SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Similar documents
KANE-ALERT-CO 2 Monitor with Temperature

LS1. Operator Manual. Kane International Ltd

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

CD100A COMBUSTIBLE GAS DETECTOR

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

VALTRONICS IAQ Monitor

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Manual Vane Anemometer PCE-VA 20

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Single Gas Monitor 777

USER MANUAL Digital CO Monitor Model CO30

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

SENSIT HXG-2d Combustible Gas Detector

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

USER GUIDE Heat Index Psychrometer

Digital Salt / TDS Meter. 390a. The Value Leader TM

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

RK-05 Carbon Monoxide Detector Operator s Manual

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

RAM GENE / RAM GENE-1

HIn3550 Magnetic Field Monitor User's Manual

UNI 321. User s Guide

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

RK-02 Multi Point Detector Operator s Manual

Counting Scales. HC-i Series.

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

CO2 & Oxygen Monitor Operating Instructions Model: RAD

IMR IX176 Portable Gas Detector User Manual

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Model ST-128M Moisture Detector

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

ExplorIR -W CO2 Sensor

Combustible Gas Leak Detector Instruction Manual

PL400 Patient Lift Scale Indicator Owner s Manual

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Programmable Towel Radiator Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

IPhone: 219/

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Issue 4 10/10/11. Part Number: 48160

CO warning instruments and gas spillage detectors

BX444-Mc Gas Detector

Model: RT310. Installation Manual

Universal Clamp Meter

User's Guide. CO 2 Monitor. Model CO200

CO2 Monitor Operating Instructions

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

E1000 Portable gas detector

Pasto Sous vide water bath

GasAlertMicroClip X3 Specifications

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

GMH 285 / GMH 285-BNC

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

169MHz Telecare Devices Gas & Carbon Monoxide Detector

ir-range 8G /03.15 Changes reserved.

Datasheet. CozIR -A CO2 Sensor. Tel: +44 (0)

Digital Wall Clock LED. Model Number: MWC01 READ AND SAVE THESE INSTRUCTIONS

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

GS100M Gas Detection Controller

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

RK/ RK Carbon Monoxide Detector Operator s Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

SprintIR -W CO2 Sensor

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Technical Specifications and User Guide for the GDCO Detector

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

IMR EX610. Portable Gas Detector. Operation Manual

Air Purifier Test Report (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001

Dräger Pac 7000 Single-Gas Detection Device

Dräger Pac 5500 Single-Gas Detection Device

Oxygen Monitor Operating Manual

RK Carbon Monoxide Transmitter Operator s Manual

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

User Manual. GPD 3000 e. gas detector

AlcoBlow. User Handbook

PGM100 Carbon Monoxide

ExplorIR -M CO2 Sensor

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Transcription:

SGA71 Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel: +44 (0) 1707-375550 Fax: +44 (0) 1707-393277 E-mail: sales@kane.co.uk Stock No: 17657-3 September 2002 Kane International Ltd

INSTRUCTIONS SGA71 WARNING This instrument should only be used by trained and competent persons, after due consideration of any risks involved. Carbon Monoxide is life threatening even at relatively low concentrations be sure you understand the risks before investigating potential leaks.

INSTRUCTIONS FOR USE ON/OFF The SGA71 is operated by a single button for ON and for OFF. When the unit is switched on (only switch on where you are sure the air is fresh) it automatically self zeros in 50 seconds. During countdown the display shows time remaining as two digits. Turn ON Countdown 39 When the countdown reaches 00 the meter will set its sensor to zero and display CO concentration as three digits Normal display CO ppm 000 Hold down the ON/OFF key for 2 seconds and release to switch the meter OFF, the display will show a single digit and count down for 9 seconds. Turn OFF Countdown 9 If turned off accidentally, press the button again and hold for 2 seconds and release to cancel.

MAX button Maximum value Display MAX 039 Press MAX to display the highest reading detected while the meter is switched ON. HOLD button Holds value when button pressed 025 HOLD Freezes the display with the CO reading at the time the HOLD button. VISUAL INDICATOR This is the LED located at the top of the meter. At different CO concentrations the LED changes colour to give visual warning: OFF: GREEN: YELLOW: RED: 0-1 ppm 2-9 ppm 10-34 ppm 35 ppm or higher

AUDIBLE ALARM The instrument is pre-set with an alarm at 35 ppm, if this level is exceeded an audible tick will sound. The tick rate will increase with higher concentrations, check the LCD display for actual level. While the alarm is sounding the unit can not be turned off until the level has dropped below 35 ppm. BACK-LIGHT To activate the back-light press the ON/OFF key quickly once. Do not hold down the key or the unit will switch off. To turn off the back-light press quickly again. Note using the back-light decreases battery life. BATTERY INDICATION Low battery indication BAT 039 If the battery falls below a pre-set level the symbol BAT appears in the display. Do not use the instrument when this symbol is present. Replace the battery immediately.

TROUBLESHOOTING If the display fails to stabilise at around zero within a few minutes this may indicate a defective sensor or a sensor that has been exposed to excessive levels of CO. If the symptom persists seek advice from Kane International Ltd. Always check for correct operation before use. Use a known source of CO (e.g. a lighted cigarette or a gas flame) taking care to act in a safe manner and not to expose the SGA71 sensor at too high a temperature. If the unit does not change as expected, return to Kane International Ltd for investigation. If during use you detect CO leaks be sure you know the appropriate actions to take to protect yourself and others. Before switching off the instrument always expose it to fresh air until the reading falls below 5 ppm. Note that the reading falls much more slowly than it rises so you may need to wait two or three minutes.

SGA71 SPECIFICATION Range: Resolution: Accuracy: Audible alarm: Visual indication: Battery: Operating temp: 0-999 ppm 1 ppm +/- 3% of reading +/- 5 ppm < 100 ppm Preset at 35 ppm LCD and LED 9V PP3 Alkaline 0 40 o C No user serviceable parts. Re-calibrate every 12 months. Check for correct operation before every use.

ELECTROMAGNETIC COMPATIBILITY This product has been tested for compliance with the following generic standards: EN 50081-1 EN 50082-1 and is certified to be compliant Specification EC/EMC/KI/SGA71 details the specific test configuration, performance and conditions of use.