Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

Similar documents
READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Vapor-logic 3 to Vapor-logic4

VT Series. Service Kit Manual CAUTION

XTR. Electrode Steam Humidifier

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access I nteroperability via Modbus or optional BACnet or LonTalk

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

THE SIX STEPS OF HUMIDIFICATION DESIGN

GTS. User Manual. Gas-to-Steam Humidifier. Affix product label here.

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access Interoperability via Modbus or optional BACnet or LonTalk

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

Humidifi er FAQ. Why is the humidifier not running? The following conditions need to be satisfied before the humidifier sequence can start:

Industrial Descale Solutions & Descale Services

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

READ AND SAVE THESE INSTRUCTIONS SEISMIC. Cer tification Option. Installation Manual

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

Zep Dyna Clean Installation and Operator's Manual

Lime Buster III. Model LB-300P IMS # (CIC1-LB300P) INSTRUCTION MANUAL

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

Ultra-sorb Models LV and LH

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

RANCONA V RS Fungicide

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

D-W SURFACTANT NONIONIC SPREADER-WETTER

NO SCALD DPA EC- 283 FOR CONTROL OF STORAGE SCALD ON APPLES. GUARANTEE: Diphenylamine Kg/liter NET CONTENTS: 19 LITERS

CYCOCEL EXTRA LIQUID PLANT GROWTH REGULATOR

COMMERCIAL. GUARANTEE: daminozide... 85% NET Contents: 500 grams, 25 kg 24 Hour Emergency Phone: (519)

RootShield PLUS WP - Biological Fungicide

BONZI PLANT GROWTH REGULATOR COMMERCIAL. For Use on Container Grown Ornamental Bedding Plants and Plugs. GUARANTEE: Paclobutrazol...

READ THE LABEL AND LEAFLET BEFORE USING KEEP OUT OF REACH OF CHILDREN

Rules for Safe Operation

POISON S6 NOT TO BE TAKEN KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING

FRONT BUMPER COVER - VIN RANGE: H18680->H99999 (G )

DELIVER DX2 WATER CONDITIONER - SURFACTANT - DEPOSITION AID SEE BACK OF CONTAINER FOR STATEMENT OF FIRST AID AND GENERAL INFORMATION

Pesticide Applicator Equipment Cleaning to Prevent Carryover. Chuck Schuster University of Maryland Extension

IMTRADE PICKER HERBICIDE ACTIVE CONSTITUENT: 300 g/l TRICLOPYR present as butoxyethyl ester 100 g/l PICLORAM present as hexyloxypropylamine salt

SECTION 18 EMERGENCY EXEMPTION API LIFE VAR

B-Nine WSG. Water Soluble Granule Plant Growth Regulator. Controls Height, Promotes Flowering of Plants

Material Safety Data Sheet

Radiator Additive. ZetaLube. Description

Literature Published on

SPRAY AIDE COMPATIBILITY-ACIDIFIER-SURFACTANT AGENT PRINCIPAL FUNCTIONING AGENT:

RAMPART FUNGICIDE COMMERCIAL SOLUTION REGISTRATION NO PEST CONTROL PRODUCTS ACT READ THE LABEL BEFORE USING KEEP OUT OF REACH OF CHILDREN

Allegro 500F Agricultural Fungicide

INDUSTRIAL - AQUEOUS PARTS CLEANER EM1435A AIR OPERATED

Bayer Environmental Science

KEEP OUT OF REACH OF CHILDREN CAUTION

Material Safety Data Sheet

R100 Oil-Less Refrigerant Recovery Unit

Ultra-sorb Steam Dispersion Panels

TALON RODENTICIDE PELLETS FOR MICE & RATS

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

MaxCel PLANT GROWTH REGULATOR COMMERCIAL CAUTION KEEP OUT OF REACH OF CHILDREN READ THE LABEL BEFORE USING

Dithane* M-22 80% W.P. Fungicide

Material Safety Data Sheet

ROOTING POWDER. Bontone II. Speeds root development. Keep Out Of Reach Of Children. Net Weight 1 ¼ OZ. (35 grams)

MPOWER Good Harvest HERBICIDE AND CROP DESICCANT SOLUTION FOR SALE FOR USE IN THE PRAIRIE PROVINCES AND PEACE RIVER REGION OF BRITISH COLUMBIA ONLY

SIGNATURE XTRA STRESSGARD. Fungicide

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

B.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.

_Insect Repellent Permethrin Ben's Complete Clothing & Gear_ _14_56575_.pdf. Front

USER'S INFORMATION MANUAL

Approved Pamphlet MERTECT SC Page 1 of 5 MERTECT SC

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

Approved Pamphlet INSTRATA Page 1 of 7. INSTRATA Fungicide READ THE LABEL AND PAMPHLET BEFORE USING KEEP OUT OF REACH OF CHILDREN

BIOACTIVE COIL TREATMENT FOR TREATMENT OF AIR CONDITIONING HEAT EXCHANGE COILS

KEEP OUT OF REACH OF CHILDREN CAUTION

MAXIM MZ PSP Potato Seed Protectant Powder

For Control of Varroa Mites and Small Hive Beetles in Honeybee Colonies. Active Ingredient: Coumaphos.. 10% Other Ingredients:... 90% Total...

HWX GAS BOILERS USER S INFORMATION MANUAL

Approved MAXIM PSP Page 1 of 5 MAXIM PSP

STORAGE AND DISPOSAL PESTS CONTROLLED BY TEMPO SC ULTRA PREMISE SPRAY* OUTDOOR PEST CONTROL CONTROL OF WOOD INFESTING PESTS

BLEACH 2 NET2QT(64FLOZ)1.89L

_toilet bowl cleaner cleans and disinfects up & up_ _38_70271_.pdf. toilet bowl cleaner. cleans and disinfects

For the control of powdery mildew in greenhouse vegetables, greenhouse ornamentals and Cannabis (marihuana) that is produced commercially indoors.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

A Seed Treatment Fungicide for seed and seedling protection against certain seed-borne and soil-borne diseases on labeled crops.

FLOREL PLANT GROWTH REGULATOR LIQUID COMMERCIAL

D Dissolution Units Mixing Training Course P/N Rev. C

Mixing Training Course P/N Rev. D

Gopher Killer. Poison bait for use against pocket gophers. in lawns. Helps to protect flower bulbs at fall planting GOPHERTOX

INDUSTRIAL - AQUEOUS PARTS CLEANER

Disposal Manual. m{zd{ 6. Capacitor( -ELOOP ) October 2012 Mazda Motor Corporation

_Sanitizer FS_ _7_8722_.pdf This product contains no phosphorus.

Steam humidification: Reducing energy use, airstream heat gain, and condensate production

ALL PRODUCTS BROCHURE

BLEACH. Protects and Keeps Clothes Whiter Longer + CONCENTRATED

Material Safety Data Sheet

DIURON 80DF For Control of Many Annual and Perennial Grasses and Herbaceous Weeds

Active Ingredient Formic Acid (including formates) 42.25% Other Ingredients % Total % KEEP OUT OF REACH OF CHILDREN

ICE BANK DESCALER & ICE MACHINE CLEANER

weed and grass killer

weed and grass killer

FOLPAN 50 WP (FOLPET) FUNGICIDE COMMERCIAL

PARABOND DETACH II Adhesive Remover

Bleach1. regular. Concentrated NET 2 QT (64 FL OZ) 1.89 L DANGER KEEP OUT OF REACH OF CHILDREN. Disinfects Deodorizes Brightens Laundry Removes Stains

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

c-series Water Bath Additive

Transcription:

IMPORTANT: Read and save these instructions. Humidifier De-scaling Solution and Neutralizer Usage Instructions Before Humidifier De-scaling Solution After Humidifier De-scaling Solution

S a f e t y i n s t r u c t i o n s Humidifier De-scaling Solution Humidifier De-scaling Neutralizer CAUTION! Humidifier De-scaling Solution contains sulfamic acid and citric acid. May be harmful if swallowed. Avoid contact with skin and eyes. Avoid breathing mist. Use with adequate ventilation. Keep container closed. FIRST AID Eyes: Flush immediately with cool water for 15 minutes. Contact physician immediately. Skin: Flush immediately with cool water for 15 minutes. Call physician immediately. Inhalation: Remove to fresh air. If any irritation persists, call physician immediately. Ingestion: DO NOT INDUCE VOMITING. If conscious, give large amounts of water. Call physician immediately. Storage and handling instructions Wear all protective equipment. Store away from and do not mix with strong bases. Use with adequate ventilation. Keep container closed when not in use. Wash thoroughly after handling product. Do not smoke near containers. Store away from food. Wash contaminated clothing before reuse. Keep from freezing CORROSIVE 8 If frozen, allow slow return to room temperature and mix thoroughly before using. CAUTION! Humidifier De-scaling Neutralizer contains soda ash. Irritates eyes. Avoid eye or prolonged skin contact. Avoid breathing dust. Use with adequate ventilation. May form caustic when combined with lime in presence of moisture. May be harmful if ingested. FIRST AID Skin: Flush with water. Eyes: Flush with plenty of water for at least 15 minutes and get medical attention. Ingestion: Drink plenty of water to dilute; DO NOT induce vomiting and get medical attention Inhalation: Remove to fresh air and get medical attention. Storage and handling instructions Wear gloves, goggles, and dust mask when handling When dissolving, add to stirred water slowly to minimize heat evolution. Store in closed drum in dry area away from acid. May absorb moisture from air. Refer to MSDS for additional information. For industrial use only. Keep out of reach of children. CAUTION! DRI-STEEM is not responsible for improper handling, any health side effects, or humidifier damage due to use of the de-scaling agent or neutralizer. See the product label and material safety data sheet (MSDS) for specific directions related to handling, usage, and disposal. Follow all governing codes regarding discharging into drains. Refer to MSDS for additional information. For industrial use only. Keep out of reach of children. Page DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions

The following are instructions for using DRI-STEEM Humidifier De-scaling Solution and DRI-STEEM Humidifier De-scaling Neutralizer to remove scale and other related deposits in industrial and commercial humidifiers. Safety gear Use proper safety gear including the following: Rubber or neoprene gloves Anti-splash goggles Rubber apron and/or boots Dust mask when using Humidifier De-scaling Neutralizer IMPORTANT! Scale buildup on humidifier heaters and heat exchangers acts as an insulator, reducing humidifier performance while increasing energy costs. Inspect humidifier tanks regularly and perform humidifier de-scaling maintenance as needed to keep humidifiers operating at peak efficiency. Supplies required Humidifier De-scaling Solution Humidifier De-scaler Neutralizer, if required by federal, state or local codes ph meter or indicator strips (ph test strips are included with the De-scaling Solution) Portable mixer (optional) (e.g., cordless drill with mixer attachment or stir stick) Humidifier Installation, Operation, and Maintenance manuals (IOMs) for reference Tools for servicing Additional water source (e.g., plastic bucket and hose) IMPORTANT: These products are not to be used for cleaning DRI-STEEM XT humidifiers. XT humidifiers have disposable evaporating chambers that do not require cleaning. De-scaling process for GTS, STS, LTS, Vaporstream humidifiers IMPORTANT: See the section titled De-scaling process for Vapormist, CRUV, Humidi-tech, and VT humidifiers for instructions regarding these humidifiers. 1. Review MSDS sheet for safe handling and proper use of Humidifier De-scaling Solution and Humidifier De scaling Neutralizer, in addition to instructions provided in this document. 2. Remove the humidifier from service before beginning to clean the humidifier. This can be accomplished by turning off power to the humidifier. IMPORTANT: If the humidifier has a normally open drain valve (typical on units installed in outdoor enclosures), the humidifier must remain powered to keep the drain valve closed. To remove from service a humidifier with a normally open drain valve, use the Vapor-logic keypad/display to change the control mode from Auto to Standby. 3. Refer to your humidifier IOMs for specific information regarding how to prepare the humidifier for service. DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions Page

4. Remove the humidifier tank cover. If you have a GTS04 humidifier, access the tank through the probe plate. 5. Drain the humidifier to remove loose deposits and test for any draining issues prior to adding Humidifier De-scaling Solution. Use the manual override or ball valve for draining IMPORTANT: If the humidifier has a normally open drain valve, change the control mode using the Vapor-logic keypad/display from Standby to Manual Drain. 6. When draining is complete, close drain valve. IMPORTANT: If the humidifier has a normally open drain valve, change the control mode using the Vapor-logic keypad/display from Manual Drain to Standby. 7. If the humidifier is in an air handler, shut down air handler prior to cleaning. CAUTION! Using the Humidifier De-scaling Solution can result in off-gassing of carbon dioxide and/or non-hazardous fumes. 8. See the table on the last page of this document for recommended amount of Humidifier De-scaling Solution. 9. Fill the humidifier with cold water halfway to the overflow port. 10. Turn power off to the humidifier if not already done, or place in Standby Mode for humidifiers with a normally-open drain valve. 11. CAUTION! Remove probe assembly from humidifier before adding Humidifier De scaling Solution to prevent damaging probe. 12. Add the amount of Humidifier De-scaling Solution to the half-full tank per the table on the back cover of this document. 13. After the Humidifier De-scaling Solution is added, finish filling the humidifier with water manually (e.g., using a bucket) to 1" (25 mm) below the overflow port. CAUTION! Be careful to avoid splashing solution on skin or in eyes while adding the remaining water. Use proper safety gear. 14. Use a portable mixer or similar device to agitate and mix the solution. 15. Place the cover on the humidifier slightly ajar to allow the solution to be vented. 16. Maintain a solution ph between 2 and 4 by adding additional De-Scaling Solution as needed. Use proper safety gear. 17. De-scaling duration depends on several factors including: quantity of scale, type of scale, and the ph of the solution. The de-scaling process can last up to 8 hours. Page DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions

18. Allow the solution to dissolve scale while checking on the progress every 2 hours up to a maximum of 8 hours. For increased performance, continue agitation throughout the de-scaling process and maintain a ph close to 2. 19. De-scaling is complete when the majority of scale has been dissolved or after 8 hours has passed. 20. After de-scaling is complete, dilute the solution to a ph between 5 and 9. This can be accomplished by either manually filling the humidifier while allowing diluted solution through the overflow port, or by adding Humidifier De scaling Neutralizer (see instructions below). Measuring ph Measure ph by using a ph meter and probe, or by using ph paper strips with a color key (provided with De-scaling Solution). If using a ph meter and probe, follow the instructions that came with your ph meter and probe. If using ph paper strips, insert a strip into the tank water and remove. Compare the color of the strip to the color key to determine ph. CAUTION! Do not leave humidifier unattended while diluting or neutralizing to avoid spills or overflowing. 21. For neutralization use the following steps: a. Measure the ph of the solution in the humidifier tank. b. Measure out 1 lb of Humidifier De-scaling Neutralizer per 1 gallon of Humidifier De-scaling Solution used (see the table on the last page of this document for reference). c. SLOWLY, add the Humidifier De-scaling Neutralizer to the humidifier while monitoring the level of solution in the humidifier. CAUTION! The combination of the two chemicals will cause bubbling and release of carbon dioxide. If the neutralizer is added too quickly, the humidifier can overflow. d. Alternately, agitate the solution to ensure proper mixing. e. Once the neutralizer has been added and bubbling has stopped, measure the ph. Neutralized ph should be between 6 and 8. f. If ph is not between 6 and 8, add acid (De-Scaling Solution) to lower ph, or add base (De-Scaling Neutralizer) to raise ph until ph is in the range of 6 to 8. 22. After dilution has been completed, drain the humidifier while abiding by federal, state, and local codes. Figure -1: Typical overflow port, drain locations STS humidifier Drain valve Overflow port OM-938M 23. Rinse the humidifier thoroughly by refilling and draining until humidifier water ph matches ph of incoming water (typically ph 6-8). 24. If significant scale remains, remove manually or repeat the cleaning process. Note that some residual scale may remain. 25. After cleaning is complete and humidifier properly rinsed, re-install probe assembly and return humidifier to service. DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions Page

De-scaling process for Vapormist, CRUV, Humidi-tech and VT humidifiers 1. Review MSDS sheet for safe handling and proper use of Humidifier De-scaling Solution and Humidifier De scaling Neutralizer, in addition to instructions provided in this document. 2. Turn off power to the humidifier at the main disconnect. 3. Remove the shroud from the humidifier (VT and Vapormist only). 4. Allow the humidifier to cool to room temperature. 5. Drain the humidifier using either manual override switch on drain valve or ball valve. 6. After the humidifier has drained, remove the tank from the humidifier. Refer to the humidifier IOM for questions. 7. Place the tank on a level surface and in an isolated location (preferably near a drain). 8. CAUTION! Remove probe assembly from humidifier before adding Humidifier De-scaling Solution to avoid potential damage. 9. Determine the amount of De-Scaling Solution to be used. See the table on the last page of this document for amount. 10. Fill the humidifier with water halfway to the overflow port. 11. Add the pre-determined amount of Humidifier De-scaling Solution to the half-full tank. 12. After the Humidifier De-Scaling Solution is added, finish filling the humidifier with water manually (e.g., using a bucket) to 1" (25 mm) below the overflow port. CAUTION! Be careful to avoid splashing solution on skin or in eyes while adding the remaining water. Use proper safety gear. 13. Use a portable mixer or similar device to agitate and mix the solution. 14. Place the cover on the humidifier slightly ajar to allow the solution to be vented. 15. Maintain a solution ph between 2 and 4 by adding additional De-Scaling Solution as needed. Use proper safety gear. 16. De-scaling duration will depend on several factors including: quantity of scale, type of scale, and the ph of the solution. The de-scaling process can last up to 8 hours. 17. Allow the solution to dissolve scale while checking on the progress every 2 hours up to a maximum of 8 hours. For increased performance, continue agitation throughout the de-scaling process and maintain a ph close to 2. Page DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions

18. De-scaling is complete when the majority of scale has been dissolved or after 8 hours has passed. 19. After de-scaling is complete, dilute the solution to a ph between 5 and 9. This can be accomplished by either manually filling the humidifier while allowing diluted solution through the overflow port, or by adding Humidifier De scaling Neutralizer (see instructions below). CAUTION! Do not leave humidifier unattended while diluting or neutralizing to avoid spills or overflowing. Figure -1: Typical overflow port, drain locations Vapormist humidifier Overflow port 20. For neutralization use the following steps: a. Measure the ph of the solution in the humidifier tank. b. Measure out 1 lb of Humidifier De-scaling Neutralizer per 1 gallon of Humidifier De-scaling Solution used (see the table on the last page of this document for reference). c. SLOWLY, add the Humidifier De-scaling Neutralizer to the humidifier while monitoring the level of solution in the humidifier. CAUTION! The combination of the two chemicals will cause bubbling and release of carbon dioxide. If the neutralizer is added too quickly, the humidifier can overflow. d. Alternately, agitate the solution to ensure proper mixing. e. Once the neutralizer has been added and bubbling has stopped, measure the ph. Neutralized ph should be between 6 and 8. f. If ph is not between 6 and 8, add acid (De-Scaling Solution) to lower ph, or add base (De-Scaling Neutralizer) to raise ph until ph is in the range of 6 to 8. 21. After dilution has been completed, drain the humidifier while abiding by federal, state, and local codes. 22. Rinse the humidifier thoroughly by refilling and draining until humidifier water ph returns to incoming water ph (typically ph 6-8). 23. If significant scale remains, remove manually or repeat the cleaning process. Note that some residual scale may remain. 24. After cleaning is complete and humidifier properly rinsed, reinstall probe assembly, reinstall humidifier tank, make all connections, and return humidifier to service. OM-2000M Drain valve DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions Page

Expect quality from the industry leader For over 40 years, DRI-STEEM has been leading the industry with creative and reliable humidification solutions. For more information www.dristeem.com sales@dristeem.com Technical support 800-328-4447 For the most current product information, visit our Web site: www.dristeem.com Table -1: Humidifier De-scaling Solution and Humidifier De-scaling Neutralizer recommended amounts DRI-STEEM humidifier name Vaporstream (VLC) DRI-STEEM humidifier model 2-1, 3-1, 4-1, 5-1 6-1, 9-1, 12-1, 16-1, 21-1, 25-1 12-2, 18-2, 24-2, 32-2, 42-2, 50-2 18-3, 27-3, 36-3, 48-3, 63-3, 75-3 24-4, 36-4, 48-4, 64-4, 84-4, 100-4 Humidifier De-Scaling Solution amount gallons Humidifier De-Scaling Neutralizer amount lbs 1.5 1.5 2.5 2.5 4 4 5.5 5.5 7.25 7.25 DRI-STEEM Corporation An ISO 9001:2000 certified corporation U.S. Headquarters: 14949 Technology Drive Eden Prairie, MN 55344 800-328-4447 952-949-2415 952-229-3200 (fax) European office: Marc Briers Grote Hellekensstraat 54 b B-3520 Zonhoven Belgium +3211823595 (voice) +3211817948 (fax) E-mail: marc.briers@dristeem.com Continuous product improvement is a policy of DRI-STEEM Corporation; therefore, product features and specifications are subject to change without notice. DRI-STEEM, CRUV, GTS, Humidi-tech, LTS, STS, Vapormist, Vaporstream, and Vapor-logic are registered trademarks of DRI-STEEM Corporation and are filed for trademark registration in Canada and the European community. 2008 DRI-STEEM Corporation STS or LTS GTS Vapormist (VM), CRUV, or Humidi-tech (HT) VT 25 2.5 2.5 50 3.75 3.75 100 13.75 13.75 200 25 25 400 25 25 800 35.75 35.75 100/200 12 12 300/400 13 13 600 19 19 800 22 22 2-4 0.75 0.75 6-8 1.5 1.5 10-16 1.75 1.75 21-34 2.25 2.25 2-4 0.5 0.5 6-8 0.75 0.75 10-16 1 1 Form No. HDS-UI-0208 Page Part No. 890000-170 DRI-STEEM Humidifier De-scaling Solution and Neutralizer Usage Instructions