3M Personal Safety Division. Standards Update. NFPA 1981/1982, 2018 Edition. March 30, 2018

Similar documents
NFPA 1500 UPDATE CONTROLLING EXPOSURE TO FIREGROUND TOXIC CONTAMINANTS

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

SC # /16/17/18/19/23/24 D#03-24

Public Input No. 99-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

MINUTES OF THE MEETING TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT JULY 2015 SACRAMENTO, CA

Homeland Security Standard Panel (ANSI-HSSP) November 9, Standards Development in Response to Terrorism Threats

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

MEMORANDUM. Subject: NFPA 1124 Proposed Tentative Interim Amendment (TIA) No. 1094

ADDISON COUNTY FIREFIGHTERS ASSOCIATION MUTUAL AID SYSTEM STANDARD OPERATING GUIDELINES

At its meeting of August 7-9, 2012, the Standards Council considered the above referenced matter.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

City of Houston 2019 Houston Capital Needs Legislative Request

5.07 Air Replenishment Systems

Planning and Building Department APPLICATION FOR CEMETERY EXPANSION BAYVIEW CEMETERY, 720, 726 AND 740 SPRING GARDENS ROAD

Western Pennsylvania Conservancy Clairton & Harrison Community Greening Assessment Projects Request for Proposals July 2018

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

Charge for the Fire Station No. 8 History and Legacy Working Group Established by the County Manager on February 5, 2018

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

IAFF DIVISION OF OCCUPATIONAL HEALTH, SAFETY AND MEDICINE


Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

NFPA Electronic Safety Equipment Standards What s happening now!

home smoke candles alarms electrical burns smoking medical oxygen cooking FIREFIGHTING MATCHES & LIGHTERS SPRINKLERS

Texas Fire Chiefs Association DOCUMENT SUBMISSION FORM

c. DTAH Toronto Complete Streets Guidelines

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

NATIONAL FIRE PROTECTION ASSOCIATION The leading information and knowledge resource on fire, electrical and related hazards NFPA STANDARDS DIRECTORY

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation.

CITY OF VAUGHAN EXTRACT FROM COUNCIL MEETING MINUTES OF NOVEMBER 15, 2016

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

TECHNICAL COMMITTEE ON FIRE CODE

1. Delete in its entirety as follows:

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

MCSCS Proposed Changes to Fire Service Regulations

Proposed Changes to NFPA

2018 CALL FOR ENTRIES: DESIGN AWARDS

REQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES

Fire Sprinklers Working Group Final Report

Standards Council Meeting AGENDA. Hotel Mazarin 730 Bienville Street New Orleans, LA (504) April 10-11, 2018

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

9 CITY OF VAUGHAN OFFICIAL PLAN AMENDMENT NO BOCA EAST INVESTMENTS LIMITED

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

Sewanee Village + Request for Builder/Developer Proposals

GIS Data Exchange Committee. and the NFPA Standards Making System

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Council Members Chad Beebe and Daniel O Connor recused themselves during the deliberation and vote on this issue.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

MEETING OF THE TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT. NFPA 1989 and 1852 Second Draft Meeting. May 23-24, Virginia Beach, VA

CITY OF SIMI VALLEY MEMORANDUM

Fire Safety within the Kaipara District Plan Change 2 update and Summary of Proposed new Approach

Standard Development Timeline

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION GENERAL PROVISIONS

TERMS OF REFERENCE. General

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action.

1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M

The North American Electric Reliability Corporation ( NERC ) hereby submits

Telecommunication Facility Policy

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

AGENDA MEETING OF THE TOWN OF ALLEGANY PLANNING BOARD. Monday, November 9, 2015 at 7:00 p.m. Allegany Town Hall 52 W. Main Street, Allegany, NY

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

South of Eastern Strategic Direction Status Update

Changes for the New Edition. Senior Engineer, NFPA NFPA

Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

People who are members of historically disenfranchised racial, ethnic, cultural, and other identity groups are encouraged to apply.

ARLINGTON COUNTY PLANNING COMMISSION SITE PLAN REVIEW COMMITTEE SITE PLAN CHAIR GUIDE

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

Request for Qualifications For Administration of the 2016 Summer Sprout Program

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS

THE SCOTT PAK-ALERT DISTRESS ALARM

~!VAUGHAN NOV Z November 21, Mr. Denis Kelly, Regional Clerk The Regional Municipality of York Yonge Street Newmarket, ON L3Y 6Z1

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

EC Standard & NFPA 110 (EPSS) Documentation Best Practice. 1: Division Team Mission

Implementation Guidance for ISO 9001:2008

WHITE PAPER. Standard Product Safety Sign Catalog for Automotive Fire Apparatus RATIONALE

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Tucson Fire Department Early Alarm System, 3rd Edition

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Historical Perspectives for Hydrogen Safety, Regulations, Codes and Standards (California and U.S.A.)

Local Growth Planning in North Central Green Line Communities

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

The Director of Development Planning and Manager of Urban Design and Cultural Heritage recommends:

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CITY CLERK. Consolidated Clause in North York Community Council Report 8, which was considered by City Council on October 26, 27 and 28, 2004.

RESOLUTION TO REMOVE THE STATUE OF ROBERT E. LEE FROM LEE PARK

INTERNATIONAL SEMINAR

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

May 27, Mayor Thomas M. Roach Members of the Common Council City of White Plains 255 Main Street White Plains, New York 10601

Center for Life Safety Education

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

REQUEST FOR QUALIFICATIONS

Transcription:

3M Personal Safety Division Standards Update NFPA 1981/1982, 2018 Edition March 30, 2018

Standards Update NFPA 1981/1982, 2018 Edition The purpose of this presentation is to provide an update on the status of the NFPA 1981 and NFPA 1982, 2018 Edition standards. Topics: NFPA 1982, 2018 Edition Current Schedule NFPA 1982, 2018 Edition Published Changes NFPA 1981, 2018 Edition Current Schedule NFPA 1981, 2018 Edition Proposed Changes NFPA 1981, 2018 Edition Universal EBSS (UEBSS) NFPA 1981, 2018 Edition NITMAM NFPA 1981/1982, 2018 Edition Certification Process 3M 2017. All rights reserved. 3M confidential. 2

NFPA 1982, 2018 Edition Current Schedule

NFPA 1982, 2018 Edition Current Schedule The standard is marked as 2018 Edition The issuance date was November 10, 2017 The effective date was November 30, 2017 The last ship date for 2013 Edition PASS devices is confirmed as 12 months from the effective date 3M 2017. All rights reserved. 3M confidential. 4

NFPA 1982, 2018 Edition Published Changes

NFPA 1982, 2018 Edition Universal PASS Tone In December 2016, a Tentative Interim Amendment (TIA) was issued requiring all manufacturers of PASS devices to change the alarm tone as required in the NFPA 1982, 2013 Edition standard for PASS devices manufactured on December 21, 2016. This change was a result of firefighters expressing concerns about the performance and selection of the PASS tone chosen in the first iteration of the NFPA 1982, 2013 Edition standard. The new universal PASS alarm tone is incorporated as part of the NFPA 1982, 2018 Edition standard. 3M 2017. All rights reserved. 3M confidential. 6

NFPA 1982, 2018 Edition Transmitting PASS The standard includes (2) new RF PASS tests to improve reliability: Multi-hop Wireless networks use two or more wireless hops to convey information from a source to a destination. Multipath Propagation phenomenon that results in radio signals reaching the receiving antenna by two or more paths. Additional tests include: Point-to-Point RF Attenuation Loss-of-Signal Alarm RF Interference 3M 2017. All rights reserved. 3M confidential. 7

NFPA 1981, 2018 Edition Current Schedule

NFPA 1981, 2018 Edition Current Schedule The standard will be marked as 2018 Edition The issuance date is estimated to be August 2018 The effective date is estimated to be September 2018 The last ship date for 2013 Edition SCBA is confirmed as 12 months from the effective date Scott Safety estimates receiving NFPA 1981 approvals in early calendar year 2019 3M 2017. All rights reserved. 3M confidential. 9

NFPA 1981, 2018 Edition Proposed Changes

NFPA 1981, 2018 Edition Second Stage Regulator Retention & Removal Includes a strength of interface test between the facepiece and mask-mounted regulator to ensure that the mask-mounted regulator will not inadvertently pull out of the facepiece The test will pull the mask-mounted regulator by the low-pressure hose in 5 different directions at a force of 56.2 lbs. If the SCBA incorporates a removable regulator, two distinct actions for disconnection shall be required prior to removal of the regulator. Example: Pull latch and rotate regulator 3M 2017. All rights reserved. 3M confidential. 11

NFPA 1981, 2018 Edition Pneumatic Data-logging Minimum Requirements Initial Air Activation (pressure, date and time stamp) Data Logging @ 30 second intervals (pressure, date and time stamp) Data Logging of Pressure Milestones 100%, 75%, 50%, and 35% (EOSTI) Breathing Rate @ 30 second intervals (minimum 5 LPM resolution) HUD Deactivation (pressure, date and time stamp) Retain 36 hours of data Does not replace the PASS data-logging requirement for 2000 minimum events Output data to CSV file No requirement for temperature data log 3M 2017. All rights reserved. 3M confidential. 12

NFPA 1981, 2018 Edition Universal EBSS Fitting Incorporation of a standardized EBSS fitting that would be universal between all SCBA manufacturers The fittings are confirmed as Rectus 95 (male) and Rectus 96 (female). Current Scott fittings will not be compatible Minimum Requirements: The EBSS shall have an operating pressure range between 80 and 150 psi. The EBSS shall have a minimum hose length of 20 inches. The EBSS shall be removable from storage by the wearer using a single hand in a one-directional pull. The EBSS access location shall be readily visible to an assisting firefighter. The EBSS access location shall be marked UEBSS in letters that contrast with its background. 3M 2017. All rights reserved. 3M confidential. 13

NFPA 1981, 2018 Edition UEBSS A Closer Look

NFPA 1981, 2018 Edition UEBSS A Closer Look Scott Safety fully supports the intent of the UEBSS requirement to enable buddy breathing between firefighters using different SCBA manufacturer types, and has a working design that meets the requirements. However, the proposed requirement is not considerate of those fire departments that already use some form of EBSS and how the change to a universal fitting would impact their ability to perform EBSS operations. In essence, fire departments that are currently able to perform successful EBSS operations today with other departments using SCBA from the same manufacturer would cease to be compatible with their mutual aid partners, thus creating the problem that the proposed UEBSS requirement is trying to resolve. Scott Safety investigated alternative options to maintain both backward and forwardcompatibility and the solution was to offer an optional 3 rd fitting. This would maintain compatibility between new and existing SCBA users, ensuring safety for all firefighters. 3M 2017. All rights reserved. 3M confidential. 15

NFPA 1981, 2018 Edition UEBSS A Closer Look Scott Safety s proposed UEBSS solution Rectus 95 (male) Rectus 96 (female) Pressure Reducer (to limit the pressure to 150 psi max) 3 rd fitting (optional) 3M 2017. All rights reserved. 3M confidential. 16

NFPA 1981, 2018 Edition UEBSS A Closer Look Scott Safety sought guidance and was advised that the inclusion of a 3 rd fitting would not meet the intent of the proposed standard. Scott Safety proceeded to submit a request for Formal Interpretation to the NFPA Standards Council seeking a formal conclusion on whether a 3 rd fitting could be included. Scott Safety awaits a final decision from NFPA, but our expectation based on preliminary responses is for confirmation that the proposed standard does not allow for the inclusion of a 3 rd fitting. In an effort to prevent what Scott Safety believes will create an unintended safety issue within the fire service, our only option was to file a NITMAM. Scott Safety waited until the last possible day to file the NITMAM, hoping that we would receive a favorable response to our request for Formal Interpretation. 3M 2017. All rights reserved. 3M confidential. 17

NFPA 1981, 2018 Edition NITMAM

NFPA 1981, 2018 Edition NITMAM What is a NITMAM? Notice of Intent to Make a Motion Who can file a NITMAM? Under NFPA rules, any individual or organization wishing to make an allowable amending motion at an NFPA Technical Meeting must declare their intentions by filing, within the published deadline, a NITMAM. How is a NITMAM reviewed? The Motions Committee of the NFPA Standards Council reviews each NITMAM to determine whether the intended motion is a proper motion. Once certified by the Motions Committee, a NITMAM is presented for action at the NFPA Technical Meeting. 3M 2017. All rights reserved. 3M confidential. 19

NFPA 1981, 2018 Edition NITMAM When did Scott Safety file a NITMAM? Scott Safety filed a NITMAM on August 31, 2017. The NITMAM was certified by the Motions Committee on October 10, 2017. Why did Scott Safety file a NITMAM? Scott Safety waited until the last possible day to file the NITMAM, hoping to receive a favorable response to the request for Formal Interpretation. NFPA procedures did not permit Scott Safety to make a motion to add a third fitting to the standard, therefore the only option was to propose reverting to the EBSS language found in the current NFPA 1981, 2013 Edition standard. 3M 2017. All rights reserved. 3M confidential. 20

NFPA 1981, 2018 Edition NITMAM What is Scott Safety s rationale for filing the NITMAM? Scott Safety believes that the UEBSS requirements as proposed without consideration for an optional 3 rd fitting will create an unintended safety issue within the fire service. Scott Safety further believes that this unintended safety issue would not be undone for 15-20 years, at a minimum, as there are currently hundreds of thousands of SCBA in use in the North American fire service, a majority of which use some form of EBSS. Without consideration for an optional 3 rd fitting, those fire departments would be left incompatible with their neighboring jurisdictions. Beyond compatibility issues, the implementation of the UEBSS without the option for a 3 rd fitting could create logistical and safety issues within a fire department itself, as many departments specify new SCBA as part of new fire station construction or apparatus replacement. These fire departments would be forced to maintain different configurations of SCBA meeting different editions of the NFPA 1981 standard that would no longer be compatible with one another in EBSS operations. 3M 2017. All rights reserved. 3M confidential. 21

NFPA 1981, 2018 Edition NITMAM When will Scott Safety make a motion for removing the UEBSS requirements from the standard? Scott Safety will present our justification for filing the NITMAM at the next NFPA Technical Meeting scheduled for June 11-14 in Las Vegas, NV. The Chairman of the Technical Committee on Respiratory Protection Equipment will also have an opportunity to address the meeting attendees regarding the reasons why the UEBSS language was proposed as part of the NFPA 1981, 2018 Edition standard. What determines whether the motion is carried out? A consensus vote will be held by NFPA members to determine whether the NITMAM is approved or rejected. If approved, the UEBSS requirements will be removed from the proposed standard and replaced with the current language found in the NFPA 1981, 2013 Edition standard. If rejected, the UEBSS requirements will remain as written in the proposed NFPA 1981, 2018 Edition standard. 3M 2017. All rights reserved. 3M confidential. 22

NFPA 1981, 2018 Edition NITMAM How does the NITMAM impact the issuance of the NFPA 1981, 2018 Edition standard? Regardless of the outcome of the vote, the issuance date for the NFPA 1981, 2018 Edition standard will be delayed from what was previously communicated. Scott Safety estimates a new issuance date of August 2018, followed by an effective date of September 2018. How does the new issuance date impact SCBA manufacturers wishing to submit product for NFPA 1981, 2018 Edition certification? NFPA (SEI) has officially closed the submission window and will not re-open the submission window until the issuance date of the standard. Based on historical trends, Scott Safety estimates another 6-9 months before NFPA 1981, 2018 Edition certifications are issued. The end result manufacturers will not be able to provide SCBA approved to the NFPA 1981, 2018 Edition standard until sometime in early calendar year 2019. 3M 2017. All rights reserved. 3M confidential. 23

NFPA 1981, 2018 Edition Certification Process - SCBA

NFPA 1981, 2018 Edition Certification Process - SCBA The information below outlines the certification requirements for the NFPA 1981, 2018 edition standard. The NFPA Standards Council is expected to issue the NFPA 1981 standard in August 2018 NIOSH requires new TC approval numbers to be issued for each revision of the NFPA 1981 standard. This means that a manufacturer wishing to obtain NFPA 1981, 2018 certification must submit specific SCBA configurations to NIOSH in order to obtain new TC approval numbers. Manufacturers will be required to submit (3) separate applications, as listed below, for each SCBA that they wish to have tested and certified to the NFPA 1981, 2018 edition standard. NIOSH 42 CFR, Part 84 NFPA 1981 NIOSH CBRN 3M 2017. All rights reserved. 3M confidential. 25

NFPA 1981, 2018 Edition Certification Process - SCBA Safety Equipment Institute (SEI) is expected to begin accepting product submissions in August 2018. Once announced, the window for accepting product submissions will remain open for 30 days and is expected to close in September 2018. Manufacturers that submit product within the above submission window will be part of the first wave of testing and certification issuance. Manufacturers that miss submitting products during the above submission window will have their products tested after completion of the testing of the first wave of product submittals, resulting in certifications for products that missed the window being issued sometime after the first wave of certifications are issued. Test requirements include: NIOSH 42 CFR, Part 84 This testing is conducted at NIOSH NPPTL in Pittsburgh, PA. NFPA 1981 This testing is conducted at Intertek in Cortland, NY. NIOSH CBRN This testing is conducted jointly at NIOSH NPPTL in Pittsburgh, PA and RDECOM in Edgewood, MD. 3M 2017. All rights reserved. 3M confidential. 26

NFPA 1981, 2018 Edition Certification Process - SCBA Evaluation of products submitted for approval includes in-depth performance and qualification testing. This process is estimated to take 6-9 months for completion, beginning in October 2018. Approvals are granted in the following order: NIOSH 42 CFR, Part 84 NFPA 1981, 2018 edition and NIOSH CBRN jointly issued by SEI and NIOSH Scott Safety expects to receive approvals and be in a position to ship NFPA 1981/1982, 2018 edition products in spring 2019. 3M 2017. All rights reserved. 3M confidential. 27

NFPA 1981, 2018 Edition Certification Timeline

NFPA 1981/1982, 2018 Edition Certification Timeline NITMAM filed by Scott Safety (NFPA 1981) August 31, 2017 NFPA 1982 Issuance Date November 10, 2017 NITMAM presented at NFPA Technical Meeting June 11, 2018 NFPA 1981 Issuance Date (tentative) August 2018 NFPA 1981 Effective Date (tentative) September 2018 3M Scott Safety begins shipping 2018 approved Air-Pak X3 Pro (tentative) Spring 2019 October 10, 2017 November 30, 2017 July 2018 August 2018 Spring 2019 NITMAM certified by Motions Committee (NFPA 1981) NFPA 1982 Effective Date NFPA 1982 Approvals (tentative) SEI opens submission window (tentative) NFPA 1981 Approvals (tentative) 3M 2017. All rights reserved. 3M confidential. 29

NFPA 1981/1982, 2018 Edition Certification Process SCBA Upgrade Kits

NFPA 1981/1982, 2018 Edition Certification Process SCBA Upgrade Kits The information below outlines the certification requirements for upgrading legacy SCBA to the NFPA 1981/1982, 2018 edition standards. Manufacturers are required to submit separate applications for upgrading legacy SCBA approved to previous editions of the NFPA 1981 standard. The process for NFPA 1981 upgrade approval is identical to the initial certification process, with the additional requirement below: A requirement for achieving SCBA upgrade approvals is the submission of fielded units that have been upgraded for test and evaluation by the approval agencies. Historically, the approval agencies have not considered accepting submission applications for upgrades to legacy products until the initial wave of the new standard approvals is completed. Approvals cannot be issued for SCBA upgrades until the manufacturer has received the initial NFPA 1981, 2018 edition approval. 3M 2017. All rights reserved. 3M confidential. 31

s Thank You