Technical Information

Similar documents
TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

GKS9 40" 90% Gas Furnaces

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL INFORMATION MANUAL

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

TECHNICAL INFORMATION MANUAL

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal

Operator: Save these instructions for future use!

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

50A Integrated Furnace Control

50A Integrated Furnace Control

Operator: Save these instructions for future use!

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

MERIT SERIES Downflow

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

TECHNICAL SPECIFICATIONS

40 Residential Gas Furnace Operation

Operator: Save these instructions for future use!

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Operator: Save these instructions for future use!

Cooling Capacity CFM in. w.c. (125 Pa)

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GMS9/GCS9 SERIES 93% AFUE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Cooling Capacity CFM range

Cooling Capacity CFM in. w.c. (125 Pa)

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Wt. Lbs Model Number (BTUH) Hz

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

G6RC Series TECHNICAL SPECIFICATIONS

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

MULTI POSITION GAS FURNACE

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Ruud Achiever Series Multi position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Multi-Position Gas Furnaces

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Installation and Operating Instructions

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

ELITE SERIES Downflow - High Efficiency Blower Motor

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

ComfortNet -Compatible

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

TSTAT0101SC Recommended (order separately)

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

FG7T (C and L Series)

MULTI POSITION GAS FURNACE

RG7D 1-Stage Heat Series

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

TSTAT0201CW Recommended (sold separately)

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

AVPTC. Air Handlers 1½ to 5 Tons

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Transcription:

A I R COMMA ND GAS FURNACE Technical Information 40" 80% Gas Furnaces GUIC EA/EX Refer to Service Manual RS660000 Rev. 2 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual. Refer to the appropriate Parts Catalog for part number information. Model and Manufacturing numbers listed in this manual. MODEL GUIC045EA30 GUIC070EA30 GUIC070EA40 GUIC090EA30 GUIC090EA50 GUIC5EA40 GUIC5EA50 GUIC40EA50 GUIC045EX30 GUIC070EX30 GUIC070EX40 GUIC090EX30 GUIC090EX50 GUIC5EX40 GUIC5EX50 GUIC40EX50 M/N P23400F P234002F P234003F P234004F P234005F P234006F P234007F P234008F P2340F P23402F P23403F P23404F P23405F P23406F P23407F P23408F 80 SSE DESIGN This manual replaces RT662006 Rev. 0 November 200. C E R TIFIE D C E R T I F I E D REV. - Corrections made to manual. Heating&Air Conditioning Comfort. Quality. Trust. This manual is to be used by qualified HVAC technicians only. Amana does not assume any responsibility for property damage or personal injury due to improper service procedures performedby an unqualified person. RT662006 Revision February 2002

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. When engineering and manufacturing changes take place where interchangeability of components are affected, the manufacturing number will change. It is very important to use the model and manufacturing numbers at all times when requesting service or parts information. G U I C 045 E A 30 Product Type G: Gas Furnace Supply Type U: Upflow/Horizontal Furnace Type I: Induced Draft (80%) Airflow Capability 30: 3.0 Tons 40: 4.0 Tons 50: 5.0 Tons Additional Features A: Not NOx Certified X: NOx Models Design Series E: Fifth Design Series Model Family C : Air Command 80 SSE (Category Venting) Nominal Input 045: 45,000 Btuh 070: 70,000 Btuh 090: 90,000 Btuh 5: 5,000 Btuh 40: 40,000 Btuh WARNING IF REPAIRS ARE ATTEMPTED BY UNQUALIFIED PERSONS, DANGER- OUS CONDITIONS (SUCH AS EXPOSURE TO ELECTRICAL SHOCK) MAY RESULT. THIS MAY CAUSE SERIOUS INJURY OR DEATH. CAUTION AMANA WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCE- DURES. IF YOU PERFORM SERVICE ON YOUR OWN PRODUCT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. 2 Rev.

PRODUCT DIMENSIONS 28-3/4 28 3/4 20 4 5/8 Supply Upflow Left Side View Knock-Out For Venting Electrical Hole "High Voltage" GUIC EA/EX 3/4 Upflow Front View A B C 3/4 E Upflow Right Side View 4 /6 Supply /2 4 Gas Supply Hole 23 Electrical Hole "Low Voltage" Side Cut-Out 4-5/8 28-/4 3-5/8 37-3/8 40 34-5/8 3-3/4-3/4 2-/2 Side Cut-Out 5/8 23 /2 Bottom Knock-Out D Bottom Knock-Out FURNACE MODEL GUIC045E*30 GUIC5E*40 GUIC5E*50 GUIC40E*50 GUIC DIMENSIONS A B C D E Minimum Vent Diameter 6-/2 5 5-/4 2-5/8 4 4 20-/2 9 7-/4 4-5/8 4 4 24-/2 23 9-/4 8-5/8 4 5 All dimensions are in inches. Note: Access door inlet louvered vent configuration is dependent upon unit size. See drawings below. GUIC045E*30 GUIC5E*40 GUIC5E*50 GUIC40E*50 GUIC EA (Manufacturing Numbers P23400-08F) GUIC EX (Manufacturing Numbers P2340-08F) 3 Rev.

COMPONENT IDENTIFICATION 8 9 20 2 BLOWER COMPARTMENT BURNER COMPARTMENT 7 6 5 4 3 2 BLOWER HARNESS 22 23 2 3 4 5 6 7 8 Single Stage Gas Valve 2 Hot Surface Igniter 3 Burners 4 Gas Manifold 5 Blower Door Interlock Switch 6 Capacitor 7 PSC Multi-speed Circulator Blower 8 Single-Stage Integrated Control Module (with diagnostic LED) 9 Control Mounting Bracket 0 Transformer (40 VA) 24 Volt Thermostat Connections 0 9 Upflow/Horizontal 2 Bottom Return Filter Retainer 3 Auxiliary Limit 4 Flame Sensor 5 Gas Line Entrance 6 Rollout Limit 7 Electrical Connection Inlets (Alternate) 8 Single-Speed Induced Draft Blower 9 Flue Pipe Connection 20 Pressure Switch 2 Junction Box 22 Electrical Connection Inlets 23 Primary Limit Control 4 Rev. GUIC EA (Manufacturing Numbers P23400-08F) GUIC EX (Manufacturing Numbers P2340-08F)

PRODUCT DESIGN General Operation This GUIC furnace is equipped with an electronic ignition device to light the burners and an induced draft blower to exhaust combustion products. An interlock switch prevents furnace operation if the blower door is not in place. Keep the blower access doors in place except for inspection and maintenance. This furnace is also equipped with a self-diagnosing electronic control module. In the event a furnace component is not operating properly, the control module LED will flash on and off in a factory-programmed sequence, depending on the problem encountered. This light can be viewed through the observation window in the blower access door. Refer to the Troubleshooting Chart for further explanation of the LED codes and Abnormal Operation - Integrated Ignition Control section in the Service Instructions for an explanation of the possible problem. The rated heating capacity of the furnace should be greater than or equal to the total heat loss of the area to be heated. The total heat loss should be calculated by an approved method or in accordance with ASHRAE Guide or Manual J-Load Calculations published by the Air Conditioning Contractors of America. *Obtain from: American National Standards Institute 430 Broadway New York, NY 008 Location Considerations The furnace should be as centralized as is practical with respect to the air distribution system. Do not install the furnace directly on carpeting, tile, or combustible material other than wood flooring. When suspending the furnace from rafters or joists, use 3/8" threaded rod and 2 x 2 x 3/8 angle as shown in the Installation and Service Instructions. The length of the rod will depend on the application and clearance necessary. When installed in a residential garage, the furnace must be positioned so the burners and ignition source are located not less than 8 inches (457 mm) above the floor and protected from physical damage by vehicles. Accessibility Clearances (Minimum) MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (INCHES) POSITION* FRONT RIGHT LEFT REAR TOP FLUE FLOOR Upflow 6 0 0 0 6 2 C Horizontal Left Alcove 6 2 0 6 2 C Horizontal Right Alcove 2 6 0 6 2 C * = All positioning is determined as installed unit viewed from the front. = inch when using Type B- vent is used. 2 = inch when Type B- vent is used. C = If placed on combustible floor, floor MUST be wood ONLY. 36" at front is required for servicing or cleaning. Note: In all cases accessibility clearance shall take precedence over clearances from the enclosure where accessibility clearances are greater. All dimensions are given in inches. High Altitude Derate When this furnace is installed at high altitude, the appropriate High Altitude orifice kit must be installed. This is required due to the natural reduction in the density of both the gas fuel and combustion air as altitude increases. The kit will provide the proper design certified input rate within the specified altitude range. MODEL NUMBER GUIC***EA/EX** PROPANE AND HIGH ALTITUDE KITS 0 to 7,500 ft. 7,50 to,000 ft. 7,50 to,000 ft. LPTK09 Propane Conversion Kit (#55 Orifice) HANG5 High Altitude Natural Gas Kit (#45 Orifice) HALP2 High Altitude Propane Gas Kit (#56 Orifices) 4,50 to,000 ft. HACPS5 High Altitude Pressure Switch Kit ( 0727920) High altitude kits are purchased according to the installation altitude and usage of either natural or propane gas. Refer to the chart above for a tabular listing of appropriate altitude ranges and corresponding manufacturer s high altitude Natural Gas and Propane Gas kits. For a tabular listing of appropriate altitude ranges and corresponding manufacturer's High Altitude Pressure Switch kits, refer to either the Pressure Switch Trip Points & Usage Chart in this manual or the Accessory Charts in Service Instructions. 5 Rev.

PRODUCT DESIGN PRESSURE SWITCH TRIP POINTS AND USAGE CHART MODEL MINIMUM NEGATIVE PRESSURE WITH FLUE NOT FIRING TYPICAL SEA LEVEL DATA MINIMUM NEGATIVE PRESSURE WITH FLUE FIRING TYPICAL SEA LEVEL DATA TRIP POINT PRESSURE SWITCH TRIP POINTS AND USAGE 0 to 4,500 ft. PRESSURE SWITCH (Prod.) LABEL COLOR TRIP POINT 4,50 to,000 ft. HIGH ALTITUDE KIT LABEL COLOR GUIC045E*30-0.90-0.80-0.75 072792 Green GUIC5E*40 GUIC5E*50-0.85-0.85-0.85-0.75-0.75-0.75-0.70-0.70-0.70 0727923 0727923 0727923 Orange Orange Orange HACPS5-0.55 Dark Blue 0727920 HACPS5 0727920 HACPS5 0727920 HACPS5 0727920 HACPS5 GUIC40E*50-0.85-0.75-0.70 0727923 Orange -0.55 Dark Blue 0727920 Note: Replacement pressure switch number is listed below High Altitude Pressure Switch Kit number. Note: All negative pressure readings are in inches of water column (" w.c.). -0.55-0.55-0.55 Dark Blue Dark Blue Dark Blue Part Number 0728324 0728330 0728339 Part Number 023527 023528 Part Number 02359 Open Setting F 35 200 90 Open Setting F 260 275 Open Setting F 60 Style 3 3 3 Dot Color Brown Pink Dot Color Pink Sleeve Color Green Tan Red GUIC045E*30 GUIC045E*30 GUIC045E*30 2 2 GUIC5E*40 GUIC5E*50 GUIC40E*50 T.O.D. PRIMARY LIMIT ROLLOUT LIMIT SWITCHES GUIC5E*40 GUIC5E*50 2 AUXILIARY LIMIT SWITCHES GUIC5E*40 GUIC5E*50 GUIC40E*50 2 GUIC40E*50 6 Rev.

PRODUCT DESIGN Coil Matches: A large array of Amana coils are available for use with the GUIC furnace, in either upflow, counterflow, or horizontal applications. These coils are available in both cased and uncased models, with or without a TXV expansion device. These 80% furnaces match up with the existing Amana coils as shown in the chart below. Btuh Input Cabinet Width Air Flow (tons) CAA_F*C Cased A-Coils CCA_FSC Uncased A-Coils CHA_TCC Cased TXV A-Coils CHA_TSC Uncased TXV A-Coils CCF_F*C Horiz. A-Coils CHF_TCC Horiz. A-Coils GUIC045E*30 6 /2" /2-3 6 /2" /2-3 2 /2-4 CCA8FCC CCA24FCC CCA30FCC CCA36FCC CCA42FCC CCA8FSC CCA24FSC CCA30FSC CCA36FSC CCA42FSC CHA8TCC CHA24TCC CHA30TCC CHA36TCC CHA8TSC CHA24TSC CHA30TSC CHA36TSC CCF24FCC CCF30FCC CCF36FCC CHF8TCC CHF24TCC CHF30TCC 20 /2" /2-3 3-5 CCA30FDC CCA36FDC CCA42FDC CCA48FCC CCA48FSC CHA42TCC CHA42TSC CCF24FDC CCF36FDC CCF42FCC CCF48FCC CHF36TCC CHF42TCC GUIC5E*40 GUIC5E*50 24 /2" 2 /2-4 3-5 GUIC40E*50 24 /2" 3-5 CCA36FKC CCA48FDC CCA54FCC CCA57FCC CCA60FCC CCA54FSC CCA57FSC CCA60FSC CHA48TCC CHA54TCC CHA57TCC CHA60TCC CHA48TSC CHA54TSC CHA57TSC CHA60TSC CCF48FDC CCF60FCC CHF48TCC Coil Matches (for the Amana RSD units using R-40A): Btuh Input Cabinet Width Air Flow (tons) CA_FCA Cased A-Coils CF_FCA Horizontal A-Coils GUIC045E*30 6 /2" /2-3 6 /2" /2-3 2 /2-4 CA36FCA CF30FCA 20-/2" /2-3 3-5 CA42FCA CF36FCA GUIC5E*40 GUIC5E*50 24-/2" 2 /2-4 3-5 GUIC40E*50 24-/2" 3-5 CA48FCA CA57FCA CF48FCA CF60FCA 7 Rev.

PRODUCT DESIGN Thermostats: The following Amana Thermostats are suggested for use with the GUIC Furnace Models: Thermostats Thermostat Man/Auto Programmable Cool Heat Batt. Powered Batt. Bkup* Shape Color 2340 Man. Changeover Yes Yes No Rectangular White 23402 Man. Changeover No Yes No Rectangular White 23408 Man. or Auto Changeover Yes No Yes Rectangular White Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will accommodate the following filter sizes depending on cabinet size: Side Return(s) Bottom Return Cabinet Width (in.) Nominal Filter Size (in.) Approx. Flow Area (in 2 ) Cabinet Width (in.) Nominal Filter Size (in.) Approx. Flow Area (in 2 ) All 6 x 25 x 400 6-/2 4 x 25 x 350 20-/2 6 x 25 x 400 24-/2 20 x 25 x 500 Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return. GUIC E* Model (Input Airflow) Cooling Airflow Requirement (CFM) 600 800 000 200 400 600 2000 045 30 335* 384 480 576 --- --- --- 070 30 503* 503* 503* 576 --- --- --- 070 40 --- --- 503* 576* 672 768 --- 090 30 60* 60* 60* 60* --- --- --- 090 50 --- --- --- 60* 672 768 960 5 40 --- --- 838* 838* 838* 838* --- 5 50 --- --- --- 838* 838* 838* 960 40 50 --- --- --- 006* 006* 006* 006* *Minimum filter area dictated by heating airflow requirement. Disposable Minimum Filter Area (in 2 ) [Based on a 300 ft/min filter face velocity] Cooling Airflow Requirement (CFM) 600 800 000 200 400 600 2000 045 30 68* 92 240 288 --- --- --- 070 30 25* 25* 25* 288 --- --- --- 070 40 --- --- 25* 288 336 384 --- GUIC E* 090 30 305* 305* 305* 305* --- --- --- Model (Input Airflow) 090 50 --- --- --- 305* 336 384 480 5 40 --- --- 49* 49* 49* 49* --- 5 50 --- --- --- 49* 49* 49* 480 40 50 --- --- --- 503* 503* 503* 503* *Minimum filter area dictated by heating airflow requirement. Permanent Minimum Filter Area (in 2 ) [Based on 600 ft/min filter face velocity] 8 Rev.

FURNACE SPECIFICATIONS MODEL GUIC045E*30 GUIC5E*40 GUIC5E*50 GUIC40E*50 Btuh Input (US) 46,000 69,000 69,000 92,000 92,000 5,000 5,000 40,000 Output (US) 36,800 55,200 55,200 73,600 73,600 92,000 92,000 0,400 A.F.U.E. 80% 80% 80% 80% 80% 80% 80% 80% Rated External Static (" w.c.).0 -.50.2 -.50.2 -.50.5 -.50.5 -.50.20 -.50.20 -.50.20 -.50 Temperature Rise ( F) 35-65 35-65 35-65 40-70 40-70 35-65 35-65 35-65 Pressure Switch Trip Point (" w.c.) -0.75-0.70-0.70-0.70-0.70-0.70-0.70-0.70 Blower Wheel (D" x W") 0 x 7 0 x 7 0 x 7 0 x 9 0 x 9 0 x 0 0 x 0 0 x 0 Blower Horsepower /3 /2 /2 /2 3/4 /2 3/4 3/4 Blower Speeds 4 4 4 4 4 4 4 4 Max CFM @ 0.5 E.S.P. 25 54 500 258 998 596 2007 28 Power Supply 5-60- 5-60- 5-60- 5-60- 5-60- 5-60- 5-60- 5-60- Minimum Circuit Ampacity (MCA) 6.4 6.4 3.4 6.4.2 0.4.9 4.3 Maximum Overcurrent Device 5 5 5 5 5 5 5 5 Transformer (VA) 40 40 40 40 40 40 40 40 Heat Anticipator 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 Primary Limit Setting ( F) 200 90 90 200 200 90 90 35 Auxiliary Limit Setting ( F) 60 60 60 60 60 60 60 60 Rollout Limit Setting ( F) 275 275 275 275 275 260 260 275 Fan Delay On 30 secs. 30 secs. 30 secs. 30 secs. 30 secs. 30 secs. 30 secs. 30 secs. Off Heating * 90 secs. 90 secs. 90 secs. 90 secs. 90 secs. 90 secs. 90 secs. 90 secs. Off Cooling 45 secs. 45 secs. 45 secs. 45 secs. 45 secs. 45 secs. 45 secs. 45 secs. Gas Supply Pressure (Natural/Propane) ("w.c.) 7 / 7 / 7 / 7 / 7 / 7 / 7 / 7 / Manifold Pressure (Natural/Propane) ("w.c.) 3.5 / 0 3.5 / 0 3.5 / 0 3.5 / 0 3.5 / 0 3.5 / 0 3.5 / 0 3.5 / 0 Orifice Size (Natural/Propane) #43 / #55 #43 / #55 #43 / #55 #43 / #55 #43 / #55 #43 / #55 #43 / #55 #43 / #55 Number of Burners 2 3 3 4 4 5 5 6 Vent Connector Diameter (inches) 4 4 4 4 4 4 4 4 Shipping Weight (lbs.) 40 5 52 69 78 90 94 98 * Off Heating - This fan delay timing is adjustable (60, 90, 20 or 80 seconds), 90 seconds as shipped.. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane gas operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude. 3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output. 4. Minimum Circuit Ampacity calculated as: (.25 x Circulator Blower Amps) + I.D. Blower Amps. 9 Rev.

BLOWER PERFORMANCE SPECIFICATIONS GUIC***EA/EX** Blower Performance (CFM & Temperature Rise vs. External Static Pressure) TONS AC External Static Pressure (Inches Water Column) Model MOTOR @ 0.5" 0. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Heating Speed SPEED ( As Shipped) ESP CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM HIGH 3.0 296 ---- 306 ---- 286 ---- 256 ---- 25 ---- 5 082 009 GUIC045E*30 MED 2.5 058 ---- 070 ---- 052 ---- 034 ---- 05 ---- 97 97 859 (LOW) MED-LO 2.0 835 4 842 40 838 4 827 4 805 42 774 733 77 LOW.5 635 54 620 55 66 55 6 56 590 58 564 530 462 HIGH 3.0 328 38 298 39 260 4 204 42 54 44 084 009 98 MED 2.5 46 45 20 46 084 47 047 49 990 52 928 863 766 (MED) MED-LO 2.0 938 54 99 56 889 57 854 60 8 63 76 694 66 LOW.5 788 65 76 ---- 732 ---- 699 ---- 650 ---- 60 543 466 HIGH 4.0 853 ---- 777 ---- 674 ---- 608 ---- 500 ---- 4 325 200 MED 3.5 595 ---- 55 ---- 500 ---- 439 36 376 37 295 26 23 (LOW) MED-LO 3.0 325 39 30 39 295 39 264 40 26 42 67 088 003 LOW 2.5 060 48 057 48 055 48 05 49 022 50 983 92 854 HIGH 3.0 43 48 420 48 43 48 392 49 258 54 250 07 974 MED 2.5 43 60 5 59 5 59 25 6 07 62 033 943 795 (HIGH) MED-LO 2.0 9 ---- 922 ---- 9 ---- 900 ---- 864 ---- 783 703 580 LOW.5 703 ---- 689 ---- 644 ---- 629 ---- 596 ---- 526 447 397 HIGH 5.0 2244 ---- 280 ---- 23 ---- 2033 ---- 998 ---- 875 76 587 MED 4.0 77 38 744 39 76 40 688 40 67 42 572 462 379 (MED-LO) MED-LO 3.5 47 46 46 47 440 47 49 48 386 49 38 247 58 LOW 3.0 235 55 222 56 20 56 84 58 45 60 04 048 924 HIGH 4.0 824 47 765 48 722 49 669 5 596 53 499 385 283 GUIC5E*40 MED 3.5 605 53 577 54 548 55 489 57 448 59 363 224 094 (HIGH) MED-LO 3.0 368 62 333 64 303 65 258 ---- 2 ---- 29 040 92 LOW 2.5 43 ---- 20 ---- 0 ---- 068 ---- 04 ---- 950 872 747 HIGH 5.0 2284 37 223 38 267 39 200 4 2007 42 898 782 672 GUIC5E*50 MED 4.0 796 47 787 48 753 49 709 50 655 5 580 50 384 (MED) MED-LO 3.5 54 55 53 56 50 57 480 58 438 59 373 294 208 LOW 3.0 32 64 298 ---- 29 ---- 260 ---- 23 ---- 7 02 00 HIGH 5.0 2458 42 2458 42 2378 43 2268 45 28 47 2060 93 8 GUIC40E*50 MED 4.0 775 58 757 58 720 59 682 6 634 63 583 500 389 (HIGH) MED-LO 3.5 488 ---- 478 ---- 457 ---- 446 ---- 425 ---- 347 289 76 LOW 3.0 289 ---- 277 ---- 252 ---- 25 ---- 89 ---- 37 052 992. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed. 3. For most jobs, about 400 CFM per ton when cooling is desirable. 4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown for air conditioning purposes only. 6 The dashed (---) areas indicate a temperature rise not recommended for this model. 7. The above chart is for U.S. furnaces installed at 0-4000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. 0 Rev.

TEMPERATURE RISE 00 90 80 70 60 50 40 30 20 600 CFM BTU OUTPUT vs TEMPERATURE RISE CHART 700 800 900 000 00 200 400 600 800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CFM x.08 x RISE BTU OUTPUT RISE = CFM.08 BLOWER PERFORMANCE SPECIFICATIONS Rev. 0 30 40 50 60 70 80 90 00 0 20 30 40 50 OUTPUT BTU/HR x 000

WIRING DIAGRAMS INDUCED DRAFT BLOWER GAS VALVE M P3 C2 BR-3 GY-2 RD- PRESSURE SWITCH C NO YL-20 OR-22 JUNCTION BOX WH -5 BK - DISCONNECT N WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNITMUST BE PROPERLY POLARIZED AND GROUNDED. L TO 5VAC/ Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE BK BK -3 WH WH -7 FLAME SENSOR BU-4 GN PK-7 MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 45K BTU) HOT SUR FACE IGNITER OR-5 RD-2 WH-33 TO 5VAC/ Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WARNING: BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. L N DISCONNECT BURNER COMPARTMENT AUTO RESET PRIMARY LIMIT CONTROL VT-28 BU-27 DOOR SWITCH LINE-H JUNCTION BOX LINE-N BLOWER COMPARTMENT DIP SWITCHES * 0 2 3 4 5 6 7 C INDOOR AIR CIRCULATION BLOWER 5 V HUMIDIFIER AND ELECTRONIC AIR CLEANER FIELD CONNNECTIONS ON ON OFF ON ON OFF OFF OFF BR INTEGRATED CONTROL MODULE BLOWER HEAT OFF DELAY SELECTOR (SECONDS) 60 80 90 60 20 20 90 80 AS SHIPPED FROM FACTORY * BR LI NE -H OR EAC-H EAC-N HUM-H HUM-N PIN JUMPER DIAGNOSTIC LED Y W R G C * STEADY ON = REPLACE CONTROL FLASH = CAPACITOR RD (LOW) OR (MED LOW) BU (MED) BK (HI) BK-4 WH SEE NOTE 4 OPTIONAL COOL-H 24V THERMOSTAT CONNECTIONS HEAT-H 5 VAC HOT AND PARK TERMINALS 0 2 7 8 9 4 5 6 2 FLASHES = PRESSURE SWITCH STUCK CLOSED 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 FLASHES = OPEN PRIMARY OR AUXILIARY LIMIT 5 FLASHES = OPEN ROLLOUT LIMIT 7 FLASHES = LOW FLAME SENSE SIGNAL SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 6 FLASHES = 5V AC POWER REVERSED OR POOR UNIT GROUND CONTINUOUS FLASHES = UNANTICIPATED FLAME PRESENT COLOR CODES: PK PINK YL YELLOW BR BROWN OR ORANGE WH WHITE VT VIOLET BU BLUE GN GREEN GY GRAY BK BLACK RD RED 2030200 REV.0 XF MR-H CONNECTOR MANUAL RESET AUXILLARY LIMIT 5 PIN WH-5 OR-0 XF MR-N PK-30E BU-27 2 OR-22 (OPTIONAL) 5 VAC NEUTRAL TERMI NALS 3 FUS E 24VAC 3A PK-30 WH-33 BK-4 WH-5 GY-8 OR-0 GY-8 WH-33 GN WH-7 LINE-N CIRC-N BK-3 RD-2 YL-20 OR-5 RD- GY-2 BR-3 GY-8 OR-0 BU-4 BK-3 5 VAC 24 VAC 40 VA TRANSFORMER WH-32 OR-0 GY-8 TH (3) LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (5V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION NOTES:. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 05 4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED. 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. BLOWER HEAT OFF DELAY IS FIXED AT 90 SECONDS WITHOUT OPTIONAL BLOWER HEAT OFF DELAY SELECTOR. DOOR SWITCH (OPEN WHEN DOOR IS OPEN) INTEGRATED CONTROL MODULE 24V THERMOSTAT CONNECTIONS R W Y G C XFMR-H (OPTIONAL) FUSE 3 A TO MICRO IND HUM-H EAC-H IGN FP (2) RO (5) RO2 () HLO () HLI (7) PS (0) MV (2) MVC (9) (8) TR (6) HEAT-H HEAT COOL COOL-H INTEGRATED CONTROL MODULE ID BLWR HUMIDIFIER ELECTRONIC AIR CLEANER INDOOR AIR CIRCULATION BLOWER HOT SURFACE IGNITER FLAME SENSOR 5 VAC 24 VAC MANUAL RESET AUXILIARY LIMIT CONTROL NO EQUIPMENT FIELD FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE 40 VA TRANSFORMER MANUAL RESET ROLLOUT LIMIT CONTROL C2 P3 M AUTO RESET PRIMARY LIMIT CONTROL C GAS VALVE HUM-N EAC-N CIR-N XFMR-N PRESSURE SWITCH INTEGRATED CONTROL MODULE TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY, OR DEATH, DISCONNECT THE POWER BEFORE SERVICING. WARNING! 2 Rev. GUIC EA (Manufacturing Numbers P23400-08F) GUIC EX (Manufacturing Numbers P2340-08F)

SCHEMATICS CIRCULATOR BLOWER 24 VAC R ELECTRONIC INDUCER AIR CLEANER HUMIDIFIER HEAT COOL PARK PARK CIR NEU EAC EAU NEU IND IND HUM NEU K2 K3.0005 3M K5 K8 FP IGN MV MV PS HLO HLI FLAME SENSOR PROBE IGNITOR GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY, OR DEATH, DISCONNECT THE POWER BEFORE SERVICING. R XFMR HOT XFMR NEU COMPRESSOR CONTACTOR COIL RO2 RO TH TR C Y G W Y G W THERMOSTAT FUSE ROLLOUT SWITCH K LINE HOT 20 VAC LINE NEU FACTORY JUMPER FACTORY JUMPER WARNING! TYPICAL SCHEMATIC GUIC EA/EX MODEL FURNACES WR 50A55 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not all wiring is as shown above, refer to the appropriate wiring diagram for the unit being serviced. 3 Rev.