C 083-03 Bali R Cast-iron boilers with atmospheric gas-fired burner Life-enhancing heat GB
Cast-iron boilers with atmospheric gas-fired burner Bali R Easy installation Silent operation Long life Wide range Modern design and style Easy operation
Life-enhancing heat BALI R is Fondital s family of cast-iron boilers with atmospheric gas-fired burner. BALI comes in 23 different open chamber versions, capacity 18-100 kw, and 4 sealed chamber versions, capacity 18-36.5 kw. FONDITAL s modern, new range of BALI boilers features a versatile, high-tech cast-iron heat exchanger, piezoelectric or electronic ignition, high efficiency (in some models as high as 93 %), and reduced flue gas emissions. BALI boilers come in the following models: BALI RTN CH open chamber boiler, piezoelectric ignition, 5 versions, heat output 18-48 kw. BALI RTN PV CH open chamber boiler, equipped with circulating pump and expansion vessel, piezoelectric ignition, 4 versions, heat output 18-36 kw. BALI RTN E CH open chamber boiler, electronic ignition, 10 versions, heat output 18-100 kw. BALI RTN PVE CH open chamber boiler, equipped with circulating pump and expansion vessel, electronic ignition, 4 versions, heat output 18-36 kw. Model RTFS E Bali R WHPF BS Model RTN PVE Bali R WHPF BO BALI RTFS E CH sealed chamber boiler, electronic ignition, 4 versions with heat outputs 18-36.5 kw. The various versions of BALI boiler can be connected to WHPF BS or WHPF BO domestic hot water cylinders by Fondital. By using the electric board (code 0KITBEST06), supplied as an aption, the various versions of Bali boiler can be connected to WHPF BS domestic hot water cylinders by Fondital. Three different heating zones can be managed installing the optional electric board code 0KITPOMZ00. The quality of a boiler can also be seen from the materials of which it is made. This is why Fondital has chosen superior quality components for the BALI range and has built the body of top quality cast-iron to ensure extended performance and extra reliability. The cast-iron core allows for a full range of heating outputs and ensures cost saving and efficiency for many years. In the wetback combustion chamber there are staggered hubs to ensure natural circulation of the water in each element. These special features of BALI boilers are guarantee of excellent performance. But this still does not come up to Fondital s standard. The surface of the heat exchanger is covered in projections in the shape of a truncated rhomboid pyramid increasing in size along the path of flue gas, for better heat exchange and therefore efficiency. CAST-IRON BODY ATMOSPHERIC BURNER Inside the cast-iron body is a gas-fired atmospheric burner made of stainless steel. This type of burner features a very silent operation and top performance to ensure, in combination with the body, high efficiency and low emissions. All models of BALI boiler obtained the 2-star rating according to Efficiency Directive 92/42 EEC, and some have been awarded the 3-star rating due to their excellence.
Life-enhancing heat Extensive research has gone into the design and construction of the instrument panel. The result is a modular, ergonomic design and the performance can be enhanced by adding other modules inside. The standard configuration of the instrument panel on BALI boilers holds the gas burner controls, temperature control and display, operating lights, safety thermostat, reset button, and heating pump control and water pressure switch. The instrument panel can also host a thermoregulation unit. STANDARD INSTRUMENT PANEL 1 2 3 11 7 4 5 6 8 9 10 1. Temperature control unit and timer (both optional equipment) 2. Heating pump light (yellow) 3. Overheating emergency light (red) 4. Burner emergency light (red) 5. Burner on light (yellow) 6. Thermometer 7. Burner reset button 8. Illuminated main switch (green light) 9. Temperature control 10. Manual reset after overheating shutdown 11. Flue gas overheating light, model RTN E, and low gas pressure light, model RTN E 70-100 (red). The BALI range of FONDITAL boilers is the ideal answer to a wide variety of engineering requirements. The range includes open chamber and sealed chamber models ready for installation in boiler rooms or any room in the house. Some models are equipped with a circulating pump and expansion vessel, and some have complex circuits with no need for extra plumbing for special configurations. These highly versatile boilers are designed specifically for more classic installations. Some models have piezoelectric ignition and others electronic ignition with an intermittent pilot. But the versatility of BALI boilers does not stop here: Fondital has designed this range of compact boilers to save space and make them ideal for any public or private building. This is why the draught-diverter is housed inside the boiler and the castiron body is fully modular in depth. Great study has been applied to the internal layout. In all models in the BALI range, components are housed at or near the front for easy access. All these features have been developed by Fondital with the requirements of fitters and service engineers in mind. DIMENSIONS BALI RTN / RTN E 18 48 BALI RTN / RTN E Models L D G M R BALI 18 525 110 G 3/4 G 1 1/4 G 1 1/4 BALI 24 525 130 G 3/4 G 1 1/4 G 1 1/4 BALI 32-36 625 130 G 3/4 G 1 1/4 G 1 1/4 BALI 48 765 150 G 3/4 G 1 1/4 G 1 1/4 BALI RTN PV / RTN PVE 18 36 BALI RTN PV / RTN PVE Models L D G M R BALI 18 525 110 G 3/4 G 3/4 G 3/4 BALI 24 525 130 G 3/4 G 3/4 G 3/4 BALI 32-36 625 130 G 3/4 G 3/4 G 3/4
Cast-iron boilers with atmospheric gas-fired burner BALI R BALI RTN E 60 100 BALI RTN E Models L D G M R BALI 60 935 180 G 1 G 1 1/2 G 1 1/2 BALI 70 1052 180 G 1 G 1 1/2 G 1 1/2 BALI 80 1153 200 G 1 G 1 1/2 G 1 1/2 BALI 90 1280 220 G 1 G 1 1/2 G 1 1/2 BALI 100 1430 250 G 1 G 1 1/2 G 1 1/2 BALI RTFS E 18 36 BALI RTFS E Models L G M R BALI 18-24 510 G 1/2 G 1 G 1 BALI 32-36 610 G 1/2 G 1 G 1 ACCESSORIES Item Description Code Electric kit for three different CH temperature area management Electric kit for connection to external cylinder 0KITPOMZ00 0KITBEST06 Hydraulic kit for connection to WHPF BO horizontal water tank Pump and 12-lt. expansion vessel kit with manometer, pressure switch, safety valve (RTN, RTNE, RTFSE models) Hydraulic kit for connection to WHPF BO horizontal water tank, including pump and expansion vessel (RTN, RTNE, RTFSE models) 0KITPOVA03 0KITPOVA04 0KITPOVA05 Thermoregulation control unit kit Remote control for thermoregulation control unit (temperature regulation) Remote control for thermoregulation control unit (all functions) Daily timer kit Weekly timer kit 0KITCEEL02 0CREMOTO00 0CREMOTO01 0KITBEST04 0KITBEST05
Cast-iron boilers with atmospheric gas-fired burner MAIN FEATURES Class Heat output Heat input Ignition Efficiency at nominal output Efficiency at reduced load (30%) Efficiency rating CE Maintaining loss at T = 50 C Heat loss at the chimney with burner off Heat loss at the chimney with burner on Flue gas temperature (G 20 nat. gas) Flue gas temperature (G 30) Flue gas mass output (G 20 nat. gas) Flue gas mass output (G 30) Max. operating pressure Water content Minimum water flow rate Load loss on the water side Maximum hot water temperature Burner gas pressure (G 20 nat. gas) Burner gas pressure (G 30) Flue gas discharge pipe diameter Flow pipe diameter Return pipe diameter Gas inlet diameter Expansion vessel capacity Pump head Mains voltage and frequency Wattage Dimensions: Width Depth Height Net weight BALI (Piezoelectric ignition) RTN 18 RTN 24 RTN 32 RTN 36 RTN 48 kw 20 26.6 34.4 39.2 52.8 kw 18 24 31.5 36 48 PIEZOELECTRIC % 89.6 90.9 90.9 90.83 91.84 % 89.2 91.1 89.0 90.75 90.4 % 3.6 2.8 3.1 1.57 1.76 % 0.2 0.2 0.2 0.2 0.2 % 6.8 6.3 6 7.6 6.4 C 110/120 110/120 120/130 120/130 120/130 C 110/120 110/120 120/130 120/130 120/130 Kg/h 42 56 63 70 88 Kg/h 40 53 60 64 80 bar 4 4 4 4 4 l 10 10 13.4 13.4 16.8 l/h 400 520 680 770 1030 w.c.m. 0.4 0.4 0.6 0.6 0.8 C 85 85 85 85 85 mbar 9.5 11.0 9.5 12.0 12.5 mbar 26 26 25.5 26.8 26 Ø 110 130 130 130 150 Ø 1" 1/4 1" 1/4 1" 1/4 1" 1/4 1" 1/4 Ø 1" 1/4 1" 1/4 1" 1/4 1" 1/4 1" 1/4 Ø 3/4" 3/4" 3/4" 3/4" 3/4" l -- -- -- -- -- w.c.m. -- -- -- -- -- V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 W 10 10 10 10 10 mm 450 450 450 450 450 mm 525 525 625 625 765 mm 850 850 850 850 850 Kg 105 105 138 138 173 Class Heat output Heat input Ignition Efficiency at nominal output Efficiency at reduced load (30%) Efficiency rating CE Maintaining loss at T = 50 C Heat loss at the chimney with burner off Heat loss at the chimney with burner on Flue gas temperature (G 20 nat. gas) Flue gas temperature (G 30) Flue gas mass output (G 20 nat. gas) Flue gas mass output (G 30) Max. operating pressure Water content Minimum water flow rate Load loss on the water side Maximum hot water temperature Burner gas pressure (G 20 nat. gas) Burner gas pressure (G 30) Flue gas discharge pipe diameter Flow pipe diameter Return pipe diameter Gas inlet diameter Expansion vessel capacity Pump head Mains voltage and frequency Wattage Dimensions: Width Depth Height Net weight BALI (Electronic ignition) RTN E 18 RTN PVE 18 RTN E 24 RTN PVE 24 RTN E 32 RTN PVE 32 RTN E 36 RTN PVE 36 kw 20 26.6 34.4 39.2 kw 18 24 31.5 36 ELECTRONIC % 89.6 90.9 90.9 90.83 % 89.2 91.1 89.0 90.75 % 3.6 2.8 3.1 1.57 % 0.2 0.2 0.2 0.2 % 6.8 6.3 6 7.6 C 110/120 110/120 120/130 120/130 C 110/120 110/120 120/130 120/130 Kg/h 42 56 63 70 Kg/h 40 53 60 64 bar 4 4 4 4 l 10 10 13.4 13.4 l/h 400 520 680 770 w.c.m. 0.4 -- 0.4 -- 0.6 -- 0.6 -- C 85 85 85 85 mbar 9.5 11.0 9.5 12.0 mbar 26 26 25.5 26.8 Ø 110 130 130 130 Ø 1" 1/4 3/4" 1" 1/4 3/4" 1" 1/4 3/4" 1" 1/4 3/4" Ø 1" 1/4 3/4" 1" 1/4 3/4" 1" 1/4 3/4" 1" 1/4 3/4" Ø 3/4" 3/4" 3/4" 3/4" l -- 8 -- 8 -- 8 -- 12 w.c.m. -- 2.8 -- 2.8 -- 2.5 -- 2.5 V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 W 10 110 10 110 10 110 10 110 mm 450 450 450 450 mm 525 525 625 625 mm 850 850 850 850 Kg 105 125 105 125 138 158 138 158
Bali R RTN PV 18 RTN PV 24 RTN PV 32 RTN PV 36 20 26.6 34.4 39.2 18 24 31.5 36 PIEZOELECTRIC 89.6 90.9 90.9 90.83 89.2 91.1 89.0 90.75 3.6 2.8 3.1 1.57 0.2 0.2 0.2 0.2 6.8 6 7.6 7.6 110/120 110/120 120/130 120/130 110/120 110/120 120/130 120/130 42 56 63 70 40 53 60 64 4 4 4 4 10 10 13.4 13.4 400 520 680 770 -- -- -- -- 85 85 85 85 9.5 11.0 9.5 12.0 26 26 25.5 26.8 110 130 130 130 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 8 8 8 12 2.8 2.8 2.5 2.5 230/1/50 230/1/50 230/1/50 230/1/50 100 100 100 100 450 450 450 450 525 525 625 625 850 850 850 850 125 125 158 158 RTN E 48 RTN E 60 RTN E 70 RTN E 80 RTN E 90 RTN E 100 52.8 66.0 76.3 87.3 98.2 109.7 48 60 70 80 90 100 ELECTRONIC 91.84 91.7 91.7 91.7 91.6 91.6 90.4 90.6 90.4 90.3 90.3 90.22 1.8 1.8 1.7 1.6 1.5 1.2 0.2 0.2 0.2 0.2 0.2 0.2 6.4 6.5 6.6 6.7 7.0 7.2 120/130 110/120 110/120 120/130 110/120 110/120 120/130 110/120 110/120 120/130 110/120 110/120 88 114 136 144 200 223 80 134 154 158 225 252 4 4 4 4 4 4 16.8 20.2 23.5 26.8 30.1 33.4 1030 1200 1500 1700 1900 2100 0.8 0.8 0.9 0.9 0.9 0.9 85 85 85 85 85 85 12.5 11.5 13.4 12 11 11.6 26 26 26 25.5 26.8 26 150 180 180 200 220 250 1" 1/4 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/4 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 3/4" 1" 1" 1" 1" 1" -- -- -- -- -- -- -- -- -- -- -- -- 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 10 20 20 20 20 20 450 450 450 450 450 450 765 935 1052 1153 1280 1430 850 1000 1000 1000 1000 1000 173 215 250 285 320 355
The manufacturer reserves the right to implement modifications without notice. Cast-iron boilers with atmospheric gas-fired burner BALI R 9PCGB03C083 TECHNICAL DATA MODEL RTFS E 18 RTFS E 24 RTFS E 32 RTFS E 36 Class Heat output kw 20 26.6 34.4 39.2 Heat input kw 18 24 32 36.5 Ignition ELECTRONIC Eficiency at nominal output % 89.9 90.2 93.1 93.1 Efficiency at reduced load (30%) % 88.53 89.23 92.08 92.14 Efficiency rating CE Maintaining loss at T = 50 C % 2.5 2.2 1.9 1.5 Heat loss at the chimney with burner off % 0.2 0.2 0.2 0.2 Heat loss at the chimney with burner on % 7.7 7.6 5 5.4 Flue gas temperature (G 20 nat. gas) C 120/130 120/130 110/120 120/130 Flue gas temperature (G 30) C 120/130 120/130 120/130 120/130 Flue gas mass output Kg/h 42 55 67 76 Max. operating pressure bar 4 4 4 4 Water content l 10 10 13.4 13.4 Minimum water flow rate l/h 400 520 690 780 Load loss on the water side w.c.m. 0.4 0.4 0.6 0.6 Maximum hot water temperature C 85 85 85 85 Burner gas pressure (G 20 nat. gas) mbar 9.5 11 9.5 12 Burner gas pressure (G 30) mbar 27 26 25.5 26 Flue gas discharge pipe diameter Ø 100/60 100/60 100/60 100/60 Split pipe diameter Ø 80 80 80 80 Flow pipe diameter Ø 1 1 1 1 Return pipe diameter Ø 1 1 1 1 Gas inlet diameter Ø 1/2 1/2 1/2 1/2 Mains voltage and frequency V/Hz 230/50 230/50 230/50 230/50 Wattage W 50 50 60 60 Dimensions: Width mm 450 450 450 450 Depth mm 510 510 610 610 Height mm 850 850 850 850 Net weight Kg 125 125 160 160 Uff. Pub. Fondital - CTC 03 C 083-03 Maggio 2006 (2.000-05/2006) FONDITAL S.p.A. 25078 VESTONE (Brescia) Italy - Via Mocenigo, 123 Tel. +39 0365 878.31 - Fax +39 0365 820.200 e-mail: info@fondital.it - www.fondital.it