Brochure AP-MCK-13 Ceiling Mounted Cassette Unit Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquayup.com. 2013 McQuay International www.mcquayup.com A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.
Ceiling Cassette C series 4 Way Air Discharge And Air Swing It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room. Auto Mode Auto Mode allows the setting to change automatically between cool and heat mode depending on the room temperature and the set temperature required. Stylish And Slim Panel The slim panel can be blended easily into interior decoration and design. Hot Keep Cycle During heat mode hot keep cycle, the fan will run at low speed during the thermostat cycle off. As a result, one will not feel the draft of cold air discharge from the unit. Option of fan stop or fan run at specific interval timing can also be selected. Self Diagnosis This intelligent feature helps to detect any faults or malfunctioning in the system and give user a warning by blinking of the LED lights. Choices Of Netware III Wired And Wireless Controller GS01 SLM 8 Wired Controller (Field Installed Optional Accessories) NIM-Able The MCK-C series is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a systems of multiple indoor units in a building. * Refer local representative for details. M(5)CK 010/015/020 C/CR Cooling: 9500 Btu/h - 19000 Btu/h 2.78 kw - 5.57 kw Heating: 9500 Btu/h - 19500 Btu/h 2.78 kw - 5.72 kw M(5)LC 010/015 C/CR M(5)LC 018/020 C/CR Built-In High Head Drain Pump The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level. 700mm Compact Design The Ceiling Cassette C series is designed to be compact. Its body dimension is only 570mm X 570mm which can easily fit into a 600mm ceiling grids. This make installation a lot easier. Ceiling panel T bar 600 mm
Ceiling Cassette E series Modern And Elegant Panel It is designed with unique round side contour and new LED light location. Rotateable intake grill promote uniform installation. Allow 90 Rotation Superior Sound Level The MCK-E series is equipped with a newly-developed turbo fan; the shape produce low air turbulence. Model M(5)CK 020E/ER M(5)CK 025E/ER M(5)CK 028E/ER M(5)CK 040E/ER M(5)CK 050E/ER Max (dba) 34 37 42 47 49 Min (dba) 28 32 33 36 39 With up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 28dBA. Multi-Comfort - 3 Air Swing Pattern Control To increase the comfort level of the air conditioned area of MCK-E series, the system had been built in with 3 different type of air flow pattern to suit different requirement. M(5)CK 020/025/028/ 040/050 E/ER Cooling: 18300 Btu/h 49500 Btu/h 5.3 kw 14.5 kw PATTERN 1 Standard Setting For gentle drafts. 50 Draft Prevention Setting Select this setting to eliminate direct drafts which can lead to discomfort. PATTERN 2 The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control. 50 55 Setting to Prevent Soiling of Ceiling Recommended for location with light colour ceiling that must be kept potless. PATTERN 3 55 Heating: 17700 Btu/h 50000 Btu/h 5.1 kw 14.7 kw Lower Height Model The MCK-E series height is as low as 300mm to ease installation. Dimension (mm) Model A B M(5)CK 020 ~ 028E/ER 265 300 M(5)CK 040 ~ 050E/ER 300 335 A B Optimum Air Discharge Combining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional of the automatic air swing help further to evenly distribute conditioned air to every corner of the instrall area. Built-In High Head Drain Pump The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level. 700mm
Specifications CEILING CASSETTE MCK-C SERIES - R22 COOLING ONLY CEILING CASSETTE M5CK-C SERIES - R410A COOLING ONLY MCK 010C MCK 015C MCK 020C MCK 020C M5CK 010C M5CK 015C M5CK 020C M5CK 020C MLC 010C MLC 015C MLC 018C MLC 020C M5LC 010C M5LC 015C M5LC 020C M5LC 020C Btu/h 9500 12500 18000 19000 W 2780 3663 5280 5570 Btu/hr 9500 12500 17500 18000 W 2780 3660 5129 5280 W/W 3.03 3.04 2.87 3.04 W/W 3.09 2.82 3.03 3.06 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 46 49 52 51 Sound Pressure Level dba 46 49 52 52 Net Weight kg 28 28 43 47 Net Weight kg 28 30 47 47 Pipe Connection -Gas mm 9.52 12.70 15.88 15.88 Pipe Connection -Gas mm 9.52 12.70 12.70 12.70 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. CEILING CASSETTE MCK-CR SERIES - R22 HEATPUMP MCK 010CR MCK 015CR MCK 020CR MCK 020CR MLC 010CR MLC 015CR MLC 018CR MLC 020CR Btu/h 9500 12500 18000 19000 W 2780 3660 5280 5570 Btu/h 9500 12500 18400 19500 W 2780 3660 5390 5720 W/W 3.03 3.04 2.87 3.04 W/W 3.40 3.47 3.21 3.21 Sound Pressure Level dba 46 49 51 51 Net Weight kg 30 30 43 47 Pipe Connection -Gas mm 9.52 12.70 15.88 15.88 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. CEILING CASSETTE M5CK-CR SERIES - R410A HEATPUMP M5CK 010CR M5CK 015CR M5CK 020CR M5CK 020CR M5LC 010CR M5LC 015CR M5LC 020CR M5LC 020CR Btu/hr 9500 12500 17500 18000 W 2780 3660 5129 5280 Btu/hr 9500 11500 17500 18500 W 2780 3370 5129 5420 W/W 3.09 2.82 3.03 3.06 W/W 3.35 3.30 3.00 3.63 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 46 49 52 52 Net Weight kg 28 30 47 47 Pipe Connection -Gas mm 9.52 12.70 12.70 12.70 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD.
Specifications CEILING CASSETTE MCK-E SERIES - R22 COOLING ONLY MCK 020E MCK 025E MCK 028E MCK 040E MLC 020C MLC 025C MLC 028C MLC 35D Btu/h 19500 25000 27000 35000 W 5715 7327 7913 10258 W/W 2.92 2.88 2.91 3.41 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Sound Pressure Level dba 51 52 58 58 CEILING CASSETTE MCK-ER SERIES - R22 HEATPUMP MCK 020ER MCK 025ER MCK 028ER MCK 040ER MLC 020CR MLC 025CR MLC 028CR MLC 35DR Btu/h 19500 25000 27000 35000 W 5715 7327 7913 10258 Btu/h 19500 25000 28000 35000 W 5715 7327 8206 10258 W/W 2.92 2.88 2.91 3.41 W/W 3.38 3.17 3.49 3.73 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Net Weight kg 47 57 57 95 Pipe Connection -Liquid mm 6.35 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 19.05 Sound Pressure Level dba 51 52 58 58 Net Weight kg 47 57 57 95 Pipe Connection -Liquid mm 6.35 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 19.05 MCK 040E MCK 040E MCK 050E MLC 40D MLC 40D MLC 50D Btu/h 39000 39500 49500 W 11430 11600 14500 W/W 3.31 3.17 3.15 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] Width [with Panel] mm 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 MCK 040ER MCK 040ER MCK 050ER MLC 40DR MLC 40DR MLC 50DR Btu/h 39500 39500 48000 W 11600 11600 14100 Btu/h 42000 42000 50000 W 12300 12300 14700 W/W 3.22 3.31 2.93 W/W 3.79 3.85 3.49 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] Width [with Panel] mm 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 Height mm 852 852 852 Width mm 1030 1030 1030 Depth mm 400 400 400 Net Weight kg 100 100 105 Pipe Connection -Liquid mm 9.52 9.52 9.52 Pipe Connection -Gas mm 19.05 19.05 19.05 Sound Pressure Level dba 58 58 58 Height mm 852 852 852 Width mm 1030 1030 1030 Depth mm 400 400 400 Net Weight kg 100 100 105 Pipe Connection -Liquid mm 9.52 9.52 9.52 Pipe Connection -Gas mm 19.05 19.05 19.05 4) I) FOR MCK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. 4) I) FOR MCK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.
Specifications CEILING CASSETTE M5CK-E SERIES - R410A COOLING ONLY M5CK 020E M5CK 025E M5CK 028E M5CK 040E M5LC 020C M5LC 025C M5LC 028C M5LC 35D Btu/hr 18300 22200 27000 29200 W 5363 6506 7913 8558 W/W 3.08 3.36 2.84 3.03 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Sound Pressure Level dba 52 52 58 58 Net Weight kg 47 50 57 86 Pipe Connection -Liquid mm 6.35 6.35 9.52 9.52 Pipe Connection -Gas mm 12.70 15.88 15.88 15.88 CEILING CASSETTE M5CK-ER SERIES - R410A HEATPUMP M5CK 020ER M5CK 025ER M5CK 028ER M5CK 040ER M5LC 020CR M5LC 025CR M5LC 028CR M5LC 35DR Btu/hr 18300 22200 27000 29200 W 5363 6506 7913 8558 Btu/hr 17700 20500 28000 31800 W 5188 6008 8206 9320 W/W 3.08 3.36 2.84 3.03 W/W 3.48 3.41 3.53 3.66 Net Weight [with Panel] kg 26 [30] 28 [32] 31[35] 39 [43] Sound Pressure Level dba 52 52 58 58 Net Weight kg 47 50 57 86 Pipe Connection -Liquid mm 6.35 6.35 9.52 9.52 Pipe Connection -Gas mm 12.70 15.88 15.88 15.88 M5CK 040E M5CK 040E M5CK 040E M5CK 050E M5LC 35D M5LC 40D M5LC 40D M5LC 50D Btu/hr 31000 39000 39000 45000 W 9086 11430 11430 13190 W/W 3.28 2.92 2.98 2.93 Air Flow CFM 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] 300 [375] Net Weight [with Panel] kg 39 [43] 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 60 M5CK 040ER M5CK 040ER M5CK 040ER M5CK 050ER M5LC 35DR M5LC 40DR M5LC 40DR M5LC 50DR Btu/hr 31000 39000 39000 45000 W 9086 11430 11430 13190 Btu/hr 33400 39000 39500 48000 W 9789 11430 11577 14070 W/W 3.28 2.92 2.98 2.93 W/W 3.84 3.06 3.21 3.43 Air Flow CFM 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] 300 [375] Net Weight [with Panel] kg 39 [43] 39 [43] 39 [43] 41[45] Power Supply V/Ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Height mm 852 852 852 852 Sound Pressure Level dba 58 58 58 60 Width mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net Weight kg 86 95 95 98 Pipe Connection -Liquid mm 9.52 9.52 9.52 9.52 Height mm 852 852 852 852 Width mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net Weight kg 86 95 95 98 Pipe Connection -Liquid mm 9.52 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 15.88 Pipe Connection -Gas mm 15.88 15.88 15.88 15.88 4) I) FOR ACK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. 4) I) FOR ACK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.