Ceiling Mounted Cassette Unit

Similar documents
Ceiling Mounted Cassette Unit

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PLXSID1605. Warning HEAD OFFICE :

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

All Product Catalogue

Inverter Y Series.

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Inverter Wall Mounted Series

RC-0219-A. Single-Split Non Inverter Series

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

Innovative air conditioning

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

U-Match Systems 12,000 to 60,000 BTU/Hr 60 Hz

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Light commercial range. Passion at work

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Residential and Light Commercial Ductless Systems Catalog

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

R410A Multi Digital Scroll System

Inverter Wall Mounted

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

Product Section New Product Introduction

About Daikin: WARNINGS:

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Wall Mounted Split Systems

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Inventor of the Inverter Digital Inverter System

Non Inverter Wall Mounted Series

Ultimate VRF System R410A, 50Hz

Q Series. Inverter Split Systems

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

Hi - Wall Split Systems 12K - 18K - 24K

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

InverterFlex SERIES InverterFlex Systems condition up to five rooms

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

2 &3-4 Head Multi System

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Model: Ceiling Cassette V 9k-24k

THE WORLD S MOST EFFICIENT HEAT PUMP

DUCTLESS FULL LINE CATALOG

DESIGNER RANGE SLEEK, MODERN FINISH HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

INVERTER Y SINGLE SPLIT SERIES II

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

HEAT PUMPS. Efficient Comfort For Every Season

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Air Conditioning & Heating. Ductless Product Catalog

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

ART الرفاهية تكنولوچيا بلمسة فنية

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

AIR CONDITIONING REVERSE-CYCLE INVERTER

LV Series. SEER 15+ Concealed Built in Heat Pump

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

Ductless Series Variable Speed Split Systems

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Business. The business range. The most advanced solutions for larger buildings.

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Energy-saving operation

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Heating & Cooling Products

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

... Air Conditioners & Heat Pumps Light Commercial ...

JUNE & 3-4 Head Multi System

Inverter Wall Mounted

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Specifications, Performance & Submittal

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

G Series Inverter Split Systems

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

Heat Pump Air Conditioning Systems

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

Presents. Variable Speed Heat Pump Ductless Split Systems

Carrier. Ductless Systems. Taking Comfort, And Your Business, Further. The Right Solution. Right Now.

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

Up to SEER 26.1 Wall Mount Heat Pump

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Transcription:

Brochure AP-MCK-13 Ceiling Mounted Cassette Unit Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquayup.com. 2013 McQuay International www.mcquayup.com A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

Ceiling Cassette C series 4 Way Air Discharge And Air Swing It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room. Auto Mode Auto Mode allows the setting to change automatically between cool and heat mode depending on the room temperature and the set temperature required. Stylish And Slim Panel The slim panel can be blended easily into interior decoration and design. Hot Keep Cycle During heat mode hot keep cycle, the fan will run at low speed during the thermostat cycle off. As a result, one will not feel the draft of cold air discharge from the unit. Option of fan stop or fan run at specific interval timing can also be selected. Self Diagnosis This intelligent feature helps to detect any faults or malfunctioning in the system and give user a warning by blinking of the LED lights. Choices Of Netware III Wired And Wireless Controller GS01 SLM 8 Wired Controller (Field Installed Optional Accessories) NIM-Able The MCK-C series is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a systems of multiple indoor units in a building. * Refer local representative for details. M(5)CK 010/015/020 C/CR Cooling: 9500 Btu/h - 19000 Btu/h 2.78 kw - 5.57 kw Heating: 9500 Btu/h - 19500 Btu/h 2.78 kw - 5.72 kw M(5)LC 010/015 C/CR M(5)LC 018/020 C/CR Built-In High Head Drain Pump The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level. 700mm Compact Design The Ceiling Cassette C series is designed to be compact. Its body dimension is only 570mm X 570mm which can easily fit into a 600mm ceiling grids. This make installation a lot easier. Ceiling panel T bar 600 mm

Ceiling Cassette E series Modern And Elegant Panel It is designed with unique round side contour and new LED light location. Rotateable intake grill promote uniform installation. Allow 90 Rotation Superior Sound Level The MCK-E series is equipped with a newly-developed turbo fan; the shape produce low air turbulence. Model M(5)CK 020E/ER M(5)CK 025E/ER M(5)CK 028E/ER M(5)CK 040E/ER M(5)CK 050E/ER Max (dba) 34 37 42 47 49 Min (dba) 28 32 33 36 39 With up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 28dBA. Multi-Comfort - 3 Air Swing Pattern Control To increase the comfort level of the air conditioned area of MCK-E series, the system had been built in with 3 different type of air flow pattern to suit different requirement. M(5)CK 020/025/028/ 040/050 E/ER Cooling: 18300 Btu/h 49500 Btu/h 5.3 kw 14.5 kw PATTERN 1 Standard Setting For gentle drafts. 50 Draft Prevention Setting Select this setting to eliminate direct drafts which can lead to discomfort. PATTERN 2 The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control. 50 55 Setting to Prevent Soiling of Ceiling Recommended for location with light colour ceiling that must be kept potless. PATTERN 3 55 Heating: 17700 Btu/h 50000 Btu/h 5.1 kw 14.7 kw Lower Height Model The MCK-E series height is as low as 300mm to ease installation. Dimension (mm) Model A B M(5)CK 020 ~ 028E/ER 265 300 M(5)CK 040 ~ 050E/ER 300 335 A B Optimum Air Discharge Combining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional of the automatic air swing help further to evenly distribute conditioned air to every corner of the instrall area. Built-In High Head Drain Pump The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level. 700mm

Specifications CEILING CASSETTE MCK-C SERIES - R22 COOLING ONLY CEILING CASSETTE M5CK-C SERIES - R410A COOLING ONLY MCK 010C MCK 015C MCK 020C MCK 020C M5CK 010C M5CK 015C M5CK 020C M5CK 020C MLC 010C MLC 015C MLC 018C MLC 020C M5LC 010C M5LC 015C M5LC 020C M5LC 020C Btu/h 9500 12500 18000 19000 W 2780 3663 5280 5570 Btu/hr 9500 12500 17500 18000 W 2780 3660 5129 5280 W/W 3.03 3.04 2.87 3.04 W/W 3.09 2.82 3.03 3.06 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 46 49 52 51 Sound Pressure Level dba 46 49 52 52 Net Weight kg 28 28 43 47 Net Weight kg 28 30 47 47 Pipe Connection -Gas mm 9.52 12.70 15.88 15.88 Pipe Connection -Gas mm 9.52 12.70 12.70 12.70 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. CEILING CASSETTE MCK-CR SERIES - R22 HEATPUMP MCK 010CR MCK 015CR MCK 020CR MCK 020CR MLC 010CR MLC 015CR MLC 018CR MLC 020CR Btu/h 9500 12500 18000 19000 W 2780 3660 5280 5570 Btu/h 9500 12500 18400 19500 W 2780 3660 5390 5720 W/W 3.03 3.04 2.87 3.04 W/W 3.40 3.47 3.21 3.21 Sound Pressure Level dba 46 49 51 51 Net Weight kg 30 30 43 47 Pipe Connection -Gas mm 9.52 12.70 15.88 15.88 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. CEILING CASSETTE M5CK-CR SERIES - R410A HEATPUMP M5CK 010CR M5CK 015CR M5CK 020CR M5CK 020CR M5LC 010CR M5LC 015CR M5LC 020CR M5LC 020CR Btu/hr 9500 12500 17500 18000 W 2780 3660 5129 5280 Btu/hr 9500 11500 17500 18500 W 2780 3370 5129 5420 W/W 3.09 2.82 3.03 3.06 W/W 3.35 3.30 3.00 3.63 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 46 49 52 52 Net Weight kg 28 30 47 47 Pipe Connection -Gas mm 9.52 12.70 12.70 12.70 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD.

Specifications CEILING CASSETTE MCK-E SERIES - R22 COOLING ONLY MCK 020E MCK 025E MCK 028E MCK 040E MLC 020C MLC 025C MLC 028C MLC 35D Btu/h 19500 25000 27000 35000 W 5715 7327 7913 10258 W/W 2.92 2.88 2.91 3.41 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Sound Pressure Level dba 51 52 58 58 CEILING CASSETTE MCK-ER SERIES - R22 HEATPUMP MCK 020ER MCK 025ER MCK 028ER MCK 040ER MLC 020CR MLC 025CR MLC 028CR MLC 35DR Btu/h 19500 25000 27000 35000 W 5715 7327 7913 10258 Btu/h 19500 25000 28000 35000 W 5715 7327 8206 10258 W/W 2.92 2.88 2.91 3.41 W/W 3.38 3.17 3.49 3.73 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Net Weight kg 47 57 57 95 Pipe Connection -Liquid mm 6.35 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 19.05 Sound Pressure Level dba 51 52 58 58 Net Weight kg 47 57 57 95 Pipe Connection -Liquid mm 6.35 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 19.05 MCK 040E MCK 040E MCK 050E MLC 40D MLC 40D MLC 50D Btu/h 39000 39500 49500 W 11430 11600 14500 W/W 3.31 3.17 3.15 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] Width [with Panel] mm 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 MCK 040ER MCK 040ER MCK 050ER MLC 40DR MLC 40DR MLC 50DR Btu/h 39500 39500 48000 W 11600 11600 14100 Btu/h 42000 42000 50000 W 12300 12300 14700 W/W 3.22 3.31 2.93 W/W 3.79 3.85 3.49 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] Width [with Panel] mm 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 Height mm 852 852 852 Width mm 1030 1030 1030 Depth mm 400 400 400 Net Weight kg 100 100 105 Pipe Connection -Liquid mm 9.52 9.52 9.52 Pipe Connection -Gas mm 19.05 19.05 19.05 Sound Pressure Level dba 58 58 58 Height mm 852 852 852 Width mm 1030 1030 1030 Depth mm 400 400 400 Net Weight kg 100 100 105 Pipe Connection -Liquid mm 9.52 9.52 9.52 Pipe Connection -Gas mm 19.05 19.05 19.05 4) I) FOR MCK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. 4) I) FOR MCK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.

Specifications CEILING CASSETTE M5CK-E SERIES - R410A COOLING ONLY M5CK 020E M5CK 025E M5CK 028E M5CK 040E M5LC 020C M5LC 025C M5LC 028C M5LC 35D Btu/hr 18300 22200 27000 29200 W 5363 6506 7913 8558 W/W 3.08 3.36 2.84 3.03 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Sound Pressure Level dba 52 52 58 58 Net Weight kg 47 50 57 86 Pipe Connection -Liquid mm 6.35 6.35 9.52 9.52 Pipe Connection -Gas mm 12.70 15.88 15.88 15.88 CEILING CASSETTE M5CK-ER SERIES - R410A HEATPUMP M5CK 020ER M5CK 025ER M5CK 028ER M5CK 040ER M5LC 020CR M5LC 025CR M5LC 028CR M5LC 35DR Btu/hr 18300 22200 27000 29200 W 5363 6506 7913 8558 Btu/hr 17700 20500 28000 31800 W 5188 6008 8206 9320 W/W 3.08 3.36 2.84 3.03 W/W 3.48 3.41 3.53 3.66 Net Weight [with Panel] kg 26 [30] 28 [32] 31[35] 39 [43] Sound Pressure Level dba 52 52 58 58 Net Weight kg 47 50 57 86 Pipe Connection -Liquid mm 6.35 6.35 9.52 9.52 Pipe Connection -Gas mm 12.70 15.88 15.88 15.88 M5CK 040E M5CK 040E M5CK 040E M5CK 050E M5LC 35D M5LC 40D M5LC 40D M5LC 50D Btu/hr 31000 39000 39000 45000 W 9086 11430 11430 13190 W/W 3.28 2.92 2.98 2.93 Air Flow CFM 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] 300 [375] Net Weight [with Panel] kg 39 [43] 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 60 M5CK 040ER M5CK 040ER M5CK 040ER M5CK 050ER M5LC 35DR M5LC 40DR M5LC 40DR M5LC 50DR Btu/hr 31000 39000 39000 45000 W 9086 11430 11430 13190 Btu/hr 33400 39000 39500 48000 W 9789 11430 11577 14070 W/W 3.28 2.92 2.98 2.93 W/W 3.84 3.06 3.21 3.43 Air Flow CFM 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] 300 [375] Net Weight [with Panel] kg 39 [43] 39 [43] 39 [43] 41[45] Power Supply V/Ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Height mm 852 852 852 852 Sound Pressure Level dba 58 58 58 60 Width mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net Weight kg 86 95 95 98 Pipe Connection -Liquid mm 9.52 9.52 9.52 9.52 Height mm 852 852 852 852 Width mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net Weight kg 86 95 95 98 Pipe Connection -Liquid mm 9.52 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 15.88 Pipe Connection -Gas mm 15.88 15.88 15.88 15.88 4) I) FOR ACK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. 4) I) FOR ACK 20/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.