Magnaflux-Zyglo Modular FPI Inspection System

Similar documents
fluorescent penetrant inspection system RELIABLE IDENTIFICATION OF SURFACE DISCONTIUITIES LOW COST, MODULAR SYSTEM

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

Lubrication Tools and Equipment Portable Oil Drains

Dishwashers. 1 electrolux dishwashers. Undercounter, Hood type, Pot and pan, and Rack Conveyor

Used Fluid Handling Portable Used-Oil Gravity Drains

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Packed With Features. Smart Pulsar controls are conveniently

Standard Features. Performance/Capacities

Packed With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated.

Models. Options. Standard Features. LoH 2 O

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

Used Fluid Handling Portable Used Oil Gravity Drains

Acrison. Polymair. Model 500 Polyelectrolyte Preparation System. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

FT900BD FLIGHT-TYPE DISHWASHER

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

PERFORMANCE SPECIFICATION

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

Competitor Series Dryers

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

"ESDDR" Series Electric Humidifier

Installation Instructions Wall Ovens

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

FT900 FLIGHT-TYPE DISHWASHER

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Section 13. Vehicle Maintenance & Detailing Equipment. Section 13: Suppliers: CALL:

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Compact Rack Type Dishwashers

MIST MAX MODEL MM800. Important: Installation and Operation Manual

Competitor Series Dryers

5) Do not start or stop the unit by inserting or pulling out the power plug.

Using Portable Spot Air Conditioners in Industrial Applications

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

FT1000 FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

UW50 UTENSIL/PAN WASHER

FT900S FLIGHT-TYPE DISHWASHER

Vacuum drying oven for non-flammable solvents

C44A/C44AW DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

Safety vacuum drying oven for flammable solvents

SERVICE MANUAL FOR MODEL RM-10

MIST MAX MODEL MM2400. Important: Installation and Operation Manual

CL64T INDUSTRIAL TOTE WASHER

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

DISHWASHERS EI24ID30Q W / B

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

CLe-series Dishwashers

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR MODEL RM-26

GIRTON CABINET WASHER MODEL 794A

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Signature Features. Stainless Steel Interior. Quiet Dishwasher. Delay Start. Multiple-Cycle Options. More Easy-To-Use Features. Product Dimensions

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

Our Purifier systems

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

D R Y P O L Y M E R P R O C E S S I N G NORCHEM

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

KOCH Curtain Coaters

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

Version 7 1/ LX

Version 7 1/ LXP

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

K Tronic Series Installation and Start Up Checkout Procedure.

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

IONIZING AIR BLOWER INSTRUCTION MANUAL

Warewashing Contents. NT & TAS - For orders in these states please add 5% transport surcharge to your purchase price

W-150-IS Specifications

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

INDUSTRIAL CLEANING AND FINISHING SYSTEMS

REQUIREMENTS FOR HOOD PLANS


STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

Inspection Checklist Mechanical Rough in

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

CULINARY OPERATIONS September 30, 2010

BASIL 6000 TUNNEL CAGE WASHER

High Profile Evaporator

ANY WASHER FOR ANY NEED.

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

The Economical Approach to Specialized Finishing and Surface Preparation

Tall-Tub Design. Our large capacity, tall-tub dishwasher fits up to 12 place settings so you can wash more at once. SpaceWise Silverware Basket

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

ZERO Economy Blast Cabinets

Transcription:

Magnaflux-Zyglo Modular FPI Inspection System This FPI system was removed from working service in 2008 and consists of the following items: 1. 1-4040 Penetrant Application Station with Optional Power Immersion Grille 2. 4-4040 Rest Station Drain Grilles 3. 1-4040 Table-Top Rinse Station (115V, 1P, 4A) 4. 1-4040 Dryer Station (480V, 3P, 16A) 5. 1-5472 Inspection Station (115V, 1P, 10A) note- this will require new curtains 6. 1-Swirl Cloud Developer Station Model 4040 480V Dryer Station

Penetrant Station with Power Immersion Grille Rinse Station

STATION EMULSIFIER STATION (LIPOPILIC WET DEVELOPER METOD) STATION IMMERSION TANK Immersion is the process normally used to apply Penetrant, Emulsifier and Wet Developer to parts surfaces. Depending on part size, a tank from one of the four modular size systems is used for the immersion process. The use of a Power Immersion Grille(see page 14) to lower and raise large parts or baskets of parts in and out of the tank will slightly affect part clearance. (See chart below.) eavy gauge stainless steel tank Bottom supported tank Protective hinged tank cover Rapid and complete coverage of parts with complex shapes Easier coverage of parts processed in bulk Easy handling of large or heavy parts using optional power immersion grille Fast, easy installation (floor mount or bolt-together) SPECIFICATIONS W Penetrant Spray Station (not shown) also available. Contact Magnaflux for information on features and options. alf roller grille Power immersion grille Timers NOMINAL FILL LINE MECANICAL REQUIREMENTS PLUMBING Drain and fill connection, rear of tank OPTIONAL POWER IMMERSION GRILLE FILL/DRAIN L 4 SYSTEM 2436 4040 3448 3472 5472 OUTSIDE INSIDE INSIDE WIT POWER IMMERSION GRILLE GALLONS PER NOMINAL FILL L W X Y Z X A B INC (EIGT) (GALLONS) 36 24 36 33 21 26 Available Upon Request 3.0 60 40 40 42-1/2 36 36 36 36 32-1/2 31-1/2 5.6 170 48 34 36 43-1/4 29-1/4 30-3/4 43-1/4 25-3/4 25-1/4 5.5 140 72 34 36 67-1/4 29-1/4 30-3/4 67-1/4 25-3/4 25-1/4 8.5 220 72 54 36 67-1/4 29-1/4 30-3/4 67-1/4 45-3/4 25-1/4 14.3 370

REST STATION DRAIN STATION ROLLER GRILLES SPECIFICATIONS ROLLER GRILLE REST STATION Roller grilles support parts during rest or drain cycles and facilitate the movement of heavy or basketed parts. The stations provide a support area equal to the basic tank size. Roller grille units can be bolted to adjacent components, or optional support legs may be used. 90 grille units accommodate the turning or reversal of the work flow. alf-tank roller grilles fit on the modular tanks and provide for direct drainage of material within the tanks. These may be used instead of drain stations in some applications to save space and cost. (Note: Not available for 2436 or 4040 Models) Drain stations have stainless steel trays to facilitate recovery of Penetrant, Emulsifier, Rinse Water and Wet Developer. Corrosion resistant rollers - nominal 2" OD on 4" Centers Synthetic bearings Interchangeable rollers are easily installed or removed Note: Model 2436 includes a corrosion resistant rack instead of rollers Stainless steel drain pan SPECIFICATIONS ROLLER GRILLE DRAIN STATION STRAIGT ROLLER GRILLE REST STATION STRAIGT ROLLER GRILLE DRAIN STATION 90 TURN 90 TURN STRAIGT SECTION 90 SECTION SYSTEM L W F G 2436* 36 24 36 36 36 36 4040 40 40 2-1/2 40 50 2-1/2 3448 48 34 3 34 44 3 3472 72 34 3 34 44 3 5472 72 54 3 54 72 3 *Not as shown. Slightly different configuration. No rollers for 2436 Rest Station STRAIGT SECTION 90 SECTION SYSTEM L W F G 2436* 36 24 36 36 36 36 4040 40 40 8 40 50 7 3448 48 34 8 34 44 7 3472 72 34 8 34 44 7 5472 72 54 9 54 72 7-1/4 *Not as shown. Slightly different configuration. No rollers for 2436 Drain 5

TABLE TOP RINSE STATION (OPTIONAL) Used in place of the conventional rinse tank, the Table Top Rinse unit permits easy, manual access to hard-to-rinse parts and to parts with entrapment areas that must be turned and emptied after rinsing. Working at waist height reduces fatigue. Aroller grille provides an ideal work platform. The Table Top unit includes a hose and spray nozzle and a portable black light for surface inspection. The ydrowash power spray is a popular option. The Table Top unit includes a hose and spray nozzle and a portable black light for surface inspection. The ydrowash power spray is a popular option. The Table Top unit is enclosed at three sides and at the top. Asplit top unit, with curtained entry and exit, is available in the largest system to accommodate overhead conveyor installations. Stainless steel drain pan Structural steel frame and hose and held black light Easy access to hard-to-rinse parts and parts with entrapment areas Operator comfort TOP OF OPEN DOOR ydrowash spray gun Remover Injector Kit (Spray System) MECANICAL REQUIREMENTS SPLIT ROOF MODEL AS CURTAINED DOORS PLUMBING Water inlet connection, rear of tank Drain connection, rear of tank ELECTRICAL 115V, 60Z, 1P., 4 Amps (for black light) E L W SYSTEM 2436 4040 3448 3472 5472 SPLIT ROOF OUTSIDE INSIDE L W E X C D Available upon request 40 42 82-1/2 113 36 34-1/2 33-1/2 48 36 75 105-1/2 44 29 33-1/2 72 36 75 105-1/2 68 29 33-1/2 72 56 85 105-1/2 68 49-1/2 43-1/2 72 54 85 68 50 44-3/8 9

DRYER STATION All parts must be thoroughly dried during processing. If Dry Developer is used, parts are dried prior to the application of the developer. If Wet Developer is used, they are dried after the application of the developer. MAGNAFLUX dryers provide uniform heating and air circulation throughout the drying chamber, with air intake to regulate humidity for optimum drying. Proper air circulation aids in drying and eliminates hot spots which can degrade penetrant performance. Easy access and a large interior, along with a roller grille, accommodate high volume throughout. An easily read and calibrated digital thermostat maintains desired temperature levels. Adryer with solid top and balanced end doors provides virtually airtight heating. An optional dryer with a split top and flame resistant curtain doors accommodates overhead monorail conveyor systems. eavy gauge steel panels Insulated interior panels with heat reflective surfaces Easily removable fans and heater elements Adjustable, calibrated digital thermostat (N/A - on 2436) Air circulation fans Wire mesh beneath roller grille BENEFIT A controlled, consistent drying cycle Energy efficient MECANICAL REQUIREMENTS SPECIFICATIONS TOP OF OPEN DOOR ELECTRICAL AMPERAGE DRAW VARIES BY MODEL AND VOLTAGE SPECIFIED AMPERAGE MODEL AT 230V AT 460V 2436 32 16 4040 32 16 E SPLIT ROOF MODEL AS CURTAINED DOORS 3448 32 16 3472 32 16 5472 48 24 Other voltages can be accommodated. Check with your MAGNAFLUX representative. L W SYSTEM 2436* 4040 3448 3472 5472 OUTSIDE INSIDE L W E X C D 36 24 36 33 21 26 40 42 82-1/2 113 36 34-1/2 33-1/2 72 36 75 105-1/2 68 29 33-1/2 72 36 75 105-1/2 68 29 33-1/2 72 56 85 125-1/2 68 49 43-1/2 10 Split Roof 72 54 85 68 50 44-3/8 Top Loading, with corrosions resistant rack instead of rollers

INSPECTION STATION Sturdy inspection booths provide the darkened area and the black lights for thorough Fluorescent Penetrant Inspection. Ample room is provided for part handling, and roller grilles facilitate the movement of heavy or basketed parts. Asolid worktop may be specified in place of the roller grille. Flame resistant curtains extend below table height, assuring a properly darkened environment. An overhead fan provides ventilation. Asplit roof model is available in the largest system to accommodate overhead monorail conveyor systems. Roller grille (solid worktop available as option) Note: Model 2436 available with solid worktop only Ventilating fan White light Black lights Flame resistant curtain Operator switch panel Full length curtains (4" above floor) enclose work area Large enough to accommodate two or more inspectors Provides ideal environment for thorough part inspection Easy part entry/exit Comfortable work environment Unobstructed work area Meets ambient light restriction specification Solid worktop SPECIFICATIONS CURTAIN CURTAIN CURTAINS MECANICAL REQUIREMENTS ELECTRICAL 115V, 60Z, 1P., 10 Amps Other voltages can be accommodated. Check with your MAGNAFLUX representative. L B W SYSTEM 2436 4040 3448 3472 5472 OUTSIDE INSIDE L W B C D 36 36 83 24 36 36-3/4 40 40 88-3/4 30 40 36-3/4 72 34 88-3/4 30 34 31-1/4 72 34 88-3/4 30 34 31-3/4 72 54 88-3/4 36 54 43-1/4 SPLIT ROOF 72 54 88-3/4 36 54 43-1/4 11

DRY DEVELOPER STATIONS DYNAMIC CLOUD STATION The air in this flat bottom chamber is pre-dried and circulated at low velocity to sustain a continuous powder cloud in which the parts are placed. Powder application and evacuation cycle times are adjustable. This method involves a sealed, fully enclosed dry powder container to minimize waste due to caking. An optional Dust Collector is available to trap the airborne particles that are evacuated from the chamber prior to removal of parts. SWIRL CLOUD STATION The Swirl Cloud station is an air tight chamber with an air manifold and hand valve. Aburst of shop air disperses Dry Developer, gently settling it onto the surface of the part. Solid end doors provide entry and exit. ADust Collector, which requires no external ducting, is available as an option for particle evacuation. DEVELOPER DIP STATION The tank for the dipping process has baffled duct work for dust collector hookup. The developer acts to pull the penetrant remaining in a cavity to the surface where it is readily visible under black light. Wet or Dry Developers may be used. Wet Developer (suspended or dissolved in water) is applied by immersion of the part. (See Wet Developer station) Roller grille Enclosed chamber with vertically rising doors Air connection with regulator and gauge Filtered air inlet Dust collection duct eavy Gauge stainless steel tank *Roller Grille Even distribution of developer on part surfaces *2436 Top Loading has floor grating eavy gauge stainless steel tank Baffled duct work Even distribution of developer on parts surfaces Minimal developer caking Most efficient use of powder Dust collector Air line dryer (highly recommended) Dust collector Included with 2436 Dust collector alf Grille BENEFIT Low cost application TABLE TOP DEVELOPER STATION Used in place of the Developer Dip station, the Table Top Developer unit permits easy, manual application of Dry Developer. Asplit roof model is available to accommodate overhead monorail conveyor systems. Roller grille top Developer applicator hose Easy access to assure that unusually shaped parts and parts with entrapment areas are properly covered. Operator comfort Dust collector 12

POWER IMMERSION GRILLE Air powered Immersion Grilles facilitate the lowering and raising of large parts or large baskets of parts in and out of the various processing tanks. The Immersion Grille, with its durable, corrosion resistant rollers, raises and lowers permitting rapid part drainage. Some part capacity in the tank is sacrificed. DUST COLLECTORS Airborne particles are evacuated from Dry Developer stations prior to the removal of parts. This steel cabinet has positive seal doors and requires minimal floor space. SPECIFICATIONS SPECIFICATIONS TANK TANK 14 SYSTEM 2436 4040 3448 3472 5472 V OUTSIDE LIFT PLATFORM V S T Available Upon Request 107 8 35 96 6 41 96 6 65 96 6 65 32 25-1/4 25-1/4 45-1/4 Size 1 P 3 P 10 P L W L W Electrical 22-1/8 41-1/8 22-1/2 115V, 60Z, 1P 28-1/8 28-1/4 52-1/8 230 or 460 64 43-1/2 109 230 or 460