Models Series Series

Similar documents
Models Series Series

Model Series Series

PumpAgents.com - Click here for Pricing/Ordering PAR MAX3 Models Series 3.4GPM/12.8LPM

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Automatic Water System Pump SERIES

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

LC Series - Light Commercial Pump Station Installation and Operation Manual

The sealless FLUX F 424

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

USER MANUAL UN-200V / UN-200VH

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

OWNERS GUIDE TO INSTALLATION AND OPERATION

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

The sealless FLUX F 424

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Electric Pressure Washer

Pump - Owner s Manual

1800 PSI Electric Pressure Washer

2000 PSI Electric Pressure Washer

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Electric Pressure Washer

1600 PSI Electric Pressure Washer

Model: Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Integral Bowl Rinse Water/Waste Evacuation Pump

Installation & Operating Guide

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES. Model Series INSTALLATION

! WARNING. Before using product, read and understand instructions.

ENCLOSED UNIT TECHNICAL MANUAL Items # &

! WARNING. Before using product, read and understand instructions.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

! WARNING. Before using product, read and understand instructions.

INSTALLATION & OPERATION MANUAL

Model: Series DESIGNER STYLED MARINE TOILET. Model: Series FEATURES SPECIFICATIONS INSTALLATION OPERATION

1700 PSI Electric Pressure Washer

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

Installation & Operating Guide

QUICK PRIME INSTALLATION AND SERVICE MANUAL

The Safest Connections...

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

CHAMPION PUMP OWNER S MANUAL

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

INSTANT HOT WATER DISPENSER

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Model Series. Designer Styled Marine. Operation

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Model Series. Model Series QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES SPECIFICATIONS OPERATION

CLOSED COUPLED CENTRIFUGAL PUMPS

Model 53 Macerator Pump Installation, Operation, Repair Manual

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

Model Series QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES. Model Series INSTALLATION SPECIFICATIONS VARIATIONS AVAILABLE OPERATION

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

FLANGE-MOUNT CENTRIFUGAL PUMPS

LS-JRE OPERATION & INSTRUCTION MANUAL

E.2 series high efficiency circulator. Installation and operating instructions

ORIGINAL INSTRUCTIONS

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

QUICK PRIME INSTALLATION AND SERVICE MANUAL

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

690 and Power Fishing Systems

SMF PUMP OWNER S MANUAL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Elite Primer Baldor Series External Pond Pump

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

Model Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Quiet-Flush System. Model: Series FEATURES

S1700 Electric Pressure Washer

BEFORE OPERATING THE MACHINE: WARNING

Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Installation and operating instructions. E.2 Series high efficiency circulator

Panel Fan Series Operators Manual (Galvanized and Polymer)

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

K Specifications. Max. Water Volume

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

Appendix 1. Technical Drawings. Models CE5, CE7, CE10, CE14, CEN5, CEN7, CEN10

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Transcription:

Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload Protected Motor Compact Size Corrosion Protected Motor Quiet Running Snap-in 1/" (13 mm) Dia. Port Adaptors Conforms to Electromagnetic Compatibility 89/336/EEC and Machinery PumpAgents.com Directive 89/39/EEC, - Click here EN50081-1 for Pricing/Ordering SPECIFICATIONS Pump Body: Elastomers: Hardware: Pump Design: Suction Lift: Duty Cycle: Ports: Motor: Temperature: Viscosity: Shipping Weight: Glass Filled Polypropylene Santoprene** Diaphragm, Valves of * Stainless Steel Multi-Chamber Diaphragm Self-Priming to 10 ft (3 m) (wet) 5 ft (1.5 m) (dry) min. Continuous, Maximum 40 psi (.8 bar) at Ambient of 130 F (55 C) 1/" (13 mm) and 1/" (13 mm) Straight Pipe Thread Permanent Magnet with Thermal Overload Protection Liquid temperature range is 45 F (7 C) to 130 F (54 C) 50 centipoise maximum 7 lb (3. kg) approx. (1/4 V models) APPLICATIONS This pump provides excellent service in the following applications. CONSTRUCTION: Water supply pump to the spray bars of road rollers and other compaction equipment, street sweepers, and truck mounted dust control systems. AGRICULTURAL: Supply pump for herbicide and pesticide spraying equipment. INDUSTRIAL: Fluid transfer applications for mild acids and bases. Chemical feed pump. Washing fluid supply pump in parts washing systems. Machine coolant pump. Concrete saw lubricant supply pump. Recirculating pump in filtering systems. Road Rollers Spray Equipment Parts Washing Construction Equipment Washdown NOTE: equipped models are not suitable for potable water applications. Models 3180,3181 Series Protective Pressure Switch Settings Recommended Models Flow Coated Nominal psi (bar) AMP Draw Fuse/Breaker GPM (LPM) Voltage Motor Cut-In Cut-Out @ 10 psi Sizes 3180-049 3 (1) 1 Vdc YES N/A N/A 5 15 3180-0494 3 (1) 4 Vdc YES N/A N/A.5 7.5 3181-049 3 (1) 1 Vdc YES 5 (1.7) 40 (.8) 5 15 3181-0494 3 (1) 4 Vdc YES 5 (1.7) 40 (.8).5 7.5 * is a registered trademark of DuPont Dow Elastomers L.L.C. ** Santoprene is a registered trademark of Monsanto.

OPERATING INSTRUCTIONS! WARNING Fire hazard. Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death. 1. MOUNTING JABSCO diaphragm pumps are selfpriming and may be located in a dry location above or below the fluid supply. To vertically mount these units, it is best to do so with the motor on top. This will prevent fluid dripping on the motor in the event of a leak. Place pump on a solid surface and secure with four mounting screws being careful not to fully compress the rubber grommets which act as shock absorbers.. PLUMBING Port adaptors are supplied to fit 1/" (13 mm) dia. ID hose or 1/" (13 mm) dia. straight pipe threads. Use Teflon* (PTFE) type tape when threading straight pipe threads to tapered pipe threads. Select two of the port adaptors supplied to match your plumbing system. Flexible hose or tubing is recommended instead of rigid piping at pump. If you choose to use rigid piping, provide a short length of hose between pipe and the pump to avoid noise and vibration. Use clamps at both ends of hose to prevent air leaks. NOTE: Intake hose should be at least 1/" (13 mm) ID reinforced hose. A Pumpgard 36400-Series 1/" (13 mm) or 3600- Series 3/4" (19 mm) in-line strainer should be installed between pump and fluid supply to keep debris out of system. Avoid any kinks or fittings which could cause excessive restrictions. Remember to periodically clean Pumpgard screens. 3. WIRING DC MODELS In an easily accessible location, install an on-off switch (Jabsco 44960-Series) to control electricity to the pump. Turn the pump off when not used for extended periods, or when fluid supply is depleted. Orange Explosion hazard. Do not pump gasoline or other flammable liquids. To do so can cause an explosion resulting in injury or death. Black Orange Black Select wire size from chart below. Use total length of wire from electrical source to pump and return. Chart allows for 3% voltage drop. If in doubt, use next larger wire size. RECOMMENDED WIRE SIZES Total Wire Length feet (meters) Pump 0-0 0-35 35-55 Voltage (0-6) (6-11) (11-17) 1 Volt #14 AWG #1 AWG #10 AWG (.5 mm ) (4 mm ) (6 mm ) 4 Volt #16 AWG #14 AWG #1 AWG (1.5 mm ) (.5 mm ) (4 mm ) * TEFLON is a registered trademark of E.I. DuPont de Nemours and Company. The electrical circuit should be protected with an overcurrent protection device in the positive lead. See chart for proper size. The pump circuit should not include any other electrical loads. Black Wire from the motor is negative, orange is positive. If you are not familiar with applicable electrical standards, have the unit installed by a qualified electrician. After installation, check the voltage at the pump motor. Voltage should be checked when pump is operating. Full voltage must be available at the pump motor at all times. 4. SELF-PRIMING Pump is self-priming. Vertical dry lift capacity is 10 ft (3 m) (wet) 5 ft (1.5 m) (dry) min. Be sure suction piping is airtight or pump will not self-prime. 5. RUNNING DRY Pump can run dry indefinitely without damage. 6. CHEMICAL COMPATIBILITY Fluids being pumped must be compatible with the materials of construction. Consult factory for Chemical Compatibility Guide. Pump should be flushed with clean water or neutralizing solution after each use to prolong pump life. 7. PRESSURE Maximum continuous duty discharge pressure is 40 psi with an ambient temperature no greater than 130 F (55 C). NOTE: If the system operating pressure exceeds 50 psi, an external pressure relief value should be installed in the system. 8. TEMPERATURE The maximum recommended fluid temperature is 130 F (54 C). Minimum recommended fluid temperature is 45 F (7 C). 9. VISCOSITY The maximum pumped fluid viscosity is 50 centipoise. 10. DUTY CYCLE Motor and pump are designed for continuous operation in a 130 F (55 C) environment while pumping against 40 psi (.8 bar) discharge pressure. Beyond these parameters, an intermitted duty cycle is recommended to maximize pump life. In normal operation, motor case will get hot. Prolonged contact with motor could cause a burn on human skin. 11. START-UP AND OPERATION Check level of fluid in supply tank. Open all valves in system. Switch pump electrical circuit to on position. Flow will become steady as air is bled from system. For pumps equipped with pressure switch, close discharge valve after flow becomes steady fluid stream. Pump should shut off soon after closing valve. Pump is now ready for automatic operation. Pump will start when valve is opened and stop upon closure of valve. If pump is to be inoperative for a considerable period of time, flush pump with water, turn off electrical circuit to pump, and bleed system pressure by opening discharge valve. Pumps have thermal overload protected motors. The motor will automatically shut off as temperature rises due to an overload condition. If the motor shuts off in this manner, turn off electrical supply to pump. After a cooling off period, re-start pump.

SERVICE INSTRUCTIONS PUMP DISASSEMBLY 1. Remove power from pump. Open discharge valve to relieve system pressure.. Push port clips back and disconnect plumbing from pump. 3. Remove the four (4) pumphead screws. 4. Rotate pumphead until cam/bearing set screw is visible through drain notch. 5. Loosen cam/bearing set screw and slide pump off motor shaft. 6. Separate upper housing, lower housing, and check valve assembly as required. PUMP ASSEMBLY 1. Install new outer piston in lower housing with piston tops pointing away from motor.. Install new diaphragm in lower housing with the molded O-ring seals facing away from motor. 3. Insert each inner piston through the diaphragm into outer piston. 4. Turn each piston until fully seated. 5. Secure cam/bearing assembly to outer pistons using 18 inch pounds (.0 Nm) of torque. 6. Slide lower housing on motor shaft. Align set screw with motor shaft indentation. 7. Set screw MUST be positioned over shaft indentation and secured tightly. 8. Check that ferrules are installed in upper housing and O-ring is properly seated. 9. Install check valve assembly in upper housing and fit upper and lower housings together. 10. Align pumphead with motor and tighten four (4) screws evenly using 5 inch pounds (.8 Nm) of torque. SWITCH REPLACEMENT 1. Remove power from pump. Relieve system pressure. Disconnect inlet and outlet hoses.. Remove pressure switch cover and disconnect power leads from switch. 3. Remove switch and switch diaphragm from pump by removing two () switch mounting screws. 4. Replace switch diaphragm and switch. Reassemble in reverse order. 5. Do not over tighten switch mounting screws. OPTIONAL PORT KITS 30649-1004 1/" Threaded EPDM 30653-1004 3/4" Straight 30654-1004 1/" Straight Port Kits contain two ports with O-rings 3064-1004 90-3/4" 30651-1004 90-1/" EXPLODED VIEW 6 1 5 3 7 4 8 PARTS LIST 1 3 4 5 6 Model Upper Check Diaphragm Cam/Bearing Motor Pressure Housing Kit Valve Kit Kit Kit Kit Switch Kit 3180-049 18910-4019 18911-700 1891-3040 18913-000 18919-0116 3180-0494 18910-4019 18911-700 1891-3040 18913-000 18919-1040 3181-049 18910-4007 18911-700 1891-3040 18913-000 18919-0116 18916-0118 3181-0494 18910-4007 18911-700 1891-3040 18913-000 18919-1040 18916-0118 Bearing cover 7 not included in diaphragm Kit 3.

Total Pressure in PSI (bar) Amps www.pumpagents.com DIMENSIONS Inches (millimetres) 3180 9 1/ (41.0) 3 15/16 4X Ø3/16 MOUNTING HOLES 3 11/16 (93.7) (61.9) 7/3 (5.6) 3 1/ (88.9) (6.0) (50.8) 4 3/8 (111.0) 10 5/16 3181 3 15/16 4X Ø3/16 MOUNTING HOLES 3 11/16 (93.7) (61.9) 7/3 (5.6) 3 1/ (88.9) (6.0) (50.8) 4 3/8 (111.0) PERFORMANCE CURVES 70 60 (4) 50 (3) 40 30 () 0 (1) 10 1 & 4 VDC 1 VDC 4 VDC 0 0 1 3 4 (3.8) (7.6) (11.4) (15.1) Flow in U.S. GPM (LPM) 16 1 8 6 4 0 TROUBLESHOOTING PULSATING FLOW PUMP CYCLES ON AND OFF Restricted pump delivery. Check discharge lines, fittings and valves for undersizing or clogging. FAILURE TO PRIME MOTOR OPERATES, BUT NO PUMP DISCHARGE Restricted intake or discharge line. Air leak in intake line. Debris under flapper valves. Crack in pump housing. MOTOR FAILS TO TURN ON Loose wiring connection. Pump circuit has no power. Blown fuse/thermal Protector Tripped. Pressure switch failure. Defective motor. PUMP FAILS TO TURN OFF AFTER ALL VALVES ARE CLOSED Empty water tank. Discharge line leak. Defective pressure switch. Insufficient voltage to pump. Debris under flapper valves. LOW FLOW AND PRESSURE Air leak at pump intake. Accumulation of debris inside pump and plumbing. Worn pump bearing (excessive noise). Defective motor. Pumps have thermal overload protected motors. The motor will automatically shut off as temperature rises due to an overload condition. If the motor shuts off in this manner, close all nozzles, faucets or valves. After a cooling off period, the pump will automatically re-start. THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Jabsco Pumps Home >> Jabsco Pumps stock list >>