Model:7530. Specifications. Model ~13.8 FAX: TEL: painting parts. (V) (CFM) System (A) (RPM)

Similar documents
CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

an ISO 9001 Company Bulletin PR-112

CML Northem Blower Inc. Air Movement Equipment

Varius Application of Dynair Fans

INDUSTRIAL CLEANING AND FINISHING SYSTEMS

fans & heaters SIMPLE, ROBUST AND RELIABLE

PARTS DRYING & BLOW-OFF

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Centrifugal Fans, Non-Overloading, Backward Inclined

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

SHN/SG SERIES ELECTROSTATIC MIST COLLECTORS. Clean air. It s what we do.

Air Make-Up Units. Product Line Overview & Capabilities


Industrial Ventilation: It s not just Blowing Smoke! Eric Anderson, M.S., P.E.

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Selecting the Correct Fan

DAE Systems. Fan Selection Guide. Section 1: Terminology

Twin City Fan & Blower

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

Direct Fired Heater Model AD Specification

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

R. K. Engg. Works Private Limited

STAINLESS STEEL EVAPORATIVE CONDENSER

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Cleantek.

Indirect Gas-Fired Make-Up Air

Clean. Easy. COMPLIANT.

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

SHIPWIDE VENTILATION BUYING GUIDE

Quality & Service Since For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Multistage Centrifugal Blowers

LARGE CAPACITY HEATERS

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Combustible Dust Issues

2017 INDUSTRIAL FAN CATALOG

SKYPAK II, 3 Ton Series, gives you a

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Multistage Centrifugal Blowers

Hindustan Blowers.

MADE IN THE USA FOUNDRY & FORGING AIRLESS SHOT BLAST & PARTS WASHING EQUIPMENT

SKYPAK II, 3 Ton Series, gives you a

TYPICAL CPA SPECIFICATIONS

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Explosion Proof Ventilation Fan Redirects Stale Air From Hazardous Location Areas

Our Honesty. Our Expertise. Your Safety.

Comprehensive Catalog of Environmental Equipment

Keller USA, Inc. Filtration of emissions. Capturing & extraction of process emissions. Return of clean air

EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Cooling Module. Cooling Fans. Cooling Fans F-105. FM Series IP55/43. Introduction MRS. Variable Flow MRS

PRE-BATCHER UNIT DRYER UNIT. Model: RM 350. Year of construction: Composed of:

Multistage Centrifugal Blowers

Ship-Wide Ventilation Systems

hinged tops or hinged doors.

Bowker Machinery Ltd

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

CombiBloc Close-coupled centrifugal pumps

DALAMATIC DUST COLLECTORS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

AiRTX Static Elimination

2016 INDUSTRIAL FAN CATALOG

K Series. rogers-kseries.com RMC-K-BROCHURE_REV.002 Record of Change A/B. Fixed Speed. Lubricant-Injected Air or Water-Cooled

YORK COMMERCIAL AND INDUSTRIAL SUPPLY AND EXHAUST FANS. YORK Commercial and Industrial Supply and Exhaust Fans. Creating air-flow efficiencies

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PRO JET RANGE FOR A PRODUCTIVE, CLEAN & HEALTHY WORK ENVIRONMENT

EC Fans Growing in Popularity

B.K. Machinery (M) Sdn. Bhd. Submersible Pumps. Flexible Vibrator Poker. 1 of 6. Other Construction Machinery

FT900BD FLIGHT-TYPE DISHWASHER

General Purpose Ventilation Fan - Venturi-Style Blower PSIG

Energy Efficient Fan and Dust Collection Systems

Why Cooltron Fans & Heat Sinks? By Steven Chiang

ENVIRO INTERNATIONAL CORPORATION

Parts Washers, Water Pumps, special applications

Comprehensive Catalog of Environmental Equipment

Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

Fan Blades & Accessories

Models SCA and SCB. ceiling-mount cartridge dust collectors. Model SCA. Model SCB

EWHA MACHINERY CO LTD. CE & ISO9001 Certificated

Confined Space Ventilation equipment

RGE 13 A T - 1 A

Specifying a Dust Collector For a School Wood Shop

Transcription:

Blower Fan series Model:7530 Blower Fan application highlights: Paint spray booth exhaust. Fume hood exhaust. Exhausting dangerous fume away from the operator. Welding fume exhaust for welding booths. Process cooling and exhaust of machinery and/or systems. People cooling in hot work areas. Forced cooling and exhausting heat in steel mills. Forced cooling for kilns, ovens and forges. Exhausting mist and vapor in paper mills or industrial parts washers prior to painting parts. General ventilation using supply air and make-up air in factories, foundries and warehouses. Model Specifications Operation Voltage Rated Current Rated Speed Air Speed Static Pressure Noise Bering Rated Voltage (V) (V) (A) (RPM) (CFM) (mmh2o) (dba) System YHWF-7530H 0.3 3800 25.6 5.2 38 Sleeve 12 10.2~13.8 13.8 YHWF-7530M 0.45 3500 28.5 4.32 35 Sleeve YHWF-7530M 7530M-1 24 22.2~25.8 25.8 0.5 3800 35.5 5.2 38 Sleeve Website Http://www.yuhong-micromotor.com.cn Manufacturer:DONGGUAN YUHONG MICROMOTOR CO.,LTD Address:NO.135 Qingfeng East Road Shijie town of Dongguan Zip Code:523300 TEL:+86-769 769-87065497 FAX:+86-769 769-86376718 ISO9001:2000

注册号 :CNAB048-Q 1: blowers fan used in heating, ventilation and air-conditioning (HVAC) and boiler applications generally represent over half the total energy consumed in commercial buildings and are often oversized to account for contingencies. 2: 3: 4: 5: APPLICATIONS: While a list of all the applications industrial fans and blowers are used for would be extremely long, the most com Centrifugal Fans & Blowers: Conveying material in dust collector systems or loading to silos, trucks and railroad cars. Combustion air for burners and industrial water heaters. Cooling electrical equipment or parts from heat curing ovens and kilns. Pressurizing cabinets, vaults or rooms. Blow-off systems to remove moisture from parts prior to painting, coating or packing. General ventilation of rooms or factories. Providing suction or pressure for industrial process air flotation tables. Drying ink on cans and bottles, silk screen and printing processes. Food processing. Circulating air in ovens and dryers to eliminate cold spots. Forced ventilation of AC and DC motors, traction motors and electrical cabinets. Industrial Axial Fans: Paint spray booth exhaust. Fume hood exhaust. Exhausting dangerous fume away from the operator. Welding fume exhaust for welding booths. Process cooling and exhaust of machinery and/or systems. People cooling in hot work areas. Forced cooling and exhausting heat in steel mills. Forced cooling for kilns, ovens and forges. Exhausting mist and vapor in paper mills or industrial parts washers prior to painting parts. General ventilation using supply air and make-up air in factories, foundries and warehouses. Call us or our sales office for your area. We most likely have already built industrial fans and blowers for your ap BENEFITS: The benefits of Cincinnati Fan industrial fans and blowers are: Most all types and models, with most accessories, are shipped within 10-15 working days. Some models av Spark resistant, cast aluminum wheels are standard in our PB and SPB Models and cast aluminum props are Heavy duty, industrial components and continuous duty motors ensures long lasting operation minimizing equ All aluminum or all stainless steel fan construction is not special for us. We manufacture most models with All of our centrifugal blowers and fans are available with multiple wheel sizes and some are also available with Less expensive, more compact and lighter weight. Design flexibility. Belt driven models utilize wider spacing between the fan bearings which increases the bearing life. Less down Service! Without it, all the above is meaningless. We pride ourselves and are highly respected in the fan ind

mmon are: pplication. available on a 5 Day RUSH program, with most accessories. Quicker than industry standards. re standard in most of our Axial Fan Models. Ideal for applications requiring any spark resistant requirem uipment down time. Dependable service with few field problems. h both types of construction almost weekly. Faster delivery to you. h multiple housing widths from 50 to 100% in 5% increments. Direct driven fans can be selected instead of larger, wn time before replacement bearings are needed. ndustry for the quality and service we give all our customers. Let us prove it to you also.

ment and quick deliveries., heavier, more expensive belt driven fans.