End of Life -Discussion on Ex Luminaires for Fluorescent Lamps in Zone 1? Not a Problem for Us! EVG 05

Similar documents
Certificate of Compliance

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

Servicing & Maintenance. in hazardous areas

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

IECEx Certificate of Conformity

Hazardous Area Products

Industrial Hazardous Area Products

Technical Data. Dimensions

PEPPERL+FUCHS GmbH

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. Dimensions

SEK-3 Marine Grounding System

Operating Manual MS220KA and MSR220KA


Dust - a Safety Risk Why dust is an explosive subject

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Manual Power relay SR853

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Technical Data. Dimensions

IECEx Certificate of Conformity

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

UV Flame Supervision System

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

AS/NZS IEC :2013

polar zone components and systems for extreme temperatures

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

VERSAFLOW VORTEX Supplementary instructions

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

Oil Burner Controls LMO24... LMO44...

QTi DALI 1X35/49/80 DIM

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

PRODUCT DATASHEET QTi DALI 4X14/24 DIM

EU Declaration of Conformity Annex

QTi DALI 4X14/24 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

Monitoring Devices 11/1

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Oil Burner Controls LMO24... LMO44...

QTi DALI 1X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

CTS Your Partner for Customised Technical Solutions

DALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps. Approvals:

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Flame Safeguards LFE10. Building Technologies HVAC Products

QTi DALI 1X58 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T8 ECG dimmable DALI for FL 26 mm

DATASHEET. Burner control unit FDA 601x

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

INTERNATIONAL STANDARD

LGA... Gas Burner Controls. Building Technologies Division

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

QTi DALI 2X21/39 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

Proservo NMS5- / NMS7-

Procedure for the Approval of New Fire Detection and Alarm Technologies

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Explanations of Applications in Hazardous Areas

(German speaking trainers with English written slides)

Role of CE Marking in the Placing on the Market of Electronic Components

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

INTERNATIONAL STANDARD NORME INTERNATIONALE

Explosion-protected actuator Page 259 of 292

Operating Manual MS220DA

Operating Manual MS220Vi and MSR220Vi

IRceL CH4 Methane (CH 4

LAE10 LFE10. Use. Series 02

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Oil Burner Controls LOA3... Building Technologies HVAC Products

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Electronic Temperature Controller 70304,

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

EC-Declaration of Conformity Annex

Lum. Flux** [lm] 6500 K 1700 lm

Manual Isolating Barrier D461R1 (Revision 01)

INSTRUCTION MANUAL (ATEX / IECEx)

Transcription:

End of Life -Discussion on Ex Luminaires for Fluorescent Lamps in Zone 1? Not a Problem for Us! EVG 05 Tested and Certified According to the Latest Standards from March 2005

EOL (END OF LIFE) What is it? As with all other lamps, the lifetime of every fluorescent lamp is limited. Users of all Ex fluorescent light fittings reported on some critical situations where, after being in operation for longer periods, they overheated or even caught fire. It is not possible to say for certain to what extent the EOL effects were the cause of this. At the request of the German Manufacturers Association the Phsyikalisch- Technische Bundesanstalt (PTB) in Braunschweig carried out an independent investigation of this phenomenon. The results of this latest investigation have been published and can be found on either of the following Internet pages: www.explosionsschutz.ptb.de/ pruefung-plex-komp-langfeld.htm or: www.ceag.de/de/ Explosion_Protection/ Expert_Forum/ Application_Reports/ Extract from this report: In the more recent past, luminaires used in conjunction with these fluorescent lamps have been found to fail as a result of local overheating of the lamp cap and the lamp socket. There are different kinds of faults that may have led to these failures. One possible explanation is the end-of-life effect (EOL) of the lamp, which will occur only in exceptional cases at the end of the lamp lifetime. It is for the time being not possible to reproduce this EOL effect in the laboratory in a conclusive manner, but it may be described as follows in qualitatively terms...

The Solution for Zone 1 Applications CEAG EVG 05 The Solution for Zone 1 Applications CEAG EVG 05 All the EVGs (electronic ballast s) supplied by CEAG since 1988 feature monitoring of the lamp circuit, detection of the rectifier effect, as well as a shutdown of the circuit in the event that the lamp does not strike. Therefore, the CEAG EVGs already ensured a high level of safety at the service life of the lamps long before the discussions on EOL ever started. The new CEAG EVG 05 also fulfils the relevant EOL requirements of the industrial standard IEC 61347-2-3 ( 17.2 and 17.3), as well as those laid down in the latest draft of IEC 60079-7 Ed. 4 (Electrical Apparatus in the type of protection Increased Safety), issued March 2005, for luminaires for use in potentially explosive atmospheres Zone 1. Thus, the CEAG EVG 05, which is certified to: PTB 05 ATEX 2018 U, meets the latest findings and the newest standards (issue 2005). The advantages for you: Time-tested and reliable technology Latest lamp circuit monitoring as an additional safety factor Meets all requirements of the standard draft IEC 60079-7 for luminaires with fluorescent lamps in Increased Safety (EOL) EVG designed specially for rough operating conditions of Zone 1 not just an encapsulated industrial EVG Thermally optimised circuitry for long service life, even in high ambient temperatures Wide input voltage range and DC operation for universal use Two separate lamp circuits (autarkic switching) provide more safety for your employees and installations Practically insensitive to network harmonics and over-voltage influences Isolation of one lamp circuit for use in emergency lighting installations (economic battery use)

Connection diagram series EVG 05... (18 W, 36 W, 58 W) Inhibit switch for lamp circuit 1 Lamp 1 Lamp 2 (only double lamp EVG) Electrical data (T A = 25 C) (permissible tolerances accd. to EN 50014) Technical data EC-Type Examination Certificate PTB 05 ATEX 2018 U Category of application accd. to 94/9/EC II 2 G EEx ed II C Approval of the production quality assurance PTB 96 ATEX Q001-2 Supply terminal clamping capacity 0.75-2.5 mm 2 2 x per terminal Type of protection accd. to EN 60 598 II Permissible ambient temperature -20 C... +70 C Type: EVG 05... 218 136 236 158 258 Rated voltage AC 110-254 V 220-254 V Rated voltage DC 110-250 V 196-250 V Rated frequenz 50-60 Hz Operation frequenz 25-60 khz Ignition voltage (< 3 sec) 660 V max. installed load (230 V) 40 VA 40 VA 75 VA 70 VA 140 VA Output voltage at rated operation (T8-26 mm) 52 V 100 V 100 V 130 V 130 V Lamp current at rated operation 0.31 A 0.33 A 0.33 A 0.49 A 0.49 A 300 8000 2056(C)/2/04.05/SL Technical details subject to alteration. Manual valid from april 2005. Cooper Crouse-Hinds GmbH Neuer Weg-Nord 49, D-69412 Eberbach Phone: +49 (0) 62 71 806-5 00 Fax: +49 (0) 62 71 806-4 76 Internet: www.ceag.de e-mail: info-ex@ceag.de

Which Protective Circuits does the New EVG 05 have? The standard DIN EN 61347-2-3 (VDE 0712-33), which was issued in February 2005, only stipulates a permanent monitoring of the lamp circuit for EOL effects for T4 and T5 lamps (16 mm and thinner). The draft version of the standard IEC 60079-7, which was derived from this standard, lays down the test requirements for Ex-e light fittings with cold start EVGs for T6 (26 mm) fluorescent lamps. Unlike industrial luminaires with EVGs, Ex-e luminaires shall fulfil all of the relevant conditions of this standard. The CEAG EVG 05 fulfils all these requirements and, thanks to the continuous lamp monitoring, ensures the following functions: 1. Shutdown of lamps that do not strike If a fluorescent lamp does not strike correctly within 5 seconds, the start process is stopped and the lamp circuit deactivated with a power break of approx. 5 seconds. The second lamp circuit continues to function without a break. 2. Shutdown at end of life of the lamp under the most unfavourable conditions, the ageing process of the lamp electrode can lead to higher power consumption (additional voltage drop at the electrode) and a temperature rise. All the EVGs in the EVG 05 range continuously monitor this process and safely limit the power as given in the standards draft IEC 60079-7, Pmax = 10 W, by shutting down the lamp circuit. EN 61347-2-3 lays down three different test procedures for simulating the end of life of fluorescent lamps. The first test procedure (monitoring for coil breakage) cannot be used for Zone 1 Ex light fittings, because in this case the coils are short-circuited. The new EVG series EVG 05... implements both the other conditions using the following two monitoring methods: a) Asymmetric power test The lamp voltage and the resulting power at the lamp increases at the end of the life of the fluorescent lamp. This increase is monitored continuously and when the limit (10 W) is exceeded, the respective lamp circuit is shut down. The second lamp circuit continues to function without a break. b) Asymmetric pulse test A further characteristic for the end of life of a fluorescent lamp is the flickering of the lamp. To recognise this effect, an asymmetric pulse test (.) is simulated, whereby all the EVG 05 units shut down the lamp circuit within 30 seconds. The second lamp circuit continues to function without a break.

The EVG 05 in Practice: Explosion Protected Luminaires with Trademark CEAG All these functions are just one component in the extensive safety concept of the CEAG EVG 05. The use of high impact resistant plastic materials for the encapsulation in the type of protection EEx-de, as well as the additional unit fuses for the event that a fault occurs rounds off the whole package. The new CEAG EVG 05 will become standard for our fluorescent light fittings series: ellk 92.../.. ellm 92.../.. ellk 92.../.. NIB as well as the flush mounting fitting ellb 20... Thus, as of May 2005, all luminaires supplied will be to the newest standard. Naturally all existing luminaires can still be used without any limitation. The investigation report from the PTB explicitly states: Quote: Measures as part of the operating instructions The measures mentioned are intended for newly issued certificates. This is to allow any insights gained to be used for technical improvements. The assessment of potential ignition risks, and the number of faults that have been identified to the present day, do not justify the requirement of having previously certified luminaires of category 2G (zone 1) and category 3G (zone 2) retrofitted or converted. Have we awoken your interest? Then look under www.ceag.de for your local sales engineer. Or send us a mail to: info-ex@ceag.de We will be pleased to help you. Apart from these equipment-specific measures, there are no special maintenance requirements in addition to the normally required manufacturer s specification...