Gas Safety-Landlords Responsibilities

Similar documents
Your guide to gas safety

Gas appliances. Keeping them safe

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

Protecting your home. For information on Gas Safe registered engineers in your area please visit or call

Carbon Monoxide Safety

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Carbon monoxide Knowing more

The Gas Safety (Installations and Use) Regulations 1998.

Gas Safety. Information for homeowners. orbit.org.uk

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

DOMESTIC SMOKE. working for a cleaner, quieter, healthier world

COMPLIANCE WITH SAFETY

Gas safety. Information for homeowners. orbit.org.uk

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

ADVICE NOTE GAS SAFETY. How you can stay gas safe in your flat

THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1998

Carbon Monoxide Awareness Badge Pack

CO detection on boats

Professional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D

Protecting Children from Carbon Monoxide Poisoning

Professional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D

Carbon Monoxide Room Alarm Installation and User Guide Part No:

carbon monoxide Preventing carbon monoxide poisoning in your home

Special Edition. Routt County Office of Emergency Management. Carbon Monoxide The Silent Killer. What is Carbon Monoxide (CO)?

Carbon Monoxide Detectors. What is carbon monoxide?

carbon monoxide alarms

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

The management of shared facility HMOs

HOME FIRE SAFETY. Reference Guide

putting safety first natural gas

Guide to the Cub Scout Home Safety Badge

Welsh Government Consultation: Renting Homes (Wales) Act 2016 Fitness for Human Habitation Response from ARLA Propertymark January 2018 Background

Consultation on Fire and Smoke Alarms in Scottish Homes

4.2kW GAS CABINET HEATER OPERATING INSTRUCTIONS. For Model: TWGC100

Model Carbon Monoxide (CO) Alarm Response Policy

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

We are committed to your safety and we take our responsibilities on solid fuel safety very seriously. We will carry out a full annual safety check.

Carbon Monoxide Safety Information

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

OFTEC s role in promoting safe domestic oil storage

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

Preventing deaths and injuries in the home in Scotland

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Manifesto for the 2017 General Election: Preventing deaths and injuries in the home

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Housing Division Notice

CARBON MONOXIDE (CO)

Travis County Emergency Services District #1 Standard Operating Guidelines

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Installation and User Guide

CARBON MONOXIDE DETECTOR, i4h-co-m330

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM

Title: Room-sealed fanned draught flue systems concealed within voids

The Gas Industry Unsafe Situations Procedure

Ways we can help. Making your energy easy

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

CO-808S User Manual. Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack

ABOUT NATIONAL ENERGY ACTION

Office of the Fire Commissioner

EDA Scottish Section Regional Business Forum

Safety Alert New Gas Regulation 2013

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

FUEL TYPE relating to UK deaths from unintentional carbon monoxide poisoning from to

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

Electrical Safety Policy

Manhattan Fire Protection District

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

HHIC consumer guide to gas boiler servicing

Technician s guide to best practice FINAL Draft v October Flues, chimneys and combustion air ventilators.

Formerly TB001. Gas industry unsafe situations procedure. IGEM/G/11 with amendments 11 th April 2018 Communication 1822

CO-9X User Manual 6 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

We are committed to your safety and we take our responsibilities on solid fuel safety very seriously. We will carry out a full annual service.

7 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

morsø PANTHER GAS STOVE

Building Regulations Update. by Eamonn Smyth

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

Fire risk management plan. MH/05/Revised/06/17

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

LANDLORD S GUIDE. The Landlord s Guide to the Gas Safety Regulations Electrical Equipment (Safety) Regulations Who must comply?

The Village of Franklin Gas Safety Pamphlet

Screen for carbon monoxide poisoning instantly to help safeguard your staff with the ToxCO range

Carbon Monoxide Poisoning

Home CALOR. At with INTRODUCING OUR NEW TUMBLE DRYER SAFETY AT HOME

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

FUEL type relating to UK Deaths from unintentional carbon monoxide poisoning from to

Model BR660VA Heat Engine

Fire risk your responsibility?

Millfield Schools Fire Risk Prevention Policy

CARBON MONOXIDE POISONING: ONGOING VIGILANCE TO ENSURE RECOGNITION AND PREVENTION

NOTTINGHAM CITY HOMES

Property Health and Safety Compliance at Housing and Education Centres

Transcription:

Gas Safety-Landlords Responsibilities Chris Bielby/Grant Taylor - SGN November 2014

The aim of today s session Raise awareness on: Your regulatory responsibilities as a Landlord The dangers of the Silent Killer Carbon Monoxide What you can do to look after your tenants safety SGN s commitments 2

Who or what is a landlord? The Gas Safety (Installation and Use) Regulations 1998 defines a Landlord as: In England and Wales Where the relevant premises are occupied under a lease, the person. For the time being entitled to the reversion expectant on that lease or who, apart from any statutory tenancy, would be entitled to possession of the premises. Where the relevant premises are occupied under a licence, the licensor, save that where the licensor is himself a tenant in respect of those premises, it means the person referred to in the first bullet point. In Scotland, the person for the time being entitled to the landlord's interest under a lease lease means: A lease for a term of less than 7 years. A tenancy for a periodic term. Any statutory tenancy arising out of a lease or tenancy referred to in sub bullets above. 3

Who or what is a landlord? So this applies to a wide range of accommodations which are rented or let out including: Residential properties provided for rent by: Local authorities Housing Associations Private Sector Landlords Housing co-operatives Hostels Rooms Let in: Bed sit accommodation Private house holds Bed and Breakfast accommodation Hotels Rented holiday accommodation such as: Chalets Cottages Flats Caravans Narrow boats on inland waterways 4

Landlord regulatory responsibilities GS(I&U)R Annual Gas Safety Check of all gas appliances owned by the Landlord, i.e. intervals of not more than 12 months since previous check by a competent person. Recommended gas tightness test & visual examination of gas installation (can be carried out the same time as the annual gas safety check). Provide your tenant with a copy of a Gas Safety Record (CP12). This must be within 28 days of the check or for new tenants before they move in, alternatively for short lets, a copy of the Landlord s Gas Safety Record may be prominently displayed within the premises e.g. holiday homes. You must retain your copy of the Gas Safety record for a minimum of two years. Maintain appliance(s) in a safe condition and are suitably located (TB055). Carry out recommended remedial work as necessary. 5

Landlord regulatory responsibilities GS(I&U)R Why were these Regulations put in place? To safeguard tenants from suffering due to faulty and poorly maintained gas appliances. Provide Landlords with guidance on how to comply with relevant legislation. 6

How do I know my gas engineer is competent? All gas installation businesses, including self-employed gas installers, are required to be in membership of a 'class of persons' approved by the Health and Safety Executive (HSE). Currently the only body with such approval is the Gas Safe Register. Engineers carrying out work of gas appliances and associated pipework should be registered with Gas Safe Register and have the appropriate qualifications and experience to carry out the work. How can your tenant check this? All Gas Safe Registered engineers are issued with an ID card which you and/or your tenants should check. Check the front of the card for: The photo The start and expiry date The licence number The security hologram Check the back of the card to make sure: Your engineer is qualified to carryout the work you want done e.g. fires, boilers, warm air and that their qualifications are in date. You can also check that your engineer is Gas Safe registered by calling the Gas Safe Register on 0800 408 5500 or by visiting www.gassaferegister.co.uk. 7

Reminder of Regulation 30 Regulation 30 of the Gas Safety (Installation & Use) Regulations require gas fires, other gas space heaters or water heaters above 14 kw (gross) input, located in a room used for sleeping accommodation, must be room sealed. So what about rooms being used temporarily as sleeping accommodation, e.g. by the elderly/disabled? A recent Technical Bulletin (TB055) issued by Gas Safe Register has declared that Legislation does not make any allowance for temporary use. As such, as a Landlord you have a duty of care under section 3 of the HSWA to take reasonable practicable steps to ensure the safety of your tenants and therefore may consider the following action: Replace or remove the offending appliance Relocate the tenant to a more suitable accommodation 8

Carbon Monoxide (CO) the silent killer Carbon monoxide is a highly poisonous gas that has no taste, smell or colour and is produced by the incomplete burning of natural gas, Liquid Petroleum Gas (LPG) solid fuels such as coal, wood and oil due to the lack of a sufficient clean air supply. 9

Carbon Monoxide (CO) the silent killer Carbon Monoxide is a MIMIC it s notorious for simulating other more common conditions. Acute exposure can be mistaken for flu-like symptoms, viral infections, food poisoning or even just tiredness. Other things to take into consideration are: Do the symptoms only occur when you are at the property? Do you feel better when you are out of the property? Is anyone in the property suffering from the same symptoms (including pets)? Did everyone get the symptoms at the same time? If you are in any doubt have your gas appliances checked. 10

Symptomatic effects of CO 11

Symptoms & behaviour of CO Volume CO Time Saturation of haemoglobin Symptoms 0.01% - 100ppm 0.03% - 300ppm 1.5 hours 4% No symptoms Indefinite 15% Tightness across forehead, yawning 1.5 hours 10% No symptoms 4-5 hours 20% Headache, slight dizziness, breathlessness 0.05% - 500ppm 1.5 hours +20% 4-5 hours 40% Headache, dizziness, breathless palpitations on exertion Palpitations on exertion, weak knees, impaired judgement, possible collapse 0.40% <30 mins 60% Coma, weakened heart and respiration 12

Total Number of CO accidental deaths by Fuel by Year 1996-2012 13

Natural Gas - CO fatalities 1971-2008 14

Risk of incident in an occupancy category divided by the risk of an incident not in the category Risk of a CO incident occupancy type 6 5 Social sector landlord Privately rented Owner-occupied 4 3 2 1 0 96-97 97-98 98-99 99-00 00-01 01-02 02-03 03-04 04-05 05-06 06-07 07-08 08-09 09-10 10-11 11-12 Reporting year 1st July to 30th June 15

Prime causes of incidents Incidents occur due to one or a combination of the following factors. Lack of, or poor maintenance Poor flue/chimney installations, including blockages Combination of poor flues and adverse weather conditions Lack of ventilation Competence of the installation/ servicing engineer 16

Look for the signs Staining on appliance casing Staining on surrounding walls/decoration Yellow floppy flames Soot Deposits Excess condensation in a room when an appliance is in operation General poor condition of appliances Open flue and flueless appliances in sleeping accommodation 17

Look for the signs 18

Look for the signs 19

Look for the signs 20

Actions required if you suspect CO If you are at a property and identify or suspect there are any issues with the appliances and/or you are made aware of an issue. Carry out or advise the person present to: Turn off the gas at the meter, tank or cylinders Ventilate the premise Contact Gas Emergency Service (0800 111 999) or Gas Supplier in the case of LPG Have the gas appliances checked by a Gas Safe Registered Engineer If solid fuel or oil make contact with the relevant body HETAS for solid fuel or OFTEC for oil 21

What else can you do to protect your tenants? Install an audible Carbon Monoxide Alarm which complies with EN 50291. It should also have the British Standards' Kitemark or another European approval organisation's mark on it. 22

Installation and maintenance of your CO alarm Install the alarm to the manufacturers installation instruction and carry out any maintenance on the unit as described by the manufacturer. This will include: Keep the alarm free of dust Test regularly as detail in instructions Never use cleaning solutions on your alarm. Simply wipe with a slightly damp cloth. Do not paint the alarm. Do not spray aerosols on or near the alarm. Do not use any solvent based products near the alarm. Remember look after your CO Alarm and it will look after your tenants. 23

SGN s response to CO related calls In 2013 SGN attended 14,633 reports of a CO detector alarming 6757 in Scotland and 7876 in Southern England SGN operatives have Personal Atmosphere Monitors which activate when CO is present Reports or actual escapes of CO are responded to and made safe at no charge by the relevant Gas Transporter / Emergency Service Provider responsible for the network (Scotia Gas Networks in Scotland). Under the GT/ESP's respective license conditions, the arrangement of work other than making safe is the responsibility of the consumer and/or their gas supplier. 24

SGN s commitments to CO safety Our purpose is to keep our customers warm and secure by delivering gas safely, reliably and efficiently. We want to be the best in everything we do, so we aspire to eradicate natural gas related carbon monoxide poisoning and do all we can to raise awareness of this silent killer. This is why we never limit our work to our network areas, and always share our learning at national and international level. We are committed to: International level - maintaining our position as the exemplary GDN and protect UK holiday makers abroad as there has been an alarming increase in the CO fatalities linked with barbecues, tents and campervans. We will strive to make the most of every opportunity to share our learning and best practice examples with the European Member States. 25

SGN s commitments to CO safety cont d National level - leading at national committee and industry level, and champion collaboration with other GDNs and key stakeholder groups. A significant achievement to date has been the amendment to the Energy Bill which would require residential landlords to install CO alarms and MOT style safety gas and electric checks at change of ownership. Supporting Gas Safe in their on going campaigns. Local level - identifying opportunities to interact with our stakeholders and customers to raise awareness and understanding of the dangers of CO in order to achieve sustainable reductions in CO related incidents. 26

SGN Stakeholder engagement As part of our commitments to increasing wider awareness of the dangers of CO SGN have engaged with external stakeholders and the wider community Educating school children, youth groups and OAPS at The Risk Factory, Edinburgh Delivering safety messages to Tayside schoolchildren at Safe Taysiders Partnerships with other organisations such as Hazard Alley in Milton Keynes and Streetwise in Poole Continued partnership with Girl guiding and developed a resource for learners as part of the Active Response Badge and on line game for Brownies Utilising Face book and Twitter for customer awareness and feedback 27

Any questions? 28

Thank you. 29