QT50R. R-GAGE QT50R Sensors( 雷達 ) Radar-Based Sensors m 堅固及科技雷達搭配特優的抗環境特性 隧道 涵洞或寬廣 ( 嚴酷 ) 的室外環境的應用 先進的雷達傳感器適用於移動物或靜止物之偵測.

Similar documents
R-GAGE QT50R-AF2W Sensor

R-GAGE QT50R-AFS Sensor

R-GAGE QT50R-AF2 Sensor

R-GAGE QT50R-AF2W Sensor

QT50RAF Radar-Based Sensor

R-GAGE Radar Sensor bannerengineering.com.

MINI-BEAM Expert Series

RAS-DX18HDK/RAC-DX18HDK

M12 Class 1 Laser Emitter

M12 Class 2 Laser Emitter

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

公司願景 業務項目 我們的願景是能為您帶來更加 健康 舒適 便利 的生活環境 水的控制專家 晴立實業 創立於 1993 年 十幾年來致力於排水器及週邊產品之研究與開發 多年來的創新及研發成果獲得多項產品專利, 深受各界的肯定, 於業界亦趨領導地位 為了服務客戶長久以來的支持,

FIBARO FLOOD SENSOR OPERATING MANUAL FGBHFS-101 CONTENTS. #6: Functionalities 8 #7: Configurable parameters 9 #8: Specifications 10 #9: Regulations 11

R-S32EPH R-S32EPHL

PAC-10P PAC-15P. 移動座地式冷暖空調 Portable Reverse Cycle Air Conditioner 在使用之前請詳細閱讀 使用說明書 及 保用條例, 並妥為保存

GPI-M3 USER MANUAL. Instantaneous Electric Water Heater F O R 1 3 A S O C K E T

Port Machinery Sensing Solutions

HTO-124. Oil-Filled Heater USER MANUAL

8 Filtration Systems Air Purifier 8 重過濾空氣清新機 User Manual 產品說明書

VX SERIES Wireless Thermostat with Occupancy Sensor

KTT-109. Foldable Travel Kettle USE R MA NUA L GPU-6SSL GPNB-6SSL. 2-in-1 Free Standing Steam Oven

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

多功能浴室乾衣暖風機系列 靈活安裝 體積纖巧 MULTI-PURPOSE BATHROOM HEATER SERIES 多功能無線遙控. PTC 陶瓷發熱 PTC Ceramic Heating 負離子淨化空氣 三種靈活安裝 全機二年保用 - Y E A R W A R R A N T

Ultrasonic Reflective Sensor

SC8130S /SC8136S /SC8130W /SC8136W SC8830BS /SC8836BS /SC8830BW/SC8836BW SC8130S /SC8136S /SC8130W/SC8136W SC8830BS /SC8836BS /SC8830BW/SC8836BW

KTV-215 真空無線控溫電熱水壺 U S E R M A N U A L 使用說明書. Cordless Temperature Control Vacuum Kettle P.1 在使用之前請詳細閱讀 使用說明書 及 保用條例, 並妥為保存

Long-Range Barrier Sensors

Limitless Wireless Din-Rail Receiver. WDRR Series. Datasheet

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

GAS STAINLESS COOKTOP

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION LIGHT, WARNING, 360 DEGREE LED BEACON PUBLICATION

Smart Home Outdoor Siren

Wireless Panel-Mount Monitor

Vehicle Detection: How To Choose the Right Technology... 3

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Alteration and Addition

Humidity Monitor model 01080

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Remote Relay Module (RRM)

The Future s Now. market SMART HOME

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Quadrature Speed and Direction Sensors

LOUNGER. Manual de instalación 使用手冊. Installation Manual 若遺失任何零件, 請立即停止安裝並與我們聯絡, 來電請撥 : 開始安裝前請詳閱說明 本產品應由具經驗的水電工進行安裝

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

WorkZone PreView Sensor Manual

Ultrasonic Reflective Sensor

Original instructions Sense7-series Non-contact coded safety switch

Operating Instructions Air Conditioner

SS IN 1 SMD HOT AIR REWORK STATION

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Owner s Manual / 使用手冊

CD6102 / CD6102 OC / CD6102-2

Oven toaster EOT3818K EOT5818K

HOBO MX Temp/RH Data Logger (MX1101) Manual

Ammonia Mercerization of Denim 牛仔布液氨絲光. The use of ammonia in mercerization has been known since the 1930 s and was developed

INSTRUCTION MANUAL P Heating and 1 Cooling

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Installation Instructions

Immunity. P/N: ver.b

U5300 Industrial Pressure Transducer

RK-05 Carbon Monoxide Detector Operator s Manual

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

TrueClean ToteCleaner

BSE Public CPD Lecture Adjunct Professor Talk A Gas Passport on 31 May 2010

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

Thermometer with Wired Sensor

DEHUMIDIFIER. User Manual 50BT, 70BT

IFS Fiber Module Installation & Operation Instructions

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Twin Photobeam Detectors Manual

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

USER MANUAL SAVE THESE INSTRUCTIONS

兩個階段的蒸發冷卻系統在炎熱潮濕氣候的應用分析

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

CKF-110. Express Healthy Air Fryer USER MANUAL

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

IFS Fiber Module Installation & Operation Instructions

RK CO 2 Transmitter Operator s Manual

Operating Instructions

IFS Fiber Module Installation & Operation Instructions

Murano Shower Cabin Installation Instruction

Blade Series Heat Exchanger Operation and Installation

M5200 Industrial Pressure Transducer

DIGITAL ARIA FRYER 電子控制無油煎炸鍋 MODEL NO.: GAF W A GILMAN GROUP BRAND

SCB-103. Deluxe Delicacy Cooker USER MANUAL

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

3M Benchtop Air Ionizer 963E. User s Guide

Beacon 800 Gas Monitor Operator s Manual

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

產品安全指引 使用說明及安裝指南. Model : WFCR 產品型號 : WFCR 75230

Radio Frequency Do s & Don ts

Door/Window Sensor Installation Instructions

Long Range Radio Alarm Transmitter

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Transcription:

Radar-Based Sensors The QT50R radar sensor s functions are unaffected by wind, rain, fog,light, humidity and temperature, making it ideal for outdoor environments. Uses Frequency Modulated Continuous Wave (FMCW) to detect moving and stationary objects Easy setup and configuration of range, sensitivity and output with simple DIP switches Retroreflective models use a reference target, enabling reliable detection of weak targets in the foreground Adjustable-field models ignore objects beyond the set point QT50R 12...24m http://www.e-sensors.com.tw the QT50R MODEL 堅固及科技雷達搭配特優的抗環境特性 Family QT50R Telecom Approval US Model RH Connector Q 隧道 涵洞或寬廣 ( 嚴酷 ) 的室外環境的應用 RH =Retro Sensing Max range:12m AFH =Adjustable-field Sensing Max range:24m Q=5-pin Quick-Disconnect 先進的雷達傳感器適用於移動物或靜止物之偵測 R-GAGE QT50R 使用頻率調整波 (FMCW) 雷達可確實的偵測移動中或靜止的物體, 包括汽車 火車 卡車和貨物 它可抵抗嚴酷的天氣,QT50R 對於防雨 防風 防濕和溫度抵抗非常有效的, 並能精確的傳遞被偵測物的存在 缺乏或改變的資訊 能應用於各式天氣的最先進的檢測 - 使用 FMCW 技術來偵測移動和靜止的物體 - 提供被檢測的目標是否存在 缺乏或改變的資訊 - 可檢測特定距離內偵測目標物 忽略在設定點之外的物體和背景 -2.4GHz 的操作可應用於工業 科學 和醫學 電信傳送. - 堅固耐用的 IP67 特色適用於嚴酷的環境. - 可經的起極端溫度的考驗和暴露於強風下 (-40~65 ). - 在 max 24m 內的車輛或移動載具都可以偵測到. - 包含的 DIP 開關適用於檢測距離 靈敏度和輸出排列. - 提供 12 到 30VDC 電壓加上 PNP( 遞增 ) 和 NPN( 遞減 ) 輸出. - 明亮的 LED 指示可簡易了解監測狀態. - 貨物定位和貨車車身檢測 - 停車坡道和車庫門的接近控制 - 得來速的車輛檢測 - 起重機定位檢測 - 車輛檢測和收費亭計算 - 火車 軌道電車檢測和隧道位置檢測 R-GAGE QT50R Sensors( 雷達 ) www.e-sensors.com.tw BI 2

R-GAGE Radar Sensor www.bannerengineering.com 1.888.373.6767 bannerengineering.com

Easy Configuration No PC Required IP67 Vibration Resistant < 1M All-Weather Outdoor Applications Ease of installation No PC required Sunlight Immune Extreme Temperatures Snow, Fog, Heavy Rain & Humidity Strong Wind Plug and play after simple DIP-Switch configuration Maintenance-free Crane Collision Avoidance Entry/Exit Gate & Drive Thru

QT50R Retroreflective Accessories Single sensing zone Range up to 12 meters off of: - BRTR-CC20E retroreflective target - Pavement/road surface Models QT50R-US-RHQ QT50R-UK-RHQ QT50R-EU-RHQ Retroreflective Features 12-30V dc Bipolar NPN/PNP DIP-Switch-selectable N.O. or N.C. 5-pin M12 quick-disconnect models shown. For 5-wire 2 m integral cable versions, remove suffix Q from the model number (e.g., QT50R-xx-RH). Applications Vehicle Detection Use when background is the best reflective target Senses vehicles despite size and shape Detection of flatbed or box trucks at loading dock Overhead sensing of exit lanes when multiple lanes exist SMBWSQ120 Heavy-duty, rear-mount protective metal enclosure for use with Q120RA model Supports both horizontal and vertical sensor mounting 16-gauge 304 stainless steel Keeps rain and ice off the face of the sensor BRTR-CC20E Retroreflective target for use with QT50R retroreflective model Large corner-cube reflector in protective plastic enclosure QT50RCK Weather deflector Small hood keeps rain and ice off the face of the sensor Includes mounting hardware SMB30SC Split clamp with swivel bracket with 30 mm mounting hole for sensor Black reinforced thermoplastic polyester Stainless steel mounting hardware included SMB30MM 12-gauge stainless steel bracket with curved mounting slots for versatile orientation Mounting hole for 30 mm sensor NOTE: Sensor face must be kept free of heavy water and ice build-up. Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 (763) 544-3164 Fax: (763) 544-3213 Toll-free: 888-373-6767 www.bannerengineering.com Email: sensors@bannerengineering.com PN 135780 rev. A

Datasheet Radar-Based Adjustable Field Sensors for Detection of Moving and Stationary Targets FMCW (true-presence) radar detects moving and stationary objects Adjustable sensing field ignores objects beyond setpoint Easy setup and configuration of range, sensitivity, and output with simple DIP switches Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air temperatures, or light Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication band Rugged IP67 housing withstands harsh environments Protected by US patents Models Models 1 Maximu m Range Connection Supply Voltage Telecom Approval 2 Output QT50RAF-US Telecom approved for US, Canada, and Brazil QT50RAF-CN QT50RAF-EU 15 m (49 ft) 5-wire 2 m (6.5 ft) Integral cable 12 to 30 V dc Telecom approved for China Telecom approved for Europe (except UK), Australia, New Zealand, China, and Japan Bipolar NPN/PNP; DIPswitch-selectable N.O. or N.C. QT50RAF-UK Telecom approved for UK CAUTION: Make No Modifications to this Product Any modifications to this product not expressly approved by Banner Engineering could void the user's authority to operate the product. Contact Banner Engineering for more information. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. 1 Cabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect fitting, add suffix "Q" to the model number (e.g., QT50RAFQ-xx). QD models require a mating cordset. 2 For additional countries, contact Banner Engineering. Original Document 135460 Rev. F 19 February 2015 135460

R-GAGE QT50RAF Sensor Overview The R-GAGE sensor emits a well-defined beam of high-frequency radio waves from an internal antenna. Some of this emitted energy reflects back to the receiving antenna. Signal processing electronics in the sensor determine the distance from the sensor to the object based on the time delay of the return signal. The sensor can be configured (via DIP switches) to sense objects up to a specific distance, ignoring objects beyond this distance (also called background suppression). Setpoint Figure 2. R-Gage Features X Y 1. Power LED: Green (power ON) 2. Signal Strength LED: Red (flashes in proportion to the signal strength) 3. Output LEDs: Yellow (output energized); Red (configuration) D Figure 1. R-GAGE Setpoint Access the DIP switches behind the threaded cap on the sensor back (not shown) R-GAGE setpoint distances, minimum and maximum (sensor will detect objects up to setpoint and ignore objects beyond the setpoint) EU, CN Models US, UK Models X Minimum setpoint distance 2 m (6.6 ft) 3 m (9.8 ft) Y Maximum setpoint distance 15 m (49.2 ft) 15 m (49.2 ft) D Dead Zone3 Sensor Configuration The sensing zone distance, sensitivity, and output configuration can be selected via the DIP switches on the back of the sensor. Use the included spanner to open the screw-off cover on the back of the sensor and access the DIP switches. Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight seal. DIP Switch Functions Switch Function 1, 2, 3 Sensing distance (detects objects from sensor face to this point) 4, 5, 6 Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern) 7 Normally open/normally closed output functionality 8 Response Speed DIP switch 1 is on the left and DIP switch 8 is on the right. 3 Typical dead zone: 0.4 m (1.3 ft) for moving and 1.0 m (3.3 ft) for stationary targets, but varies with target reflectivity 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 135460 Rev. F

Distance Settings Switch 1 Switch 2 Switch 3 Distance EU, CN Models US, UK Models 0 0 0 2 m (6.6 ft) 3 m (9.8 ft) 0 0 1 3 m (9.8 ft) 4 m (13.1 ft) 0 1 0 4 m (13.1 ft) 5 m (16.4 ft) 0 1 1 6 m (19.7 ft) 6 m (19.7 ft) 1* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft) 1 0 1 10 m (32.8 ft) 10 m (32.8 ft) 1 1 0 12 m (39.4 ft) 12 m (39.4 ft) 1 1 1 15 m (49.2 ft) 15 m (49.2 ft) * Default settings NOTE: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less Sensitivity Selection Switch 4 Switch 5 Switch 6 Sensitivity 0* 0* 0* 8 (Highest) 0 0 1 7 0 1 0 6 0 1 1 5 1 0 0 4 1 0 1 3 1 1 0 2 1 1 1 1 (Lowest) * Default settings NOTE: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and not to narrow the beam width. Narrow-beam R-GAGE sensor models are available. Output Configuration Switch 7 Normally Open/Normally Closed 0* N.O. 1 N.C. * Default settings Response Speed Switch 8 ON OFF ON/OFF 0 32 ms 68 ms 100 ms 1* 258 ms 998 ms 1256 ms * Default settings P/N 135460 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 3

Specifications Range The sensor is able to detect a proper object (see Detectable Objects) from 1 to 15 m (3.3 to 49.2 ft), depending on target Detectable Objects Objects containing metal, water, or similar high-dielectric materials Operating Principle Frequency modulated continuous-wave (FMCW) radar Operating Frequency 24.00 to 24.25 GHz, ISM Band (varies slightly with model, depending on national telecom regulations) Supply Voltage 12 to 30 V dc, less than 100 ma, exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient over-voltages Delay at Power-up Less than 2 seconds Output Configuration Bipolar NPN/PNP output, 150mA; DIP switch 7 selects N.O. (default) or N.C. operation Output Protection Protected against short circuit conditions Response Time DIP switch 8 selects ON/OFF response time Indicators Power LED: Green (power ON) Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at 4x excess gain. Only indicates signal amplitude, not target distance. Output LEDs: Yellow (output energized) / Red (configuration) See Figure 2 on page 2 Adjustments DIP-switch-configurable sensing distance, sensitivity, response time, and output configuration Construction Housing: ABS/polycarbonate Lightpipes: Acrylic Access Cap: Polyester Operating Temperature 40 C to +65 C ( 40 F to +149 F) Environmental Rating IEC IP67 Connections Integral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD fitting. QD models require a mating cordset Certifications ETSI/EN 300 440; FCC part 15; RSS-210; ANATEL Category II; CMIIT Category G; ARIB STD T-73; for others, contact Banner Engineering. Country of Origin: USA FCC ID: UE3QT50RUS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Este equipamento opera em caráter secundário, isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Windows The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window. Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials. Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the window. Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance without issue. Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric boundary. 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 135460 Rev. F

Beam Pattern Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m 2 ) Left-Right Beam Pattern Typical Beam Pattern (with 4 different targets) at highest sensitivity level Left-Right Beam Pattern 15 m 8 m 10 m 6 m 5 m 4 m 0-5 m 1 6 7 2 3 4 5 8 2 m 0-2 m 1 2-10 m -4 m -6 m 3-15 m 0 5 m 10 m 15 m 20 m 25 m 30 m 4-8 m 0 4 m 8 m 12 m 16 m Distance Distance 1 8: Indicates sensitivity level 1: Weak Object (Radar cross section = 0.25 m 2 ) 2: Car (Radar cross section = 3 m 2 ) 3: Large Truck (Radar cross section = 50 m 2 ) 4: Passenger Train (Radar cross section = 300 m 2 ) NOTE: The effective beam pattern depends on the sensitivity level and target properties. Dimensions 46.1 mm (1.82") 38.1 mm (1.50") 37.0 mm (1.46") 74.1 mm (2.92") 4X Ø4.4 mm (Ø 0.17") 33.0 mm (1.30") 66.0 mm (2.60") 50.8 mm (2.00") 19.7 mm (0.78") R45.0 mm (R1.77") 37.0 mm (1.46") 34.2 mm (1.35") M30 X 1.5 ISO-6g 50.8 mm (2.00") P/N 135460 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 5

Hookup Wiring Key: 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray (Do not connect) NOTE: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc common. Shielded cordsets are recommended for all QD models. Quick Disconnect (QD) Cordsets 5-Pin Threaded M12/Euro-Style Cordsets with Shield Model Length Style Dimensions Pinout (Female) MQDEC2-506 MQDEC2-515 1.83 m (6 ft) 4.57 m (15 ft) 44 Typ. MQDEC2-530 MQDEC2-550 MQDEC2-506RA MQDEC2-515RA MQDEC2-530RA 9.14 m (30 ft) 15.2 m (50 ft) 1.83 m (6 ft) 4.57 m (15 ft) 9.14 m (30 ft) Straight Right-Angle 32 Typ. [1.26"] M12 x 1 2 ø 14.5 1 3 4 5 30 Typ. [1.18"] 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray MQDEC2-550RA 15.2 m (50 ft) M12 x 1 ø 14.5 [0.57"] NOTE: Pin 5 is not used. Mounting Brackets All measurements are in mm SMB30SC Swivel bracket with 30 mm mounting hole for sensor Black reinforced thermoplastic polyester Stainless steel mounting and swivel locking hardware included 58 29 67 A B SMB30MM 12-ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 30 mm sensor 57 70 A B C 57 Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1 6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 135460 Rev. F

Weather Deflector QT50RCK Required if the R-GAGE is exposed to rain or snow Prevents buildup of water or ice from interfering with sensor performance Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. www.bannerengineering.com - Tel: +1-763-544-3164