Spark Electrodes/Flame Sensors For Gas Ignition Systems July 2016 DESCRIPTION Fenwal electrodes and sensors are an integral part of the ignition system for gas-fired equipment and ensure reliable ignition, optimal performance and long service life over a wide range of operating conditions. Fenwal uses only high-quality materials such as glazed Alumina ceramics and certified rod materials suitable for up to 2175 F (1190 C). Fenwal electrodes are RoHS compliant and CSA certified. Design, configuration and application are key factors in selecting the proper electrode. Rely on Fenwal's experience to provide our full range of gas ignition controls and accessories for your gas-fired equipment application. Spark electrodes typically have a 0" ±.03 gap between the high voltage (HV) rod tip and the ground rod or burner. To facilitate consistent sparking, the gap should be from a sharp edge to a sharp edge. Position this "spark gap" at the optimal location in the burner for reliable lighting of the gas. IMPORTANT: High efficiency and modulating-condensing appliances may use mesh burners. These often use larger spark gaps and may need special consideration in the system design. Consult FENWAL CONTROLS for guidance and best practices. Proper location of electrode assembly is important for optimum system performance. The electrode assembly should be located so that the tips are inside the flame envelope and about 1/2-inch (1.2 cm) above the base of the flame as shown below. Flame sensors are single rods used in the flame rectification circuit of the ignition control to confirm the presence (or absence) of flame. Position this sensor so that it is well exposed to the flame over some length (not just the tip) to reliably complete the flame safeguard circuit. In Local Sense, or "spark and sense" systems, the HV electrode rod performs both spark and sense functions. For Remote Sense systems, a separate rod is used to sense the flame, which may be placed remotely from the spark electrode, or integrated with it on the same mounting bracket. Please refer to pages 2-15 for a wide range of designs that are in production and available for sampling. Please contact your local sales representative or Sales Manager for samples, or detailed dimensions on any electrode of interest. Fenwal can provide custom design electrodes to meet your appliance or burner application for annual volumes 2000. Ceramic insulators must not be in or close to the flame. Electrode assemblies must not be adjusted or disassembled. Electrodes are NOT field-adjustable. Electrodes should have a gap spacing of 0± 0.031 in (3.12± 0.81 mm), unless otherwise specified by the appliance manufacturer. If spacing is not correct, the assembly must be replaced. Exceeding temperature limits can cause nuisance lockouts and premature electrode failure. Electrodes must be located where they are not exposed during normal operation. IMPORTANT: Always ensure a good ground path that matches burner ground to control ground. Consult FENWAL CONTROLS with any questions or to confirm best solutions for your Ignition problems.
SINGLE ROD ELECTRODES/REMOTE FLAME SENSE RODS Note: All dimensions featured in the following figures are in inches. 22-100001-062 3.468 C L 1.703 1.094.203 22-100001-225 3.000.863.395 Ø.166 22-100001-334 2.250 AMP Terminal 26.000.600.468 UL Style Wire 1.000 2
SINGLE ROD ELECTRODES/REMOTE FLAME SENSE RODS (CONTINUED) 22-100001-352 MAX. 6 22-100001-390.283.838 C L Ø.212 4.650 2 3 1.627.684.419.138 3
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES 22-100000-555 1 1.406.421.297.218 2 QC Male Terminals.250 X.032 22-100000-663 1.812.364.438.325 1.489 1.350.437.062.173 22-100000-664.344.577.270.203 1.094.703 1 Ø.172.031 1.829 4
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES (CONTINUED) 22-100000-673 1 3 1.000 2.188.218 3.250 1 Rajah Terminal Ø.085 Wire 22-100001-012 3.000.625 22-100001-045.850 2.437 5
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES (CONTINUED) 22-100001-100.437 1 1.862.550 22-100001-108 2.781.437 22-100001-117 2.250 1.215 2.295 Ø.208 4.000 6
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES (CONTINUED) 22-100001-120 2.845 MAX. 1.438 1.468.437 1 22-100001-182 1.827 Ø.208.031 MAX..437 2.669 1 7
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES (CONTINUED) 22-100001-211 3.138.530 2.250 1.000 1.575 Rajah Terminal Ø.208 22-100001-261 2.700 MAX..344 1.800 1.703 1.094 Ø.172 1.176 1.400 Rajah Terminal 8
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES (CONTINUED) 22-100001-333 1.625 Ø.175 1.437 Ø.359 2 Ø 22-100001-365 2.530 2.250 1.000.937 Ø.208 Rajah Terminal 9
TWO ROD ELECTRODES/SPARK AND SENSE ELECTRODES (CONTINUED) 22-100001-372.175..140.265.637.437.470.677 1.880.230 Ø.175.230.440 1.580.880 2.030 Rajah Terminal 2.294 22-100001-389 1.190.220 Ø.290 2.385 1.275 1.896 2.859.600 3.000.005 1.180.063.472.220.890.220 Rajah Terminal 10
THREE ROD ELECTRODES/SPARK ELECTRODES WITH INTEGRAL REMOTE FLAME SENSE ROD 05-100000-411 1 Ø.093 Ø 1 1 QC Male Terminal X.032 1 05-100000-422 Ø.093 Ø.625 3.000 3 1 QC Male Terminal X.032 1 11
THREE ROD ELECTRODES/SPARK ELECTRODES WITH INTEGRAL REMOTE FLAME SENSE ROD (CONTINUED) 22-100000-593 6.000 2 QC Male Terminals X.032 22-100000-630 3 3.005.625.782.208 3.212 3.968 1 1 QC Male Terminal X.032 12
THREE ROD ELECTRODES/SPARK ELECTRODES WITH INTEGRAL REMOTE FLAME SENSE ROD (CONTINUED) 22-100001-113 1.355 1.938 2.086 1 QC Male Terminal X.032 1 22-100001-237 3 1 1 1 QC Male Terminal X.032 1 13
THREE ROD ELECTRODES/SPARK ELECTRODES WITH INTEGRAL REMOTE FLAME SENSE ROD (CONTINUED) 22-100001-292.208 4 8.250 2 3.250 1 QC Male Terminal X.032 1 22-100001-350 2.312 2 MAX..208 DIA. 1.650 MAX. 1 QC Male Terminal X.032 1 Rajah Terminal 14
THREE ROD ELECTRODES/SPARK ELECTRODES WITH INTEGRAL REMOTE FLAME SENSE ROD (CONTINUED) 22-100001-366 3 2.100 1.850 1.380.208 DIA. 3.250 1.576 3.312 1 QC Male Terminal X.032 1 Rajah Terminal 22-100002-076 1 MAX. 5.000 Ø.208.186 1 QC Male Terminal X.032 1 15
FENWAL and DETECT-A-FLAME are registered trademarks of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Fenwal Controls, Kidde-Fenwal, Inc. 400 Main Street Ashland, MA 01721 Tel: 800-FENWAL-1 Fax: 508-881-7619 www.fenwal.com This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. 2016 Kidde-Fenwal Inc. P/N Rev AC