INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

INSTALLATION INSTRUCTIONS

INSTALLATION FOR THERMOSTATIC VALVES

INSTALLTION FOR THERMOSTATIC VALVES

MINIATURE THERMOSTATIC VALVE

CORALAIS BODYSPA BATH AND SHOWER FAUCET

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4010B 4011B

TIMES SQUARE TWO-HANDLE THERMOSTAT

Installation Instructions

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

ARIN THERMOSTATIC SHOWER SYSTEM

Installation Instructions / Warranty

TUB AND SHOWER FAUCET

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Series # 17 3-Hole Widespread Faucet with Push Drain

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

Installation Instructions

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Installation Instructions

Installation Guide ASME A ANSI A117.1 CUPC / IAPMO LISTED / ADA COMPLIANT. Engineering Excellence

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

SuperKlean Washdown Products

Installation S

569, 570, 571, 572 Series

Thermostatic Valve and Trim

Enzo Concealed Shower Mixing Valve

Leilani ShowerSpa Model #1022-B Owner's Manual

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Installation S

Installation S

Installation S

Installation S

569, 570, 571, 572 Series

Oahu Showerspa Model #1035 Owner's Manual

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

PL-004-SS. * Proper water pressure is required for simultaneous operations

CB-4070 BLACK ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

M INSTALLATION INSTRUCTIONS M FLEETWOOD SINGLE CROSS HANDLE PRESSURE BALANCE TRIM ONLY, TO SUIT M ROUGH

Inta City Concealed Shower Mixing Valve CT80010CP

Installation Manual PS-225 & PS-275

INSTALLATION. Glass Panel Doors (select models) CAUTION

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

s y ens Av Avensys FIN EST RUS SLO RUS UAE

SANTA CRUZ. Santa Cruz ShowerSpa Model #1033 Owner's Manual

INSTALLATION INSTRUCTIONS M SHOWER SLIDING RAIL

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

Sign Planogram: Plumbing Repair Bay Name: Plumbing Repair 4.1. Toilet Repair. 72" from floor to bottom of AV. Replacing a Fill Valve

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

Thermostatic Deck-Mounted Bathtub Mixer Installation Guide

Installation Manual PS-200 & PS-201

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Butler Mill and Brassworks Ltd. Exposed 1/2 Thermostatic Valve Installation Instructions

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Package Content. Decor Star 1 2. PL-011-GS Rev. A

INSTALLATION INSTRUCTIONS

Undercounter Refrigeration

A301 SHOWER PANEL INSTALLATION GUIDE

Mio Concealed Shower Mixing Valve MI40010CP

Installation. Leveling

INSTALLATION INSTRUCTIONS

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

Thermostatic mixing valves with interchangeable cartridges

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

TECHNICAL DATA. Wet 26a. February 22, 2009

CAST IRON PEDESTAL TUB

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Thermostatic Concealed Shower Valve

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Parts & Material Included

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION INSTRUCTIONS

Thermostatic Shower Valves Installation Guide

TUB AND SHOWER FAUCET

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

CAST IRON CLAWFOOT TUB

Avensys Avensys FIN EST SLO RUS UAE

ACRYLIC CLAWFOOT TUB

I mpo rta n t : Please re g is t e r y ou r p rod uct onli ne at www. santecfaucet. com wi thi n 30 da ys o f pu rc h as e. S an t e c reser v e s

1/7 SPOUT INSTALLATION

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

INSTALLATION INSTRUCTIONS

SAN RAPHAEL GRANDE ORDERING INFORMATION NOTES T01-B INSTALLATION INSTRUCTIOINS 4.8L SKIRTED CLASS FIVE ONE-PIECE TOILET 4.

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

! WARNING. Before using product, read and understand instructions.

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Transcription:

INSTALLATION INSTRUCTIONS MODEL: BISTRO THERMO SHOWER KIT (RH-5344) 1

Restoration Hardware Thermo Shower Kit Specification Diagram 2 All Threaded Connections are 3/4 NPT Dimensions are in Inches and Approximation of a Typical Installation

Common tools needed: 1. General Characteristics In case of instantaneous heaters, hot water flow has to at least meet flow required by heater and maintain burning. (Specified by heater manufacturer) Operating Specifications Hot water supply temperature: Maximum: Reference manufacturing specification Minimum: 140 F Minimum difference between hot and mixed temperature is: 50 F Operating Pressure: Maximum: 70 PSI Minimum: 20 PSI Operating pressure (on hot and cold line) should be kept as balanced as possible in order to assure maximum efficiency. When the pressure is greater than 70 PSI, a pressure reducer is required and must be fitted before valve. Technical Data The temperature control knob is graduated from 75 F to 120 F with auto stop at 100 to avoid scalding. Temperature limit setting of less than 120 F. Fit a stop valve/volume control between thermo valve outlet and end device(s). Plumbing Recommendations An independent water supply for both hot and cold is required. Do not pipe off ring main. Large runs of pipe work will cause frictional loss of pressure. The recommended main water supply piping to valve shall be 3/4 minimum. If more than one valve is installed, the recommended main water supply piping to valve shall be 1 minimum, reducing to 3/4 within 24 of each valve. (Ensure adequate supply from both hot and cold water can be maintained.) Water By-Laws The mixing valve should be installed in compliance with the water by-laws. For further details refer to the latest copy of bylaws guide or your local water authority. Rough in Valve Installation Note: Use Teflon tape or equivalent to seal all threaded port joints. Do not remove mud cover from valve before locating mounting surface depth in the wall. Do not turn the cartridge stem - temperature settings are pre-calibrated at the factory. Install plug into one of the two outlet ports. Note: For proper valve operation only one outlet port may be used. Mount valve to cross support using shims and screws (not included). Valve shall be perpendicular and fixed firmly to cross support to achieve proper trim attachment. Place the cross support with valve between wall studs. The min./max. valve exposure template on the mud cover and vertical height desired within tub/shower enclosure determines the exact cross support placement. Attach cross support to wall studs. Figure 1 Cartridge stem DO NOT TURN Shim Wall stud Figure 2 Cross support Maximum exposure Plug Finished wall Mud cover template Minimum exposure Mud cover 3

2. Connecting Water Supply Thoroughly flush supply lines to remove any debris, metallic shavings, flux, etc. Shut off water supply to valve. Hot and cold water supplies MUST be connected to designated sides for proper operation of valve. If solder/brazing the fitting connections, pre-assembly hot & cold adapter fittings to copper piping. Using Teflon tape or equivalent to attach adapter to appropriate inlet port. Important: All excessive heat shall be a minimum of 4 from valve. Connect outlet pipe to stop valve/volume control (not included), and from stop valve pipe to various end device(s). Turn on water supply to valve and check for leaks. Outlet pipe for shower connection 4 min. Hot water supply Cartridge stem (DO NOT TURN) Figure 3 Cold water supply 4

3. Installing Trim & Temperature Setting Remove and discard mud cover and screws. Slide sleeve over valve body with grooved notch to topside. Slide cover plate with gasket over sleeve and attach with decorative screws provided (see Figure 4). Orient and position limit stop as shown in Figure 5. Slide Nomenclature ring over sleeve, aligning 100 to notch in sleeve. Open shut-off valve and verify water temperature at outlet device by using a thermometer. NOTE: The safe and factory set temperature is 100 F. The next step refers to adjustment of the temperature, otherwise skip to the following step. Rotate cartridge stem to adjust temperature: (clockwise = colder or counterclockwise = hotter) Place bonnet onto cartridge stem with red button (100 F) positioned straight up and inline with notch on the sleeve (see Figure 6). Place decorative handle onto bonnet and secure with screw. Remove adhesive tab from cap and press onto top of handle. Sleeve Valve Coverplate Figure 4 Stop ring Bonnet Nomenclature ring Cartridge stem Handle Cap Figure 5 Figure 6 5

4. Maintenance and Troubleshooting The thermostatic valve has various screens that filter debris and unwanted particles that may damage the valves' cartridge and operation. Through years of use, these screens may build up with impurities and limescale, restricting the flow of water through the cartridge and or check valves. The following steps describe removal and cleaning procedure. Cartridge (Reference Figure 7) Carefully remove the handle, bonnet, stop ring, cover plate and sleeve. Shut off the water to cartridge by tightening center screw on each check valve, 7 turns maximum. Unscrew the cartridge using 1-3/16 or adjustable wrench; gently remove cartridge from housing. Clean the screens by rinsing the cartridge under running water. If necessary, soak in a 50/50 mix of white vinegar and water to remove limescale. Wipe cartridge and housing with wet cloth and apply a thin film of non-petroleum grease to o-rings. Do not use Vaseline. Carefully install cartridge into housing and tighten to 10 ft-lbs. Fully open check valves and inspect for leaks. Check operation and flow. If improved, proceed to step 9, otherwise see checkvalve section below. Reinstall trim and set temperature per section 3. Cartridge Sleeve Stop ring Bonnet Check valve O-rings Screens Coverplate Handle Figure 7 6

5. Check valve (Reference Figure 8) Turn water supply to valve inlets off. Tighten center screw on check valve inward until it clears bottom on check valve slot. Unscrew check valve with large bladed screwdriver. Remove check valve and clean per step 4 and 5 above. Replace valve back into housing, unscrew center and re-close to 7 turns max. Turn on water supply to valve inlets. Fully open the check valve screws and inspect for leaks. Reinstall trim and set temperature per section 3. Check valve O-ring Filter Figure 8 7

Care and Cleaning The lustrous finish on your Restoration Hardware Bathware fixture should be treated with care. Improper handling or cleaning can damage the surface of any metal finish. Use a soft cloth to wipe clean. Avoid harsh abrasive cleaners. Water contains lime and other mineral deposits that will be left on the surface after the water has evaporated. You can prevent these deposits from forming by always wiping the fixture dry immediately after use. Technical Support and Customer Service For technical support in the installation of your Restoration Hardware Bathware fixture, please call 1-866-417-5207 weekdays between the hours of 7:00am and 4:00pm PST. For other questions regarding your order, to order additional components of the Restoration Hardware Bathware Collection, to order replacement parts, or to address warranty issues, please contact Restoration Hardware Customer Service at 1-877-747-4671. 8

Thermostatic s h o w e r s y s t e m s Thermostatic Shower Valve & Trim f e at u r e s & b e n e f i t s Solid brass components. Sixteen gallons/minute flow rate supports up to three water outlets running simultaneously. Temperature control only. Installation of thermostatic valve also requires the purchase and installation of flow control valve(s) sold separately. One flow control valve is needed for each water outlet in your shower system. (Showerhead, handheld shower, etc). User accessible, adjustable maximum water temperature selection. 3/4" Thermostatic Rough-in Valve, includes trim to match collection. Paraffin cartridge, Built-in check valves with service stops, NPT threading Meets ASSE Standard 1016, IAPMO and CSA Listed. Other Components (sold separately): Flow control valve & trim set. - On/off valve that controls water flow. - One valve needed per water outlet, allows for more than one outlet at a time. Valve trim extension kit. Extends valve an additional 1-3/8" from wall. Includes spine extension, lock washer and handle screw. Shower Only parts required Thermostatic valve & trim set Flow control valve & trim set Showerhead, flange & arm Shower with Handheld Shower parts required Thermostatic valve & trim set Flow control valve & trim set (2) Showerhead, flange & arm Handheld shower