HVAC - Central System Thermal Storage

Similar documents
Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

THERMAL ICE STORAGE: Application & Design Guide

INTEGRATED SOLUTIONS BY ICE-CEL. Tube-In-Tank Ice Thermal Storage Systems. Products that perform...by people who care.

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)

New PHE applications in construction & HVAC.

Air Conditioning Clinic

HVAC Water chiller selection and optimisation of operation

General HVAC Recommendations

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

ASHRAE JOURNAL ON REHEAT

A REVIEW ON GREEN TECHNOLOGY IN HVAC

Falling Film Chiller. water down to 0,5 C

ICE CHILLER Thermal Storage Products... F2. Benefits... F4. Proven Technology... F7. Construction Details TSU-M - Internal Melt Application...

SOLAR HOT WATER HEATERS

Air-Cooling Evaporators

MECHANICAL SERVICES 101. Ian White

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

Partial Load Performance Of Refrigeration System

Closing the Loop What s best for your system?

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Energy-Saving Industrial Water Chillers

Best Practices for Condensing Boilers

Energy Efficiency Considerations in Refrigeration Systems

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AIR TO WATER. Heat Pumps & Chillers

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

SINGLE STAGE MULTI STAGE NANO MICRO

MACH N-407 Heat Pump Air-Cooled Chiller

The cold chain in the fishery sector. Refrigeration Technology Review

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

The Benefits Really Add Up

Binoe E. ABUAN, Menandro S. BERANA, Ruben A. BONGAT. University of the Philippines Diliman, Quezon City, Philippines

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Polaris PHEs vs. Shell-and-Tube Exchangers

SYSTEM DESIGN REQUIREMENTS

PPL Electric Utilities Energy Efficiency and Conservation Program

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

PACKAGED AIR COOLED Product Data Catalog

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

MAC N-407 Air-Cooled Chiller

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

How to Select and Size a Chiller

solar thermic system Solar thermic systems are devices that allow you to capture and store solar energy for later use in various utilization.

Cool Savings Program Report

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

AHRI Certification Program Scopes - COOLING

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

Precise Temperature Control; Compact Footprint

Daikin Blueprint: Delivering Hot Water with a Chiller

C o o l i n g a n d h e a t i n g s y s t e m s

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Heat Pump Water Heaters

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

Wal-Mart HE.5 Supercenter

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

August 15, 2013 Page 1 of 19

Owner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 )

Table of Contents. 2 aermec.us

Part IV: Flow Side Components Flow Diagram

USER S GUIDE. For all Packaged Systems (Air Conditioners and Heat Pumps)

Modular Active. Chilled. Beams

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

Parilla Thermal Storage Project Case Study. May Page 1 of 11

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Unico Training. Welcome to Unico!

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

CONTENTS. B. System Design and Performance Requirements

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

July 2012 was a significant date for the HVAC and Refrigeration industry as it saw the introduction of the Carbon Tax and the HFC Levy.

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

PACKAGED REFRIGERATION EQUIPMENT

Vicot Air Conditioning Co., Ltd. CONTENT

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Energy Recovery Ventilation

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

energydesignresources

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

Surna 25-Ton Chiller Operating & Maintenance Manual

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

Energy efficient vacuum freezing ice slurry generation using a R718 compressor

COMMERCIAL PRODUCT LINE

Here Is A Crash Course in geothermal heat pumps!

Environmentally friendly refrigeration systems for industrial use

INSTANT CHILLER. Chester-Jensen Co., Inc. Unit Construction and Short Gas Flow

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

gforce Units Data Aire and Data Temp Series

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Product Introduction...F2. Benefits...F4. Proven Technology...F8. Construction Details...F12. Engineering Data...F14. Custom Coils...

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Method to test HVAC equipment at part load conditions

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Transcription:

HVAC - Central System Thermal Storage General Thermal storage is a cost saving technique, and in some cases, energy saving technology. Commercial cooling can account for as much as 40% of peak demand on a hot summer day. Cool storage can shift some or all of the on-peak demand to offpeak hours. With cool storage (chilled water or ice storage), cost is saved by: Reducing electric demand charges through decreasing or eliminating chiller operation during peak demand periods; Operating chillers at night and displacing energy use from peak to off-peak periods when the energy is at a lower cost. Hot water storage for domestic service water is a common example. It assures a supply during peak occupant demand times, and reduces cost in the same manner as cool storage. Storing hot water for space heating is less common, except where electric energy is used for heating. Advantages There are a number of advantages for end-users and utilities. Users gain by reducing their utility bills - largely through peakshaving; reduced equipment size, space and weight; reduced compressor kw due to operating at more hours at full load and at nighttime lower condensing temperatures; availability of cold air distribution when ice is used; possible backup cooling or heating redundancy in event of power failure; when chilled water storage is used, availability of an added fire-protection water source.

Disadvantages Applications The utilities can gain from reduced peak use, improved load factors, added off-peak sales, deferred peak-capacity expansion costs, and improved competitive position over gas-fired alternatives. May increase first cost of HVAC system; More complicated system design; Requires well-trained maintenance crew; Possible ambient heat gain to storage tanks; Specifying engineer has little incentive to use as it costs more to design and the firm may have little or no experience with the technology; Some of the risks include night-time loads greater than planned, insufficient storage provided so on hot days demand is not saved, improper controls supplied, operator inattention or unskilled, condensation on ducts with low temperature supply air when a fan is out of service. Cooling, not heating, is a main concern of commercial building owners. Many buildings are populated with people, heat-emitting office and production equipment, and ample lighting -- all generating so much heat that cooling is required during most of the working hours all year. Most of these hours occur during the peak hours defined by the electric rate structure. Cool storage can shift all or most of this use to lower-cost off-peak hours resulting in lower operating cost without sacrificing comfort...and in some cases, increasing comfort. The best cool storage applications are in any building: being charged on a time-of-use electric rate schedule; having high on-peak demand charges, with relatively low or no offpeak demand charge; that has peak cooling loads during utility on-peak hours; has very few comfort or process cooling hours per day, week or month, but with high peak loads during those few hours (such as churches); requiring low humidity control where ice storage can be used.

Air conditioning applications that can best benefit are office buildings, schools and college buildings, religious institutions, laboratories, large retail stores, libraries, museums, and the public use areas (meeting rooms, exhibit halls, convention centers) of hotels and public assembly buildings. Other applications include: Industrial processes with batch cooling requirements; Facilities where low humidity can be achieved with the low water temperature achieved from ice storage; Buildings where space is at such a premium that the small ducts used with low air temperature distribution are advantageous, such as retrofit of older, historic buildings; Facilities where the cold storage can be tied into existing ammonia or other refrigeration systems. There are some applications which may seem to be cool storage candidates, but should be avoided if these conditions exist: Technology Types No benefit from off-peak operation; Speculative designs built on low-first cost premises; Likelihood of little or no attention to providing and keeping trained operators; Seasonal projects where the staff changes from season to season. Depending on the needs of the building or process and the electric rate structure, there are several types of cool storage designs that may be employed on a given project: Full storage (load shifting)- discharging stored capacity without any concurrent chiller operation; Partial storage (load leveling)- discharging storage to meet cooling loads with concurrent operation of some chiller(s) piped in parallel with storage); Full recharge - recharging storage with chiller operation; Partial recharge - recharging storage with chiller capacity while simultaneously providing capacity to the cooling load;

Standby - no normal use of storage, with chillers serving the cooling loads as they would in the absence of storage. Storage used when power outages occur. Storage capacity is usually defined in ton-hours which is the sum of the actual tons required each hour for the design day. It can be achieved using either chilled water storage or ice storage. Chilled water storage typically requires more space (25 to 50 liters per m 2 of conditioned space) than ice storage (3 to 6 liters per m 2 ). Chilled Water Storage Chilled water storage is most common on very large projects (typically over 5 000m 2 ) where ample space is available. The steel or concrete tank(s) can be located either above- or below-ground. In some cases, the stored water can serve to provide some or all the fire protection water storage. The complexities of assuring thermal stratification make chilled water storage more attractive where the storage tank is very large (and deeper than about 6m). Adding chilled water storage is also an option for an existing facility to meet immediate growth needs while postponing new chiller acquisitions.

Ice Storage There are two basic types - Ice Building Systems (static systems) and Ice Harvesting Systems (dynamic systems). The main advantage of ice storage is that it requires less space, can provide colder air to the building, and reduces duct and fan size; with an offsetting disadvantage of consuming more chiller energy. Ice storage, being more compact, is most common on smaller commercial buildings or where space for the storage is limited. Ice storage systems, while requiring more refrigeration, can produce lower temperature chilled water, enabling the use of smaller chilled water pumps, piping, and coils. In general, static systems are more compact, simpler, and less costly than dynamic systems. As a result, static or Ice Builder systems seem more popular. The most prevalent ice storage systems are: Ice on coil in an open water side system (requires some periodic water treatment); Ice on coil using brine in a closed (pressurized) water side system, and Ice maker systems (ice harvester including spray-slush-ice). Other system types (such as encapsulated ice, icefalls, eutectic salt storage) are variations being developed and commercialized. Ice on Coil Systems Open System - Cold refrigerant or a brine solution is circulated through pipe coils submerged in an open water tank as shown below. During the charge cycle, ice forms on the pipe coils until a satisfactory thickness (typically 2" to 3") is achieved. During normal operation, chilled water is circulated to the load, and the ice remains in storage. During the discharge cycle, the chilled water flows through the storage tank(s) and is chilled by the melting ice. Where a closed circulating system is required, a heat exchanger is used between the circulating ice water and building chilled water as shown in the following:

Closed System - Another popular variation is the modular ice storage system using glycol brine. This system utilizes one or more polyethylene tanks and tubes. Cold brine in a closed circulating system flows in a counter flow arrangement through the tubes, freezing the water in the tanks. In the charge cycle, an automatic diverting valve bypasses the cooling coils and the refrigerated brine builds ice. Ice Maker Systems - These are typically either a dynamic ice harvester or a spray slush-ice system.

Dynamic ice harvesters use a water supply and refrigerated plates or tubes suspended over the storage tank. Ice forms on the refrigerated surfaces and is periodically ejected into the storage tank. Spray slush-ice systems are similar except use a water/glycol solution and refrigerated tubes to generate an icy slush. Glycol Storage Glycol systems freeze water by circulating ethylene or propylene glycol through storage tanks.

The glycol ice storage system is very simple. Few accessories are needed, and conventional water chillers are used. Instead of water, a glycol solution (in this case, 25% ethylene glycol) is - pumped through the chiller, coils and ice storage tanks in the chilled water loop. The -4 to -5 C ethylene glycol produced by the packaged chiller freezes the water contained inside the ice storage tanks. Advantages: Glycol ice storage systems present the system designer with numerous benefits. First is the ability to use a standard packaged chiller. They offer an opportunity to reduce pump horsepower, and they require few accessories. The choice of either modular storage tanks or encapsulated ice systems not only offer application flexibility, but costs and reliable performance as well. Simple control schemes can be used, and like all ice storage systems - volume and space requirements per ton-hour of storage are considerably lower than those for chilled water storage. Glycol ice storage systems enjoy a low installed cost since the same packaged chiller that provides space cooling also doubles as the "ice maker." The storage tanks themselves are the only significant cost burden of these systems. In fact, glycol ice storage systems may yield reduced chiller costs. Disadvantages: Glycol ice storage systems are not without their problems. The most significant of these is the need to design a heat transfer system that uses ethylene (or propylene) glycol rather than water.