Installation Instructions

Similar documents
Installation and Maintenance Instructions

Models: FM FM WARNING

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Installation WARNING SXWS9561. Stainless Steel Panel Shower

Installation Instructions

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation & Operation Manual

Installation & Operation Manual

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation & Operation Manual

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Installation Instructions / Warranty. PuraVida 15775XX1

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation Instructions / Warranty

Installation Instructions

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

EMERGENCY DRENCH SHOWER

Version: 1.1 INSTALLATION GUIDE WATERFALL SHOWER SYSTEM

Installation Instructions / Warranty

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Installation & Operation Manual

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation Instructions / Warranty. Metris 31060XX XX XX1

Installation Instructions / Warranty

Gas Connector Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve

CINCINNATI, OH USA

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

Installation Instructions / Warranty

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation Instructions / Warranty

Installation S

e Bath Fan with Light User s Guide

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

Sound Cover [ , , , ]

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

Installation. S Series Navigator Thermostatic Mixing Valve

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Wax Base Heater & Dispenser

Installation Instructions / Warranty

e Bath Fan with Light User s Guide

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Flipside Handshower and Showerhead Installation and User Guide

Installation S

e Heater/Exhaust Fan/Light User s Guide

Installation Instructions

Instruction Manual. Cheese Warmer with Pump

Installation Instructions / Warranty

Model 8356WCC Pull-Down Shower Eye/Face Wash

COVER PLATE GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTALLATION INSTRUCTIONS. York Column Ensemble Part #: 1724 IMPORTANT

Installation Instruction

Installation Instructions / Warranty

Operating Instructions & Parts Manual Models 99533, 99532

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

e Bath Fan with Light User s Guide

Owner s. 18 Misting MF18W. To view

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Karbon Kitchen Sink Tap

Installation S

Installation S

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation & Operation Manual for WarmlyYours Riviera Towel Warmers

Installation Instructions / Warranty. Massaud

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Atomizing Humidifier. Trion

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Installation Instructions / Warranty. Starck 10111XX XX XX1

55-Gallon Dispenser Package

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model H1011.8/H1011.8HPS Water Cooler

01550-RevG IMPORTANT INSTRUCTIONS WEBSITE MANUAL

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial:

COMBUSTION AIR SYSTEM

Installation S

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Installation Instructions

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

24 & 30 Quiet Design Oscillating Wall Mount Fan

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Transcription:

Installation Instructions Table of Contents Pre-Installation Information................2 Type A Column Shower Installation..........3 Supplies from Below/Vent Off Line Type B Column Shower Installation.........4 Supplies from Above/Vent Through Column Type H Column Shower Installation.........5 Supplies from Below/Vent Through Column Type O Column Shower Installation.........6 Supplies from Above/Vent Off Line Type O Column Shower w/receptors........7 Supplies from Above/Vent Off Line w/receptors Optional Shroud Installation..............8-9 IMPORTANT Before beginning installation, all supply, drain and waste piping to the shower must be completed according to the rough-ins received with the drain assembly. Check local codes and ordinances in your area for proper location and connection requirements. Conformity to local codes is the responsibility of the installer. This installation manual should be filed by the owner s maintenance department. 215-492; Rev. K; EN 03-310 2003 Bradley Corporation Page 1 of 9 12-16-2003 P.O. Box 309, Menomonee Falls, WI 53052-0309 Phone: 1-800-BRADLEY FAX: (262) 251-5817 http://www.bradleycorp.com

Installation Instructions Pre-Installation Information Components Material: Column showers are constructed of stainless steel. Exterior brass components are polished and chrome-plated. Supply Inlets: The supply inlets are 3/4" type L copper tube. Supplies required for installation: Supply piping to column s 3/4" type L copper tubing 2" NPT vent pipe (for type B and type H drains only) (5) 5/16" screws (for shroud slip ring installation) Care and Cleaning of Stainless Steel IMPORTANT: Never use ordinary steel wool or steel brushes on stainless steel. Always use stainless steel wool or stainless steel brushes. Do not allow any salty solutions to evaporate and dry on stainless steel. General cleaning: Ordinary deposits of dirt and grease are quickly removed with soap and water. Whenever possible, the metal should be thoroughly rinsed and dried after washing. To get rid of tightly adhering deposits, use stainless steel polishing powder. In all cases, rubbing should be in the direction of polishing lines. Showerhead cleaning: If the showerhead delivers an uneven spray, remove the showerhead from the unit, disassemble, and remove foreign matter. Then reassemble showerhead and reinstall into unit. Rust: Sometimes the appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the source of the rust in some iron or steel not actually a part of the stainless steel structure. NOTE: Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear. The use of these cleaners should be avoided. Bradley Column Shower Warranty Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in material and workmanship under normal use and service upon the following terms and conditions: 1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within the limitations of this warranty. 2. The period during which Column Shower components are warranted is one (1) year, measured from the date of our invoice. 3. This warranty does not cover installation or any other labor charges and does not apply to any units which have been damaged by accident, abuse, improper installation or improper maintenance. 4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation shall not otherwise be liable under any circumstances for incidental, consequential or indirect damages caused by defects in the repair or replacement thereof. 5. This warranty extends only to commercial and institutional purchasers and does not extend to any others, including consumer customers of commercial and institutional purchasers. 6. this warranty is in lieu of all other warranties, express or implied, including any implied warranty of merchantability or fitness for a particular purpose or otherwise. 2 12-16-2003

Installation Instructions Installation Instructions for Type A Column Shower Step 1a: Install column shower components 1. Remove the five bolts that secure the disposable washer to the drain and lift the disposable washer off. 2. Bolt the column shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1a). Step 2a: Connect water supply 1. Remove the two 1/4"-20 screws from the access panel on the lower body of the column shower and lift the panel off. 2. Through the access opening, connect the water supplies to the shower s 3/4" copper tubing as shown in Figure 2a (piping supplied by installer). 3. Turn water to the shower on and test for leaks and adequate water flow. Figure 1a 4. Replace the access panel onto the shower with the 1/4"-20 screws provided. NOTE: For column shower drains with a dome grate, install the two halves of the grate with the screws provided after the column installation is complete. (5) 5/16"-18 HEX-HEAD BOLTS 160-092 (5) WASHERS 142-034 3/4" COPPER TUBING SOLDER JOINT UNION ELBOW DRAIN TYPE A DRAIN DOTTED LINES = PIPING SUPPLIED BY INSTALLER Figure 2a 12-16-2003 3

Installation Instructions Installation Instructions for Type B Column Shower Step 1b: Install column shower components 1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off. 2. Loosen the screw(s) securing the shower s cover and lift the cover off. DO NOT remove the screws! 3. Insert a 2" NPT vent pipe (supplied by installer) into the shower. NOTE: Make sure that the vent pipe does not snag internal wiring or come in contact with the electronic components. 4. Position the shower over the drain and screw the 2" NPT vent pipe into the vent connection (see Figure 2b). 5. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1b). Step 2b: Connect water supply 1. Drop the supplies to the top of the column shower. 2. Slide the column cover up the vent and supply piping. Figure 1b NOTE: If you are installing a column shroud, slide the slip ring (and shroud if over 48" long) up the vent and supply piping first, and then slide the column cover up (see page 8 for shroud installation). 3. Make the supply connections. The supply connection must be made inside the top of the shower so that there is no interference with the piping and the column cover. 4. Turn water to the shower on and test for leaks and adequate water flow. 5. Secure the column cover with the screws provided. NOTE: For column shower drains with a dome grate, install the two halves of the grate with the screws provided after the column installation is complete. (5) 5/16"-18 HEX-HEAD BOLTS 160-092 (5) WASHERS 142-034 VENT CONNECTION 2 NPT VENT PIPE DRAIN TYPE B DRAIN DOTTED LINES = PIPING SUPPLIED BY INSTALLER Figure 2b 4 12-16-2003

Installation Instructions Installation Instructions for Type H Column Shower Step 1c: Install column shower components 1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off. 2. Loosen the screw(s) securing the shower s cover and lift the cover off. DO NOT remove the screws! 3. Insert a 2" NPT vent pipe (supplied by installer) into the shower. NOTE: Make sure that the vent pipe does not snag internal wiring or come in contact with the electronic components. 4. Position the shower over the drain and screw the 2" NPT vent pipe into the vent connection (see Figure 2c). 5. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1c). Step 2c: Connect water supply 1. Remove the two 1/4"-20 screws from the access panel on the lower body of the column shower and lift the panel off. Figure 1c 2. Through the access opening, connect the water supplies to the shower s 3/4" copper tubing as shown in Figure 2c (piping supplied by installer). 3. Slide the column cover over the vent. (5) 5/16"-18 HEX-HEAD BOLTS 160-092 (5) WASHERS 142-034 NOTE: If you are installing a column shroud, slide the slip ring (and shroud if over 48" long) up the vent and supply piping first, and then slide the column cover up (see page 8 for shroud installation). 4. Turn water to the shower on and test for leaks and adequate water flow. 5. Replace the access panel onto the shower with the 1/4"-20 screws provided. NOTE: For column shower drains with a dome grate, install the two halves of the grate with the screws provided after the column installation is complete. VENT CONNECTION 2" NPT VENT PIPE SUPPLY PIPING TYPE H DRAIN DOTTED LINES = PIPING SUPPLIED BY INSTALLER Figure 2c 12-16-2003 5

Installation Instructions Installation Instructions for Type O Column Shower Step 1d: Install column shower components 1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off. 2. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1d). 3. Loosen the screw(s) securing the shower s cover and lift the cover off. DO NOT remove the screw(s)! Step 2d: Connect water supply 1. Drop the supplies to the top of the column shower. 2. Slide the column cover up the vent and supply piping. NOTE: If you are installing a column shroud, slide the slip ring (and shroud if over 48" long) up the vent and supply piping first, and then slide the column cover up (see page 8 for shroud installation). Figure 1d (5) 5/16"-18 HEX-HEAD BOLTS 160-092 (5) WASHERS 142-034 3. Make the supply connections. The supply connection must be made inside the top of the shower so that there is no interference with the piping and the column cover. 4. Turn water to the shower on and test for leaks and adequate water flow. 5. Secure the column cover with the screws provided. NOTE: For column shower drains with a dome grate, install the two halves of the grate with the screws provided after the column installation is complete. DRAIN TYPE O DRAIN Figure 2d 6 12-16-2003

Installation Instructions Installation Instructions for Type O Column Shower Step 1e: Install column shower components 1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off. 2. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 2e). 3. Loosen the screw(s) securing the shower s cover and lift the cover off. DO NOT remove the screw(s)! Step 2e: Connect water supply 1. Drop the supplies to the top of the column shower. 2. Slide the column cover up the vent and supply piping. NOTE: If you are installing a column shroud, slide the slip ring (and shroud if over 48" long) up the vent and supply piping first, and then slide the column cover up (see page 8 for shroud installation). 3. Make the supply connections. The supply connection must be made inside the top of the shower so that there is no interference with the piping and the column cover. 4. Turn water to the shower on and test for leaks and adequate water flow. 5. Secure the column cover with the screw(s) provided. 6. Install receptors and partitions following the installation instructions designated for and provided with the receptors. RECEPTOR BOLTS AND WASHERS DRAIN TYPE O DRAIN WITH RECEPTORS Figure 2e 12-16-2003 7

Installation Instructions Installation Instructions for Optional Column Shower Shroud NOTE: The column shower must be installed before the shroud. The shroud clips and knock-outs in the column cover must also be prepared. Before making the supply connections, slide the shroud slip ring up the vent and supply piping. IMPORTANT: If the shroud is longer than 48" (it has a welded seam rather than a snap together hem) it must also be slid up the vent and supply piping. If the supply connections are completed prior to the shroud installation, the supplies will have to be disconnected in order to slide the slip ring (and shroud if over 48" long) over the vent and piping. Step 3: Preparing the Column Cover 1. Remove the column cover from the top of the shower by loosening the screw(s) that secures the column cover retainer. 2. Carefully remove the necessary knock-outs from the cover (see Figure 10). 3. Insert the three shroud clips into the locations shown in Figure 10. Snap the clips in place using a flat blade screwdriver. 4. Reassemble the cover on shower and proceed with remainder of installation. Step 4: Complete the Installation 1. Make sure the slip ring (and shroud if required) is in place over the vent and supply piping. 2. Fasten the slip ring to the ceiling with five 5/16" diameter screws (supplied by installer) (see Figure 9 for screw location dimensions). 3. Bring the shroud seam around the vent and supply piping and slide the shroud together (0-48" long shrouds only). Fasten hem together using the supplied #6-32 screws. 4. With the column cover in place and the supply connections made, lower the shroud and fasten to the column cover with the #10-24 screws provided (see Figures 8 and 10). SLIP RING S57-020A (12" LONG) S57-141 (7" LONG) (SLIDES INSIDE SHROUD - FASTEN TO CEILING WITH 5/16" SCREWS SUPPLIED BY INSTALLER) BOTTOM OF SLIP RING SHROUD (0-48" LENGTHS HAVE HEMMED EDGE) (54"-72" LENGTHS HAVE WELDED SEAM) SCREW 160-400 Figure 8 8 12-16-2003

Installation Instructions Installation Instructions...continued (5) 3/8" DIA. EQUALLY SPACED HOLES 7-3/8" DIA BOLT CIRCLE 6-3/8" DIA Figure 9 Slip Ring Bolt Pattern #10-24 x 1/2" SCREW 160-245 (QTY. 3) KNOCK-OUTS SHROUD CLIP 159-413 (QTY. 3) KNOCK-OUT #10-24 x 3/4" SCREW 160-142 COVER 107-062A - 2-5 PERSON 107-074A - 6 PERSON 107-529 - 6 PERSON WITH THERMOBLENDER 107-530 - 2-5 PERSON WITH THERMOBLENDER RETAINER- COVER 132-049 Figure 10 12-16-2003 9