Food Service Technology Center

Similar documents
Sunglo Heater Model A270 Patio Heater Performance Test

Sunpak Heater Model S25 Patio Heater Performance Test

Food Service Technology Center

Schwank, Model 2312 Patio Heater Performance Test

Food Service Technology Center

PlateScrape Plate Pre-Scrapper Test Report

Food Service Technology Center

Food Service Technology Center

F Prepared by: Kong Sham. Prepared for: PO Box Technology Center

Food Service Technology Center

Metcraft Power Soak Performance Test

Southern California Gas Company Customer Programs Department

Food Service Technology Center

Hot Food Holding Cabinets Test for FWE HLC

Middleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test

Vanguard Powermax 200 Gas-Fired Booster Heater Performance Tests

Market Forge, STP-6E Electric Steamer Performance Test

Precision Temp PT-56 Gas-Fired Booster Heater Performance Tests

AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance Report

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E

Refrigerated Prep Table Performance Testing

Montague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test

AccuTemp STEAM n HOLD, Model 208-D6-3.0 Electric Steamer Performance Test

SIGMADEK, LTD. FIRE TEST REPORT

Cleveland, Model OEB-6.20 Electric Combination Oven Performance Test

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

TurboChef Technologies, Inc. Model D Oven

INFRARED RADIANT HEATERS

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

AN10943 Decoding DTMF tones using M3 DSP library FFT function

Multifamily Energy Efficiency Rebates Application Package

Energy Efficiency Business Rebates Natural Gas Catalog

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

The Baked Food Company

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

Service Parts, Kits and Accessories

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

Electric radiator test

Duct Mount. Installation Instructions

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

GS-12 GREEN SEAL STANDARD FOR OCCUPANCY SENSORS FIRST EDITION FEBRUARY 14, 1997

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

2010 Home Energy-Efficiency Rebate Program

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

Why Thermostats Matter

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

WITH OMRON E5CC CONTROL

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

INDUSTRIAL MICRODIFFUSION OIL BURNERS

FSTC Equipment Test Report

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

HEATING AND COOLING REBATES

HEATING AND COOLING REBATES

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.)

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

FINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

INFRARED RADIANT TUBE HEATER

Groen Vortex, Model VRC-6E Electric Steamer Performance Test

LABORATORY ILLUMINATED FLOTATION BATH

INTERNATIONAL STANDARD

VX SERIES Wireless Thermostat with Occupancy Sensor

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

RK-03 Hydrogen Detector Operator s Manual

Electric radiator tests

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

Environmental Monitoring SmartSlot Card

Isolated Thermocouple Module

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

INTERNATIONAL STANDARD

PG&E s Applied Technology Services Hot Water Technology Performance Laboratory

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

August 16, Advice No , Schedule 3 Residential Demand Response Water Heater Pilot Term Update

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

LUMINOUS A PATIO HEATER LIKE NO OTHER

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

HEATING AND COOLING REBATES

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Food Service Technology Center Promoting Energy Efficiency in Food Service

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Transcription:

Food Service Technology Center IR Energy Habanero HAB-M50 Gas Patio Heater Test Report Application of ASTM Standard Test Method FF2644-07 September 2014 Prepared by: Elan Frantz Trey Young Fisher-Nickel, Inc. Prepared for: Pacific Gas and Electric Company Customer Energy Efficiency Programs PO Box 770000 San Francisco, California 94177 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. 2014

FSTC Food Service Technology Center Background The information in this report is based on data generated at the Pacific Gas and Electric Company (PG&E) Food Service Technology Center (FSTC). Dedicated to the advancement of the foodservice industry, The FSTC has focused on the development of standard test methods for commercial foodservice equipment since 1987. The primary component of the FSTC is a 10,000 square-foot laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, equipment setup and storage areas, and a state-of-the-art demonstration and training facility. The FSTC Energy Efficiency for Foodservice Program is funded by California utility customers and administered by PG&E under the auspices of the California Public Utilities Commission (CPUC). California customers are not obligated to purchase any additional services offered by the contractor. Policy on the Use of Food Service Technology Center Test Results and Other Related Information Fisher-Nickel, Inc. and the FSTC do not endorse particular products or services from any specific manufacturer or service provider. The FSTC is strongly committed to testing foodservice equipment using the best available scientific techniques and instrumentation. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC. FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws. Disclaimer Copyright 2014 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. Reproduction or distribution of the whole or any part of the contents of this document without written permission of FSTC is prohibited. Results relate only to the item(s) tested. Neither, Fisher- Nickel, Inc., PG&E nor any of their employees, or the FSTC, make any warranty, expressed or implied, or assume any legal liability of responsibility for the accuracy, completeness, or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately-owned rights, including but not limited to, patents, trademarks, or copyrights. Reference to specific products or manufacturers is not an endorsement of that product or manufacturer by Fisher-Nickel, Inc., the FSTC, or PG&E. In no event will Fisher-Nickel, Inc. or PG&E be liable for any special, incidental, consequential, indirect, or similar damages, including but not limited to lost profits, lost market share, lost savings, lost data, increased cost of production, or any other damages arising out of the use of the data or the interpretation of the data presented in this report. Retention of this consulting firm by PG&E to develop this report does not constitute endorsement by PG&E for any work performed other than that specified in the scope of this project. Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (CPUC). It does not necessarily represent the views of the CPUC, its employees, or the State of California. The CPUC, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the CPUC nor has the CPUC passed upon the accuracy or adequacy of the information in this report. Revision History Revision num. Date Description Author(s) 0 September 2014 Initial Release E. Frantz / Trey Young Page 2 of 17 CP 140213

Contents Page Introduction... 5 Background... 5 Objectives... 6 Equipment Description... 6 Methods and Results... 7 Setup and Instrumentation... 7 Measured Energy Input Rate Test... 8 Preheat Test... 8 Temperature Distribution and Effective Heated Area... 9 Heating Index... 11 Conclusions... 11 Appendix A: Glossary of Terms... 12 Appendix B: Additions, Deviations, & Exclusions... 14 Appendix C: Equipment Specifications... 15 Addendum: Report Certification... 17 Page 3 of 17

Figures Page Figure 1: IR Energy Habanero HAB-M50 Heater... 6 Figure 2: Preheat Test... 9 Figure 3: Temperature distribution plot at high input rate... 10 Tables Page Table 1: Equipment Specifications... 6 Table 2: Test Instrumentation Inventory 7 Table 3: Input Rate Test Results... 8 Table 4: Preheat Test Results... 9 Page 4 of 17

Introduction Background Patio heaters are commonly used as a method of warming outdoor dining areas. A deck or patio can be operational earlier in the spring and later into the autumn by providing additional heat to an area that would otherwise be unpleasantly cold. A patio heater can also take the edge off a cool summer night to help keep customers comfortable and relaxed. Also known as radiant space heaters, the conceivable applications extend well beyond the realm of food service into nearly every situation requiring additional heat. There are countless outdoor, as well as indoor, uses for patio heaters when people or objects require warmth that is otherwise not available. While initial capital cost is a determining factor in the selection of a new patio heater, the appliance can also be evaluated with regards to long-term operational cost and performance, as characterized by preheat time, energy consumption, and effective heated area. The Food Service Technology Center developed a standard testing procedure to evaluate the performance of gas and electric patio heaters. This test procedure was designed to allow evaluation of patio heater performance and energy consumption in a structured laboratory setting. The primary objective of the test procedure is to determine the area under or near the heater where a person could reasonably expect to be comfortable. Relating a person s thermal comfort at specific locations under the heater can be challenging, since the environment is not uniform. Some surfaces are hot, while others may be cold when compared to the surface temperature of a person s body or clothing. Mean radiant temperature is a measure of the combined effect of these non-uniform hot and cold surfaces on a body (person) within the space. The test procedure uses mean radiant temperature to characterize the useful output from a radiant patio heater. The useful output is specified as the area under and around the heater having a mean radiant temperature rise of at least 3 F in a design environment of 60 F. While a 3 F temperature rise does not sound significant, it is referring to a rise in radiant temperature, which is more noticeable than a 3 F rise in ambient temperature. Stated another way, a heater producing a 3 F rise in mean radiant temperature in a 60 F environment would feel warmer than an environment with an ambient temperature of 63 F. Using the 63 F boundary not only determines the area where the heater is delivering the most useful heat, but also sets standard criteria for comparing different heaters. Page 5 of 17

Objectives The objective of this report is to examine the operation and performance of the Habanero HAB-M50 natural gas-powered heater under the controlled conditions of the ASTM Test Method F2644-07. The scope of this testing is as follows: 1. Energy input rate is determined to confirm that the patio heater is operating within 5% of the nameplate energy input rate. 2. Preheat time and energy consumption is determined. 3. The temperature distribution and effective heated area is determined with the heater operating at high input. 4. The heater s heating index is determined to relate the input rate to the effective heated area. Equipment Description The Habanero series of gas heaters offers an array of heating options with input rates ranging from 15,000 Btu/h to 50,000 Btu/h. The size of the infrared burners and input rate depends on the Habanero model. The Habanero series heaters may be wall, ceiling, or chain mounted to heat designated areas. In addition, the heater can be mounted at an angle. Figure 1: IR Energy Habanero HAB-M50 The HAB-M50 has a high fire rate of 50,000 Btu/h and a low fire rate of 42,000 Btu/h. The heater employs a ceramic infrared burner that radiates from the patio heater enclosure. The heater is ignited with an electronic spark ignition which can be controlled through a remote switch. Equipment specifications are listed in Table 1. Table 1: Equipment Specifications Test Work Order Number (TWO) 11227 Manufacturer IR Energy Inc. Model HAB-M50 Serial Number 137238 Generic Equipment Type Patio heater gas Rated Input 50,000 Btu/h (max), 42,000 Btu/h (min) Construction Steel Controls Ignition controls External Dimensions (W x D x H) 47.5 in. x 10.6 in. x 11.4 in. Custom Settings (if any) High/low input rate option Page 6 of 17

Methods and Results Setup and Instrumentation The Habanero HAB-M50 was installed in accordance to the manufacturer s instructions and Section 9 of the ASTM Test Method. The patio heater was mounted with the heating mesh located 8.0 feet above the ground at a zero degree angle. Gas consumption was monitored using a positive displacement meter, which generated a pulse for every 0.05 ft 3 of gas used. Heater temperature was monitored with a 24 gauge, type K, fiberglass insulated thermocouple wire. The mean radiant temperature can be determined at a specific point under the heater with a globe thermometer. A globe thermometer, shown in Figure 2, consists of a thermocouple junction located in the geometric center of a sphere. The thermocouple measures the average surface temperature of the sphere, and, when combined with the ambient air temperature and the convection heat transfer for the sphere, can be used to calculate the mean radiant temperature for that location. By using an array of globe thermometers, the entire area under the heater can be covered. After calculating the mean radiant temperature of the space both with and without the heater operating, the effect of the heater can be determined. Once the effect of the heater at a specific ambient temperature is known, its effect on a design environment having a different ambient temperature can be calculated. With a minimum temperature rise specified, a boundary is drawn and the heated area calculated. A grid of 60 globe thermometers with a spacing of 2 feet was used to measure the radiant heat from the heated, and four 24 gauge, type K, teflon insulated, aspirated thermocouples monitored the ambient temperature. The globe thermometers were positioned 36 inches off the floor to approximate the position of the center of a sitting person s chest. Figure 3 shows the globe thermometer grid. The gas meter and all thermocouples were connected to a computerized data acquisition system that recorded data every second. Table 2: Testing Equipment Inventory Description (ID) Manufacturer Model Measurement Resolution Calibration Next Calibration Range Date Gas Meter (ALD405) Sensus R-315 0 315 cu.ft./h 0.05 cu.ft. 11/27/2013 6/12/2016 Page 7 of 17

Measured Energy Input Rate Test The energy input rate was determined by turning the heater on and measuring the energy consumed for a period of 15 minutes. The energy used and the time elapsed were used to calculate the maximum energy input rate. The energy input rate on the high setting was measured at 50,100 Btu/h, within 0.2% of the nameplate rate of 50,000 Btu/h. This ensured the heater was operating as per the manufacturer s specification, and the testing could continue without adjustment. The Habanero consumed a negligible amount of electrical energy for the controls. Table 3: Input Rate Test Results Test Voltage (V) 24 Rated Energy Input Rate (Btu/h)* 50,000 Measured Energy Input Rate, High Setting (Btu/h) 50,100 Difference (%) 0.2 *Tests for the HAB-M50 were conducted in the high setting. Preheat Test The preheat test recorded the time and energy required for the heater to increase the reflector temperature from 75 ± 5 F to a temperature that equals 95% of the heater s maximum stabilized temperature (as measured by the thermocouple attached to the reflector). The test continued until the reflector temperature had stabilized to within ± 3 F over a period of 5 minutes. The point when the reflector temperature had reached 95% of its maximum temperature was then determined. The elapsed time and the energy consumed by the heater up until the point was reported as preheat time and energy. The preheat test indicated a maximum reflector temperature of 753.4 F, which meant the heater was considered preheated when the reflector reached 715.7 F (95% of maximum). The heater reached this temperature in 4.13 minutes, while consuming 3,575 Btu of energy. The preheat chart for the Habanero heater is shown in Figure 4. Page 8 of 17

Reflector Temperature ( F) 900 800 700 600 500 400 300 200 100 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Time (min) Figure 2: Preheat Test Table 4: Preheat Test Results Ambient Temperature ( F) 73.4 Maximum Reflector Temperature ( F) Preheated Reflector Temperature ( F) 753.4 715.7 Duration (min) 4.13 Preheat Energy Consumption (Btu) 3,575 Preheat Rate ( F/min) 155.3 Temperature Distribution and Effective Heated Area Temperature distribution and effective heated area tests are used to determine the specific boundary where the heater has raised the mean radiant temperature of the globe thermometers to 3 F above the design temperature of 60 F. With this information, the size and shape of the heat pattern can be determined and the heater s heating index can be calculated. To confirm that the test apparatus was in stable condition, the temperatures of the globe thermometers and the heat reflector were monitored for a period of 5 minutes before the heater was turned on. Each temperature was verified to be stable within ± 0.5 F during this period, indicating the test cell was not in a transitional state of heating or cooling down. The heater was then turned on and allowed to run for 15 minutes, after which time Page 9 of 17

the globe thermometer temperatures were recorded for 5 minutes. This test was performed in triplicate to ensure the accuracy of results. In order to generate the plots, each average globe thermometer temperature from the 5-minute test was first normalized to the design mean radiant temperature. To determine the exact location of distribution plot boundary, the linear interpolation procedure described in the ASTM Test Method is applied to the areas where one globe is above the threshold temperature and an adjacent globe is below it. The distribution plot for the high-input test on the Habanero heater is shown in Figure 5, which includes the 63 F temperature boundary specified by the test method, as well as additional boundaries indicating further temperature increments 1 F. 6 Side (ft.) 5 4 3 2 1 0-1 -2-3 -4-5 MRT* 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59-6 -6-5 -4-3 -2-1 0 1 2 3 4 5 6 Front (ft.) *MRT - Mean Radiant Temperature, normalized to a 60 F ambient. Figure 3: Temperature distribution plot at high input rate The effective heated area is the area contained within the boundary of the 63 F contour line shown in the temperature distribution plot. The heated area for the Habanero heater at high input was 128.0 ft 2 ± 6.1 ft 2. Page 10 of 17

Heating Index The heating index relates the effective heated area to how much energy is consumed by the patio heater in one hour. It is calculated by dividing the effective heated area by the patio heater input rate. The heating index for the Habanero heater was 2.56 ft 2 /kbtu/h for the HAB-M50 heater. Conclusions The IR Energy HAB-M50 heater produced a round-shaped temperature distribution with an effective heated area of 128.0 ft 2 ± 6.1 ft 2. The effective heated area represents the part of the test cell raised to at least 3 F above the ambient design environment. The HAB-M50 generated a 73 F maximum mean radiant temperature in the center of the heat pattern. Page 11 of 17

Appendix A: Glossary of Terms Design Environment Unheated environment for which test unit s performance is to be evaluated. The design environment is specified as having a mean radiant temperature of 60 F. Effective Heated Area (ft 2 ) The amount of square footage under a patio heater that can be warmed to a specified temperature (3 F above the design environment). Energy Input Rate (kw or kbtu/h) Energy Consumption Rate Energy Rate The peak rate at which an appliance will consume energy, typically reflected during preheat. Heating Index (ft 2 /kw) The quotient of the measured energy input rate and the effective heated area. Heating Value (Btu/ft 3 ) Heating Content The quantity of heat (energy) generated by the combustion of fuel. For natural gas, this quantity varies depending on the constituents of the gas. Measured Input Rate (kw or Btu/h) Measured Energy Input Rate Measured Peak Energy Input Rate The maximum or peak rate at which an appliance consumes energy, typically reflected during the preheat period (i.e., the period of operation when the burners or element are energized). Mean Radiant Temperature ( F) The uniform surface temperature of an imaginary black enclosure in which an occupant would exchange the same amount of radiant heat as in the actual non-uniform space. Rated Energy Input Rate (kw, W or Btu/h, Btu/h) Input Rating (ANSI definition) Nameplate Energy Input Rate Rated Input The maximum or peak rate at which an appliance consumes energy as rated by the manufacturer and specified on the nameplate. Pilot Energy Rate (kbtu/h) Pilot Energy Consumption Rate The rate of energy consumption by the standing or constant pilot while the appliance is not being operated (i.e., when the thermostat(s) or control knob(s) have been turned off by the operator). Preheat Energy (kwh or Btu) Preheat Energy Consumption The total amount of energy consumed by an appliance during the preheat time. Preheat Time (min) Preheat Period The time required for an appliance to preheat from the ambient room temperature (75 ± 5 F) to a specified (and calibrated) operating temperature or thermostat set point. Page 12 of 17

Test Method A definitive procedure for the identification, measurement, and evaluation of one or more qualities, characteristics, or properties of a material, product, system, or service that produces a test result. Page 13 of 17

Appendix B: Additions, Deviations, & Exclusions Additions: None. Deviations: None. Exclusions: None. Page 14 of 17

Appendix B: Manufacturer s Specifications Page 15 of 17

Page 16 of 17

Page 17 of 17