F I R E S A F E T Y R E G I S T E R

Similar documents
Fire Safety Register

FIRE SAFETY REGISTER. Name of Premises: Address:

FIRE SAFETY LOG BOOK

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

PREMISES FIRE SAFETY LOGBOOK

ISLE OF WIGHT FIRE & RESCUE SERVICE

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

Fire Safety Log Book 41 page fire safety log book to record all your fire S afety checks Unique Fire Bordesley Green East Stechford Birmingham B33 8RU

Statutory Compliance Checklist

Handout Notes Major changes in BS : 2016

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Fire Procedures. April 2016

FIRE SAFETY LOGBOOK ADDRESS OF PREMISES NOMINATED RESPONSIBLE PERSON

THE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act

Maintenance of Fire Systems

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH

Appliance Make / Model Location Repaired I.S. 813* Annex C * Annex E * Type Installed Serviced Safety Check

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Grand Avenue Primary and Nursery School. Policy for Fire Safety. Contents. 6. Prevention of fire Events taking place outside school hours

Appliance Make / Model Location Repaired I.S. 813/I.S. EN 1949* Annex C * Annex E * Type Installed Serviced Safety Check

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Fire Safety Protocol

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Wellsprings Primary School. Fire Emergency Evacuation Plan

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations

A Guide to the Fire Safety Log Book For Small to Medium Business

Guidance on Statutory Inspections Scheduling Tool

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

Fire Safety Logbook. FOLLOW the regulations. MANAGE fire risks. RECORD relevant checks

LOG BOOK & CERTIFICATES

PLEASE KEEP AVAILABLE FIRE SAFETY

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL LOG BOOK & CERTIFICATES

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Dispute over the requirement for fire door signage to hotel suites at 124 Devon Street West, New Plymouth

Fire Safety Management

CHAPTER 5 - STRUCTURAL FIRE PRECAUTIONS

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

Fire Risk Assessment Report - Initial. 23 Newhaven Court, Nantwich, CW5 5GT

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Firetrax Professional Conventional Fire Control Panel

FIRE SAFETY POLICY Revised March 2013

FIRE SAFETY GUIDELINES for SCOUTING IRELAND Scout Dens and Meeting Places

OXNARD FIRE DEPARTMENT Fire Watch Guidelines

LA AUDIT ASSISTANCE SURVEY: Pre-survey checklist

Guidance Document on Caravan and Camping Sites Fire Safety Equipment Requirements

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Fire Safety Policy 2018/19

Fire Risk Assessment 2017

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

FIRE RISK ASSESSMENT Self Assessment

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

FIRE RISK ASSESSMENT

If there are more than ten people working other than on the ground floor,

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

FIRE PROCEDURES 1. APPOINTMENTS

Fire Safety Procedures and Associated Training

Fire Risk Assessment

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Fire Risk Assessment 2016

FIRE SAFETY AND PREVENTION POLICY

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

INTRUDER ALARM FOR BUSINESS SECURITY

DEPARTMENT OF FIRE & EMERGENCY SERVICES DNH.

MOIEZ AHMED Chief Fire Warden Director Training - Usha Armour Pvt. Ltd., Bangalore. Fire Drill (Fire Evacuation Drill Procedure)

Fire Alarm Control Panel. System Maintenance and Log Book

Fire Risk Assessment Guidance

Fire safety procedure

Control Panel User Guide

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

FIRE RISK ASSESSMENT

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

Fire Safety. A TUC guide for trade union activists

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

B. The Facility Emergency Planners and Alternate Planners will successfully complete the in-house DJJ Fire Prevention course.

FIRE RISK ASSESSMENT

HILBRE HIGH SCHOOL HUMANITIES COLLEGE

South Australian Regulatory Requirements

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Fire Risk Assessment Case Study

Transcription:

F I R E S A F E T Y R E G I S T E R (Short Version) Cork County Fire Department www.corkcoco.ie April 2015

Introduction 1.1 Section 18(2) of the Fire Services Acts, 1981 and 2003 generally applies to all premises other than a dwelling house occupied as a single private dwelling. This section of the Act places a duty on persons having control over premises to - take all reasonable measures to guard against the outbreak of fire, provide reasonable fire safety measures, prepare and provide appropriate fire safety procedures, ensure that the fire safety measures and procedures are applied at all times, and ensure as far as is reasonably practicable the safety of persons on the premises in the event of an outbreak of fire. 1.2 The Department of the Environment and Local Government has published guidance to assist persons in control of particular types of premises in discharging their statutory responsibilities under the Fire Services Act. The publications include the following:- Code of Practice for the Management of Fire Safety in Places of Assembly Guide to Fire Precautions in Existing Hotels, Guesthouses and Similar Premises Fire Safety in Guest Accommodation Fire Safety in Hostels Fire Safety in Nursing Homes 1.3 Compliance with responsibilities under the Fire Services Act requires that the premises must be suitable for its intended use and certain essential fire safety features appropriate to the use of the premises must be provided, and a proactive fire safety management policy must be in place to minimise the risk of a fire occurring and ensure the safety of persons on the premises in an emergency. 1.4 The keeping of fire safety records is an important element of the proper fire safety management of a premises. This Fire Safety Register has been produced to assist in the keeping of records for specific items. It will also be necessary to keep records and certificates for other items such as furnishings, bedding, electrical installations, as appropriate to the particular premises.

GUIDANCE FOR COMPLETION OF THE FIRE SAFETY REGISTER 1. The Register should be kept in a safe place on the premises at all times together with the relevant Code of Practice or Guide to Fire Precautions and should be available for inspection by any Authorised Officer of the Fire Authority. 2. The Register generally has sufficient pages to allow for records over a period of 5 years. Additional photocopies of unused pages should be added as required. 3. Owners or Managers of premises should take careful note of the intervals at which various inspections, tests or inventory/location checks are to be carried out. These are summarised in the table below. Daily Weekly Monthly Quarterly 6 Monthly Emergency Lighting Fire Alarm Extinguishers Hose Reels Fire Exit Doors Fire Resisting Doors Furniture Seating etc. Gas Installations General Wiring Yearly/ Periodic * * * Relevant Testing Interval Determined by Risk Assessment (but not greater than once every three years for gas installations and once every five years for general wiring)

INSPECTION AND TESTS ON FIRE PROTECTION EQUIPMENT A summary of the recommended tests for some fire protection systems and equipment is given below. More extensive details of the tests may be found in the relevant Irish Standard. Reference should also be made to the relevant guidance for a particular premises type, such as the Code of Practice for the Management of Fire Safety in Places of Assembly. Fire Extinguishers MONTHLY: All fire extinguishers should be inspected to make sure that appliances are in their proper position, have not been discharged or lost pressure (in the case of extinguishers fitted with a pressure indicator) or suffered obvious damage. Any extinguishers that are not available for use should be replaced by serviceable extinguishers. The frequency of inspections may need to be increased for premises where extinguishers are subject to tampering, damage, vandalism or malicious mischief ANNUALLY: A more thorough examination of extinguishers (a detailed description of which is given in I.S. 291: 2002) should be carried out by a person with the necessary training and experience, and with access to the requisite tools, equipment and information.. Extinguishers should be discharged periodically in accordance with the provisions of I.S. 291: 2002. When discharge is taking place the opportunity to train staff in the use of extinguishers should be taken. Hose Reels In accordance with BS 5306-1: 2006 the maintenance and testing of hose reels should be in accordance with IS EN 671-3: 2009. (If booster pumps have been installed, these and their associated mechanical and electrical equipment should also be checked. Emergency Lighting System Maintenance, inspection and testing of emergency lighting systems should be in accordance with Section 16 of I.S. 3217: 2013. Daily, weekly, quarterly and annual inspections and testing should be carried out by competent persons and relevant certification retained for inspection. Samples of the relevant quarterly report and annual certificate are included in this register. Fire Detection And Alarm System Maintenance, inspection and testing of the fire detection and alarm system should be in accordance with Section 9.2 of I.S. 3218: 2013. Daily, weekly, quarterly and annual inspections and testing should be carried out by competent persons and relevant certification retained for inspection. Gas Installations The following guidance is set out in Annex E of IS 820: 2010 and deals with safety inspections of existing non-domestic installations (Any reference contained in text below is to IS 820:2010). General Annex E sets out a method by which existing installations, already constructed and commissioned shall be inspected to ensure that it is safe for continued operation. The inspection shall be carried out by a competent person authorised to do so by the operator on an occasional basis or as part of a planned maintenance programme, see 10.2, or Competent persons shall, on behalf of the gas supplier, carry out an inspection: - in the immediate aftermath of a reported abnormal situation (see 10.3), or - prior to re-supplying a premises or part thereof (see 10.7). Scope of inspection The following essentials to the safe use of gas and gas appliances shall be checked: -Pipework: soundness of pipework, and visible condition of exposed sections; and -Appliances: visual evidence of appropriate location, availability of sufficient combustion air and the existence of a connected effective flue, when required. Required actions: 1 Should the inspection reveal an unsafe situation the installation shall be taken out of use or shall not be brought into use pending full rectification and the issuing of a declaration of conformance, see clause 9. 2 Should the inspection reveal aspects of the installation which do not conform to the requirements of this standard or which are otherwise found unsatisfactory but is deemed safe to operate then a Notification of Hazard shall be issued to the operator by the competent, authorised person conducting the inspection. 3 A specimen of a Notification of Hazard is contained in Annex D.3 Soundness test of an existing installation When soundness testing an existing installation a fitness test as required in 7.1.4 is considered appropriate. Appliances or other parts of the installation, which can be shut down separately and

secured in the closed position, may be isolated and the gas supply provided/restored to the remaining sections of the installation which prove to be sound. Visual inspection of exposed pipework There shall be no evidence of physical damage or mechanical failure. The integrity of the pipework shall not be threatened by corrosion. Appliance location A visual check shall establish that the appliance is located in accordance with manufacturer's recommendations, with the requirements of this Standard and, bearing in mind site conditions, a location where it can be operated safely. Combustion air A visual inspection/ measurement shall establish that sufficient combustion air is permanently available to the appliance in accordance with manufacturer's recommendations. Where there is doubt about the adequacy of the permanent supply of combustion air, reference shall be made to 11.7 of this Standard. Adequacy of connected flue Atmospheric flues, with the appliance operating or with the introduction of an available alternative heat source, shall be checked by appropriate means to establish that a positive up draft is available and there is no noticeable spillage from the appliance. Flues which operate with forced or assisted draft shall be checked to establish that the appliance served can not be operated in the event of fan failure/non-availability. When reasonably practical, flues shall be visually inspected to establish the absence of corrosion, damage or other deterioration which might affect the structure or integrity of the flue. Where reasonably practical, the flue terminal shall be inspected to confirm that it is correctly located and the opening is not obstructed and is free from combustible material. General Wiring 1. All new electrical installations or a major alterations or an extension to an existing installation shall, after completion, be inspected and tested by a competent person and a certificate of test be obtained verifying that the relevant requirements of the ETCI National Rules for Electrical Installations. 2. All existing installations shall be tested by a competent person in an appropriate manner at an interval determined by risk assessment having regard to the nature, location and use of the installation (but not greater than five years) and a report, conforming to Annex 62A of the ETCI National Rules for Electrical Installations, of the test be completed by the competent person carrying out the test. Any works required to make the installation safe for use detailed in this report shall be carried out and a new report be completed by a competent person.

FIRE SAFETY REGISTER PREMISES and MANAGEMENT DETAILS PREMISES _ ADDRESS Telephone Number Name of Owner/Hirer/Lessee Name of FIRE SAFETY MANAGER Name of DEPUTY FIRE SAFETY MANAGER

CONTENTS SECTION 1 Specific Fire Protection Duties Assigned to Staff Members 2 Staff Instruction and Training Fire and Evacuation Drills 3 Weekly Sign-Off Sheet for Premises Staff 4A Fire Fighting Equipment Annual Inventory 4B Fire Fighting Equipment Location 4C Fire Fighting Equipment Annual Maintenance 5A Emergency Lighting Quarterly Inspection and Test 5B Emergency Lighting Annual Service & Test Certificate 6 Fire Alarm Quarterly and Annual Test Certificates 7A Gas Installations Periodic Inspection Certificate 7B Schedule of Periodic Inspection, Testing & Servicing Due Dates for Gas Installations 7C Schedule of Periodic Inspection, Testing & Servicing Due Dates for General Wiring

1. SPECIFIC FIRE PROTECTION DUTIES ASSIGNED TO STAFF MEMBERS Name Position Duties _ Name Position Duties Name Position Duties Name Position Duties Name Position Duties

2. STAFF INSTRUCTION AND TRAINING INCLUDING FIRE AND EVACUATION DRILLS Date Instructor Nature Duration Date Instructor Nature Duration Date Instructor Nature Duration

3. Weekly Check Sign-Off Sheet for Premises Staff Date Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Week Beginning / / Fire Alarm Emergency Lighting Extinguishers Exits (Daily Checks) Fire Doors M T W T F S S Electro Magnetic Devices Upholstered Seating & Furniture Comments / Issues Sign Off

4A. ANNUAL INVENTORY OF FIRE FIGHTING EQUIPMENT This list should be updated on an annual basis at the time of the annual inspection and test of fire fighting equipment. Month Year Number of Water Extinguishers Number of Foam Extinguishers Number of AFFF Extinguishers Number of CO 2 Extinguishers Number of Dry Powder Extinguishers Number of Hose Reels Number of Fire Blankets Other Equipment

4B. LOCATION OF FIRE FIGHTING EQUIPMENT Fire Point Number Location Type of extinguisher or other equipment Size of extinguisher or details of other equipment

4C. ANNUAL MAINTENANCE OF FIRE FIGHTING EQUIPMENT Date of Inspection / Test Number of Fire Extinguishers Inspected Number of Fire Blankets Inspected Number of Hose Reels Inspected Observations This is to certify that the Fire Fighting Equipment been serviced in accordance with the relevant standards. Signed For and on behalf of SERVICE COMPANY 4C. ANNUAL MAINTENANCE OF FIRE FIGHTING EQUIPMENT Date of Inspection / Test Number of Fire Extinguishers Inspected Number of Fire Blankets Inspected Number of Hose Reels Inspected Observations This is to certify that the Fire Fighting Equipment been serviced in accordance with the relevant standards. Signed For and on behalf of SERVICE COMPANY

5A Emergency Lighting System Report for Inspection, Testing & Servicing This is not a certificate of annual inspection and testing or a final certificate of commissioning. This report shall be printed on paper clearly showing the inspection, testing or servicing company s details Applicable standard(s) to which the Emergency Lighting System was installed: [tick appropriate box(s)] I.S. 3217:1989 I.S. 3217:2008 I.S. 3217:2013 Evidence of commissioning available Yes No [tick as appropriate] Building Name, Owner and/or Occupier Address of Building Description of Works.... Record Drawings. The Inspection, Testing and Servicing work covered by this report is set out below (tick appropriate box): Quarterly Inspection and Test Special Servicing following a fault Other non-routine attention I/We hereby declare that the Emergency Lighting System at the above building, and as detailed above, has been inspected, tested and/or serviced by me/us in accordance with the requirements of 16.2.4 (quarterly inspection) of I.S. 3217: 2013 and with reference to the applicable standard(s) to which the emergency lighting system was installed, that all relevant details have been recorded in the logbook in accordance with Clause 14 and the schedule for periodic inspections and tests due dates has been updated. I/We hereby declare that where this report relates to a special servicing following a fault(s) and/or other non-routine attention that the details of any deficiencies, defects and/or faults otherwise discovered and any necessary corrective action(s) required or carried out have been recorded in the logbook. Comments/Recommendations:.. I/We confirm my/our competence to undertake this work Name Signed. Position.. Date / /.. For and on behalf of (Company)

5B Emergency Lighting System Certificate for Annual Inspection & Testing This is not a final certificate of commissioning. This certificate shall be printed on paper clearly showing the inspection, testing or servicing company s details A copy of this certificate shall be retained by the person/company responsible for issuing it. Certificate Number Applicable standard(s) to which the Emergency Lighting System was installed and is now being certified against: [tick appropriate box] I.S. 3217:1989 I.S. 3217:2008 I.S. 3217:2013 Is commissioning certificate available Yes No [tick as appropriate] Building Name, Owner and/or Occupier Description of Works and area being certified... Record Drawings. System Type: [tick appropriate box(s)] Self-Contained Central Powered System ATS Comments on system type I/We hereby certify that the Emergency Lighting System at the above building, and as detailed above, has been inspected and tested by me in accordance with the relevant requirements of 16.2.5 of I.S. 3217: 2013 and with reference to the applicable standard(s) to which the emergency lighting system was installed, confirm that there are no deviations or faults with the system as of the date of this declaration. I/We confirm our competence to carry out this work. Name Signed. Position.. Date / /.. For and on behalf of (Company) Comments...

6 Fire Detection and alarm system Certificate of Servicing/Testing Page 1 of 2 [to be given to user after completion of service] Certificate Number:. Name of Company and or person responsible for Servicing/Testing Address of above:.. Certificate of testing of the fire alarm system at: Name of protected premises or owner:. Address of protected premises: System Category (tick as appropriate) M L4 L3 L2/L4 L2/L3 L1 Variations as attached The Servicing and Testing work covered by this certificate is as set out below (tick appropriate box): Quarterly Servicing and Testing as in 9.2.2.5 Y/N Annual Servicing and Testing as in 9.2.2.6 (including dates of interim certificates as below) Quarter 1 Quarter 2 Quarter 3 Quarter 4 Date Tested Special servicing following a fire (the work set out in 9.2.3.2 has been completed). Special servicing following a false alarm (the work set out in 9.2.3.3 has been completed). Special servicing following excessive false alarms (the work set out in 9.2.3.3 has been completed and the User has been advised of the requirements of 7.3.5, 7.3.6, 7.5.2 and 7.5.4). Special servicing following a fault (the work set out in 9.2.3.4 has been completed). Special servicing following a pre-alarm (the work set out in 9.2.3.5 has been completed). Other non-routine attention (specify as 9.2.3.7 or detail other works). NOTE Page 2 of this certificate shall be completed, signed and dated.

Fire Detection and alarm system Certificate of Servicing/Testing Page 2 of 2 I/We confirm my/our competence to undertake this work and certify that the following items have been checked during the works indicated on page 1 of this Certificate, and that consequently the system is operational and compliant in relation to these works Entries in the Logbook have been checked (as 9.2.2.5) Alarm functions and controls have been checked (as 9.2.2.5) A visual inspection of any structural or occupational changes has been made (as 9.2.2.5) and the system has been modified accordingly as per I.S. 3218: 2013. A clear space of at least 500 mm is preserved in all directions below and around every detector (as 9.2.2.5.1(5)). Detectors are sited and spaced in accordance with 6.10.3 and 6.10.4. All manual call points have been checked and remain unobstructed and conspicuous (as per 9.2.2.5 or 9.2.2.6 c)). Sounders and any link to an ARC have been tested and are operational (as 9.2.2.5, and as 9.2.2.6 a) and 9.2.2.6 e)). Wiring, cables and cable fitting have been visually checked (as 9.2.2.6 d)) and they remain secure, undamaged and adequately protected. Any defects have been recorded in the Logbook and reported to the Responsible Person for appropriate action (as in 9.2.2.5). A Schedule of Service (as Annex D 2) has been completed and affixed adjacent to the Fire Alarm Control Panel. Signature of Authorised Person responsible for servicing/testing of the system Name (Print):.. Position:.. Signed:.. Date:../ /. For and on behalf of (user or Service Provider):.....

7. Periodic Safety Inspection for Gas Installations (I.S. 820:2010 Non Domestic Gas Installations) Name of Premises Premises Address Date of Inspection and Test_ I hereby declare that the gas installation at the above premises has been inspected and tested by me in accordance with Annex E of I.S. 820:2010 Non Domestic Gas Installations, published by the National Standards Authority of Ireland, and in my opinion is safe for continued operation. Inspection carried out by (SERVICE COMPANY) RGI Number: Company Address Telephone No. Signature of person responsible for inspection and test: _ Name (block capitals): Details of variation (if any) from I.S. 820:2010 :

Annex E of IS 820: 2010: Safety inspections of existing non-domestic installations (Any reference contained in text below is to IS 820:2010) E.1 General This annex sets out a method by which existing installations, already constructed and commissioned shall be inspected to ensure that it is safe for continued operation. The inspection shall be carried out by a competent person authorised to do so by the operator on an occasional basis or as part of a planned maintenance programme, see 10.2, or Competent persons shall, on behalf of the gas supplier, carry out an inspection: - in the immediate aftermath of a reported abnormal situation (see 10.3), or - prior to re-supplying a premises or part thereof (see 10.7). E.2 Scope of inspection The following essentials to the safe use of gas and gas appliances shall be checked: -Pipework: soundness of pipework, and visible condition of exposed sections; and -Appliances: visual evidence of appropriate location, availability of sufficient combustion air and the existence of a connected effective flue, when required. E.3 Required actions E.3.1 Should the inspection reveal an unsafe situation the installation shall be taken out of use or shall not be brought into use pending full rectification and the issuing of a declaration of conformance, see clause 9. E.3.2 Should the inspection reveal aspects of the installation which do not conform to the requirements of this standard or which are otherwise found unsatisfactory but is deemed safe to operate then a Notification of Hazard shall be issued to the operator by the competent, authorised person conducting the inspection. E.3.3 A specimen of a Notification of Hazard is contained in Annex D.3 E.4 Soundness test of an existing installation E.4.1 When soundness testing an existing installation a fitness test as required in 7.1.4 is considered appropriate. E.4.2 Appliances or other parts of the installation, which can be shut down separately and secured in the closed position, may be isolated and the gas supply provided/restored to the remaining sections of the installation which prove to be sound. E.5 Visual inspection of exposed pipework E.5.1 There shall be no evidence of physical damage or mechanical failure. E.5.2 The integrity of the pipework shall not be threatened by corrosion. E.6 Appliance location A visual check shall establish that the appliance is located in accordance with manufacturer's recommendations, with the requirements of this Standard and, bearing in mind site conditions, a location where it can be operated safely. E.7 Combustion air A visual inspection/ measurement shall establish that sufficient combustion air is permanently available to the appliance in accordance with manufacturer's recommendations. Where there is doubt about the adequacy of the permanent supply of combustion air, reference shall be made to 11.7 of this Standard. E.8 Adequacy of connected flue E.8.1 Atmospheric flues, with the appliance operating or with the introduction of an available alternative heat source, shall be checked by appropriate means to establish that a positive up draft is available and there is no noticeable spillage from the appliance. E.8.2 Flues which operate with forced or assisted draft shall be checked to establish that the appliance served can not be operated in the event of fan failure/non-availability. E.8.3 When reasonably practical, flues shall be visually inspected to establish the absence of corrosion, damage or other deterioration which might affect the structure or integrity of the flue. E.8.4 Where reasonably practical, the flue terminal shall be inspected to confirm that it is correctly located and the opening is not obstructed and is free from combustible material.

7B Schedule of Periodic Inspection, Testing & Servicing Due Dates for Gas Installations Date Signature Inspection/Test was carried out Name of Person responsible for carrying out Inspection/Test Date next Inspection/Test is Due 7C Schedule of Periodic Inspection, Testing & Servicing Due Dates for General Wiring Date Inspection/Test was carried out Name of Person responsible for carrying out Inspection/Test Signature Date next Inspection/Test is Due