PAC BT LOW TEMPERATURE HEAT PUMP Just feel well COP up to. EER up to. PAC BT -7 kw A ++ + PRODUCTS Cooling and heating mode. Monobloc system. Available in 3PH (sizes 1 to 1). High flexibily due to DC Inverter compressor. FEATURES DC INVERTER C R1A FLUID MODE OPERATIONAL DOWN TO - C OUTDOORS DOMESTIC HOT WATER HIGH-TEMPERATURE RADIATOR ULTRA QUIET WATER PROGRAMMES PAC BT 9-1-1-1-1 kw q Digital display on indoor unit: mode selection (heating, cooling and Domestic Hot Water), weekly timer and holidays, diagnosis aid (display parameters, troubleshooting). q Provides optimal comfort all year long: Only one system for heating and cooling. q Ideal solution for radiant panel in heating and cooling mode, low temperature heater, or fan-coil units. q Plug & Play solution to replace old monobloc heat pumps. q. to 1.3 kw in heating mode /. to 1.1 kw in cooling mode over models q Operating in heating mode up to - C outdoor temperature (water outlet temperature up to C). q Operating in cooling mode up to C. q Compact solution: small footprint q Safety features included (safety valve, expansion tank). q High performances: COP up to. and EER up to.. q Energy efficiency coefficient up to 17,3% (ηs). q Auxiliary heat resistance included (depends on model - not included on sizes, 7 and 9). FLOOR FLOOR 17
PAC BT LOW TEMPERATURE HEAT PUMP OPERATING LIMITS: User function via remote control * 3 3 - - Auxiliary heat 1 Leaving water temperature ( C) * Shaded areas indicate no heat pump operation (backup electric heater or auxiliary heat source only). 1 1 Leaving water temperature ( C) DOMESTIC HOT WATER * 3 3 - - Auxiliary heat 1 Leaving water temperature ( C) * Shaded areas indicate no heat pump operation (backup electric heater or auxiliary heat source only).
Just feel well PAC BT KW PERFORMANCES 7 3 1-3, -, -1,, 1,, 3,, 3 C C C Outlet temp 7 3 1-1,, 1,, 3,,, PAC BT KW PERFORMANCES 1 1-3, -, -1,, 1,, 3,, 3 C C C Outlet temp 1 9 7 3 1-1,, 1,, 3,,, PAC BT 1 KW PERFORMANCES 1 1-3, -, -1,, 1,, 3,, 3 C C C Outlet tem 1 1-1,, 1,, 3,,, 3
PAC BT LOW TEMPERATURE HEAT PUMP PAC BT 1 KW PERFORMANCES 1 1 1-3, -, -1,, 1,, 3,, 3 C C C Outlet temp 1 1 1 1-1,, 1,, 3,,, PAC BT 1 KW PERFORMANCES 1 1 1 1-3, -, -1,, 1,, 3,, 3 C C C Outlet temp. 1 1 1 1 1-1,, 1,, 3,,, PAC BT 1 KW PERFORMANCES 1 1 1 1 1-3, -, -1,, 1,, 3,, 3 C C C Outlet temp. 1 1-1,, 1,, 3,,,
Just feel well PRINCIPALES OPTIONS ET ACCESSOIRES Photo / Part number Accessory Function ACCESSOIRES FOURNIS (included) (included) Y-shape filter User interface kit (digital remote controller) Protect the heat pump from sludging and preserve optimum thermal exchange. ON/OFF unit, outside heat source. Operation Mode setting: cooling/heating/auto DHW setting: Fast DHW / holiday/disinfect/ DHW pump setting Temp. setting: water outlet temp, room temp. Time setting: 1H/H Timer ON/OFF setting, Day/Weekly Display space heating/cooling set temp., water tank temp. Display components status Query, malfunction Code, Parameter, Test mode setting (included) T: Thermistor for domestic hot water tank DHW temperature control. ACCESSOIRES OPTIONNELS 7ACFH 3 L domestic hot water tank kit Optimised with the operation of the PAC - Programmable anti-legionellosis function - Management of the three-way valve / circulator pump couple - 3.1 m² exchange surface On-line electric heater - 3 kw It provides extra heating when the heating demand is greater than the capacity of the heat pump. It is matching only with sizes, 7 and 9. 7ACFH Settling filter (pot) Protect the heat pump from sludging and preserve optimum thermal exchange. 7ACFH Floor support rubber recycled (pair) Long: 1 mm Necessary for a professional installation. 7ACTL1 Mandatory accessory.
PAC BT LOW TEMPERATURE HEAT PUMP PAC BT MONOBLOC TECHNICAL DATA - SINGLE PHASE Models KW-H11 7KW-H11 9KW-H11 1KW-H11 1KW-H11 1KW-H11 1KW-H11 Code 1~3V-Hz 7HP11 7HP11 7HP117 7HP11 7HP119 7HP1 7HP11 MODE - OUTDOOR AIR REGIME +7 C / % HUMID BULB 3/3 C* / C 7/ C Heating capacity kw... 1.3 1.17 1.7 1.33 Power input kw.97 1..1..73 3. 3.9 COP.7..3.7..3.19 Heating capacity kw.7.9 9.19 1.17 1. 1. 1.1 Power input kw 1.3..3 3. 3..7. COP 3.7 3. 3.9 3.3 3. 3.1 3.9 Heating capacity kw.7. 9.3.9 1. 11. 13.3 Power input kw 1..39 3. 3.3 3..3. COP.3.1..3.7..7 MODE - OUTDOOR AIR REGIME 3 C indoor 3 C outdoor 1 C indoor 1 C outdoor 7 C OTHERS FEATURES Energy label SCOP SEER Operating range Water outlet temperatures Heating capacity kw...3 1. 1.19 1.1 1. Power input kw 1. 1.7.1.. 3.3 3. EER.. 3.97.9... Heating capacity kw..71. 1. 1.1 1.9 13.7 Power input kw 1..7 3.1 3..17.3.1 EER.9.1.3 3.1.93.. Water outlet à 3 C Water outlet à C ηs 17.9% 17.3% 13.3% 11.7% 1.% 17.7% 17.% class A++ A++ A++ A++ A++ A++ A++ ηs 1.7% 1.7% 17.1% 19.3% 19.3% 1.% 1.1% class A++ A++ A++ A++ A++ A++ A++ Water outlet à 3 C.7.3.1.1.1.39. Water outlet à C 3. 3. 3. 3.31 3.31 3.9 3. Water outlet à 7 C.1.7...3..3 Water outlet à 1 C.9.7.9...1. Cooling C -/ Heating C -/3 ECS C -/3 Cooling C / Heating C / ECS C / Fuse rating A Compressor type Outdoor fan Twin rotary DC inverter Number 1 1 1 Air flow m³/h 3 3 3 1 1 1 1 Circulator Head m 7. 7. 7. 7. Refrigerant Auxiliary heat resistance Sound level Type Precharge kg... 3. 3. 3. 3. Build in standard kw - - - 3 3 3 3 Optional kw 3 3 3.... Power stage number 1 1 1 R1A Power supply V/Ph/Hz -/1/ Heating db(a) 1 7 71 71 Cooling db(a) 7 7 7 7 Outline dimensions (WxHxD) mm 11 9 1 11 Package dimensions (WxHxD) mm 1 11 17 1 Net weight/gross weight kg 99/117 1/13 Liquid pipe diameter inches 1 Female BSP 1-1/ Female BSP Total water volume liters....
Just feel well PAC BT MONOBLOC TECHNICAL DATA - THREE PHASES Models 1KW-H13 1KW-H13 1KW-H13 Code 3~V-Hz 7HP1 7HP13 7HP1 MODE - OUTDOOR AIR REGIME +7 C / % HUMID BULB 3/3 C* / C 7/ C Heating capacity kw 1.37 1.1 1.3 Power input kw.7 3. 3. COP..33. Heating capacity kw 1. 1.11 1. Power input kw 3.7..3 COP 3.3 3.1 3.7 Heating capacity kw 1.1 1.1 1.1 Power input kw.3.1. COP..79.7 MODE - OUTDOOR AIR REGIME 3 C indoor 3 C outdoor 1 C indoor 1 C outdoor 7 C OTHERS FEATURES Energy label SCOP SEER Operating range Water outlet temperatures Heating capacity kw 1. 1.3 1.1 Power input kw.7 3. 3.7 EER..3. Heating capacity kw 1. 13. 1. Power input kw.3.1.1 EER.91..3 Water outlet à 3 C Water outlet à C ηs 17.9% 17.9% 13.% class A++ A++ A++ ηs 13.9% 17.9% 1.% class A++ A++ A++ Water outlet à 3 C..7.17 Water outlet à C 3.3 3.7 3. Water outlet à 7 C...9 Water outlet à 1 C.7.7.7 Cooling C -/ Heating C -/3 ECS C -/3 Cooling C / Heating C / ECS C / Fuse rating A Compressor type Outdoor fan Twin rotary DC inverter Number Air flow m³/h 1 1 1 Circulator Head m 7. 7. 7. Refrigerant Auxiliary heat resistance Sound level Type Precharge kg 3. 3. 3. Build in standard kw... Optional kw - - - Power stage number 1 1 1 R1A Power supply V/Ph/Hz 3-1/3/ Heating db(a) 71 71 Cooling db(a) 9 7 71 Outline dimensions (WxHxD) mm 1 11 Package dimensions (WxHxD) mm 17 1 Net weight/gross weight kg 177/19 Liquid pipe diameter inches 1-1/ Female BSP Total water volume liters... 7
FP-PAC BT EN 17 - AIRWELL RESIDENTIAL SAS - Specifications subject to change without notice. Pictures non contractual. Printed in UE. 3, AVENUE DU CENTRE - LES QUADRANTS - BAT. A - 7 GUYANCOURT, FRANCE TEL: +33 ()1 7 1 - FAX: +33 ()1 7 1 1 - www.airwell-residential.com