Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Similar documents
FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

SINGLE-ROOM VENTILATION. for schools and public spaces

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

Series VENTS VUT R WH ЕС

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY VENTILATOR

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

INTELLIGENT AXIAL FAN user's manual

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

AIR HANDLING UNIT WITH HEAT RECOVERY

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

COMMERCIAL VENTILATION

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air handling units with an integrated heat pump and rotary heat exchanger

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

Heat Recovery Air Handling Units

VENTILATION & HEATING CATALOGUE.

Model with intellectual humidity control and extra motion sensor control

Ventilation Unit Zehnder ComfoAir 350

Ventilation unit Zehnder ComfoAir 200

Lo-Carbon Sentinel Kinetic Horizontal

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

HEAT RECOVERY AIR HANDLING UNIT

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Heat recovery unit RDKS

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Installation manual Mini Comfort 50 S/L 07/ V EN

NEW GREEN TECHNOLOGY

ENERGY RECOVERY VENTILATION (ERV)

Mini fans MiniVent M1/100

GB User and maintenance manual

Energy Recovery, Wholehouse Ventilation ECO LIVING

Domestic & Commercial Fans

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Caution: The fans must not be used in bath or shower enclosures.

Limited Lifetime core warranty. 5-year warranty on balance of unit.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

User and maintenance manual

HRV Enthalpy. Catalogue

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

A B C D E F 2

HOTLINE:

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

QZB "Standard" comfort fan coil

Zehnder ComfoAir 550. Ventilation unit

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Ventilation and Hand Dryers

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Flexit air handling units C2 and UNI 2, 3,4

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Outside Air Requirements... SOLVED!

Transcription:

c a i r c im M Si l g n e r m o o ai a h r r ving i a a ze h s gy s t si e Fr e r p a c En m Co a r th i y w r t s ov e i un rec g t n li ea d n h in t e til oun a rs m ise e V sy no Ea w Lo g

Industrial and commercial ventilation (Catalogue no. 1) Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units with heat recovery, air heating units, accessories. Energy saving supply and exhaust units and air handling units with heat recovery with air capacity up to 6500 m3/h. Smoke extraction and ventilation (Catalogue no. 5) Domestic ventilation (Catalogue no. 6) Smoke protection systems of buildings and premises. Domestic ventilation: fans, mono-pipe exhaust kitchen and bathroom fans, air distribution units, air ducts and fittings, access doors, ventilation kits. Air distribution units (Catalogue no. 9) Access doors (Catalogue no. 10) Plastic and metal air distribution products (grilles, disk valves, diffusers, etc.) for ventilation, air conditioning and heating. Plastic and metal access doors for accessing concealed equipment and utility lines. Special offers for ceramic tiles. Spirally wound ducts (Catalogue no. 13) Flexible ducts and fittings for ventilation, air conditioning and heating (Catalogue no. 14) SPIROVENT spiral seam vent ducts and fittings of 100 to 1600 mm diameter. Flexible and semi-flexible air ducts made of polymeric materials, aluminium, galvanized or stainless steel, metal fittings for ventilation, air conditioning, heating, gas handling and abrasive particles aspiration. 2

Air handling units AirVENTS (Catalogue no. 3) Energy saving ventilation Geothermal systems GEO VENTS (Catalogue no. 4) Energy saving air handling units with air capacity up to 40 000 m3/h, for use in large residential, industrial and commercial objects. Energy saving system GEO VENTS with use of the earth s surface layers heat. High ventilation system energy efficiency and low operating costs. Domestic fans (Catalogue no. 7) VENTS VN Mono-pipe exhaust ventilation (Catalogue no. 8) Domestic fans with air capacity up to 365 m3/h with extra functions: timer, humidity sensor, motion sensor, etc. Applied for premises up to 30 m2. Exhaust ventilation in houses with mono-pipe ventilation system based on VENTS VN fans. Energy saving ventilation. Single room energy recovery ventilators MICRA. (Catalogue no.11) VENTS presentation catalogue (Catalogue no.12) VENTS mission is to bring fresh air to your house and surround you with the world of comfortable microclimate. MICRA single room ventilators with energy regeneration for efficient ventilation and lowest investments in ready-built and brand new premises. Round and flat PVC ducting (Catalogue no. 15) Energy saving ventilation. Single room energy recovery ventilators TwinFresh. (Catalogue no.16) Flat and round PVC ducts PLASTIVENT for ventilation of residential, office and commercial premises and connection of exhaust ventilation equipment (kitchen extractors, hoods, exhaust boxes, etc). Wide product range of fittings. Single room reverse ventilators with energy regeneration TwinFresh for efficient ventilation and lowest investments in ready-built and brand new premises. 2017 3

SINGLE ROOM ENERGY-SAVING VENTILATION MICRA 100 Micra 100 is a single-room energy-efficient supply and exhaust unit intended for decentralised ventilation of residential and commercial spaces as well as apartments and houses. This air handling unit is ideally suited for creating simple yet highly efficient ventilation systems in newly erected and renovated spaces without requiring ducting installation. FEATURES Efficient solution for supply and exhaust ventilation of enclosed spaces Electric pre-heater or post-heater variant available for cold climate conditions Heat exchanger with an enthalpy membrane variant available for humid and hot climate conditions Low-energy ЕС fans Excellent noise control (25-38 dba) Supply air purification ensured by two built-in G4 and F8 filters (optional H13) Upgradeable with an exhaust duct to provide air extraction from the bathroom Easy installation Compact size Modern design DESIGN Limit switch Supply fan Extract filter G4 Counter-flow heat exchanger Supply filter F8 Supply air post-heating (Micra 100 E1) Control unit Supply filter G4 Exhaust louvre shutters with automatic drive Extract fan Supply air pre-heating (Micra 100 E) Supply louvre shutters with automatic drive Drain pan CASING Polymer coated metal casing decorated with an acrylic front panel. Thanks to the modern design the unit can seamlessly blend with most any interior design. Heat and sound insulation is ensured by a layer of 10 mm cellular synthetic rubber. The front panel provides convenient access for filter maintenance and has a lock for extra security. The unit has two ø 100 mm inlet and outlet pipes for fresh air intake and stale air extraction outside. The third ø 100 mm pipe (included) can be additionally fitted to the unit to connect the exhaust air duct from the bathroom. AIR DAMPERS The unit is equipped with supply and exhaust air dampers which activate automatically to prevent drafts while the unit is off. 4

AIR FILTRATION Supply air cleaning is provided by G4 and F8 panel filters (PM2.5 > 75 %). To meet more stringent air purity requirements an F8 filter can be replaced with an H13 (PM2.5 > 95 %) (purchased separately). Extract air is cleaned by a panel-type G4 filter. FANS The units feature efficient electronically commutated (ЕС) motors with external rotor and impellers with forward curved blades. These state-of-the-art motors offer the very best in energy efficiency today. EC motors are characterised with high performance and optimum control across the entire speed range. In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %. NE MICRA 100 HEATER FOR CONDENSATE FREEZING PROTECTION (OPTIONAL) Operation in a cold climate may result in condensate freezing in the exhaust air duct and the external hood. Therefore, it is recommended to install the NE Micra 100 heater (purchased separately) to prevent icing. PRE-HEATING Micra 100 units are equipped with an electric pre-heater which protects the heat exchanger from freezing. POST-HEATING Micra 100 E1 units feature an electric post-heater to raise the supply air temperature as necessary. HEAT EXCHANGER Micra 100 units are equipped with a counter-flow heat exchanger with a polystyrene core. In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses. However, this process may be associated with condensation which is collected in a special drain pan and evacuated outside via the exhaust air duct. In the warm season the ambient air heat is transferred to the exhaust air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load. Micra 100 ERV units are equipped with a counter-flow heat exchanger with an enthalpy membrane. In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses from ventilation. Consequently, it is the ambient air heat and moisture transferred to the exhaust air stream through the enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load. 5

SINGLE ROOM ENERGY-SAVING VENTILATION OPERATING LOGIC EXTRACT AIR SUPPLY AIR INTAKE AIR EXHAUST AIR CONTROL AND AUTOMATION Freeze protection There are two types of freeze protection available to protect the heat exchangers in the cold season. Micra 100 features an exhaust air temperature sensor downstream of the heat exchanger which disables the supply fan to let the warm exhaust air raise the heat exchanger temperature. Once the heat exchanger temperature has returned to normal, the supply fan is re-enabled and the unit reverts to normal operation. Micra 100 E units are equipped with an electric pre-heater which warms up the supply air upstream of the heat exchanger to prevent its freezing. These features ensure a continuous balanced air exchange regardless of ambient air temperature variations. Control The units are equipped with a control panel. Remote control panels are supplied as standard. Пульт ДУ (ИК) Following functions are available: Micra 100 Micra 100 E Micra 100 E1 Speed selection + + Filter replacement indication + + Alarm indication + + Speed setup + + Timer + + Weekly schedule + + Post-heating enabled/disabled - + Supply air temperature setup - + 6

TECHNICAL DATA Technical data Micra 100 Micra 100 E Micra 100 E1 Maximum air capacity [m 3 /h] 30 60 100 30 60 100 30 60 100 Unit voltage [V/50 (60) Hz] 1 ~ 110-240 1 ~ 220-240 1 ~ 220-240 Maximum fan power [W] 12 21 45 12 21 45 12 21 45 Sound pressure level at 3 m(1m) distance [dba] 13 27 39 13 27 39 13 27 39 Electric pre-heater power [W] - 600 - Electric post-heater power [W] - - 350 Maximum unit current (without an electric heater) [A] 0.35 0.35 0.35 Maximum unit current (with an electric heater) [A] - 3.08 1.94 Transported air temperature [ С] from -25 up to +50 Casing material Painted steel Insulation foam rubber, 10 mm Heat recovery efficiency [%] 96 92 87 96 92 87 96 92 87 Heat exchanger type counter-flow counter-flow counter-flow Heat exchanger material polystyrene polystyrene polystyrene Supply filter G4, F8 G4, F8 G4 Extract filter G4 Connected air duct diameter [mm] Ø 100 Weight [kg] 27.6 28 27.8 Energy efficiency class A A A Technical data Micra 100 ERV Micra 100 E ERV Micra 100 E1 ERV Maximum air capacity [m 3 /h] 30 60 100 30 60 100 30 60 100 Unit voltage [V/50(60) Hz] 1 ~ 110-240 1 ~ 220-240 1 ~ 220-240 Maximum fan power [W] 12 21 45 12 21 45 12 21 45 Sound pressure level at 3 m(1m) distance [dba] 13 27 39 13 27 39 13 27 39 Electric pre-heater power [W] - 600 - Electric post-heater power [W] - - 350 Maximum unit current (without an electric heater) [A] 0.35 0.35 0.35 Maximum unit current (with an electric heater) [A] - 3.08 1.94 Transported air temperature [ С] from -25 up to +50 Casing material Painted steel Insulation foam rubber, 10 mm Heat recovery efficiency [%] 90 86 80 90 86 80 90 86 80 Heat exchanger type counter-flow counter-flow counter-flow Heat exchanger material enthalpy membrane enthalpy membrane enthalpy membrane Supply filter G4, F8 G4, F8 G4 Extract filter G4 Connected air duct diameter [mm] Ø 100 Weight [kg] 27.6 28 27.8 Energy efficiency class A A A 7

SINGLE ROOM ENERGY-SAVING VENTILATION OVERALL DIMENSIONS 100 3 holes 650 550 257 200 400 8

APPLICATION OPTIONS Each space requiring proper ventilation is equipped with a single or several Micra 100 units. A single unit is capable of ensuring efficient ventilation in spaces with floor area up to 100 m2. Micra 100 units can be upgraded with a bathroom exhaust air duct. To enable such a configuration the units can be additionally equipped with the optional ø 100 mm fitting pipe (supplied as standard). Micra 100 deployment in a compact residential space. Plastivent Bathroom anemostat Micra 100 Door grille 9

SINGLE ROOM ENERGY-SAVING VENTILATION Micra 100 application in an office space ifan Door grille Micra 100 10

ACCESSORIES MK Micra 100 white MK Micra 100 chrome Name Picture Description Mounting kit: Two plastic Ø 100 mm air ducts 500 mm long Outdoor box (white) Cardboard template Mounting kit: Two plastic Ø 100 mm air ducts 500 mm long Outdoor box made of hairline stainless steel Cardboard template NB Micra 100 white Outdoor box (white) NB Micra 100 chrome Outdoor box made of hairline stainless steel NE Micra 100 Heater to prevent condensate freezing in the drain pipe and the outdoor box SF 193x158x18 G4 PPI G4 filter SF 193x158x47 F8 F8 filter SF 193x158x47 F8 C F8 carbon filter SF 193x158x47 H13 H13 HEPA filter HR-S Regin HR-S humidity sensor CO2-1 СО 2 sensor with air quality indication and On/Off button CO2-2 CO 2 sensor VL R6 366/157 Summer block 11

VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products features, designs, components and specifications at any time and without notice to maintain the development and quality of manufactured goods. 05/2017