CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT

Similar documents
MSC Guidelines for Foam Fire Suppression Systems

Crosswalk: Weight-Based Rating versus Performance-Based Rating

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

Fire Prevention Plan Program

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Capital Projects Group Fire Extinguishers Specification

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

MSC Guidelines for Automatic Sprinkler Systems

UNIFIED INTERPRETATION OF PROVISIONS OF IMO SAFETY, SECURITY, AND ENVIRONMENT-RELATED CONVENTIONS

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

Fact File 78. Portable Fire Extinguishers under the ADR. Note: This Fact File supersedes Fact File 060 which is withdrawn

Changes for the New Edition. Senior Engineer, NFPA NFPA

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

Fire Control Fire Extinguisher (FC5)

CERTIFICATE OF FIRE APPROVAL

Z86 Safety-Plus Industrial Cleaner Concentrate

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

Executive Summary. Shell Offshore Inc. BY: Keith M. Gonzales Sr., P.E. Regulatory Requirements for Hazardous Locations

NFPA Marine Fire Protection Codes and Standards An Overview. Guy R. Colonna, P.E. National Fire Protection Association. Quincy, MA USA

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

Requirements. This Toolbox Talk has been created to assist you, and the user to assess the building Occupancy and classification.

A Bridge to Inspection

Guide to choosing the right portable Fire Extinguisher. Produced in association with the UK Fire Association

Emergency response lock box unit contents and maintenance.

Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel

Portable Fire Extinguishers

d. Portable water heaters used exclusively for underwater diving operations.

Information Bulletin

COMMISSION DELEGATED REGULATION (EU) No /.. of

SELF PRESERVATION SOCIETY By Jim Creak

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

MSC Guidelines for Vital System Automation Procedure Number: E2-01 Revision Date: 11/10/2011

UNIFIED INTERPRETATIONS OF SOLAS CHAPTER II-2, THE FSS CODE, THE FTP CODE AND RELATED FIRE TEST PROCEDURES ***

What are the four things that must be present at the same time to produce fire?

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

Australian Standard. Fire protection for mobile and transportable equipment AS AS

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

ARTICLE 25. FUEL GAS CODE

ORDINANCE NO WHEREAS, the City provided the proposed code amendments to the Washington State Department of Commerce on September 20, 2017; and

IMO MSC 94 Summary Report on Polar Code

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

COMDTPUB P NVIC JUNE 1995

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

SUBMITTAL SCHEDULE & DATA

Fire fighting Questions

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

UNIFIED FACILITIES GUIDE SPECIFICATIONS

2. Directives Affected. Reference (b). is hereby superseded.

Airworthiness Directives; Kidde Aerospace Part Number (P/N) Hand-Held Halon Fire Extinguishers

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Australian/New Zealand Standard

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Pre-First Draft Meeting Technical Committee on Wastewater Treatment Plants On line/conference Call November 20, PM EDT

BUILDING CODE INTERPRETATION

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

A Guide for Meeting NFPA 10 Subsection

Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

TAMUCC Fire Safety Training

HEALTH AND SAFETY INDUCTION CHECKLIST

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Fire Extinguisher Training

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

PRELIMINARY PUBLIC NOTICE 1-161

INTERNATIONAL STANDARD

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

SOUTH AFRICAN NATIONAL STANDARD

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Institute for Plasma Research Welcomes you all on

Fire fighting Portable fire extinguishers Performance and construction

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Fixed Fire Extinguishing Equipment and Systems

Subj: CH-1 TO NVIC 08-04; GUIDE TO MARINE EQUIPMENT APPROVALS COVERED BY US - EC MRA & BY US - EEA EFTA MRA

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

June 2018 Safety Meeting Fire Extinguishers Part I

MATERIAL SAFETY DATA SHEET 3M Earloop Fluid Resistant Face Mask Cat. # 1820, 1820FS 09/18/12

EMERGENCY PHONE: or (651) (24 hours)

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

RESOLUTION MSC.145(77) (adopted on 5 June 2003) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS

EMERGENCY PHONE: or (651) (24 hours)

APPENDIX 112D. PERCHLOROETHYLENE DRY CLEANING NESHAP (40 CFR 63 Subpart M) CAA SECTION 112 NESHAP

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

fire risk assessment For use by landlords of small premises Premises Address

Applicable international instruments for construction, performance and testing requirements 1

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

EMERGENCY PHONE: or (651) (24 hours)

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

Transcription:

March 1, 2018 CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT SUBJECT: EVALUATION OF EXISTING COAST GUARD REGULATIONS, GUIDANCE DOCUMENTS, INTERPRETATIVE DOCUMENTS, AND COLLECTIONS OF INFORMATION IDENTIFICATION DETAILS OF REGUALTION, GUIDANCE OR INFORMATION COLLECTION (BY SECTION, PARAGRAPH, SENTENCE, CLAUSE, ETC.): Existing regulation Proposed regulation Guidance Collection of information 46 CFR 28.160 Portable fire extinguishers. ADVICE AND RECOMMENDATIONS: Repeal Replace Modification Discussion: The USCG recently updated marine portable fire extinguisher carriage requirements utilizing standard classification that is used by non-marine industry. The old carriage requirements were:

The new carriage requirements are:

Under the old carriage requirements, C-I classified extinguishers satisfied the Pilothouse carriage requirements. Many mariners complied with the regulations utilizing liquefied gas type fire extinguishers or carbon dioxide fire extinguishers because of their low residue properties appropriate for use around critical electronics in the pilothouse of a vessel. These electronics are used in all manner of vessel control, systems and area monitoring, situational monitors such as radar and depth sounder and in the communications equipment. Carriage of the liquefied gas type or carbon dioxide fire extinguishers in the pilot house reduce the risk to all this vital equipment compared to carrying other types of extinguishing agent. Dry chemical extinguishing agent is corrosive and its presents is a hazard to electronic equipment. Under the old carriage requirements, classification B-II portable extinguishers satisfied regulations for, and were appropriate for the hazard of, internal combustion machinery spaces. Classification C-II portable extinguishers satisfied regulations for, and were appropriate for the hazards of, electric generator and / or motor space. Many mariners complied with the carriage requirements for these machinery spaces utilizing portable carbon dioxide fire extinguishers. These extinguishers are appropriate for these machinery spaces because of their low residue properties, their under the floorboards capabilities, the capability to pull the pin, lock the discharge mechanism in the discharge position and throw it in, and allowing the capability to stop a runaway internal combustion engines by replacing the air the engine is taking in with carbon dioxide and disrupting the combustion process.

According to the new carriage requirements, a minimum required rating of 20-B:C is necessary in the pilothouse. Neither the 5lb. liquefied gas extinguisher or the 15 lb. or 20 lb. carbon dioxide extinguisher meets the updated requirements. These extinguishers are rated as a 10-B:C under this classification but have been the most appropriate for use in the pilothouses of vessels for many years. According to the new carriage requirements portable fire extinguishers with a classification of 40-B:C are needed for machinery spaces. The 15 lb. and 20 lb. carbon dioxide portable extinguishers, are perfectly appropriate for these machinery spaces but are classified as 10-B:C under the new classification. The carbon dioxide extinguishers no longer meet USCG updated carriage requirements. The new regulations are causing vessels to carry portable dry chemical extinguishers in machinery spaces where they may not be appropriate and in fact may be unnecessarily risking introducing a hazard into the vessel environment that would be hazardous to critical vessel systems. It is the recommendation of this committee that the USCG review their carriage requirements and modify them so that they allow the liquefied gas

type and carbon dioxide type portable fire extinguishers where a B, C or B:C type extinguisher is appropriate. IF MODIFICATION - SPECIFIC RECOMMENDATIONS FOR HOW THE REGUALTION, GUIDANCE, OR INFORMATION COLLECTION SHOULD BE MODIFIED: Marine portable fire extinguisher carriage regulations should have appropriate minimum required ratings for liquefied gas type extinguishers or carbon dioxide extinguishers for machinery spaces where a C or B:C extinguisher is appropriate. HOW AND TO WHAT EXTENT REPEAL, REPLACEMENT OR MODIFICATION WILL REDUCE COSTS OR BURDENS TO INDUSTRY: Types of costs mark all that apply Costs that are outdated or are no longer necessary Costs which are no longer enforced as written or which are ineffective Costs tied to reporting or recordkeeping requirements that impose burdens that exceed benefits (explain why the reporting or recordkeeping requirement is overly burdensome, unnecessary, or how it could be modified) The requirement modifications made while switching from the old marine rating system to the new universal classification system did not ensure that all types of extinguishing agents appropriate for the hazard and of appropriate size for the space were included in the amended minimum required rating. Vessel operators are mounting dry chemical extinguishers in the engine room and pilot house at the risk of critical electronic equipment to satisfy requirements while carrying additional USCG approved portable extinguishers of the liquefied gas type and carbon dioxide type to use in case of fire. THE EXTENT TO WHICH RISKS TO HEALTH OR SAFETY WOULD LIKELY INCREASE: None. HOW AND TO WHAT EXTENT THE REGULATION, GUIDANCE, OR INFORMATION COLLECTION HAS LED TO THE ELIMINATION OF JOBS OR INHIBITS JOB CREATION: N/a

PROVIDE QUANTITATIVE AND/OR QUALITATIVE DATA TO SUPPORT AND ILLUSTRATE THE IMPACT, COST, OR BURDEN, AS APPLICABLE. IF THE DATA IS NOT READILY AVAILABLE INCLUDE INFORMATION AS TO HOW SUCH INFORMATION CAN BE OBTAINED BY THE COMMITTEE OR THE COAST GUARD The USCG marine portable fire extinguisher classification data for USCG approved equipment is not readily available because it is kept in UL databases. The availability of this data is very limited, especially compared to the ability to access and sort data through the CGMIX searchable listings of equipment and materials approved or certified by the US Coast Guard for use on commercial vessels and recreational boats. The UL performs equipment testing for portable fire extinguishers and other services for the Coast Guard but portable fire equipment data should be kept in the CGMIX databases. This would allow the USCG, researchers and the public to have the ability to access and sort portable fire extinguisher data through the CGMIX searchable listings of equipment and materials approved or certified by the US Coast Guard like other approved or certified equipment. A complete analysis should be completed to compare all fire extinguishers of varying agent type and size that were approved and appropriate under the old marine classification system, 46 CFR 28.160, to the fire extinguishers available under the revised classification system.