XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Similar documents
XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

XVUC29 Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC

5.0. Photoelectric Sensors. Technical Reference. Introduction

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

UNIVERSAL COMPACT SENSORS

Plug-in Base, Long Range Sensor E3B2

Class 1 laser beam sensor safe for your eyes

Retro-reflective Sensing range: 0mm to 2000mm

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

S15 SERIES. Ceramics. Beverage & Bottling

Retroreflective sensor with polarization filter

M7100 Pressure Transducer

Laser Collimated Beam Sensor

Retroreflective sensor with polarization filter

OG-Cube Photoelectric Sensors Optical sensing technology

Overload relays. General descriptions. Configuration of the front

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Technical Data. Dimensions

Datasheet: K-22 LO Sensor

Fan speed controller Type Saginomiya XGE

E3M-V. Mark Sensor. Applications

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Installation Guide. Ceiling PIR Detector (311) Features and Connections

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

M5200 Industrial Pressure Transducer

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

02/11/2015

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Temperature measurement with current output and PNP/NPN transistor switching output output 2 reprogrammable as switching output TS-400-LI2UPN8X-H1141

Gas cylinder scale Model GCS-1

Ultrasonic Proximity Sensor

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Datasheet - MZM 100 ST2-1P2PWREM-A

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Datasheet - MZM 100 ST-SD2PREM-A

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

BOS 23K. Photoelectric Sensors BOS 23K

Vacuum suction nozzle OVEM-...-1P/1N

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Oxygen (O2) Single-Point Gas Detection System

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Lamp Supply (Recommended)

Datasheet - MZM 100 B ST2-SD2PREM-A

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

SPACEMOTION SERIES SMM 01

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

PHOTOELECTRIC AMPLIFIER SERIES

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Ultrasonic Proximity Sensor

U5300 Industrial Pressure Transducer

PolyGard 2-channel Gas Controller MGC-03

Technical Data. Dimensions

02/11/2015

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Background suppression photo sensors

D5100 Industrial Differential Pressure Transducer

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

Honeywell Durafit LED Retrofit Kit

General Specifications

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

D5100 Industrial Differential Pressure Transducer

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE

SOCH AUTOMATION AND POWER SOLUTION

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Snifter ATEX22 VERSION. User Manual. Distributor

Technical Data. Dimensions

2 General Application Photoelectric Sensors

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Snifter. User Manual. Distributor

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

2 General Application Photoelectric Sensors

Ultrasonic Reflective Sensor

Danfoss gas detection units

Multi-Gas-Controller MGC2

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

RTO. User guide 05/

Transcription:

Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated supply voltage Switching capacity in ma Switching frequency Voltage drop Current consumption Delay first up Delay response Delay recovery Setting-up Depth Height Width Product weight Main Range of product Series name Electronic sensor type Sensor name OsiSense XU General purpose multimode Photo-electric sensor XUX Sensor design Compact 92 x 71 Detection system Material Type of output signal Supply circuit type Wiring technique Discrete output function Electrical connection Product specific application Emission [Sn] nominal sensing distance PBT PMMA Multimode Plastic Discrete DC 3-wire 1 NO or 1 NC programmable 15 m polarised reflex 3 m diffuse 60 m thru beam 1.3 m diffuse with background suppression Solid state 1 male connector M12, 4 pins - Infrared diffuse Infrared diffuse with background suppression Infrared thru beam Red polarised reflex 11 m polarised reflex need reflector XUZC50 40 m thru beam need a transmitter T 2 m diffuse 1.3 m diffuse with background suppression With alarm output, <= 100 ma with overload and short-circuit protection 1 LED (green) for supply 1 LED (red) for instability 1 LED (yellow) for output state 12...24 V DC with reverse polarity protection <= 100 ma (overload and short-circuit protection) <= 250 Hz <= 1.5 V (closed state) <= 35 ma (no-load) < 200 ms < 2 ms < 2 ms Self-teaching 77 mm 92 mm 31 mm 0.2 kg The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jun 23, 2017 1

Environment Product certifications CE CSA UL Ambient air temperature for operation -25...55 C Ambient air temperature for storage -40...70 C Vibration resistance 7 gn, amplitude = +/- 1.5 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 30 gn (duration = 11 ms) conforming to IEC 60068-2-27 IP degree of protection IP65 double insulation conforming to IEC 60529 IP67 double insulation conforming to IEC 60529 Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Green Premium product Compliant - since 0914 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold 2

Dimensions Drawings Dimensions (1) Elongated hole Ø 5.5 x 7 (2) Elongated hole Ø 5.5 x 9 (3) Ø 5.5 hole 3

Mounting and Clearance Mounting and Clearance Possible Orientation of Elbowed Connector (Rear View) 4

Connections and Schema Wiring Schemes M12 Connector PNP/NPN DC M12 Terminals 1 1 + 3 2-4 3 Output 2 4 Alarm inactive 5

Performance Curves Detection Curves With Thru-beam Accessory (Thru-beam) Without Accessory (Diffuse) 1 : White 90% 2 : Grey 18% Object 10 x 10 cm Without Accessory (Diffuse with background suppression) 1 : White 90% 2 : Grey 18% Object 10 x 10 cm With reflector (Polarised reflex) With reflector XUZC50 6

Variation of Usable Sensing Distance Su (Without accessory, with adjustable background suppression) Teach Mode at Minimum Teach Mode at Maximum A-B : Object reflection coefficient (1) Black 6% (2) Grey 18% (3) White 90% (4) Sensing range (5) Non sensing zone (matt surfaces) 7