UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Similar documents
I/O ZONE 560/583 AND OPERATION MANUAL

KIT IOM

Greensource i Series SV Model Installation and Maintenance Manual

SM Field Installed Electric Heat Kit

HPC. Heat Pump Controller. Installation, Operation, and Maintenance Manual (2019/02)

LM CS Series Heat Pump

Model SV - i Series Geothermal Heat Pump

Greensource i Series BC Model Console Installation, Operation and Maintenance Manual

SM CS Series Heat pump

SM CS Series Heat pump

INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

WW/WT SERIES. Table of Contents

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Specifications and Performance

SV Condensing Section

Specifications and Performance

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

Installation and Maintenance Manual TA Series

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

Reinventing Energy Efficiency

BasicTroubleshooting Information and Guidelines

Bosch ZS Series Zone Sensors R1

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

ES Series. Installation and Maintenance Manual

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

I/O ZONE 560/583 USERS GUIDE

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Pioneer Gold Controller Technical Guide

GUIDE SPECIFICATIONS AQUARIUS ii

FOR SERVICE TECHNICIAN S USE ONLY

ENGINEERING SPECIFICATIONS

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

ENGINEERING SPECIFICATIONS

BACnet Points List for Single Compressor Water to Water PROSSWWE-01

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

BGH Series Hot Surface Ignition Control

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Heat pump SM024 SM036 SM048 SMO60 SM070. Installation and Maintenance Manual (2013/1)

Heat Pump Defrost Board Replacement Kit

50A Integrated Furnace Control

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Interrupted Ignition Series Oil Primary Control

Hoshizaki America, Inc.

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Air Conditioning Operation and Troubleshooting Matt Dunham

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Operator: Save these instructions for future use!

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Installation Instructions

PRODUCT SPECIFICATIONS

SERVICE MANUAL IMPORTANT IMPORTANT 4SCU20LX 4SHP20LX ALLIED AIR ENTERPRISES I. GENERAL. August Electrical

Intelligent cascading kit

INSTALLATION INSTRUCTIONS

50A Integrated Furnace Control

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

AP SERIES VOLTAGE DESIGNATION: 1-208/1/60 & 230/1/60 CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

MODULE-AIRE VERTICAL PACKAGE UNITS MB SERIES MB SERIES. Energy Wise HVAC Equipment

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

EC Large Series 072, 096, 120, 150, 151, 180, 181, 210, 240, 242, 300, 360. Installation, operation and Maintenance Manual T (01/15)

WaterFurnace FX10 Application Guide Reversible Chiller

Operator: Save these instructions for future use!

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Specifications and Performance

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OPERATING INSTRUCTIONS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX

Pioneer Gold Controller Technical Guide. Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal

MAC N-407 Air-Cooled Chiller

DXM2 Digital Heat Pump Controller

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Installation and Maintenance Manual OM

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

DXair Pool Dehumidifiers

R4H4. Product Specifications

Installation Instructions

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Hoshizaki America, Inc.

Hoshizaki America, Inc.

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

KM-61BAH KM-101BAH KM-151BAH

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Indoor Air Handlers with Compressors MVS and MVW

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

Transcription:

UPM I Unit Protection Module Installation and Operation Manual 6 720 220 321(2015/06)

2 Key to Symbols Contents Key To Symbols...2 Warnings...2 Specifications... 3 Unit Protection Module (UPM)....3 Power Random Start Up... 4 Anti Short Cycle Delay... 5 Y Call... 5 High and Low Pressure Protection... 5 High Pressure Protection... 5 Low Pressure Protection... 5 Ground... 5 DIP Switch Settings... 6 Intelligent Reset...6 Lockout Reset...6 Selectable Alarm Mode...6 Test Mode...6 Freeze Protection... 6 Brownout Protection... 7 Condensation Overflow... 7 IUPM Sequence of Operation Flow Chart... 8 Terminology...9 Notes... 10 KEY TO SYMBOLS Warnings Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of the warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. The following keywords are defined and can be used in this document: TICE Is used to address practices not related to personal injury. CAUTION Indicates a hazardous situation wich if not avoided, could result in minor to moderate injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Important Information This symbol indicates important information where there is no risk to property or people. Warnings WARNING: Installation and servicing of this equipment can be hazardous due to system pressure and electrical components. Only trained and qualified personnel should install, repair, or service the equipment. DANGER: Before performing service or maintenance operations on the system, turn off main power to the unit. Electrical shock could cause personal injury or death. CAUTION: When working on equipment, always observe precautions described in the literature, tags, and labels attached to the unit. Follow all safety codes. Wear safety glasses and work gloves. Use a quenching cloth for brazing, and place a fire extinguisher close to the work area. 6 720 220 321 (2015/06) Subject to change without prior notice

(2015/06) Specifications 3 SPECIFICATIONS Power: 24VAC ± 10%, 50-60Hz, 1.4 VA of standby power consumption (Single Class II 70VA or 100VA option available) Physical: Printed Circuit Board with plastic stand-offs. Environmental Operating Range: A range of -40 F to 176 F (-40 C to 80 C); 10% to 90% relative humidity, non-condensing. All controls are conformal coated for protection from environmental contaminates. Digital Outputs: Three (3) digital outputs - relay contacts rated at 10A resistive @ 125 VAC, reserved for: Compressor contactor: 24VAC when ON Alarm purposes dry contact (normally open dry contact)- Pulse or Constant. Unit Diagnostics Display (UDD) -Pulse only Inputs: Six (6) inputs - dedicated inputs for: High Pressure Control (HPC) Low Pressure Control (LPC) Water coil Freeze Sensor (FREEZE 1) 10K @ 77ºF Thermistor Air Coil Freeze Sensor (FREEZE 2) 10K@ 77ºF Thermistor. Condensate Overflow Sensor (CON) 230 kω.+/- 15% Compressor Call (Y) Signal Status Indication: Visual (LED) status of power and alarm status indication. Protection: Surge and transient protection circuitry. Weight: 0.14 lbs. (0.07 Kg). Overall Dimensions: 4-1/4 (width) by 3-3/4 (height) (recommended panel depth). 108mm (width) by 95mm (height) by 44mm (recommended panel depth). Mounting Hole Dimensions: Four mounting holes in rectangular pattern with dimensions between them as follows: 3-3/4 (width) by 3-1/4 (height). 95mm (width) by 83mm (height). Listed By: UL E118867 As a recognized component in USA and Canada. This manual is for UPM board P/N# 8733 809 536. UNIT PROTECTION MODULE (UPM) The Unit Protection Module (UPM) is a Printed Circuit Board Assembly (PCBA) that interfaces with the thermostat or the Digital Direct Controller (DDC). (Figure #1) The main purpose of this device is to protect the compressor by monitoring the different states of switches and sensors. This device provides time delays and protects against freezing of the unit water and refrigerant heat exchangers, as well as condensate overflow when the appropriate sensors are installed. The ALARM output is a Normally Open () dry contact. If 24 VAC output is needed, The R terminal must be wired to the ALR-COM terminal; 24 VAC will be available on the ALR-OUT terminal when the unit is in alarm condition. If pulse is selected the alarm output will be pulsed. The display output is dedicated for the unit diagnostic display only. Display output: The display output is a pulse output connected to the Unit Diagnostics Display (UDD) and it pulses 24VAC when the unit is in a lockout condition. 6 720 220 321 Revised 06-15

4 Unit Protection Module (UPM) 13 12 11 1 2 3 4 5 17 6 7 15 14 8 16 9 10 Figure # 1 UPM Single Stage [1] Board Power LED Indicator [16] Alarm Dry Contact [OUT & COM] [2] UPM Status LED Indicator [17] UPM Ground Standoff [3] Water Coil Freeze Protection Temperature Selection [R30] [4] Air Coil Freeze Protection Temperature Selection [R24] [5] DIP switch bank-for UPM Board Settings [6] Water Coil Freeze Connection [Freeze 1] [7] Air Coil Freeze Connection [Freeze 2] [8] LCD Unit Display Connection [Display] [9] 24VAC Power Input [R] [10] Compressor Contactor Output [CC] [11] High Pressure Switch Connection [HPC] [12] Call for Compressor [Y1] [13] Low Pressure Switch Connection [LPC] [14] 24VAC Power Common [C] [15] Condensate Overflow Sensor [COND] Power Random Start Up This feature prevents multiple units sharing the same electrical circuit or network from starting at the same time. It assures that Heat Pumps sharing the same electrical circuit do not demand high inrush currents simultaneously when restarting after a power failure. If the controller has been completely powered down for more than 28 milliseconds, a random delay is initiated; typically, if the controller is set to normal operation (test switch set to ) the unit will start between the time range of 270 and 300 seconds. In order for the random sequence to initiate, the unit power must be removed completely. 6 720 220 321 (2015/06) Subject to change without prior notice

(2015/06) High and Low Pressure Protection 5 If the UPM board is set to TEST mode through the TEST DIP switch (SW1), the Time Delay will be 10 seconds. Anti Short Cycle Delay This feature protects the compressor from shortcycling if the Y call is set and removed in quick succession. The anti short cycle (ASC) delay is a 300 second delay on break during normal operation. If the UPM board is set to test mode through the TEST DIP switch, the Anti Short Cycle Delay will be 5 seconds. Y Call The UPM will energize the compressor s output (CC) in the event of a Y call from a thermostat or controller (after the random start up and/or the anti short cycle delays have elapsed). The Y input terminal must be energized with a 24VAC signal. HIGH AND LOW PRESSURE PROTECTION The UPM monitors the state of the High and Low Pressure switch inputs, HPC and LPC respectively on the board. These switches must be closed in order for the controller to energize the compressor output (CC). The CC output will only be energized when the switches are closed and the anti short cycle (and/or random start up when applicable) has expired. High Pressure Protection If the HPC switch is open upon a Y call the UPM will not energize the CC output and therefore the compressor will remain off. The fault LED will flash one (1) time intermittently, indicating a High Pressure fault, and the alarm contact will remain open. If the compressor is running in normal mode on a Y call and the high pressure switch opens, the UPM will shut down the compressor output, and will keep it off until the switch closes and the antishort cycle has expired. The controller will keep track of the number of times the switch opens. If within a one (1) hour period the switch opens the number of times set via the DIP switch, the controller will shut the compressor down and enter a hard lockout condition; it is only under this condition that the alarm contact will be closed and energized. If the high pressure fault condition still exist, or occurs 2 to 4 times (depending on LOCKOUT DIP switch setting) within 60 minutes of the initial condition, the unit will enter a hard-lockout state and require a manual reset. Low Pressure Protection If the LPC switch is open upon a Y call the UPM will not energize the CC output and therefore the compressor will remain off. The fault LED will flash two (2) times intermittently, indicating a Low Pressure fault, and the alarm contact will remain open. If the compressor is running in normal mode on a Y call and the low pressure switch opens, the UPM will keep the compressor running for two (2) minutes. If the condition remains after this period of time the compressor will shut down and the UPM will enter a soft lockout. The UPM will flash two (2) times for the LPC, and the alarm contact will remain open. If the LPC switch closes, the UPM will start the compressor after the anti short cycle has expired and the UPM will energize the compressor output. If the low pressure fault condition still exists, or occurs 2 to 4 times (depending on LOCKOUT DIP switch setting) within 60 minutes of the initial condition, the unit will enter a hard-lockout state and require a manual reset. TICE: To exit a hard lockout condition, the controller must be reset from the Y or R terminal by removing the power from the selected terminal. The user can choose which will be the reset point via the RESET DIP switch. GROUND The UPM controller takes its ground reference from the unit chassis. This is connected via the controller s metal stand off located in the lower left corner. (See Figure #1) 6 720 220 321 Revised 06-15

6 DIP Switch Settings DIP SWITCH SETTINGS The DIP switches are used to configure most of the available features of the UPM as follows: Lockout mode: two (2) or four (4) strikes Reset mode: Y signal or R signal Alarm mode: Constant or Pulse Test mode: Normal or Test operation The settings shown in Figure #2 are factory default for most heat pump applications. However, the unit wiring diagram is the ultimate guide for factory DIP switch default settings. ON 1 2 3 4 LOCKOUT RESET ALARM TEST Figure # 2 -DIP Switch Settings Table #1 shows the available options on the UPM board DIP switch banks and it depicts the switch position and its associated functionality. Table 1: UPM DIP Switch Configuration 4 LOCKOUT 4 2 3 RESET R Y 2 ALARM CONT PULSE 1 TEST Intelligent Reset If a fault condition is initiated, the 5 minute delay on break time period is initiated and the unit will restart after these delays expire. During this period the fault LED will indicate the cause of the fault. If the fault condition still exists or occurs 2 or 4 times (depending on 2 or 4 setting for Lockout dip switch) before 60 minutes, the unit will go into a hard lockout and requires a manual lockout reset. A single condensate overflow fault will cause the unit to go into a hard lockout immediately, and will require a manual lockout reset. Lockout Reset A hard lockout can be reset by turning the unit thermostat off and then back on when the RESET dip switch is set to Y or by shutting off unit power at the circuit breaker when the RESET dip switch is set to R. Selectable Alarm Mode The UPM controller can be configured to have either a constant or pulse signal. If constant (CONT) is selected the UPM will provide a closed contact at the alarm output until the alarm is cleared. If pulsed (PULSE) is selected the UPM will sequence the alarm contact with the fault LED flashes. Test Mode (TEST) In test mode the ASC and Random Start time delays are reduced (5 seconds and 10 seconds respectively), and serves no function to the enduser equipment. The alarm and display relays also pulse for both soft and hard lockout conditions, and are both cleared through a manual reset. FREEZE PROTECTION The water side freeze protection sensor, mounted close to condensing water coils (see Figure#3) monitors refrigerant temperature between condensing water coil and thermal expansion valve (TXV). If temperature drops below or remains at freeze limit trip for 30 seconds, the controller will shut down the compressor and enter into a soft lockout condition. The default freeze limit is 26 F, however this can be changed to 15 F by cutting the R30 or freeze 1 resistor located on top of DIP switch bank as shown in Figure# 1. Evaporator freeze protection sensor mounted after the thermal expansion device and the evaporator, (see figure #4) monitors refrigerant temperature between the evaporator coil and thermal expansion valve. If temperature drops below or remains at freeze limit trip for 30 seconds the controller will shut down the compressor and enter into a soft lockout condition. The default freeze limit trip is 26 F If temperature drops below or remains at the freeze limit trip for 30 seconds, the controller will shut the compressor down and enter into a soft lockout condition. Both the status LED and the Alarm contact will be active. The LED will flash three (3) times the code associated with this alarm condition. If the freeze stat fault condition still exist, or occurs 2 to 4 times (depending on LOCKOUT DIP 6 720 220 321 (2015/06) Subject to change without prior notice

(2015/06) Brownout Protection 7 switch setting) within 60 minutes of the initial condition, the unit will enter a hard-lockout state and require a manual reset. CONDENSATION OVERFLOW The UPM controller continuously monitors the drain pan for high condensate water level. It utilizes a sensor (See Figure #5) to identify an alarm condition when the sensor s impedance drops below 230KΩ +/- 15% (Only when condensate sensor option is present). Once the UPM senses this resistance value it enters into a hard lockout and reports the corresponding code via its status LED; four (4) flashes. Figure # 3 - Freeze Sensor Location To exit the hard lockout condition water has to return to its normal level in the drain pan and the UPM has to be reset by removing power from the Y terminal (or if set accordingly on the DIP switch). The compressor will be turned on after the anti short cycle expires. The condensate overflow is the only system safety (of the 6 safeties) that enters directly into a hardlockout upon an initial fault condition. There is no soft-lockout state for the condensate overflow fault. Figure # 4 BROWUT PROTECTION The UPM controller will constantly monitor the power supply; if the nominal voltage drops below 25% of its value, (18 VAC approximately), the unit will enter brownout protection mode. The compressor CC output will be de-energized and the unit will enter the soft lockout mode. The controller will not monitor the power supply during the first 500 milliseconds of compressor start up to avoid nuisance and false alarms. Once the UPM detects a brownout condition, the fault LED will flash five (5) times intermittently, as error code indication. If the brownout fault condition still exist, or occurs 2 to 4 times (depending on LOCKOUT DIP switch setting) within 60 minutes of the initial condition, the unit will enter a hard-lockout state and require a manual reset. Figure # 5 - Condensate Overflow Sensor Location 6 720 220 321 Revised 06-15

8 UPM Sequence of operation flow chart UPM SEQUENCE OF OPERATION FLOW CHART START Y1 = ON RESET ON Y RESET ON R R = 24VAC POWER/ SWITCHES/SENSOR STATUS CHECK CLEAR FAULTS V > 18VAC BLINK CODE ON STATUS LED SOFT LOCKOUT RECORD ALARM START COUNTER (IF APPLICABLE) COUNTER NEEDED? CNT = CNT+1 HPC = CLOSED LPC =CLOSED CC OUPUT= ON LOCKOUT CAN BE SET TO 4 VIA DIP SWITCH COUNT = 2 OR COUNT = 4 START TIMER TIME > 120 SEC BLINK CODE ON STATUS LED HARD LOCKOUT? FRZ >TEMP LIMIT START TIMER TIME > 30 SEC BLINK CODE ON STATUS LED DISPLAY OUTPUT = PULSE ALR OUTPUT = ON/PULSE CON > 0 CC OUTPUT = OFF START ANTI SHORT CYCLE INITIAL POWER UP START RANDOM START UP T > ASC OR CC RS SEC CC OUTPUT = ON 6 720 220 321 (2015/06) Subject to change without prior notice

(2015/06) Terminology 9 TERMILOGY PSC - Permanent-split capacitor motor EER - Energy Efficiency Ratio COP - Coefficient of Performance. The COP provides a measure of performance for heat pumps that is analogous to thermal efficiency for power cycles. ECM-Electronically Commutated Motor. UPM-Unit Protection Module WLHP - Water Loop Heat Pump GLHP - Ground Loop Heat Pump RLA - Running Load Amps Decommissioning- Means the final shut-down and removal from operation or usage of a product or piece of equipment containing fluorinated greenhouse gases; Repair- Means the restoration of damaged or leaking products or equipment that contain, or whose functioning relies upon, fluorinated greenhouse gases, involving a part containing or designed to contain such gases; Conditioned space-space within a building provided with heated or cooled air, or both (or surfaces); and, where required, with humidification or dehumidification means, to maintain conditions for an acceptable thermal environment. LRA - Locked Rotor Amps FLA - Full Load Amps NPA - Name Plate Amps HP Heat Pump Suction Pressure - Pressure entering compressor Discharge Pressure - Pressure leaving compressor (R/A) - Return Air Recovery - Means the collection and storage of fluorinated greenhouse gases from products, including containers, and equipment during maintenance or servicing or prior to the disposal of the products or equipment; Recycling- Means the reuse of a recovered fluorinated greenhouse gas following a basic cleaning process; Reclamation-Means the reprocessing of a recovered fluorinated greenhouse gas in order to match the equivalent performance of a virgin substance, taking into account its intended use; 6 720 220 321 Revised 06-15

10 Notes TES 6 720 220 321 (2015/06) Subject to change without prior notice

(2015/06) Notes 11 6 720 220 321 Revised 06-15

Revised 06-15