO2-G /1V CO 2 sensor probe for duct mounting. Enable control of the ventilation in ductwork according to the CO 2 concentration of the air circulating through it. SCO2-D mbient CO 2 and temperature sensor with display. Enable control of the ventilation ductwork according to the temperature and relative humidity of the air circulating through it or to the temperature. SCO2-G /1V Electrical supply (W) Voltage (V) IP CO 2 range (pm) Dimensions LxxH 24VDC-24VC 5-1 ox IP65-2 8x238x8 Electrical supply Voltage (W) Height installation (m) IP CO 2 range (pm) Temperature range (ºC) Dimensions LxxH SCO2- /1V 24VDC- 24VC SCO2-D 5-1V 4-2m 1,5-3,5 IP2-2 - 85x26x For controlled equipment only a -1 V probe can be connected.

Electrical accessories Electric heater batteries The heater battery operation must be enslaving to the fan operation. The installation must include a switch to switch off the electric heater battery supplies in case of fan failure. E-SCT Electric heater batteries with built-in electronic temperature control. - uto-resetting thermal protector 55ºC. - Manual resetting thermal protector 7ºC. - uilt-in electronic temperature control. - Conduit temperature probe and potentiometer. - Pressure switch (optional). Electronic control Electronic control E Electric heater batteries Functions: - Defrosting operation: To heat the outside fresh air before going through the heat recovery unit to avoid frost accumulation ans sealing of the heat exchanger. - Post heating operation: To increase the temperature of the supply air, after the heat exchanger. Electric heater batteries Minimum airflow (W) E-2/2M 23 2 E-2/3M 355 3 E-315/4M 56 4 E-355/6T 715 6 E-4/9T 715 9 E-4/9T 715 9

ccessories for air treatment -C External coil module for hot water. Made from galvanised steel. Round connections to pipe the supply circuit inlet of the exchanger. Maximum flow Flow rate (m/s) ir input (ºC) (kw) ir output (ºC) Loss of water (k) Waterflow (l/h) Loss of air (k) -C 5 3,8 5,6 3 23,1,9 26 48 34 32 275 2 175 1/2" 5 -C 8 8 3 6,6 5,6 27,4 2,6 494 45 4 368 275 2 175 1/2" 7,2 -C 18 19 3,9 5,9 12,3 25,1 17,4 183 65 464 3 315 2 1/2" 11,5 -C 3 3 3,5 6,2 2,3 16,3 11,3 1787 6 56 3 355 2 1" 16 -C 45 4 4,3 6,6 27,5 24,8 21,5 2425 65 8 62 3 4 2 1" 18 -C 56 56 5,3 6,3 29,9 22,2 23,3 2639 9 8 62 3 4 2 1" 18 Values under the following conditions: T water input: 7ºC, T water output: 12ºC C D E Ø

ccessories for air treatment -F External coil module for cold water. uilt with aluminium profiles and a double panel of pre-painted galvanised sheet and 25 mm insulation. With a stainless steel condensates collecting tray. Round connections to pipe the supply circuit inlet of the heat recovery unit. Technical specifications Cold water coil Flow Flow rate (m/s) ir input (ºC/% HR) (kw) ir input (ºC/% HR) Loss of water (k) Loss of air -F 5 2,96 35/ 5,25 23-82 14,73 8,51 483 36 483 2 3 -F 8 8 2,147 35/ 8,39 23-83 14,96 83,81 56 41 483 2 38 -F18 18 2,614 35/ 17,41 23-84 13,29 116,23 56 625 483 315 -F 3 3 2,54 35/ 3,8 23-83 18,3 11,94 7 7 5 355 75 -F 45 4 2,667 35/ 44,94 23-83 22,26 12,44 875 875 5 4 95 -F 56 56 2,676 35/ 55,7 23-83 2,28 121,13 875 5 56 11 -F 8 8 2,673 35/ 79,85 23-85 2,9 12,93 175 175 5 63 135 -F 12 12 2,635 35/ 117,39 23-84 13,21 117,89 1325 1275 7 71 24 Values under the following conditions: T Water input: 7ºC, T water output: 12ºC () L ØD ir direction Connections can be installed on the right-hand-side or on the left-hand-side of the equipment. The connection side is determined by looking at the equipment from the air outlet side.

ccessories for air treatment HUMC diabatic cooling module. Cellulose panel cassette, mm. thick, mounted on the casing with aluminium profiles and galvanised steel panels, and 25 mm-thick laminated double wall. Galvanised sheet condensates collecting tray. 3/4 continuous draining and purging pipes and 3/8 filling tube with float valve. Damper for accessing the recirculation pump on the same side as the connections. Single-phase recirculation pump at 22V. Possibility to choose left or right-hand side for the connections and the damper (looking at the equipment on the upstream side). diabatic module Maximum airflow C D Ø Loss of () Pump power HUMC-5 4 4 287,5 2 27 2, 13,96 HUMC-8 8 312,5 2 41 23, 13 1,32 HUMC-18 18 6 6 362,5 315 67 31, 2 2,43 HUMC-3 3 12 7 7 437,5 355 37, 2 5,4 HUMC-45 4 12 9 9 512,5 4 46, 2 8,86 HUMC-56 56 12 9 9 537,5 4 56 54, 1,95 HUMC-8 8 12 12 562,5 63 59 64, 15,65 HUMC-12 12 14 13 13 712,5 71 59 8, 16,7 * Recirculation pump power at 23V/Hz. (W)* Pump flow (l/h) Damper cover Hopper Humidifier Hopper ir direction Connections can be installed on the right-handside or on the left-hand-side of the equipment. The connection side is determined by looking at the equipment from the air outlet side.