SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

Similar documents
SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submitted to: For Reference Approval Construction

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Ductless Split Systems Concealed Duct Heat Pumps

M-SERIES PRODUCT CATALOG

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Samsung 360 Cassette, Single Zone, Split System

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

PUHZ-SHW140YHA PUHZ-SHW230YKA

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Ductless Split Systems Ceiling Cassette Heat Pumps

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Residential and Light Commercial Ductless Systems Catalog

Digital Inverter 4 series 8 & 10HP

DESIGN & TECHNICAL MANUAL

A single answer for multiple zones.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Redefining Comfort. Mr. Slim Splitductless

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

FBQ. DC Duct Heat Pump or Cooling Only

A single answer for multiple zones.

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

DESIGN & TECHNICAL MANUAL

Product Data INDUSTRY LEADING FEATURES / BENEFITS

The Hyper-Heat Advantage

LV Series. SEER 15+ Concealed Built in Heat Pump

Ductless Split Systems Wall-mounted, Multizone Heat Pump

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Product Data INDUSTRY LEADING FEATURES / BENEFITS

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

ZONED COMFORT SOLUTIONS

DESIGN & TECHNICAL MANUAL

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Engineering Data Book

TECHNICAL DATA & SERVICE MANUAL

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

DESIGN & TECHNICAL MANUAL

Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Engineering Data Book

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Lennox Mini-Split Systems Year-Round Comfort and Performance

Air Conditioners. Technical Data RZQG-L

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL

Product Catalogue. Mitsubishi Electric Sales Canada Inc. Pseries.MrSlim.ca

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Air Conditioning & Heating. Ductless Product Catalog

Transcription:

P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS INDOOR UNIT FEATURES Airflow settings for high and low ceiling applications Knock-out for outside-air intake Optional i-see Sensor TM for air distribution and energy saving Auto fan speed mode Filter status indicator Easy-to-clean, washable filter Suspends from ceiling for quick and easy installation Ideal for larger retail stores, classrooms, and restaurants OUTDOOR UNIT FEATURES Variable speed INVERTER-driven compressor Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) 24-hour continuous operation (cooling mode) High pressure protection Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers Superior energy and operational efficiency

SPECIFICATIONS: PCA-A24KA7 & PUZ-A24NHA7(-BS) Model number Indoor unit PCA-A24KA7 Outdoor unit PUZ-A24NHA7 PUZ-A24NHA7-BS Cooling*1 Maximum Capacity Btu/h 24,000 Rated Capacity Btu/h 24,000 Minimum Capacity Btu/h 10,000 Maximum Power Input W 1,960 Rated Power Input W 1,960 Moisture Removal Pints/h 5.80 Sensible Heat Factor 0.73 Power factor % 94.70 Heating at 47 F*2 Maximum Capacity Btu/h 28,000 Heating at 17 F *3 Rated Capacity Btu/h 26,000 Minimum Capacity Btu/h 8,800 Maximum Power Input W 2,230 Rated Power Input W 1,800 Power factor % 94.30 Maximum Capacity Btu/h 17,900 Rated Capacity Btu/h 15,400 Maximum Power Input W 1,770 Rated Power Input W 1,700 Efficiency SEER 21.20 EER *1 12.20 HSPF (IV) 10.80 COP at 47 F *2 4.23 COP at 17 F *3 2.65 Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size A 25 Recommended Wire Size (Indoor - Outdoor) AWG 14 Indoor unit MCA A 1.00 Fan Motor Full Load Amperage A 0.54 Fan Motor Output W 95

SPECIFICATIONS: PCA-A24KA7 & PUZ-A24NHA7(-BS) Model number Indoor unit PCA-A24KA7 Indoor unit operating temperature range Outdoor unit PUZ-A24NHA7 PUZ-A24NHA7-BS Airflow Rate, Dry CFM 530-565-600-670 Airflow Rate, Wet CFM 495-530-565-635 External Static Pressure in.wg n/a Sound Pressure Level db(a) 33-35-37-40 Drain Pipe Size In. (mm) 1-1/32 (26) Heat Exchanger Type Plate fin coil External Finish Color White Munsell 6.4Y 8.9/0.4 Unit Dimensions W: In. (mm) 50-3/8 (1280) D: In. (mm) 26-3/4 (680) H: In. (mm) 9-1/16 (230) Package Dimensions W: In. 53-2/16 D: In. 29-15/16 H: In. 12-10/16 Unit Weight Lbs. (kg) 71 (32) Package Weight Lbs. 82 Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 90 DB, 73 WB / 66 DB, 59 WB F 82 DB / 50 DB Outdoor unit MCA A 19 MOCP A 26 Fan Motor Full Load Amperage A 0.4 Fan Motor Output W 86 Airflow Rate CFM 1,940 Refrigerant Control Defrost Method Heat Exchanger Type Electronic Expansion Valve Reverse Cycle Cross fin Sound Pressure Level, Cooling*1 db(a) 47 Sound Pressure Level, Heating*2 db(a) 48 Compressor Type Compressor Model INVERTER-driven twin rotary SNB172FWHM1 Compressor Rated Load Amps A 7 Compressor Locked Rotor Amps A 11 Compressor Oil Type // Charge oz. FV50S // 23

SPECIFICATIONS: PCA-A24KA7 & PUZ-A24NHA7(-BS) Model number Indoor unit PCA-A24KA7 Outdoor unit operating temperature range Outdoor unit PUZ-A24NHA7 PUZ-A24NHA7-BS External Finish Color Ivory Munsell 3Y 7.8/1.1 Base pan heater Unit Dimensions W: In. (mm) 37-13/32 (950) n/a D: In. (mm) 13 + 1-3/16 (330 + 30) H: In. (mm) 37-1/8 (943) Package Dimensions W: In. 40-15/16 D: In. 17-11/16 H: In. 40-11/16 Unit Weight Lbs. 153 (69) Package Weight Lbs. 112 (51) Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 115 DB / 0* DB F 70 DB, 59 WB / -4 DB, -4 WB Thermal Lock-out / Re-start Temperatures** F -8 / -4 DB Refrigerant Type R410A Charge Lbs, oz 7 lbs, 11 oz Piping Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Maximum Piping Length Ft. (m) 165 (50) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor) F 80 F DB, 67 F WB // 95 F DB, 75 F WB *2 Heating at 47 F (Indoor // Outdoor) F 70 F DB, 60 F WB // 47 F DB, 43 F WB *3 Heating at 17 F (Indoor // Outdoor) F 70 F DB, 60 F WB // 17 F DB, 15 F WB Conditions *4 Heating at 5 F (Indoor // Outdoor) F 70 F DB, 60 F WB // -4 F DB, -5 F WB Notes *Wind baffles required to operate below 23 F DB in cooling mode. PUZ with wind baffle: 0 F - 115 F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures

SPECIFICATIONS: PCA-A24KA7 & PUZ-A24NHA7(-BS) SEACOAST PROTECTION External Outer Panel: Phosphate coating + Acrylic-Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes:

ACCESSORIES: PCA-A24KA7 & PUZ-A24NHA7(-BS) PCA-A24KA7 High Efficiency (MERV 8) Filter Element PAC-SH89KF-E High Efficiency (MERV 8) Filter Element PAC-SE81KF-E 3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] TAZ-MS303 Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) DPLS2 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (110V) X87-711 - 110 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (208/230V) X87-721 - 208/230 MegaBlue Blue Diamond Condensate Pump (110-230V) X87-835 i-see Sensor TM PAC-SH91MK-E External fan / Heater control relay adapter CN24RELAY-KIT-CM3 Backlit, wall-mounted, wireless MHK1 Wireless Remote Controller MRCH1 Wireless Receiver MFH1 Portable Central Controller MCCH1 Outside Air Sensor MOS1 Wireless adapter PAC-USWHS002-WF-1 BACnet and Modbus Interface PAC-UKPRC001-CN-1 Wall-mounted, Wired PAC-YT53CRAU-J Wired remote controller PAR-32MAA-J Remote Controller Kit PAR-SL93B-E Remote Controller Kit with i-see Sensor TM PAR-SA92MW-E T-STAT Interface PAC-US444CN-1 Wired remote controller PAR-32MAA Simple remote controller PAC-YT53CRAU Wireless Remote Controller PAR-FL32MA-E Wire for Remote ON/OFF with CN32 connector PAC-715AD Lockdown Bracket for wireless, hand-held, remote controllers RCMKP1CB PUZ-A24NHA7(-BS) Twinning Distribution Pipe (50:50) Front Wind Baffle Drain socket Centralized Drain Pan M-NET Converter Control/Service Tool Wall mounting bracket (powder-coated steel) MSDD-50TR-E WB-PA5 PAC-SG61DS-E PAC-SG64DP-E PAC-SF83MA-E PAC-SK52ST QCWB2000M-1

ACCESSORIES: PCA-A24KA7 & PUZ-A24NHA7(-BS) PUZ-A24NHA7(-BS) Wall mounting bracket (316 Series Stainless Steel) QCWBSS M-NET control adapter for Building Management System PAC-SF83MA-E Outdoor Unit Mounting Pad 24" x 42" x 3" ULTRILITE2 Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) DSD-400N MiniSplit Mounting Stand-Single Fan models - 12" QSMS1201M MiniSplit Mounting Stand-Single Fan models - 18" QSMS1801M MiniSplit Mounting Stand-Single Fan models - 24" QSMS2401M 3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-100

DIMENSIONS: PCA-A24KA7 & PUZ-A24NHA7 (-BS) PCA-A24KA7 [FRONT VIEW] Electrical box 5 10-1/4(260) 1 4 Unit: inch (mm) 7-1/2(190) 3 3(76) Ceiling 120 3-3/8(85) 3-3/8(86) 1/16(2) 1/16(1) 4-15/16(126) 48-11/16(1237) (Suspension bolt pitch) 5-7/8(150) 11/16(18) 5-1/2(140) 2-7/16(62) 6 1-13/16(46) 2-15/16(75) 2 When electrical box is pulled down Electrical box 4-7/8(124) 5/16(8) 4-3/4(121) 18-1/8(461) 1-7/8(48) Φ4-15/16(Φ125) 8 7 11/16(18) 1-1/2(38) 15-1/4(387) 5-7/16(138) In case of the rear pipe arrangement, make sure to remove the shaded portions from the independent piece. Then put the independent piece back in initial position.(the heat exchanger might be clogged because of dust) 1-7/16(37) 7-1/12(190) 1/16(2) 50-3/8(1280) 1/16(2) 46-3/16(1173) 12-5/8(320) 9-1/16(230) 3-1/8(80) 26-3/4(680) 2(51) 3/8(10) 3/16(5) 9-5/16(236) 2 9-3/16(233) 9-11/16(246) When drain socket is installed Drainage Air outlet 7-3/16(182) 3-5/16(84) 3-7/16(88) 7-11/16(195) 3-3/8(85) In case of wireless remote controller and i-see sensor (Optional Parts) 9/16 14 7-1/16(180) 7-7/8(200) 9-3/16(233) 9-11/16(246) liquid Φ3/8(Φ9.52) gas Φ5/8(Φ15.88) When drain socket is installed Drainage 1 2 3 4 5 6 7 8 Drainage pipe connection(1(26mm)i.d.) Drainage pipe connection(for the left arrangement) Knockout hole for left drain-piping arrangement Refrigerant-pipe connection(gas pipe side/flared connection) Refrigerant-pipe connection(liquid pipe side/flared connection) Knockout hole for upper drain pipe arrangement Knockout hole for fresh air intake Φ3-15/16(Φ100) Knockout hole for wiring arrangement Φ7/8(Φ22) Accessory...Drain socket (1(26mm) I.D.) Air intake 47-3/16(1198) 10(254) 18-3/4(476) 2-1/4(57) 26-3/4(680) Emergency operation switch <Cooling> i-see sensor In case of wireless remote controller and i-see Sensor(Optional Parts) Emergency operation switch <Heating> Receiver DEFROST/STAND BY lamp Operation lamp NOTES. 1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain pump (option parts), refrigerant pipe will be only upward.

DIMENSIONS: PCA-A24KA7 & PUZ-A24NHA7 (-BS) 2-U Shaped notched holes (Foundfation Bolt M10<W3/8>) 175 <6-7/8> 19<3/4> 330 <13> Air Discharge 61<2-13/32> 40<19/32> 0 53<2-3/32> 70 <2-3/4> 57<2-1/4> 41 <1-5/8> 2-12 36 oval holes (Foundation Bolt M10<W3/8>) Min. Min.100mm <3-15/16> FOUNDATION 25 <31/32> 500 <19-11/16> Side Air Intake Max. 500 <19-11/16> Min. 175<6-7/8> Rear Air Intake Side Air Intake Handle for moving Terminal Connections Left... Power supply wiring Reight... Indoor/Outdoor wiring 950 <37-13/32> 322<12-11/16> Earth terminal Service panel 19<3/4> 5/8> 92 <3-5/8> 55 <2-3/16> Power supply wiring hole (2- ø27<1-1/16>knockout) Rear trunking hole -5/8> ø92 <3 Rear piping hole 1/2 Conduit attachment 2-ø22.2<7/8> 40<1-9/16> 74<2-19/32> 219 <8-5/8> 40<1-9/16> 71<2-13/16> Set the attachment to the When installing the conduit, inner side of each panel. 81<3-3/16> ø 92 <3-45<1-25/32> 73 <2-7/18> 63 <2-1/2> 55 <2-3/16> 40<1-9/16> 27<1-1/16> 63<2-1/2> 55<2-3/16> 75 <2-31/32> 23 <29/32> 65<2-9/16> 27 23 <29/32> <1-1/16> 92 <3-5/8> 73 <2-7/18> 63 <2-1/2> 92<3-5/8> Right piping hole 30 <1-3/16> 669<26-11/32> *1 447<17-5/8> 2 Front piping cover Rear piping cover Bottom piping hole 220 <8-21/32> 145 145 145 <5-23/32> <5-23/32> <5-23/32> Drain hole (5- ø33<1-5/16>) 92<3-5/18> 65 <2-9/16> PUY-A30NHA7 PUY-A30NHA7-BS Front piping hole ø 92 <3-5/8> 45<1-25/32> 27<1-1/16> 73 <2-7/8> Power supply wiring hole (2-ø27knockout) Front trunking hole 40<1-9/16> Power supply wiring hole (2- ø27knockout) Right trunking hole 31<1-7/32> Piping knockout Hole Details 1 71 <2-13/16> Air Intake PUY-A24NHA7 PUY-A24NHA7-BS 1... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8f) 2... Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F) *1... Indication of STOP VALVE connection location. *1 431<16-31/32> Handle for moving 943 <37-1/8> 473 <18-5/8> 23 <29/32> Handle for moving Example of Notes 23 <29/32> 15 Handle for moving PUZ-A30NHA7 PUZ-A30NHA7-BS Service space 30 <1-3/16> Min. 100 <3-15/16> Min. 10 <13> Min. 10mm <3/8> 600<23-5/8> Installation Feet <Foundation bolt height> Min. 10mm <3/8> Min. 500mm <19-11/16> Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. 370<14-9/16> 417 <1-1/32> Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.) Rear Air Intake 28<1-3/32> Dimensions of space needed for service access are shown in the below diagram. The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. Unit: mm<in> 4 PIPING-WIRING DIRECTIONS 3 FOUNDATION BOLTS FREE OCH636 2 SERVICE SPACE 1 FREE SPACE (Around the unit) PUZ-A24NHA7 PUZ-A24NHA7-BS PUZ-A24NHA7(-BS) 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# PCA-A24KA7 / PUZ-A24NHA7(-BS) - 201702