LAE10 LFE10. Use. Series 02

Similar documents
Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

UV Flame Supervision System

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. Building Technologies Division Infrastructure & Cities Sector

C Note! LGI16... Burner Controls. Building Technologies

LGA... Gas Burner Controls. Building Technologies Division

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Use. The burner controls are certified to EN 230 and EN 298.

Infrared Flame Detectors

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Infrared Flame Detectors

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Building Technologies Division

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

QRA10... QRA53... QRA55...

Building Technologies

Burner controls. Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies HVAC Products

LFL Series Burner Flame Safeguard Control

QRA10... QRA53... QRA55...

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

EUROBOX SERIES TYPES CM... SM... MM...

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Forced draught gas burner

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

QRA10... QRA53... QRA55...

EUROBOX SERIES TYPES CM...N SM...N MM...N

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Oil Burner Controls LOA3... Building Technologies Division

Gas Burner Controls. Building Technologies HVAC Products

MMG Gas burner safety control

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

Burner Controls. Building Technologies HVAC Products

EUROFLAT SERIES TYPES C... S... M...

MMI (40-34) Gas burner safty control

Basic unit with integrated air-fuel ratio control for forced draft burners

Burner Management System

QRA10... QRA53... QRA55...

MICROFLAT SERIES TYPES C.../U T X

Gas burner automatic safety control MMI / 811.1

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

UV - flame detector dual fuel burners for intermittent burner operations

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Blue-flame Detectors

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Eclipse 90 UV Scanner Model A Version 1

Program module for burner control LME71.000

CATALOGUE PRODUITS - CSA - CSI - CSM - CSS - CSS2 - P16 - P19 - P20 - P25 - UV DETECTOR

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

RAR... Photocell Detectors. Building Technologies Division

Burner Management System

VeriFlame CE Burner Monitoring System

FIREYE FLAME SAFEGUARD CONTROLS DESCRIPTION

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Forced draught gas burner

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

MBCE-110/230FR Flame Sensor Module

DATASHEET. Burner control unit FDA 601x

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

Eclipse Self-Check UV Scanner

MBCE-110/230UV Flame Sensor Module

Gas Burner Safety Control DMG 970

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Burner control unit BCU 370

Burner Management System

Distributed By: M&M Control Service, INC

for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Flame detector FD 2011 / FD 2012

MBCE-110/230FR Flame Sensor Module

Operator: Save these instructions for future use!

LC3000 Level Controller Installation and Maintenance Instructions

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Use. Functions. Key function. Other functions

Old documentation - Only for your information! Product is not available anymore!

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Product Range Overview

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

SGU 930 SGU 930i. Control box

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

BENSON LINEAR RADIANT TUBE

DIGITAL BURNER CONTROLLER DBC2000 SERIES

Transcription:

ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit, etc. - at least one controlled shutdown is required every 24 hours. For flame supervision systems for continuous operation, refer to data sheet 773. The LAE is used for the supervision and indication of oil flames, the L for gas and oil flames. The LAE / L and this data sheet are intended for use by OEMs which integrate the flame safeguards in their products. Use The LAE is designed for the supervision of oil flames in connection with selenium photocell detectors RAR... The L is suited for the supervision of gas flames and luminous or blue-burning oil flames in connection with UV detectors or a flame rectification probe. Both types of flame safeguards are used primarily in conjunction with the LEC burner control on the following applications: Dual-supervision of burners Supervision of the main flame or of the pilot and main flame by two identical or different types of flame detectors Supervision of forced draught oil / gas burners Supervision of the flame with different types of detectors, depending on the operating mode Multi-flame supervision Plants with several burners whose flames must be supervised individually by one or several detectors, whose startup and supervision, however, should or must be carried out centrally and simultaneously by only one burner control The flame safeguards can also be used in connection with other types of burner controls provided the given combination and selected circuitry do not impair the burner control s safety functions The flame safeguards are also used as flame indication units in combustion plant with manual startup Landis & Staefa Division CCN77E June 0, /

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! It is not permitted to open, interfere with or modify the units! Before performing any wiring changes in the connection area of the LAE / L, the flame safeguard must be completely isolated from the mains supply! Check the wiring and all safety functions! Engineering notes Mounting notes Installation notes Mechanical design Special features Ensure that the drop out delay time of relay «d» does not exceed 50 ms (also refer to «Connection examples»)! The relevant national safety regulations must be complied with! Locate the ignition and detector electrodes such that the ignition spark cannot arc over to the detector electrode! Risk of electric overloads Locate and adjust the flame detector such that only the flame to be supervised will be detected Protect the UV cell adequately against UV radiation emitted by halogen lamps welding equipment special lamps ignition sparks high energy x-rays and gamma rays Installation and commissioning work may only be carried out by qualified staff! Observe the permissible lengths and shielding of the detector cables! Refer to «Technical data»! Always run the ignition cables separate from the unit and other cables while observing the greatest possible distances! Before putting the flame safeguard into operation, check the wiring carefully! The LAE / L are of plug-in design and consist of power section, flame signal amplifier, flame relay, an auxiliary relay for controlling the UV detector or the flame simulation test, and a flame indication lamp located in the unit cover behind a viewing window. The electrical circuit is intrinsically safe in compliance with the relevant regulations and - in connection with LEC burner controls - is tested in respect of proper functioning each time the burner is started up. The flame safeguards can be mounted in any position directly on the burner, in control panels, or on the front of a panel. There are two types of plug-in bases available, designed for cable entry from the front, the side or below. Two earth terminals provide looping facilities for the earth connections of other burner plant components such as ignition transformers (the flame safeguards themselves are double-insulated!). The plug-in bases - like the housing - are made of impact-proof and heat-resistant plastic. For illustrations of the bases and other notes, refer to «Base versions» and «Dimensions». LAE: Automatic light simulation test by increasing the sensitivity of the amplifier during the burner off and purge times, as programmed by the LEC burner control L: Automatic testing of the UV detector by increasing the operating voltage of the UV tube during the burner off and purge times, as programmed by the LEC burner control 2/ CCN77E June 0, Landis & Staefa Division

Flame detectors Technical data UV detector (refer to data sheet 772) Selenium photocell detectors RAR7 and RAR (refer to data sheet 773) Flame rectification probe Flame supervision by making use of the electrical conductivity of the flame in conjunction with the rectifying effect is only possible with gas and blue-flame burners. Since the flame signal amplifier responds only to the d.c. component of the flame signal (ionization current), a short-circuit across the detector electrodes cannot simulate a flame signal. CE conformity Mains voltageac 220 V -5 %...AC 240 V % According to the directives of the European Union AC 0 V -5 %...AC V % Electromagnetic compatibility EMC / 336 EEC incl. 2 / 3 EEC Mains frequency 50...60 Hz ±6 % Directive for gas appliances 0 / 36 EEC Low voltage directive 73 / 23 EEC Prefuse (external) max. A (slow) Environmental conditions Power consumption 4.5 VA Transport IEC 72-3-2 Climatic conditions class 2K2 Max. contact rating 2 A Temperature range -20...60 C Humidity < 5 % r.h. Degree of protection IP 40 Mechanical conditions class 2M2 provided cable entry is in Operation IEC 72-3-3 compliance with IP 40 Climatic conditions class 3K5 Temperature range -20...60 C Mounting orientation optional Humidity < 5 % r.h. Condensation, formation of ice and ingress of water are not permitted! LAE L Weight without plug-in base 305 g 35 g Weight with normal plug-in base 30 g 470 g Weight with high plug-in base 45 g 505 g Flame supervision Series 02 L L LAE Rectification probe UV detector Selenium cell Required min. detector current in µa - At AC 0 V and AC 220 V min. 50 - At AC V and AC 240 V min. 200 Max. possible detector current in µa - At AC 0... V and AC 220...240 V approx. 0 approx. 650 approx. 25 Perm. length of connecting cables 20 m ¹) 20 m ¹) 20 m ²) ¹) In case of greater distances, use low-capacitance cable (total max. 2 nf), such as single-core RG62 ²) Run detector cables separately, at least 5 cm away from other cables and, in case of greater distances, use selenium photocell detector RAR Measurement circuits M - L A - M - L A C - LAE M - 77a07/ A C M Illumination of flame Electrolytic capacitor 0 µf, DC V Detector electrode Microammeter UV detector Ignition may affect the ionization current! Remedy: exchange the connections on the primary side of the ignition transformer Landis & Staefa Division CCN77E June 0, 3/

Function Basic mode of operation of the flame safeguards in connection with the LEC burner control When used with the LEC, the flame safeguard feeds the flame signal into the burner control's control program the same way as if the flame safeguard was a component of the burner control (same as with an oil or gas burner control). In the event of non-ignition, loss of flame during burner operation, or faulty flame signal during burner off or purge times, the burner will always be shut down and the burner control will initiate lockout. The switching functions needed to feed the flame signal into the burner control's control circuit are provided by flame relay of the flame safeguard and the two auxiliary relays «HR» and «HR2» of the LEC burner control. The LEC also delivers the program for the flame simulation test in connection with the LAE, and the UV detector test with the L. The tests are controlled via the connecting line between terminal 5 of the burner control and terminal 6 of the respective flame safeguard. Both tests start about 7 seconds after a controlled shutdown are continued during burner off times are continued during the ensuing pre-purge time end 3 seconds before the start of the safety time Any flame signal detected during this test time, caused by extraneous light ageing UV detectors other defects of the flame supervision equipment, leads to lockout with interlocking of the LEC burner control. In the flame safeguard, the switching functions required are performed by auxiliary relay «HR3». Since in the case of flame supervision with a flame rectification probe, it is not necessary to carry out a test, the connecting line between terminal 5 of the burner control and terminal 6 of the flame safeguard is not required here. Instead, terminal 6 must be connected to the live wire. For example: by making a connection to terminal, 5 or 7. Any flame signal be it a normal flame signal during operation or a faulty signal - is indicated by the indication lamp on the flame safeguard. 4/ CCN77E June 0, Landis & Staefa Division

Mode of operation of the flame safeguards when used for dual-supervision Dual-supervision (detailed connection diagram, e.g. for oil burners) Z OV OV2 77a0/ 2 LAE 2 LAE RAR... RAR... With this type of supervision, one flame is supervised by two independently operating flame safeguards, aimed at reducing the possibility of loss of flame during operation in case of a simultaneous failure of both flame safeguards to an "improbable coincidence". With dual-supervision, the control contacts of the flame relays of both flame safeguards are connected in series so that loss of the flame signal of either of the flame safeguards is sufficient to cause lockout of the burner. A faulty signal by only one of the two flame safeguards during burner off times or purge times also leads to lockout. An ignited UV tube is a source of UV radiation! In case of flame supervision by means of UV detectors, both detectors must be placed such that there is no direct visual contact between them. Supervision of two manually controlled burners Mode of operation of the flame safeguards when used for the supervision of two manually operated burners With this type of supervision, too, the burner can be started only if the UV detector or flame simulation test has been successful. This means that neither of the two flame safeguards may detect a flame signal during burner off times. 0 77a02/ When the burner is started up, the detector test will automatically be I interrupted. 5 7 Brenner A When pressing button «I», relay «d» is energized via circuit path 4-5 of the flame relays, which is still closed, thus switching on the ignition of both burners. 6 4 3 5 7 2 L Brenner B At the same time, fuel is released. The duration of the start pulse given by pressing button «I» should be limited by a time relay - in the sense of a safety time. If the flame is established on both burners - indicated by the signal 6 4 3 d 2 L lamps of both flame safeguards - relay «d» is now maintained in its energized condition via circuit path 3-7 of the two flame relays. When releasing button «I», ignition will be switched off, thus completing the startup sequence. Z A ZB L2 BV A BV B If the event of loss of flame on one of the burners, the respective flame relay is de-energized, thereby neutralizing the holding circuit for relay «d». This means that the fuel valves of both burners will immediately be shut. The burners are switched off manually be pressing button «0», or - automatically - by the control / limit thermostat or pressurestat / pressure monitor in the phase wire connection. In the case of flame supervision with flame rectification probes, terminal 6 of the flame safeguards must be connected directly to the phase wire since no detector test is required here. For example: connection to terminal! Landis & Staefa Division CCN77E June 0, 5/

Detailed connection diagram (e.g. for gas burners) Mode of operation of flame safeguards with supervision multi-flame 2 6 5 7 LEC 3 4 5 Like with dual-supervision, the control contacts of the flame relays of all flame safeguards must be connected in series. A burner causes all other burners to go to lockout if the flame is not established during the safety time, or the flame is lost during operation 0 I Z GV GV2 BS 0 I Z GV GV2 BS 2 L 0 2 L 0 Correctly operating burners can be restarted only - after the burner control has been reset - when the faulty burner has been shut down. In that case, the operating switch must not only bridge the control contacts of the respective flame safeguard, thus closing the control chain again, but must also break the phase wire connection to the ignition transformer and the fuel valves. Likewise, after rectification of the fault, the burner can only be restarted in connection with the other burners, that is, only after all burners have previously been shut down. 0 I Z GV GV2 BS 2 L 0 7 7 a 0 3 / Terminal must be connected to earth also when using the UV detector Legend BS Operating switch OFF / ON Per burner Built-in signal lamp Indication of flame Detector electrode for flame rectification UV detector Flame relay Z Ignition transformer GV/...2 Gas valves st and 2 nd stage 6/ CCN77E June 0, Landis & Staefa Division

Basic circuit diagrams H 5 LEC LAE With selenium photocell detector RAR... 7 5 6 HR3 hr3 RAR... 3 4 LEC 2 77a04/ H 5 LEC L With UV detector 7 5 6 HR3 hr3 Terminal must be connected to earth! 3 4 LEC 2 77a05/0 7 5 H 6 L With flame rectification probe HR3 hr3 3 4 LEC 2 77a06/0 Legend Detector electrode for flame rectification Built-in signal lamp Flame relay Indication of flame H Main isolator UV detector HR3 Auxiliary relay for UV detector or flame simulation test RAR... Selenium photocell detector Landis & Staefa Division CCN77E June 0, 7/

Dimensions Base versions Dimensions in mm Low plug-in base, AGK 4 4 345 0 Design features: Ten-pole (screw terminals), with additional earth terminals. Cable entry either through the bottom of the base (two knock-out holes), the front, from the right or left side (total of five cable entries). 3 2 5 6 7 2 5 6 7 4,6 3 4 3 6 3 0 4 22 25 30 42,5 22 25 30 42,5 6,2 77m02/ High plug-in base, AGK 4 4 025 0 with removable front (shaded area in the drawing) Design features: Ten-pole (screw terminals): and - two auxiliary terminals with markings and 2 - two neutral terminals, wired to terminal 2 (neutral input) - two earth terminals, with earthing lug for the burner For cable entry: two cable entries in the bottom of the base and four threaded knockout holes for cable glands Pg, one on the right, one on the left, and in the removable front. 2 5 6 7 N 2 4,5 4 3 2 3,5 34 3,5 3 High plug-in base, AGK 4 4 6 0 Features as above, but without the removable front (shaded area in the drawing is open).,5 22 22 25 2 5 3 0 3 0 45 4 5 4,5 77m0/ 0 4 Front, AGK 4 4 2 0 As a separate item, suited for use with plug-in base AGK 4 4 6 0 (can also be used with AGK 4 4 025 0, shaded area in the drawing). Landis & Staefa Produktion GmbH / CCN77E June 0, Landis & Staefa Division